Indoor and outdoor air quality investigation at schools in Hong Kong
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Five classrooms in Hong Kong (HK), air-conditioned or ceiling fans ventilated, were chosen for investigation of indoor and outdoor air quality. Parameters such as temperature, relative humidity (RH), carbon dioxide (CO2), sulphur dioxide (SO2), nitric oxide (NO), nitrogen dioxide (NO2), respirable particulate matter (PM10), formaldehyde (HCHO), and total bacteria counts were monitored indoors and outdoors simultaneously. The average respirable particulate matter concentrations were higher than the HK Objective, and the maximum indoor PM10 level exceeded 1000 microg/m3. Indoor CO2 concentrations often exceeded 1000 microl/l in air-conditioning and ceiling fan classrooms, indicating inadequate ventilation. Maximum indoor CO2 level reached 5900 microl/l during class at the classroom with cooling tower ventilation. Increasing the rate of ventilation or implementation of breaks between classes is recommended to alleviate the high CO2 level. Other pollution parameters measured in this study complied with the standards. The two most important classroom air quality problems in Hong Kong were PM10 and CO2 levels.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We considered this method because recently ATP levels as the measures of the total microbial activity or microbial load were explored by several researchers in different kinds of clinical or hospital environmental settings [30,31,32], as well as in field experiments on bioaerosol monitoring and evaluation of bioaerosol samplers [33].”
Citations
Cites
Air pollution. Its origin and control
(1977) · Environmental Pollution (1970) · doi:10.1016/0013-9327(77)90079-9 · Cited by 513
Norback, D., Torgen, M., & Edling, C. (1990) · Occupational and Environmental Medicine · doi:10.1136/oem.47.11.733 · Cited by 202
Indoor/Outdoor Air Quality: Reference Pollutant Concentrations in Complaint-Free Residences
Montgomery, D. D., & Kalman, D. A. (1989) · Applied Industrial Hygiene · doi:10.1080/08828032.1989.10389885 · Cited by 44
Research works printed but not linked: 2
- Gusten, 1995, Experiences of measures taken to improve the air quality in schools, Air Infiltration Review, 16, 5
- Koo, L.C.L., Luk, M.Y., Mok, M.Y., Yuen, J.H.F., Yuen, T.Y.S., 1997. Health effects from air conditioning: epidemiologic studies on schools and offices in Hong Kong. In: Proceedings of Indoor and Built Environment Problems in Asia, Kuala Lumpur, Malaysia, pp. 76–86
Cited by
Characteristics of carbonaceous aerosol in Pearl River Delta Region, China during 2001 winter period
Cao, J. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)01002-6 · Cited by 606
Indoor aerosols: from personal exposure to risk assessment
Morawska, L., Afshari, A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Hänninen, O., Hofmann, W., Isaxon, C., Jayaratne, E. R., Pasanen, P., et al. (2013) · Indoor Air · doi:10.1111/ina.12044 · Cited by 442
Fromme, H., Twardella, D., Dietrich, S., Heitmann, D., Schierl, R., Liebl, B., & Rüden, H. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.08.053 · Cited by 359
Relationship between outdoor and indoor air quality in eight French schools
Blondeau, P., Iordache, V., Poupard, O., Genin, D., & Allard, F. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00263.x · Cited by 317
Indoor air quality in Michigan schools
Godwin, C., & Batterman, S. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00459.x · Cited by 263
Metadata
- Authors
- Lee, S. C., & Chang, M.
- Affiliations
- Hong Kong Polytechnic University (HK)
- Corresponding author
- Lee, S.C
- ORCID
- Lee, S.C
- Venue
- Chemosphere
- Publisher
- Elsevier BV
- Published
- 2000-07
- Volume
- 41
- Issue
- 1-2
- Pages
- 109-113
- ISSN
- 0045-6535 (ISSN-L)
- OpenAlex
- W2043891653
- Cited by
- 356
- References
- 3
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 19 · 2023: 18 · 2022: 17 · 2021: 24 · 2020: 21 · 2019: 18 · 2018: 28 · 2017: 11 · 2016: 11 · 2015: 18 · 2014: 25 · 2013: 17 · 2012: 17
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Chemosphere (publishedVersion)
- PubMed (publishedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor air quality, outdoor air quality, school classrooms, carbon dioxide, ventilation, air conditioning, ceiling fans, respirable particles, PM10, formaldehyde, sulfur dioxide, nitrogen dioxide, nitric oxide, Hong Kong
- MeSH terms
- Air Pollution, Bacteria, Carbon Dioxide, Environmental Monitoring, Formaldehyde, Humans, Humidity, Nitric Oxide, Nitrogen Dioxide, Particle Size, Public Health, Schools, Sulfur Dioxide, Temperature, Ventilation, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Indoor and outdoor air quality investigation at schools in Hong Kong. https://app.cochat.ai/papers/10.1016/s0045-6535(99)00396-3
- The paper
- Lee, S. C., & Chang, M. (2000). Indoor and outdoor air quality investigation at schools in Hong Kong. Chemosphere. https://doi.org/10.1016/s0045-6535(99)00396-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.