CoChat

Indoor and outdoor air quality investigation at schools in Hong Kong

Lee, S.C, Chang, M · 2000 · Chemosphere

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Five classrooms in Hong Kong (HK), air-conditioned or ceiling fans ventilated, were chosen for investigation of indoor and outdoor air quality. Parameters such as temperature, relative humidity (RH), carbon dioxide (CO2), sulphur dioxide (SO2), nitric oxide (NO), nitrogen dioxide (NO2), respirable particulate matter (PM10), formaldehyde (HCHO), and total bacteria counts were monitored indoors and outdoors simultaneously. The average respirable particulate matter concentrations were higher than the HK Objective, and the maximum indoor PM10 level exceeded 1000 microg/m3. Indoor CO2 concentrations often exceeded 1000 microl/l in air-conditioning and ceiling fan classrooms, indicating inadequate ventilation. Maximum indoor CO2 level reached 5900 microl/l during class at the classroom with cooling tower ventilation. Increasing the rate of ventilation or implementation of breaks between classes is recommended to alleviate the high CO2 level. Other pollution parameters measured in this study complied with the standards. The two most important classroom air quality problems in Hong Kong were PM10 and CO2 levels.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0045-6535(99)00396-3

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 3 references

Research works printed but not linked: 2

  1. Gusten, 1995, Experiences of measures taken to improve the air quality in schools, Air Infiltration Review, 16, 5
  2. Koo, L.C.L., Luk, M.Y., Mok, M.Y., Yuen, J.H.F., Yuen, T.Y.S., 1997. Health effects from air conditioning: epidemiologic studies on schools and offices in Hong Kong. In: Proceedings of Indoor and Built Environment Problems in Asia, Kuala Lumpur, Malaysia, pp. 76–86

Cited by

See all 406

Metadata

Authors
Lee, S. C., & Chang, M.
Affiliations
Hong Kong Polytechnic University (HK)
Corresponding author
Lee, S.C
Venue
Chemosphere
Publisher
Elsevier BV
Published
2000-07
Volume
41
Issue
1-2
Pages
109-113
ISSN
0045-6535 (ISSN-L)
OpenAlex
W2043891653
Cited by
356
References
3
Citations by year
2026: 4 · 2025: 7 · 2024: 19 · 2023: 18 · 2022: 17 · 2021: 24 · 2020: 21 · 2019: 18 · 2018: 28 · 2017: 11 · 2016: 11 · 2015: 18 · 2014: 25 · 2013: 17 · 2012: 17
FWCI
2.44
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Chemosphere (publishedVersion)
  • PubMed (publishedVersion)
  • PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
Keywords
indoor air quality, outdoor air quality, school classrooms, carbon dioxide, ventilation, air conditioning, ceiling fans, respirable particles, PM10, formaldehyde, sulfur dioxide, nitrogen dioxide, nitric oxide, Hong Kong
MeSH terms
Air Pollution, Bacteria, Carbon Dioxide, Environmental Monitoring, Formaldehyde, Humans, Humidity, Nitric Oxide, Nitrogen Dioxide, Particle Size, Public Health, Schools, Sulfur Dioxide, Temperature, Ventilation, Air Pollution, Indoor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Indoor and outdoor air quality investigation at schools in Hong Kong. https://app.cochat.ai/papers/10.1016/s0045-6535(99)00396-3
The paper
Lee, S. C., & Chang, M. (2000). Indoor and outdoor air quality investigation at schools in Hong Kong. Chemosphere. https://doi.org/10.1016/s0045-6535(99)00396-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.