Indoor and outdoor air quality investigation at schools in Hong Kong
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Five classrooms in Hong Kong (HK), air-conditioned or ceiling fans ventilated, were chosen for investigation of indoor and outdoor air quality. Parameters such as temperature, relative humidity (RH), carbon dioxide (CO2), sulphur dioxide (SO2), nitric oxide (NO), nitrogen dioxide (NO2), respirable particulate matter (PM10), formaldehyde (HCHO), and total bacteria counts were monitored indoors and outdoors simultaneously. The average respirable particulate matter concentrations were higher than the HK Objective, and the maximum indoor PM10 level exceeded 1000 microg/m3. Indoor CO2 concentrations often exceeded 1000 microl/l in air-conditioning and ceiling fan classrooms, indicating inadequate ventilation. Maximum indoor CO2 level reached 5900 microl/l during class at the classroom with cooling tower ventilation. Increasing the rate of ventilation or implementation of breaks between classes is recommended to alleviate the high CO2 level. Other pollution parameters measured in this study complied with the standards. The two most important classroom air quality problems in Hong Kong were PM10 and CO2 levels.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We considered this method because recently ATP levels as the measures of the total microbial activity or microbial load were explored by several researchers in different kinds of clinical or hospital environmental settings [30,31,32], as well as in field experiments on bioaerosol monitoring and evaluation of bioaerosol samplers [33].”
Citations
Cites
Air pollution. Its origin and control
(1977) · Environmental Pollution (1970) · doi:10.1016/0013-9327(77)90079-9 · Cited by 513
Norback, D., Torgen, M., & Edling, C. (1990) · Occupational and Environmental Medicine · doi:10.1136/oem.47.11.733 · Cited by 202
Indoor/Outdoor Air Quality: Reference Pollutant Concentrations in Complaint-Free Residences
Montgomery, D. D., & Kalman, D. A. (1989) · Applied Industrial Hygiene · doi:10.1080/08828032.1989.10389885 · Cited by 44
Research works printed but not linked: 2
- Gusten, 1995, Experiences of measures taken to improve the air quality in schools, Air Infiltration Review, 16, 5
- Koo, L.C.L., Luk, M.Y., Mok, M.Y., Yuen, J.H.F., Yuen, T.Y.S., 1997. Health effects from air conditioning: epidemiologic studies on schools and offices in Hong Kong. In: Proceedings of Indoor and Built Environment Problems in Asia, Kuala Lumpur, Malaysia, pp. 76–86
Cited by
Items 101–200 of 406
Zhao, Z., Elfman, L., Wang, Z. H., Zhang, Z., & Norbäck, D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00433.x · Cited by 67
Laboratory Evaluation of the Alphasenese Opc-N3, and the Plantower Pms5003 and Pms6003 Sensors
Kaur, K., & Kelly, K. E. (2022) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2023.106181 · Cited by 66
Indoor air microbiological evaluation of offices, hospitals, industries, and shopping centers
Nunes, Z. G., Martins, A. S., Altoe, A. L. F., Nishikawa, M. M., Leite, M. O., Aguiar, P. F., & Fracalanzza, S. E. L. (2005) · Memórias do Instituto Oswaldo Cruz · doi:10.1590/s0074-02762005000400003 · Cited by 55
Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong
Guo, H. F., Lee, S., & CHAN, L. (2003) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2003.09.031 · Cited by 65
Self-citationCharacterization of Indoor-Air Bioaerosols in Southern Taiwan
Hsu, Y. C., Kung, P.-Y., Wu, T. N., & Shen, Y.-H. (2012) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.03.0070 · Cited by 64
Gao, X., Wei, J., Lei, H., Xu, P., Cowling, B. J., & Li, Y. (2016) · PLoS ONE · doi:10.1371/journal.pone.0162481 · Cited by 62
Indoor/Outdoor Relationships between PM10 and Associated Organic Compounds in a Primary School
Alves, C. A., Urban, R. C., Pegas, P. N., & Nunes, T. (2014) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2013.04.0114 · Cited by 60
Ventilation of air-conditioned residential buildings: A case study in Hong Kong
Ai, Z., Mak, C. M., Cui, D. J., & Xue, P. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.05.055 · Cited by 60
Can carbon dioxide be used as a tracer of urban atmospheric transport?
