Indoor and outdoor air quality investigation at schools in Hong Kong
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Five classrooms in Hong Kong (HK), air-conditioned or ceiling fans ventilated, were chosen for investigation of indoor and outdoor air quality. Parameters such as temperature, relative humidity (RH), carbon dioxide (CO2), sulphur dioxide (SO2), nitric oxide (NO), nitrogen dioxide (NO2), respirable particulate matter (PM10), formaldehyde (HCHO), and total bacteria counts were monitored indoors and outdoors simultaneously. The average respirable particulate matter concentrations were higher than the HK Objective, and the maximum indoor PM10 level exceeded 1000 microg/m3. Indoor CO2 concentrations often exceeded 1000 microl/l in air-conditioning and ceiling fan classrooms, indicating inadequate ventilation. Maximum indoor CO2 level reached 5900 microl/l during class at the classroom with cooling tower ventilation. Increasing the rate of ventilation or implementation of breaks between classes is recommended to alleviate the high CO2 level. Other pollution parameters measured in this study complied with the standards. The two most important classroom air quality problems in Hong Kong were PM10 and CO2 levels.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We considered this method because recently ATP levels as the measures of the total microbial activity or microbial load were explored by several researchers in different kinds of clinical or hospital environmental settings [30,31,32], as well as in field experiments on bioaerosol monitoring and evaluation of bioaerosol samplers [33].”
Citations
Cites
Air pollution. Its origin and control
(1977) · Environmental Pollution (1970) · doi:10.1016/0013-9327(77)90079-9 · Cited by 513
Norback, D., Torgen, M., & Edling, C. (1990) · Occupational and Environmental Medicine · doi:10.1136/oem.47.11.733 · Cited by 202
Indoor/Outdoor Air Quality: Reference Pollutant Concentrations in Complaint-Free Residences
Montgomery, D. D., & Kalman, D. A. (1989) · Applied Industrial Hygiene · doi:10.1080/08828032.1989.10389885 · Cited by 44
Research works printed but not linked: 2
- Gusten, 1995, Experiences of measures taken to improve the air quality in schools, Air Infiltration Review, 16, 5
- Koo, L.C.L., Luk, M.Y., Mok, M.Y., Yuen, J.H.F., Yuen, T.Y.S., 1997. Health effects from air conditioning: epidemiologic studies on schools and offices in Hong Kong. In: Proceedings of Indoor and Built Environment Problems in Asia, Kuala Lumpur, Malaysia, pp. 76–86
Cited by
Items 301–400 of 406
Quantitative assessment of air quality in different indoor and outdoor environments in rural Bhutan
Wangchuk, T. (2016) · QUT ePrints (Queensland University of Technology) · Cited by 4
Concentrations of Indoor PM2.5 and PM10 Worldwide
Reátegui-Inga, M., Lu, J. K. G., Valdiviezo, W. A., Tocas, C. A. N., Tiza, P. R., Susanibar-Sandoval, D., Cisneros, A., Coaguila-Rodriguez, P., Cueva, A. F. C., Durand, R. P., et al. (2024) · International Journal of Sustainable Development and Planning · doi:10.18280/ijsdp.191238 · Cited by 3
Xie, Y. S., Song, B. X., Wang, T., & Wang, P. Y. (2010) · Advanced materials research · doi:10.4028/www.scientific.net/amr.113-116.1419 · Cited by 3
Hatta, M., & Han, H. (2019) · E3S Web of Conferences · doi:10.1051/e3sconf/201911106065 · Cited by 3
Adsorption of a Non-Woven Fabric with Activated Carbon for CO2
Liu, B. T., Shui, Y. H., & Zhu, G. Y. (2012) · Advanced materials research · doi:10.4028/www.scientific.net/amr.518-523.683 · Cited by 3
CFD simulation of local exhaust ventilation for aviation fire-test lab
