The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Limitations of Clinical and Sonographic Estimates of Birth Weight: Experience With 1034 Parturients
Abstract
OBJECTIVE: To compare the accuracy of clinical and sonographic estimates of fetal weight made throughout the third trimester of pregnancy. METHODS: Patients in early labor had fetal weight estimated by two approaches: 1) clinical evaluation and palpation followed by 2) sonographic mensuration of fetal biparietal diameter, abdominal circumference, and femur length applied to Hadlock's formula. The accuracy of these two methods of estimating fetal weight was compared using Student t test, Wilcoxon test, and chi2 tests. P < .05 was considered significant. Prediction limits (50th, 90th, and 95th percentiles) were calculated for both techniques by obtaining the range of actual weights associated for a particular estimated fetal weight (EFW). RESULTS: We enrolled 1034 parturients whose clinical EFWs yielded significantly higher mean (+/- standard deviation) simple error (48.2 +/- 411 g) and standardized absolute error (130 +/- 122 g/kg) than were obtained by use of sonographic formulas for EFW (-6.6 +/- 381 g and 104 +/- 89 g/kg, respectively). When the population was partitioned by gestational age, we found that sonographic EFW was more accurate than clinical EFW in preterm (n = 373) but not in term (n = 460) or post-term (n = 201) pregnancies. Prediction limits indicate that for a given EFW, for example, 800 g, the 90% ranges of actual weight based on clinical and sonographic EFW are 566-1829 g and 469-1667 g, respectively. CONCLUSION: The apparent superiority of sonographic EFW over clinical EFW applies principally to preterm pregnancies. The prediction limitation calculation suggests that either method, for any particular estimate between 500 and 4500 g, has limited value in the estimation of actual birth weight, because this outcome is highly variable and frequently lies outside of the useful bandwidth (+/- 10%) for prospective management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682
Cited by
New Intrauterine Growth Curves Based on United States Data
Olsen, I. E., Groveman, S. A., Lawson, M. L., Clark, R. H., & Zemel, B. S. (2010) · Pediatrics · doi:10.1542/peds.2009-0913 · Cited by 867
ACOG Practice Bulletin No. 201: Pregestational Diabetes Mellitus
(2018) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002960 · Cited by 470
Macrosomia: ACOG Practice Bulletin, Number 216
(2020) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000003606 · Cited by 331
Shoulder dystocia: The unpreventable obstetric emergency with empiric management guidelines
Gherman, R. B., Chauhan, S., Ouzounian, J. G., Lerner, H., Gonik, B., & Goodwin, T. M. (2006) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2005.09.007 · Cited by 280
Self-citationSuspicion and treatment of the macrosomic fetus: A review
Chauhan, S. P., Grobman, W. A., Gherman, R. A., Chauhan, V. B., Chang, G., Magann, E. F., & Hendrix, N. W. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.12.020 · Cited by 270
Self-citation
Metadata
- Authors
- Chauhan, S.
- Venue
- Obstetrics & Gynecology
- Published
- 1998-01
- Volume
- 91
- Issue
- 1
- Pages
- 72-77
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2996777258
- Cited by
- 209
- References
- 1
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limitations of Clinical and Sonographic Estimates of Birth Weight: Experience With 1034 Parturients. https://app.cochat.ai/papers/10.1016/s0029-7844(97)00590-5
- The paper
- Chauhan, S. (1998). Limitations of Clinical and Sonographic Estimates of Birth Weight: Experience With 1034 Parturients. Obstetrics & Gynecology. https://doi.org/10.1016/s0029-7844(97)00590-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.