Pataki, D. E., Tyler, B. J., Peterson, R. E., Nair, A., Steenburgh, W. J., & Pardyjak, E. R. (2005) · Journal of Geophysical Research Atmospheres · doi:10.1029/2004jd005723 · Cited by 60
Children’s Exposure to Indoor Particulate Matter in Naturally Ventilated Schools in India
Habil, M., & Taneja, A. (2011) · Indoor and Built Environment · doi:10.1177/1420326x11409455 · Cited by 61
Evaluating wind-driven natural ventilation potential for early building design
Cheng, J., Qi, D., Katal, A., Wang, L. L., & Stathopoulos, T. (2018) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/j.jweia.2018.09.017 · Cited by 59
Bhat, M. A., Eraslan, F. N., Awad, A., Malkoç, S., Üzmez, Ö. Ö., Döğeroğlu, T., & Gaga, E. O. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109176 · Cited by 60
Indoor and Outdoor Particulate Matter Concentrations at Schools in the Athens Area
Diapouli, E., Chaloulakou, A., & Spyrellis, N. (2007) · Indoor and Built Environment · doi:10.1177/1420326x06074836 · Cited by 59
Zamani, M. E. (2013) · American Journal of Applied Sciences · doi:10.3844/ajassp.2013.1140.1147 · Cited by 60
Designing Primary Schools for the Future
Darmody, M., Smyth, E., & Doherty, C. (2010) · Arrow@dit (Dublin Institute of Technology) · Cited by 60
Indoor Air Pollution Levels in Decorated Residences and Public Places over Xi’an, China
Chang, T., Ren, D., Shen, Z., Huang, Y. H., Sun, J., Cao, J., Zhou, J., Liu, H., Xu, H., Zheng, C., et al. (2017) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.12.0542 · Cited by 58
Large particles are responsible for elevated bacterial marker levels in school air upon occupation
Fox, A., Harley, W. M., Feigley, C. E., Salzberg, D., Toole, C., Sebastian, A., & Larsson, L. (2005) · Journal of Environmental Monitoring · doi:10.1039/b418038k · Cited by 58
Indoor air quality assessment in painting and printmaking department of a fine arts faculty building
Can, E. K., Üzmez, Ö. Ö., Döğeroğlu, T., & Gaga, E. O. (2015) · Atmospheric Pollution Research · doi:10.1016/j.apr.2015.05.008 · Cited by 56
Shendell, D. G., Barnett, C. L., & Boese, S. (2004) · Journal of School Health · doi:10.1111/j.1746-1561.2004.tb06603.x · Cited by 56
Indoor air quality in new hotels’ guest rooms of the major world factory region
Chan, W., Lee, S.-C., Chen, Y., Mak, B., Wong, K., Chan, C.-S., Zheng, C., & Guo, X. (2009) · International Journal of Hospitality Management · doi:10.1016/j.ijhm.2008.03.004 · Cited by 55
Self-citationA review of research on the impact of the classroom physical environment on schoolchildren's health
Fang, Y., Luo, X., & Lu, J. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105430 · Cited by 55
Vornanen-Winqvist, C., Järvi, K., Andersson, M. A., Ahmed, K., Toomla, S., Mikkola, R., Marik, T., Kredics, L., Salonen, H., & Kurnitski, J. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15071414 · Cited by 55
IndoAirSense: A framework for indoor air quality estimation and forecasting
Sharma, P. K., Mondal, A., Jaiswal, S., Saha, M., Nandi, S., De, T., & Saha, S. (2020) · Atmospheric Pollution Research · doi:10.1016/j.apr.2020.07.027 · Cited by 55
Indoor air quality assessment in child care and medical facilities in Korea
Kabir, E., Kim, K., Sohn, J. R., Kweon, B. Y., & Shin, J. H. (2011) · Environmental Monitoring and Assessment · doi:10.1007/s10661-011-2428-5 · Cited by 55
Nakora, N., Byamugisha, D., & Birungi, G. (2020) · SN Applied Sciences · doi:10.1007/s42452-020-03800-0 · Cited by 54
A novel sensor selection using pattern recognition in electronic nose
Zhang, L., Tian, F., & Pei, G. (2014) · Measurement · doi:10.1016/j.measurement.2014.04.005 · Cited by 53
Indoor air quality in schools of a highly polluted south Mediterranean area
Ruggieri, S., Longo, V., Perrino, C., Canepari, S., Drago, G., L’Abbate, L., Balzan, M. V., Cuttitta, G., Scaccianoce, G., Minardi, R., et al. (2019) · Indoor Air · doi:10.1111/ina.12529 · Cited by 53
Effect of wind on stack ventilation performance
Gładyszewska-Fiedoruk, K., & Gajewski, A. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.05.007 · Cited by 52
Gül, H., Gaga, E. O., Döğeroğlu, T., Özden, Ö., Ayvaz, Ö., Özel, S., & Güngör, G. (2011) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph8041110 · Cited by 51
Marques, G., & Pitarma, R. (2019) · Applied Sciences · doi:10.3390/app9030438 · Cited by 51
Roy, S., Zaman, S. U., Joy, K. S., Jeba, F., Kumar, P., & Salam, A. (2023) · Environmental Research Communications · doi:10.1088/2515-7620/acb90d · Cited by 50
Xu, H., Guinot, B., Niu, X., Cao, J., Ho, K., Zhao, Z., Ho, S. S. H., & Liu, S. (2014) · Environmental Geochemistry and Health · doi:10.1007/s10653-014-9662-z · Cited by 50
Development of a sustainable photocatalytic process for air purification.