Al-Ammari, A. S. H., Altarazi, Y. S. M., Talib, A. R. A., & Bheekhun, M. I. N. (2018) · International Journal of Engineering & Technology · doi:10.14419/ijet.v7i4.13.21353 · Cited by 3
Assessment of Indoor and Ambient Air Pollution at Complex Buildings in Hanoi
Lê, H. A., & Linh, L. T. (2019) · VNU Journal of Science Earth and Environmental Sciences · doi:10.25073/2588-1094/vnuees.4393 · Cited by 3
Radon Concentration in Various Indoor Environment and Effective Dose by Inhabitants in Korea
Lee, C.-M., Kim, Y., Roh, Y.-M., Kim, K.-Y., Jeon, J.-I., & Kim, J. (2007) · Korean Journal of Environmental Health Sciences · doi:10.5668/jehs.2007.33.4.264 · Cited by 3
Removal of Indoor Pollutants by Nano TiO2/beta-Cyclodextrin Coated Paper under UV Irradiation
Liu, Z., Yan, A., & Miao, R. (2010) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2010.5516657 · Cited by 3
Emission of Nitrogen Dioxide from Butane Gas Heaters and Stoves Indoors
Ghosn, M., Flouty, R., & Saliba, N. A. (2005) · American Journal of Applied Sciences · doi:10.3844/ajassp.2005.707.710 · Cited by 3
The Influence of School Environment on the SBS Symptoms and the Development of Asthma and Allergy
Takaoka, M., & Norbäck, D. (2011) · Springer eBooks · doi:10.1007/978-3-642-17919-8_8 · Cited by 3
Evaluation of thermal comfort room garment workshop in textile vocational school
Febiyani, A., Suhardi, B., & Pujiyanto, E. (2018) · IEEE International Conference on Industrial Engineering and Applications (ICIEA) · doi:10.1109/iea.2018.8387097 · Cited by 3
Estudo da Qualidade do Ar Interior num edifício departamental da UC
Costa, C. M. P. (2011) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 3
Indoor and Outdoor Air Pollution in Relation to Allergy and Asthma in Taiyuan, China
Zhao, Z. (2006) · Uppsala University Publications (Uppsala University) · Cited by 3
Avaliação da qualidade ambiental: mercado municipal de São Carlos/SP
Silva, L. D. M. (2012) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.18.2012.tde-06062013-160039 · Cited by 3
Moradnia, M., Darvishmotevalli, M., Attar, H. M., & Hajizadeh, Y. (2023) · Research Square · doi:10.21203/rs.3.rs-3208459/v1 · Cited by 3
Kim, J. (2006) · Uppsala University Publications (Uppsala University) · Cited by 3
Percepção da qualidade do ar interior em salas de aula urbanas: estudo de caso em Vitória-ES
Silva, S. V. D. O., Pagel, É. C., Sarnaglia, A. J. Q., & Velten, F. B. (2024) · Gestão & Tecnologia de Projetos · doi:10.11606/gtp.v19i2.221080 · Cited by 2
A Critical Review on the Indoor Air Quality Status of Schools in India
Vijay, N., & Sarasamma, J. D. (2025) · Current World Environment · doi:10.12944/cwe.19.3.3 · Cited by 2
Exposure of children to aerosol during PE lessons
Šafránek, J., Turčová, I., Braniš, M., & Hájek, M. (2017) · Envigogika · doi:10.14712/18023061.554 · Cited by 2
(2018) · AUSTRALIAN JOURNAL OF BASIC AND APPLIED SCIENCES · doi:10.22587/ajbas.2018.12.12.4 · Cited by 2
Oelßner, W. (2019) · Wiley eBooks · doi:10.1002/9783527688302.ch13 · Cited by 2
Jo, B. J., Ko, Y. K., Oh, Y., & Ko, Y. D. (2024) · Sustainability · doi:10.3390/su16104195 · Cited by 2
A Cost-Effective Methodology for Spatial Concentration Distributions of Urban Air Pollutants
Yannopoulos, P. C. (2014) · Water Air & Soil Pollution · doi:10.1007/s11270-014-1989-7 · Cited by 2
A’yun, Q., Yunardi, R. T., Rizqillah, S. A. N., & Hidayati, U. N. (2021) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/738/1/012004 · Cited by 2
Ai, F. (2010) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 2
Monitoring and assessment of indoor air volatile organic compound concentrations in primary schools
Aslan, G. (2008) · IYTE GCRIS Database (Izmir Institute of Technology) · Cited by 2
Lucas, F., Bozonnet, E., Boulic, M., & Lodzinski, V. (2024) · HAL · Cited by 1
