The DOI matches its Crossref record.
Analysis of aluminium in serum and urine for the biomonitoring of occupational exposure
Abstract
A reliable and sensitive graphite furnace atomic absorption spectrometry (GFAAS) method with Zeeman background correction was developed for the analysis of aluminium in serum and urine in the biological monitoring of aluminium exposure. The method is based on platform atomisation in pyrolytically coated graphite tubes after fourfold dilution with nitric acid. For serum analysis, a matrix matched standard curve is prepared and for urine the method of standard additions is used. The within-run imprecision (C.V.) for serum and urine was 3% and 5%, and the between-day imprecision, 6% and 7.2%, at a concentration level of 4.0 mumol/l. The between-day imprecision for urinary aluminium was 15.7% at a concentration level of 0.24 mumol/l. The detection limits were 0.02 mumol/l for serum and 0.07 mumol/l for urine. During 1 year of participation in TEQAS external quality assessment scheme of the Robens Institute for Health and Safety (Guildford, UK) for serum aluminium the maximum cumulative performance score was achieved. For urinary aluminium a certificate in the external quality control scheme of the German Society of Occupational Medicine was obtained. The mean concentration of aluminium in a non-exposed population, who did not use antacid drugs, was 0.06 mumol/l (S.D. 0.03, range 0.02-0.13, n = 21) in serum, and 0.33 mumol/l (S.D. 0.18, range 0.07-0.82, n = 44) in urine. The upper reference limit for aluminium in a healthy, non-exposed population was estimated to be 0.1 mumol/l in…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The migration of Al from cookware into food increases with the acidity of the food and the duration of exposure (Valkonen and Aitio, 1997; Lin et al. 1997).”
From Aluminium toxicosis: a review of toxic actions and effects (2019) · cites this paper as Valkonen and Aitio, 1997
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 23
- Aitio, 1996, Aluminium, Vol. 2, 1
- Allain, 1979, Determination of aluminium in blood, urine and water by inductively coupled plasma emission spectrometry, Anal. Chem., 51, 2089, 10.1021/ac50049a008 · DOI
- Bradley, 1994, Aluminum determined in plasma and urine by atomic absorption spectroscopy with a transversely heated graphite atomiser furnace, Clin. Chem., 40, 431, 10.1093/clinchem/40.3.431 · DOI
- Cedergren, 1987, Determination of aluminium in biological materials by graphite furnace atomic absorption spectrometry (GFAAS), Pure Appl. Chem., 59, 221, 10.1351/pac198759020221 · DOI
- Gardiner, 1981, Determination of aluminum in blood plasma or serum by electrothermal atomic absorption spectrometry, Anal. Chim. Acta, 128, 57, 10.1016/S0003-2670(01)84083-6 · DOI
- Grandjean, 1992, Reference intervals for trace elements in blood: significance of risk factors, Scand. J. Clin. Lab. Invest., 52, 321, 10.3109/00365519209088366 · DOI
- d'Haese, 1985, Measurement of aluminium in serum, blood, urine and tissues of chronic hemodialyzed patients by use of electrothermal atomic absorption spectrometry, Clin. Chem., 31, 24, 10.1093/clinchem/31.1.24 · DOI
- Hewitt, 1990, Critical appraisal of two methods for determining aluminium in blood samples, Clin. Chem., 36, 1466, 10.1093/clinchem/36.8.1466 · DOI
- House, 1992, Factors affecting plasma aluminum concentrations in non-exposed workers, J. Occup. Med., 34, 1013
- Hänninen, 1994, Internal load of aluminium and the central nervous system function of aluminium welders, Scand. J. Work Environ. Health, 20, 279, 10.5271/sjweh.1397 · DOI
- Johnson, 1992, Determination of aluminum in biological fluids by furnace atomic absorption spectrophotometry, J. Clin. Lab. Anal., 6, 264, 10.1002/jcla.1860060504 · DOI
- Leung, 1982, Improved determination of aluminum in serum and urine with use of a stabilised platform furnace, Clin. Chem., 28, 2139, 10.1093/clinchem/28.10.2139 · DOI