Martínez-Montelongo, J. H., Medina-Ramírez, I. E., Romo-Lozano, Y., & Zapien, J. A. (2020) · Chemosphere · doi:10.1016/j.chemosphere.2020.127236 · Cited by 50
Modeling indoor particulate exposures in inner-city school classrooms
Gaffin, J. M., Petty, C. R., Hauptman, M., Kang, C., Wolfson, J. M., Awad, Y. A., Di, Q., Lai, P. S., Sheehan, W. J., Baxi, S. N., et al. (2016) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2016.52 · Cited by 50
Salma, I., Dosztály, K., Borsós, T., Söveges, B., Weidinger, T., Kristóf, G., Peter, N.-K., & Kertész, Z. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.09.070 · Cited by 49
Comparison of indoor air quality in schools: Urban vs. Industrial 'oil & gas' zones in Kuwait
Al-Hemoud, A. M., Al-Awadi, L., Al-Rashidi, M. S., Rahman, K. A., Al-Khayat, A., & Behbehani, W. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.06.001 · Cited by 49
Indoor Air Quality Assessment of Elementary Schools in Curitiba, Brazil
Godoi, R. H. M., Avigo, D., Campos, V. P., Tavares, T. M., de Marchi, M. R. R., van Grieken, R., & Godoi, A. F. L. (2009) · Water Air and Soil Pollution Focus · doi:10.1007/s11267-009-9220-3 · Cited by 48
Braniš, M., Šafránek, J., & Hytychová, A. (2010) · Environmental Science and Pollution Research · doi:10.1007/s11356-010-0405-0 · Cited by 47
Babaoğlu, Ü. T., Sezgin, F. M., & Yag, F. (2019) · Indoor and Built Environment · doi:10.1177/1420326x19855117 · Cited by 47
Wu, M., Zhang, G., Wang, L., Liu, X., & Wu, Z. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph191912895 · Cited by 47
Bacterial aerosols in an urban nursery school in Gliwice, Poland: a case study
Brągoszewska, E., Mainka, A., & Pastuszka, J. S. (2015) · Aerobiologia · doi:10.1007/s10453-015-9419-x · Cited by 45
A Clean Air Plan for Sydney: An Overview of the Special Issue on Air Quality in New South Wales
Paton‐Walsh, C., Rayner, P. J., Simmons, J., Fiddes, S. L., Schofield, R., Bridgman, H. A., Beaupark, S., Broome, R. A., Chambers, S. D., Chang, L. T.-C., et al. (2019) · Atmosphere · doi:10.3390/atmos10120774 · Cited by 45
Indoor air quality in ice skating rinks in Hong Kong
Guo, H. F., Lee, S., & Chan, L. Y. (2003) · Environmental Research · doi:10.1016/s0013-9351(03)00116-6 · Cited by 44
Self-citationWoo, K. S., Chook, P., Hu, Y., Lao, X. Q., Lin, C., Lee, P., Kwok, C., Wei, A., Guo, D., Yin, Y., et al. (2020) · International Journal of Epidemiology · doi:10.1093/ije/dyaa235 · Cited by 42
Son, Y. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.106957 · Cited by 42
Dharmasastha, K., Samuel, D. G. L., Nagendra, S. M. S., & Maiya, M. P. (2022) · Energy and Built Environment · doi:10.1016/j.enbenv.2022.04.003 · Cited by 40
Multi-zone simulation of outdoor particle penetration and transport in a multi-story building
Lee, B. H., Yee, S.-W., Kang, D. H., Yeo, M.-S., & Kim, K. W. (2016) · Building Simulation · doi:10.1007/s12273-016-0340-1 · Cited by 40
Analytical Techniques Used in Monitoring of Atmospheric Air Pollutants
Michulec, M., Wardencki, W., Partyka, M., & Namieśnik, J. (2005) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340500207482 · Cited by 40
Singh, P., Saini, R., & Taneja, A. (2014) · Atmospheric Pollution Research · doi:10.5094/apr.2014.041 · Cited by 39
Characteristics and control strategies of indoor particles: An updated review
Li, J., Fan, G., Ou, Y., & Deng, Q. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113232 · Cited by 37
Particle size distribution and air pollution patterns in three urban environments in Xi’an, China