Indoor air quality in the primary school classroom in Poland, case study
Nowak-Dzieszko, K., & Müller, J. (2025) · Archives of Civil Engineering · doi:10.24425/ace.2025.154107 · Cited by 1
Clemêncio, R., Pinto, M., Lopes, S. M. G., & Pinho, P. (2025) · Lecture notes in civil engineering · doi:10.1007/978-3-032-08224-4_57 · Cited by 1
Comparison of Green Building Implementation in Surabaya and Johor Baru
Siswoyo, S., Waskito, J. P. H., Ibrahim, M. H. B. W., Wahab, I. A., & Widiartin, T. (2025) · International Journal of Research in Engineering and Modern Technology (IJREMTE) · doi:10.30742/ijremte.v2i1.11 · Cited by 1
Yan, S., Wang, L. L., Zou, J., Shu, C., Berquist, J., & Zhai, Z. J. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114332 · Cited by 1
Heyat, A., Ahmad, K., Mazhar, M. A., & Alam, P. (2026) · Journal of The Institution of Engineers (India) Series A · doi:10.1007/s40030-026-00954-9 · Cited by 1
Nowak-Dzieszko, K., Mijakowski, M., Müller, J., Kozak-Jagieła, E., & Wargocki, P. L. (2026) · Energies · doi:10.3390/en19112515 · Cited by 1
Assessing indoor air pollution in academic environments: Evidence from schools
Abuelnuor, A. A. A., Abuelnour, M. A., Rikabi, I. J. A., Mohammed, H. A., & Aldabesh, A. D. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.112069 · Cited by 1
สุพรรณสมบูรณ์, ส. (2017) · Built Environment Inquiry · Cited by 1
Saleh, A. D. (2024) · ICTEA: International Conference on Thermal Engineering · Cited by 1
Huang, Y., CHANG, C. F., & Yang, S. (2004) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.06.045 · Cited by 1
Quick and Economic Spatial Assessment of Urban Air Quality
Panayotis, C. (2011) · InTech eBooks · doi:10.5772/22425 · Cited by 1
Santos, P. G. D. L., de Carvalho, R. L. T., & da Silva, A. C. (2015) · Ciência e Natura · doi:10.5902/2179460x13744 · Cited by 1
Personal Exposure of Children to Formaldehyde in Perth, Western Australia
Lazenby, V., Hinwood, A. L., & Franklin, P. (2006) · Epidemiology · doi:10.1097/00001648-200611001-01081 · Cited by 1
Correlation between Indoor Air Distribution and Pollutants in Natural Ventilation
Liu, Z., Li, A., Li, T., & Jiao, X. (2010) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2010.5514673 · Cited by 1
EVALUATION OF INDOOR AIR QUALITY AT FOUR FITNESS FACILITIES
Newcomer, D. A. (2003) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
Moerlein, D. T. (2005) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
Method of Lacquer Products on Emissions of Volatile Organic Compounds
Stachowiak–Wencek, A., & Pradzynski, W. (2015) · Drvna industrija · doi:10.5552/drind.2015.1358 · Cited by 1
Particulate matter characterization in an indoor workplace environment of a landfill
(2015) · Global NEST Journal · doi:10.30955/gnj.001387 · Cited by 1
Multilayer Perceptron-Based Concentration Estimation
Zhang, L., Tian, F., & Zhang, D. D. (2018) · Springer eBooks · doi:10.1007/978-981-13-2167-2_5 · Cited by 1
Chaos-Based Neural Network Optimization Approach
Zhang, L., Tian, F., & Zhang, D. D. (2018) · Springer eBooks · doi:10.1007/978-981-13-2167-2_4 · Cited by 1
Hugosson, K., & Maesel, E. (2020) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 1
Halili, U. Z. A., Ramli, N. A., & Rasli, N. B. I. (2022) · International Journal of Engineering Technologies and Management Research · doi:10.29121/ijetmr.v9.i9.2022.1222 · Cited by 1
The Impact of Air Quality on Schoolchildren
Virgilio, G. D., Hart, M., Maharaj, A. M., & Green, D. (2023) · Routledge eBooks · doi:10.4324/9781003103165-3 · Cited by 1
Indoor Levels of Volatile Organic Compounds at Households in Ulaanbaatar City
Galsuren, J., Dambadarjaa, D., Boldbaatar, B., Erdenechimeg, Z., & Gombojav, E. (2023) · Central Asian Journal of Medical Sciences · doi:10.24079/cajms.2023.06.003 · Cited by 1
