CoChat

Prenatal plasma matrix metalloproteinase-9 levels to predict spontaneous preterm birth

Tu, F · 1998 · Obstetrics & Gynecology

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Matrix metalloproteinase-9, a zinc-dependent proteinase, may be important in initiating labor or rupture of membranes. We determined plasma levels of this enzyme in nonpregnant and pregnant women and evaluated whether they predict spontaneous preterm delivery. METHODS: A sandwich enzyme-linked immunosorbent assay (ELISA) was used to measure matrix metalloproteinase-9 levels in plasma samples from 25 nonpregnant women (mean age 39+/-9 years) and in stored plasma samples obtained during a randomized trial of zinc supplementation in pregnancy. Women were selected who delivered following spontaneous labor or premature rupture of membranes at 24-32 weeks (n = 20), 33-36 weeks (n = 29), and greater than 37 weeks (n = 30). Plasma samples were obtained sequentially at 19, 26, 31, and 36 weeks if undelivered and at presentation for delivery. RESULTS: Plasma matrix metalloproteinase-9 levels for non-pregnant women averaged 18.6+/-11.2 (mean +/- standard deviation) ng/mL. Prenatal values averaged 298+/-227 ng/mL from 19 weeks until 36 weeks (not including presentation for delivery) and did not change significantly as the gestational age increased, regardless of whether women ultimately delivered at 24-32, 33-36, or after 37 weeks. Values obtained prior to, but within 1 week of, presentation for delivery (n = 7, 281+/-103 ng/mL) were not significantly different than those obtained earlier in pregnancy (n = 71, 309+/-307 ng/mL, [P = .60]). Plasma matrix metalloproteinase-9 levels for women in spontaneous labor were similar regardless of gestational age and were increased three-fold (852+/-301 ng/mL) compared with those drawn at each prenatal visit (for example, 26 week values = 285+/-144 ng/mL [P < .001]). CONCLUSION: Plasma matrix metalloproteinase-9 levels remain unchanged throughout pregnancy until the onset of spontaneous labor when there is a three-fold increase. Plasma matrix metalloproteinase-9 levels obtained prior to presentation for delivery do not appear to predict spontaneous preterm birth.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0029-7844(98)00222-1

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 16 references

Cited by

See all 42

Metadata

Authors
Tu, F.
Affiliations
University of Alabama at Birmingham (US)
Venue
Obstetrics & Gynecology
Published
1998-09
Volume
92
Issue
3
Pages
446-449
ISSN
0029-7844 (ISSN-L)
OpenAlex
W1989383266
Cited by
42
References
16
Citations by year
2023: 1 · 2019: 2 · 2018: 1 · 2016: 2 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 1
FWCI
2.74
Type
journal article
Language
en
Open access
closed
Locations
  • Obstetrics and Gynecology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Obstetrics and Gynecology › Preterm Birth and Chorioamnionitis
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cancer Research › Protease and Inhibitor Mechanisms
  • Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
Keywords
MMP-9, preterm birth, spontaneous labor, plasma biomarkers, pregnancy, zinc supplementation, premature rupture of membranes, labor onset prediction
MeSH terms
Adult, Female, Humans, Obstetric Labor, Premature, Predictive Value of Tests, Pregnancy, Collagenases, Matrix Metalloproteinase 9

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prenatal plasma matrix metalloproteinase-9 levels to predict spontaneous preterm birth. https://app.cochat.ai/papers/10.1016/s0029-7844(98)00222-1
The paper
Tu, F. (1998). Prenatal plasma matrix metalloproteinase-9 levels to predict spontaneous preterm birth. Obstetrics & Gynecology. https://doi.org/10.1016/s0029-7844(98)00222-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.