Niu, X., Guinot, B., Cao, J., Xu, H., & Sun, J. (2014) · Environmental Geochemistry and Health · doi:10.1007/s10653-014-9661-0 · Cited by 37
Huang, H. Z., Cao, J., Lee, S., Zou, C., Chen, X.-X., & Fan, S. (2007) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2007.03.0018 · Cited by 37
Self-citationLin, C.-C., & Peng, C.-K. (2010) · Environmental Engineering Science · doi:10.1089/ees.2010.0175 · Cited by 35
Chen, A., Gall, E. T., & Chang, V. W.-C. (2016) · Environmental Science and Pollution Research · doi:10.1007/s11356-016-6826-7 · Cited by 35
Assimakopoulos, V. D., Bekiari, T., Pateraki, S., Maggos, T., Stamatis, P., Nicolopoulou, P., & Assimakopoulos, M.-N. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.04.249 · Cited by 34
Xu, H., Guinot, B., Shen, Z., Ho, K., Niu, X., Xiao, S., Huang, R., & Cao, J. (2015) · Atmosphere · doi:10.3390/atmos6030361 · Cited by 34
Exposure Assessment for Formaldehyde and Acetaldehyde in the Workplace
Cavalcante, R. M., Seyffert, B. H., D’Oca, M. G. M., do Nascimento, R. F., Campelo, C. S., Pinto, I. S., dos Anjos, F. B., & Costa, A. H. R. (2005) · Indoor and Built Environment · doi:10.1177/1420326x05052564 · Cited by 34
Stabile, L., Buonanno, G., Avino, P., & Fuoco, F. C. (2013) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.12.0339 · Cited by 33
Lung Disease Diagnostic Model Through IgG Sensitization to Microbial Extracellular Vesicles
Yang, J., Hong, G., Kim, Y.-S., Seo, H., Kim, S., McDowell, A., Lee, W. H., Kim, Y.-S., Oh, Y., Cho, Y. S., et al. (2020) · Allergy Asthma and Immunology Research · doi:10.4168/aair.2020.12.4.669 · Cited by 33
Chithra, V. S., & Nagendra, S. M. S. (2014) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2014.894483 · Cited by 33
Aerosolized bacteria and microbial activity in dental clinics during cleaning procedures
Adhikari, A., Kurella, S., Banerjee, P., & Mitra, A. (2017) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2017.09.019 · Cited by 34
Caciora, T. I., Ilieș, A. B., BERDENOV, Z. G., Al-Hyari, H. S., Ilieș, D. C., Safarov, B., Hassan, T. H., Herman, G. V., Hodor, N., Bilalov, B., et al. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1440376 · Cited by 32
Hu, D., Tobón, Y. A., Agostini, A., Grosselin, B., Chen, Y., Robin, C., Yahyaoui, A., Colin, P., Mellouki, A., & Daële, V. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.152271 · Cited by 32
Shum, C., Alipouri, Y., & Zhong, L. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108476 · Cited by 32
Indoor Airborne Microplastics: Human Health Importance and Effects of Air Filtration and Turbulence
Gaylarde, C. C., Neto, J. A. B., & da Fonseca, E. M. (2024) · Microplastics · doi:10.3390/microplastics3040040 · Cited by 32
Zhang, H., Srinivasan, R. S., Yang, X., Ahrentzen, S. B., Coker, E. S., & Alwisy, A. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109643 · Cited by 31
Ayuni, N., Juliana, J., & Ibrahim, M. H. (2014) · Journal of Medical and Bioengineering · doi:10.12720/jomb.3.4.282-287 · Cited by 30
MEASURING INDOOR AIR QUALITY PERFORMANCE IN MALAYSIAN GOVERNMENT KINDERGARTEN
Kamaruzzaman, S. N., & Razak, R. A. (2011) · Journal of Building Performance · Cited by 30
IAQ Evaluation Using an IoT CO2 Monitoring System for Enhanced Living Environments
Marques, G., & Pitarma, R. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-77712-2_112 · Cited by 29
A Dynamic Three-Dimensional Air Pollution Exposure Model for Hong Kong.
