Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 509

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Mid-Trimester Endovaginal Sonography in Women at High Risk for Spontaneous Preterm Birth

Owen, John·2001·JAMA

Abstract

CONTEXT: Although shortened cervical length has been consistently associated with spontaneous preterm birth, it is not known when in gestation this risk factor becomes apparent. OBJECTIVE: To determine whether sonographic cervical findings between 16 weeks' and 18 weeks 6 days' gestation predict spontaneous preterm birth and whether serial evaluations up to 23 weeks 6 days' gestation improve prediction in high-risk women. DESIGN, SETTING, AND PARTICIPANTS: Blinded observational study performed between March 1997 and November 1999 at 9 university-affiliated medical centers in the United States in 183 women with singleton gestations who previously had experienced a spontaneous birth before 32 weeks' gestation. OBSERVATION: Certified sonologists performed 590 endovaginal sonographic examinations at 2-week intervals. Cervical length was measured from the external os to the functional internal os along a closed endocervical canal. Funneling and dynamic cervical shortening were also recorded. MAIN OUTCOME MEASURE: Spontaneous preterm birth before 35 weeks' gestation, analyzed by selected cutoff values of cervical length. RESULTS: Forty-eight women (26%) experienced spontaneous preterm birth before 35 weeks' gestation. A cervical length of less than 25 mm at the initial sonographic examination was associated with a relative risk (RR) for spontaneous preterm birth of 3.3 (95% confidence interval [CI], 2.1-5.0; sensitivity = 19%; specificity = 98%; positive predictive value = 75%). After controlling for cervical length, neither funneling (P =.24) nor dynamic shortening (P =.054) were significant independent predictors of spontaneous preterm birth. However, using the shortest ever observed cervical length on serial evaluations, after any dynamic shortening, the RR of a cervical length of less than 25 mm for spontaneous preterm birth increased to 4.5 (95% CI, 2.7-7.6; sensitivity = 69%; specificity = 80%; positive predictive value = 55%). Compared with a single cervical measurement at 16 weeks' to 18 weeks 6 days' gestation, serial measurements at up to 23 weeks 6 days significantly improved the prediction of spontaneous preterm birth in a receiver operating characteristic curve analysis (P =.03). CONCLUSIONS: Cervical length assessed by endovaginal sonography between 16 weeks' and 18 weeks 6 days' gestation, augmented by serial evaluations, predicts spontaneous preterm birth before 35 weeks' gestation in high-risk women.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.286.11.1340

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 509

Metadata

Authors
Owen, J.
Venue
JAMA
Published
2001-09-19
Volume
286
Issue
11
Pages
1340
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2074766136
Cited by
509
References
3
FWCI
7.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mid-Trimester Endovaginal Sonography in Women at High Risk for Spontaneous Preterm Birth. https://app.cochat.ai/papers/10.1001/jama.286.11.1340
The paper
Owen, J. (2001). Mid-Trimester Endovaginal Sonography in Women at High Risk for Spontaneous Preterm Birth. JAMA. https://doi.org/10.1001/jama.286.11.1340

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.