Teachers Are Underestimated Interior Designers: A Narrative Literature Review
Xu, L. (2024) · Advances in Education Humanities and Social Science Research · doi:10.56028/aehssr.12.1.623.2024 · Cited by 1
The CO2 Problem: Climate Models vs. Field Measurements
Shanmugam, G. (2024) · Indian Association of Sedimentologists · doi:10.51710/jias.v3i2.401 · Cited by 1
Raysoni, A. U. (2011) · scholarworks - UTEP (The University of Texas at El Paso) · Cited by 1
Quantifying the Performance of Natural Ventilation Windcatchers
Jones, B. (2010) · Brunel University Research Archive (BURA) (Brunel University London) · Cited by 1
Urban, R. C. (2014) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.59.2014.tde-05052014-102228 · Cited by 1
Chen, Y. (2016) · Nottingham ePrints (University of Nottingham) · Cited by 1
Ghazalli, A. J. (2012) · Universiti Putra Malaysia Institutional Repository (Universiti Putra Malaysia) · Cited by 1
Indoor environment quality and adaptive behaviours in primary schools in the UK
Korsavi, S. S. (2020) · Cited by 1
Mallongi, A., Stang, S., Rauf, A. U., & Ratna, D. (2021) · Research Square · doi:10.21203/rs.3.rs-835674/v1 · Cited by 1
Yi, W.-Y., Zhou, Y., Chan, Y.-F., Leung, Y., Woo, K.-S., Che, W., Lau, A. K. H., Chen, J.-M., & Leung, K. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2207.05140 · Cited by 1
Evaluating the emission of air pollutants from different sources
Xiu, M. (2022) · Queensland University of Technology · doi:10.5204/thesis.eprints.235386 · Cited by 1
Deng, X., Duan, X., Lai, C. Y., Chen, S., Schuldenfrei, E., & Jones, P. M. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5243756 · Cited by 1
Qualidade do ar interior em infantários: comparação de ambientes urbanos e rurais
Nunes, R. A. O. (2014) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/dmmk-2s73 · Cited by 1
Swail, H. (2014) · Mspace (University of Manitoba) · Cited by 1
Wpływ wiatru na skuteczności wentylacji grawitacyjnej
Gładyszewska-Fiedoruk, K. (2013) · Technika Chłodnicza i Klimatyzacyjna
Rönmark, E., & Smedje, G. (2010) · Wiley eBooks · doi:10.1002/9780470710425.ch8
The role of school management in promoting healthy learning environments for Grade R learners
Kolokoto, M. G. (2014) · Boloka Institutional Repository (North-west University)
McLeod, J. D. (2008) · OhioLink ETD Center (Ohio Library and Information Network)
EffectsOf Indoor Environmental Quality On The OccupantsOfIslamic University -Gaza Palestine
Islamic University-Gaza (2014)
Irish prison guards call for expansion of methadone access.
Lines, R. (2001) · PubMed
Assessment of Carbon Dioxide Emissions from Traffic and Its Health Impact in Gaza, Palestine
Madhoun, W. A., Mokat, R. M., Heen, Z. H. A., & Isahak, M. (2016)
Experimental Analysis of CO2 Concentration
Zhang, X. D., Wang, C. D., Jin, J., & Li, Y. Z. (2012) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.260-261.993
Indoor Air Quality and Adsorption of Contaminants by Biomass Carbide
Watanabe, H. (2009) · Journal of The Adhesion Society of Japan · doi:10.11618/adhesion.45.485
Evaluation of airborne particles at a local high school
Klender, S. (2014) · OhioLink ETD Center (Ohio Library and Information Network)
Teaching Technique Support System Based on Classroom Indoor Air Quality (IAQ) Analysis
Nazira, A., Nabiha, H. S., & Azhar, A. N. (2016) · UMP Institutional Repository (Universiti Malaysia Pahang)
Leung, M. H., Sciences, E. H. B. S. O. H., & Sidhu, B. (2015) · BCIT Environmental Public Health Journal · doi:10.47339/ephj.2015.113
Priambudi, B., & -, M. E. S. T. (2018) · UMS Library Center of Academic Activities (Universitas Muhammadiyah Surakarta)