Barratt, B., Lee, M., Wong, P. P. Y., Tang, R., Tsui, T. H., Cheng, W., Yang, Y., Lai, P.-C., Tian, L., Thach, T.-Q., et al. (2018) · Research Portal (King's College London) · Cited by 29
Zhong, K., Yang, F., & Kang, Y. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.01.010 · Cited by 28
Indoor Air Quality and Thermal Conditions in a Primary School with a Green Roof System
Barmparesos, N., Assimakopoulos, M.-N., Assimakopoulos, V. D., Loumos, N., Sotiriou, M. A., & Koukoumtzis, A. (2018) · Atmosphere · doi:10.3390/atmos9020075 · Cited by 28
Dust exposure in indoor climbing halls
Weinbruch, S., Dirsch, T., Ebert, M., Hofmann, H., & Kandler, K. (2008) · Journal of Environmental Monitoring · doi:10.1039/b719344k · Cited by 28
Alaidroos, A., Almaimani, A. K., Krarti, M., Dahlan, A. S., & Maddah, R. (2021) · Building Simulation · doi:10.1007/s12273-021-0854-z · Cited by 27
A System Design With Deep Learning and IoT to Ensure Education Continuity for Post-COVID
Aydemir, F., & Arslan, S. (2023) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2023.3245129 · Cited by 27
Investigation of indicators for personal exposure and occupancy in offices by using smart sensors
Yun, S., & Licina, D. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113539 · Cited by 27
PM and CO2 variability and relationship in the different school environments
Lazović, I. M., Jovašević-Stojanović, M., Živković, M., Tasić, V., & Stevanovic, Z. M. (2014) · Chemical Industry and Chemical Engineering Quarterly · doi:10.2298/ciceq140212020l · Cited by 27
Assessment and improvement of indoor environmental quality in a primary school
Ekren, O., Karadeniz, Z. H., Atmaca, İ., Ugranli, T., Sofuoǧlu, S. C., & Toksoy, M. (2017) · Science and Technology for the Built Environment · doi:10.1080/23744731.2016.1251288 · Cited by 27
Bralewska, K., & Rogula–Kozłowska, W. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106935 · Cited by 27
Indoor Air Quality Measurements in the Chemistry Department Building of the University of Athens
Valavanidis, A., & Vatista, M. (2006) · Indoor and Built Environment · doi:10.1177/1420326x06073182 · Cited by 27
Moura, P. C., & Vassilenko, V. (2022) · European Journal of Mass Spectrometry · doi:10.1177/14690667221130170 · Cited by 26
Järvi, K., Vornanen-Winqvist, C., Mikkola, R., Kurnitski, J., & Salonen, H. (2018) · Atmosphere · doi:10.3390/atmos9070270 · Cited by 26
Towards an integrated framework for air quality monitoring and exposure estimation—a review
Singla, S., Bansal, D., Misra, A., & Raheja, G. (2018) · Environmental Monitoring and Assessment · doi:10.1007/s10661-018-6940-8 · Cited by 26
Wangchuk, T., He, C., Dudzińska, M. R., & Morawska, L. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2015.05.004 · Cited by 25
Results of An Indoor Size Fractionated PM School Sampling Program in Libby, Montana
Ward, T. J., Noonan, C. W., & Hooper, K. (2006) · Environmental Monitoring and Assessment · doi:10.1007/s10661-006-9386-3 · Cited by 25
Yao, L., Yang, L., Chen, J., Toda, K., Wang, X., Zhang, J., Yamasaki, D., Nakamura, Y., Sui, X. Y., Zheng, L., et al. (2015) · Chemosphere · doi:10.1016/j.chemosphere.2015.03.026 · Cited by 24
Wang, F., Kang, Z., & Zhou, J. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106308 · Cited by 24
Avella, F., Gupta, A., Peretti, C., Fulici, G., Verdi, L., Belleri, A., & Babich, F. (2021) · Heritage · doi:10.3390/heritage4040191 · Cited by 23