- Mauras, 1985, Automatic determination of aluminium in biological samples by inductively coupled plasma emission spectrometry, Anal. Chem., 57, 1706, 10.1021/ac00285a044 · DOI
- Minoia, 1990, Trace element reference values in tissues from inhabitants of the European Community I. A study of 46 elements in urine, blood and serum of Italian subjects, Sci. Total Environ., 95, 89, 10.1016/0048-9697(90)90055-Y · DOI
- Nagy, 1994, Aluminium dissolved from kitchen utensils, Bull. Environ. Contam. Toxicol., 52, 396, 10.1007/BF00197827 · DOI
- Parkinson, 1982, A method for the routine determination of aluminium in serum and water by flameless atomic absorption spectrometry, Clin. Chim. Acta, 125, 125, 10.1016/0009-8981(82)90189-9 · DOI
- Röllin, 1987, Determination of aluminium in small samples of serum and biopsy samples of bone and soft tissues, Microchem. J., 35, 373, 10.1016/0026-265X(87)90126-3 · DOI
- Sanz-Mendel, 1987, Atomic spectrometric methods (Atomic absorption and inductively coupled plasma atomic emission) for the determination of aluminium at the parts per billion level in biological fluids, J. Anal. Atom. Spectrom., 2, 177, 10.1039/ja9870200177 · DOI
- Sjögren, 1983, Aluminium in the blood and urine of industrially exposed workers, Br. J. Ind. Med., 40, 301
- Sjögren, 1990, Neuropsychiatric symptoms among weiders exposed to neurotoxic metals, Br. J. Ind. Med., 47, 704
- Sjögren, 1996, Effects on the nervous system among welders exposed to aluminium and manganese, Occup. Environ. Med., 53, 32, 10.1136/oem.53.1.32 · DOI
- Taylor, 1992, Measurement of aluminium in clinical samples, Ann. Clin. Biochem., 29, 377, 10.1177/000456329202900402 · DOI
- Wang, 1991, Aluminium levels in normal human serum and urine as determined by Zeeman atomic absorption spectrometry, J. Anal. Toxicol., 15, 57, 10.1093/jat/15.2.66 · DOI
Cited by
Sorted by citations
Human Health Risk Assessment for Aluminium, Aluminium Oxide, and Aluminium Hydroxide
Krewski, D., Yokel, R. A., Nieboer, E., Borchelt, D., Cohen, J., Harry, J., Kacew, S., Lindsay, J., Mahfouz, A. M., & Rondeau, V. (2007) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937400701597766 · Cited by 998
Aluminium toxicosis: a review of toxic actions and effects
Igbokwe, I. O., Igwenagu, E., & Igbokwe, N. A. (2019) · Interdisciplinary Toxicology · doi:10.2478/intox-2019-0007 · Cited by 395
“The mean serum Al level in 44 non-exposed persons who did not use antacids was reported to be 1.6 μg/L (Valkonen and Aitio, 1997) and Chen et al. (2010) reported that values in hemodialysis patients were ten-fold higher than the values in unexposed individuals.”
BackgroundResultInfluential
Metadata
- Authors
- Valkonen, S., & Aitio, A.
- Affiliations
- Finnish Institute of Occupational Health (FI)
- Corresponding author
- Valkonen, Sinikka
- Venue
- Science of The Total Environment
- Publisher
- Elsevier BV
- Published
- 1997-06
- Volume
- 199
- Issue
- 1-2
- Pages
- 103-110
- ISSN
- 0048-9697 (ISSN-L)
- OpenAlex
- W2079979473
- Cited by
- 49
- References
- 0
- Citations by year
- 2026: 1 · 2024: 4 · 2023: 3 · 2022: 3 · 2020: 1 · 2019: 2 · 2017: 1 · 2015: 1 · 2014: 2 · 2013: 1 · 2012: 6
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Science of The Total Environment (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Heavy Metal Exposure and Toxicity
- Life Sciences › Agricultural and Biological Sciences › Plant Science › Aluminum toxicity and tolerance in plants and animals
- Keywords
- aluminum, occupational exposure, biomonitoring, serum aluminum, graphite furnace atomic absorption spectrometry, Zeeman background correction, reference limits, antacids, external quality assessment
- MeSH terms
- Adult, Aluminum, Calibration, Environmental Monitoring, Female, Finland, Graphite, Humans, Male, Metallurgy, Occupational Medicine, Quality Control, Reference Standards, Spectrophotometry, Atomic, Reproducibility of Results, Occupational Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review