CoChat

A Comparison of Clinical and Ultrasonic Estimation of Fetal Weight

Sherman, D · 1998 · Obstetrics & Gynecology
Cited by 149

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To compare the accuracy of routine ultrasonic and clinical birth weight estimation. METHODS: The study sample included 1717 women with singleton pregnancies, admitted in early labor with an ultrasonic estimated fetal weight (EFW) performed during the preceding week. Clinical EFW was obtained before rupture of the membranes by the attending senior resident, who was unaware of the ultrasonic EFW. Accuracy was determined by the percentage error, the absolute percentage error, and the proportion of estimates within 10% of the actual birth weight (birth weight +/- 10%). Statistical analysis was done by the paired t test, the comparison of correlated variances, the Wilcoxon sign test, and the chi2 test. Actual birth weight in the study sample averaged 3334+/-607 g (+/- standard deviation, [SD]) and ranged between 690 and 5320 g. RESULTS: The means of all error terms of the clinical EFW were significantly smaller than those of the ultrasonic EFW. However, the rates of estimates within 10% of birth weight were not significantly different (72 and 69%, respectively). In birth weights less than 2500 g, both methods overestimated the birth weight, but the mean errors of the ultrasonic EFW were significantly smaller than those of the clinical EFW. The ultrasonic EFW had significantly higher rates of birth weight +/- 10% than the clinical EFW (63 compared to 49%, respectively). In the 2500-4000 g birth weight, only the clinical EFW had no systematic error, whereas the ultrasonic EFW underestimated the birth weight. The mean errors of the clinical EFW were significantly smaller and the rate of birth weight +/- 10% significantly higher than those of the ultrasonic EFW. In the birth weight greater than 4000 g, both methods underestimated the birth weight, and the mean errors and the rate of estimates within 10% of birth weight were similar for both methods. CONCLUSION: Clinical estimation of birth weight in early labor is as accurate as routine ultrasonic estimation obtained in the preceding week. In the lower range of birth weight (less than 2500 g), ultrasonic estimation is more accurate; in the 2500-4000 g range, clinical estimation is more accurate. In the higher range of birth weight (greater than 4000 g), both methods have similar accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0029-7844(97)00654-6

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 149

Metadata

Authors
Sherman, D.
Venue
Obstetrics & Gynecology
Published
1998-02
Volume
91
Issue
2
Pages
212-217
ISSN
0029-7844 (ISSN-L)
OpenAlex
W1973936103
Cited by
149
References
2
FWCI
10.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of Clinical and Ultrasonic Estimation of Fetal Weight. https://app.cochat.ai/papers/10.1016/s0029-7844(97)00654-6
The paper
Sherman, D. (1998). A Comparison of Clinical and Ultrasonic Estimation of Fetal Weight. Obstetrics & Gynecology. https://doi.org/10.1016/s0029-7844(97)00654-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.