Airborne particulate matter in school classrooms of Northern Italy
Rovelli, S., Cattaneo, A., Nuzzi, C. P., Spinazzè, A., Piazza, S., Fanetti, A. C., Carrer, P., & Cavallo, D. M. (2013) · ISEE Conference Abstracts · doi:10.1289/isee.2013.p-1-01-05
Umaroğulları, F., & Aydın, D. (2020) · A/Z ITU journal of Faculty of Architecture · doi:10.5505/itujfa.2020.09475
Awang, N. R., Radzi, N. A. N. M., Yong, T. S., Abas, M. A., Zainordin, N. S., Ramli, N. A., & Ibrahim, N. (2021) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/842/1/012003
Wickremasinghe, H. T., & Kumuduni, W. Y. (2022) · International Journal of Built Environment and Sustainability · doi:10.11113/ijbes.v9.n3.953 · Cited by 1
STUDI PENERAPAN ARSITEKTUR TROPIS PADA KANTOR BUPATI DI KABUPATEN SIKKA
Pangestu, D. M. D., Saladin, A., & Pratiwi, S. N. (2021) · Prosiding Seminar Intelektual Muda · doi:10.25105/psia.v3i1.13066
Indoor gas emission assessment in public schools in Perlis
Zakarya, I. A., Jaafar, M. H., Yunus, M. N. H., Abustan, A. R., & Hamidin, N. (2023) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/1135/1/012039
The Thermal Comfort of Sangkring Art Space Yogyakarta
Hidayati, R., Anugerah, M. K., & Nugrahaini, F. T. (2024) · Lecture notes in civil engineering · doi:10.1007/978-981-99-1111-0_62
Yang, H.-H., Kim, H. J., Bang, S.-W., Cho, H.-W., Park, H., & Kim, H.-H. (2024) · Journal of Odor and Indoor Environment · doi:10.15250/joie.2024.23.4.331
Ramadhan, R. D. A., & Ariestadi, D. (2025) · Semesta Teknika · doi:10.18196/st.v28i1.24720
William Happer, Ph.D. (Princeton): The Consequential Climate Physicist
Shanmugam, G. (2025) · Indian Association of Sedimentologists · doi:10.51710/jias.v4i1.428
Measuring, modelling and mitigating particulate matter in indoor environments
Lowther, S. D. (2022) · Lancaster EPrints (Lancaster University) · doi:10.17635/lancaster/thesis/1705
Meklin, T. (2002) · UEF eRepo (University of Eastern Finland)
Kocaeli’de evlerde, ofislerde ve okullarda iç ortam hava kalitesinin belirlenmesi
Pekey, H., TUNCEL, S. G., Pekey, B., Kuntasal, Ö. O., Zararsız, A., Efe, N., Arslanbaş, D., Bozkurt, Z., Doğan, G., Civan, M., et al. (2008) · OpenMETU (Middle East Technical University)
Qualidade do Ar Interior em Estabelecimentos de Ensino no Douro Sul
Clemêncio, R. A. D. F. (2025) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Development of a model for controlling indoor air quality
Guo, F. (2017) · theses.fr (ABES) · doi:10.70675/b8847bf4z481az41f0z9b4dze7be5d86cf01
Metadata
- Authors
- Lee, S. C., & Chang, M.
- Affiliations
- Hong Kong Polytechnic University (HK)
- Corresponding author
- Lee, S.C
- ORCID
- Lee, S.C
- Venue
- Chemosphere
- Publisher
- Elsevier BV
- Published
- 2000-07
- Volume
- 41
- Issue
- 1-2
- Pages
- 109-113
- ISSN
- 0045-6535 (ISSN-L)
- OpenAlex
- W2043891653
- Cited by
- 356
- References
- 3
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 19 · 2023: 18 · 2022: 17 · 2021: 24 · 2020: 21 · 2019: 18 · 2018: 28 · 2017: 11 · 2016: 11 · 2015: 18 · 2014: 25 · 2013: 17 · 2012: 17
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Chemosphere (publishedVersion)
- PubMed (publishedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor air quality, outdoor air quality, school classrooms, carbon dioxide, ventilation, air conditioning, ceiling fans, respirable particles, PM10, formaldehyde, sulfur dioxide, nitrogen dioxide, nitric oxide, Hong Kong
- MeSH terms
- Air Pollution, Bacteria, Carbon Dioxide, Environmental Monitoring, Formaldehyde, Humans, Humidity, Nitric Oxide, Nitrogen Dioxide, Particle Size, Public Health, Schools, Sulfur Dioxide, Temperature, Ventilation, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.