Kovačević, R., Tasić, V., Živković, M., Živković, N., Djordjević, A. V., Manojlović, D., & Jovašević-Stojanović, M. (2014) · Chemical Industry and Chemical Engineering Quarterly · doi:10.2298/ciceq140207013k · Cited by 23
Gładyszewska-Fiedoruk, K. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.06.001 · Cited by 22
Thermal condition and heat exposure within buildings: Case study of a tropical city
Ayanlade, A., Esho, O. M., Popoola, K. O., Jeje, O. D., & Orola, B. A. (2019) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2019.100477 · Cited by 22
Indoor air quality in primary schools in Keçiören, Ankara
Babayiğit, M. A., Bakır, B., Tekbaş, Ö. F., Oğur, R., Kılıç, A., & Ulus, S. (2013) · TURKISH JOURNAL OF MEDICAL SCIENCES · doi:10.3906/sag-1212-22 · Cited by 22
Indoor Air Quality of Typical Malaysian Open-air Restaurants
Yusup, Y., Ahmad, M. I., & Ismail, N. (2014) · Environment and Pollution · doi:10.5539/ep.v3n4p10 · Cited by 22
Jalaludin, J., Nazariah, S. S. N., Suhaimi, N. F., & Akim, A. M. (2014) · American Journal of Applied Sciences · doi:10.3844/ajassp.2014.1616.1630 · Cited by 21
PM10 and Heavy Metals in Suburban and Rural Atmospheric Environments of Northern India
Tyagi, V., Gurjar, B. R., Joshi, N., & Kumar, P. (2011) · Journal of Hazardous Toxic and Radioactive Waste · doi:10.1061/(asce)hz.2153-5515.0000101 · Cited by 20
Source Identification of Indoor Particulate Matter and Health Risk Assessment in School Children
Chithra, V. S., & Madanayak, S. N. S. (2018) · Journal of Hazardous Toxic and Radioactive Waste · doi:10.1061/(asce)hz.2153-5515.0000390 · Cited by 20
Du, B., Reda, I., Licina, D., Kapsis, K., Qi, D., Candanedo, J. A., & Li, T. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.4c02797 · Cited by 19
Microbial exposure and health in schools - effects of moisture damage and renovation
Meklin, T. (2002) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 19
Ventilation Strategies for Highly Occupied Public Environments: A Review
Zhang, Y., Guo, Z., Zhuo, L., An, N., & Han, Y. (2023) · Buildings · doi:10.3390/buildings13071642 · Cited by 18
Rawat, N., & Kumar, P. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.108813 · Cited by 18
Metadata
- Authors
- Lee, S. C., & Chang, M.
- Affiliations
- Hong Kong Polytechnic University (HK)
- Corresponding author
- Lee, S.C
- ORCID
- Lee, S.C
- Venue
- Chemosphere
- Publisher
- Elsevier BV
- Published
- 2000-07
- Volume
- 41
- Issue
- 1-2
- Pages
- 109-113
- ISSN
- 0045-6535 (ISSN-L)
- OpenAlex
- W2043891653
- Cited by
- 356
- References
- 3
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 19 · 2023: 18 · 2022: 17 · 2021: 24 · 2020: 21 · 2019: 18 · 2018: 28 · 2017: 11 · 2016: 11 · 2015: 18 · 2014: 25 · 2013: 17 · 2012: 17
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Chemosphere (publishedVersion)
- PubMed (publishedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor air quality, outdoor air quality, school classrooms, carbon dioxide, ventilation, air conditioning, ceiling fans, respirable particles, PM10, formaldehyde, sulfur dioxide, nitrogen dioxide, nitric oxide, Hong Kong
- MeSH terms
- Air Pollution, Bacteria, Carbon Dioxide, Environmental Monitoring, Formaldehyde, Humans, Humidity, Nitric Oxide, Nitrogen Dioxide, Particle Size, Public Health, Schools, Sulfur Dioxide, Temperature, Ventilation, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.