CoChat

Second-trimester cervical ultrasound: associations with increased risk for recurrent early, spontaneous delivery

Andrews, W · 2000 · Obstetrics & Gynecology

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To determine whether short cervical length or internal os funneling before 20 weeks' gestation predicts early preterm birth or pregnancy loss in women with at least one prior spontaneous early preterm birth. METHODS: Transvaginal cervical ultrasound examinations were done every 2 weeks on 69 women with singleton gestations and histories of at least one prior spontaneous birth between 16 and 30 weeks' gestation. The results of those examinations were correlated with gestational age at delivery. RESULTS: Among 53 women who had ultrasound examinations before 20 weeks' gestation, those with cervical lengths at or below the tenth percentile for the study population (22 mm, n = 4) or funneling of the internal os (n = 5) were more likely than women without those factors to have spontaneous preterm births within 2 weeks (33% versus 0%, P = .01) or 4 weeks from the ultrasound examination (67% versus 0%, P < .001) or before 35 weeks' gestation (100% versus 19%, P < .001). Short cervical length or funneling between 20-24 and 25-29 weeks was also associated with increased risk of spontaneous preterm birth before 35 weeks' gestation (P < or = .05 and P = .002, respectively) but not with increased risk of spontaneous preterm birth within 2 or 4 weeks of ultrasound examination. CONCLUSION: Women with prior early spontaneous preterm births who have short cervical lengths or funneling of the internal cervical os before 20 weeks' gestation are at increased risk of subsequent spontaneous preterm birth.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0029-7844(99)00483-4

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 7 references

Cited by

See all 137

Metadata

Authors
Andrews, W.
Affiliations
University of Alabama at Birmingham (US)
Corresponding author
Andrews, W
Venue
Obstetrics & Gynecology
Published
2000-02
Volume
95
Issue
2
Pages
222-226
ISSN
0029-7844 (ISSN-L)
OpenAlex
W2078807458
Cited by
135
References
7
Citations by year
2025: 1 · 2024: 2 · 2023: 1 · 2022: 4 · 2021: 1 · 2020: 8 · 2019: 2 · 2018: 6 · 2017: 7 · 2016: 4 · 2015: 6 · 2014: 4 · 2013: 5 · 2012: 1
FWCI
5.08
Type
journal article
Language
en
Open access
closed
Locations
  • Obstetrics and Gynecology (publishedVersion)
  • PubMed (publishedVersion)
Funders
U.S. Public Health Service (290-92-0055)
Topics
  • Health Sciences › Medicine › Obstetrics and Gynecology › Preterm Birth and Chorioamnionitis
  • Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Reproductive Health and Contraception
Keywords
cervical length, recurrent preterm birth, miscarriage, transvaginal ultrasound, singleton pregnancy
MeSH terms
Cervix Uteri, Female, Humans, Obstetric Labor, Premature, Predictive Value of Tests, Pregnancy, Pregnancy Trimester, Second, Sensitivity and Specificity, Ultrasonography, Prenatal, Pregnancy, High-Risk

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Second-trimester cervical ultrasound: associations with increased risk for recurrent early, spontaneous delivery. https://app.cochat.ai/papers/10.1016/s0029-7844(99)00483-4
The paper
Andrews, W. (2000). Second-trimester cervical ultrasound: associations with increased risk for recurrent early, spontaneous delivery. Obstetrics & Gynecology. https://doi.org/10.1016/s0029-7844(99)00483-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.