Effect of study design on the association between nuchal translucency measurement and Down syndrome
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the effect of verification bias on the accuracy of first-trimester nuchal translucency measurement for Down syndrome detection. METHODS: We used MEDLINE and EMBASE to identify all papers relating the results of nuchal translucency measurement to fetal karyotype. The detected studies were scored for verification bias. Fifteen studies without and ten with verification bias were included. RESULTS: Sensitivity and specificity were calculated for each study. For studies with verification bias, adjusted estimates of the sensitivity were calculated assuming a fetal loss rate for Down syndrome pregnancies of 48%. The sample size weighted sensitivity was 55% in studies without and 77% in those with verification bias, for specificities of 96% and 97%, respectively. After adjustment for verification bias, the sample size weighted sensitivity changed from 77% to 63%. CONCLUSION: Studies with verification bias reported higher sensitivities, but also slightly higher specificities of nuchal translucency measurement than studies without verification bias. The difference in sensitivity is greater than could be explained by verification bias. We postulate that the experience of the sonographist might be an explanation for the differences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572 · cited 1×
“Such data were recently provided by Snijders et al in a study that reported on over 100,000 women, thereby being the largest cohort thus far.(35) This study, not included in the present analysis since it was published after February 1998, is an extension of the study published by Pandya et al.”
Result
Cited by
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · BMC Medical Research Methodology · doi:10.1186/1471-2288-1-2 · Cited by 2,755
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
“Studies in which the decision to perform fetal karyotyping depended on the result of nuchal translucency measurement considerably overestimated the sensitivity of nuchal translucency (34).”
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Evidence of bias and variation in diagnostic accuracy studies
Rutjes, A. W. S., Reitsma, J. B., Di Nisio, M., Smidt, N., van Rijn, J. C., & Bossuyt, P. M. M. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.050090 · Cited by 611
Variation of a test’s sensitivity and specificity with disease prevalence
Leeflang, M. M. G., Rutjes, A. W. S., Reitsma, J. B., Hooft, L., & Bossuyt, P. M. M. (2013) · Canadian Medical Association Journal · doi:10.1503/cmaj.121286 · Cited by 530
Self-citation
Metadata
- Authors
- MOL, B.
- Venue
- Obstetrics & Gynecology
- Published
- 1999-11
- Volume
- 94
- Issue
- 5
- Pages
- 864-869
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2105574076
- Cited by
- 51
- References
- 1
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.