The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Relationship between outdoor and indoor air quality in eight French schools
Open accessAbstract
UNLABELLED: In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO(2)), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO(2) concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO(2) indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size. PRACTICAL IMPLICATIONS: Assessing children's total exposure requires the knowledge of outdoor and indoor air contaminant concentrations. The study presented here provides data on compared outdoor and indoor concentration levels in school buildings, as well as information on the parameters influencing the relationship between outdoor and indoor air quality. It may be used as a basis for estimating indoor concentrations from outdoor concentrations data, or as a first step in designing buildings sheltering children against atmospheric pollution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
KLEPEIS, N. E., NELSON, W. C., OTT, W. R., ROBINSON, J. P., TSANG, A. M., SWITZER, P., BEHAR, J. V., HERN, S. C., & ENGELMANN, W. H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500165 · Cited by 4,803
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Ozone in Indoor Environments: Concentration and Chemistry
WESCHLER, C. J. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004269.x · Cited by 758
Activity patterns of Californians: Use of and proximity to indoor pollutant sources
Jenkins, P. L., Phillips, T. J., Mulberg, E. J., & Hui, S. P. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90402-7 · Cited by 415
Indoor and outdoor air quality investigation at schools in Hong Kong
Lee, S. C., & Chang, M. (2000) · Chemosphere · doi:10.1016/s0045-6535(99)00396-3 · Cited by 356
Baek, S.-O., Kim, Y.-S., & Perry, R. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(96)00215-4 · Cited by 298
Modeling pollutant penetration across building envelopes
Liu, D.-L., & Nazaroff, W. W. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00218-7 · Cited by 272
Particle deposition indoors: a review
Lai, A. C. K. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01159.x · Cited by 226
Removal of reactive gases at indoor surfaces: Combining mass transport and surface kinetics
Cano-Ruiz, J. A., Kong, D., Balas, R. B., & Nazaroff, W. W. (1993) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(93)90276-5 · Cited by 180
K. Koponen, I., Asmi, A., Keronen, P., Puhto, K., & Kulmala, M. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00338-1 · Cited by 162
Cited by
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Fromme, H., Twardella, D., Dietrich, S., Heitmann, D., Schierl, R., Liebl, B., & Rüden, H. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.08.053 · Cited by 359
Characterization of indoor air quality in primary schools in Antwerp, Belgium
Stranger, M., Potgieter-Vermaak, S. S., & Van Grieken, R. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00545.x · Cited by 198
Wichmann, J., Lind, T., Nilsson, M. A.-M., & Bellander, T. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.08.023 · Cited by 182
Pegas, P. N., Nunes, T., Alves, C. A., Silva, J. R., Vieira, S. L. A., Caseiro, A., & Pio, C. A. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.03.059 · Cited by 102
Metadata
- Authors
- Blondeau, P., Iordache, V., Poupard, O., Genin, D., & Allard, F.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2005-01
- Volume
- 15
- Issue
- 1
- Pages
- 2-12
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2049525034
- Cited by
- 317
- References
- 13
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship between outdoor and indoor air quality in eight French schools. https://app.cochat.ai/papers/10.1111/j.1600-0668.2004.00263.x
- The paper
- Blondeau, P., Iordache, V., Poupard, O., Genin, D., & Allard, F. (2005). Relationship between outdoor and indoor air quality in eight French schools. Indoor Air. https://doi.org/10.1111/j.1600-0668.2004.00263.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.