Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record, with a small difference in title or year; 37 of the 38 references it cites were found in a registry or an index.

Chapter 8 Quantitation of Protein

Noble, James E., Bailey, Marc J.A. · 2009 · Methods in Enzymology

Abstract

The measurement of protein concentration in an aqueous sample is an important assay in biochemistry research and development labs for applications ranging from enzymatic studies to providing data for biopharmaceutical lot release. Spectrophotometric protein quantitation assays are methods that use UV and visible spectroscopy to rapidly determine the concentration of protein, relative to a standard, or using an assigned extinction coefficient. Methods are described to provide information on how to analyze protein concentration using UV protein spectroscopy measurements, traditional dye-based absorbance measurements; BCA, Lowry, and Bradford assays and the fluorescent dye-based assays; amine derivatization and detergent partition assays. The observation that no single assay dominates the market is due to specific limitations of certain methods that investigators need to consider before selecting the most appropriate assay for their sample. Many of the dye-based assays have unique chemical mechanisms that are prone to interference from chemicals prevalent in many biological buffer preparations. A discussion of which assays are prone to interference and the selection of alternative methods is included.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0076-6879(09)63008-1

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 38 references

Cited by

See all 540

Metadata

Authors
Noble, J. E., & Bailey, M. J. A.
Affiliations
  • National Physical Laboratory (GB)
  • University of Cambridge (GB)
Venue
Methods in Enzymology
Publisher
Elsevier
Published
2009
Volume
463
Pages
73-95
ISSN
0076-6879 (ISSN-L)
OpenAlex
W2294062060
Cited by
492
References
38
Citations by year
2026: 22 · 2025: 38 · 2024: 49 · 2023: 21 · 2022: 22 · 2021: 42 · 2020: 34 · 2019: 28 · 2018: 22 · 2017: 24 · 2016: 34 · 2015: 34 · 2014: 36 · 2013: 29 · 2012: 22
FWCI
21.85
Type
book chapter
Language
en
Open access
closed
Locations
  • Methods in enzymology on CD-ROM/Methods in enzymology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Interaction Studies and Fluorescence Analysis
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein purification and stability
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Structure and Dynamics
Keywords
protein quantification, protein concentration measurement, UV spectrophotometry, BCA assay, Lowry assay, Bradford assay, amine derivatization, assay interference, extinction coefficient
MeSH terms
Algorithms, Amines, Animals, Biochemistry, Colorimetry, Humans, Indicators and Reagents, Luminescent Measurements, Proteins, Quinolines, Rosaniline Dyes, X-Ray Absorption Spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Chapter 8 Quantitation of Protein. https://app.cochat.ai/papers/10.1016/s0076-6879(09)63008-1
The paper
Noble, J. E., & Bailey, M. J. A. (2009). Chapter 8 Quantitation of Protein. Methods in Enzymology. https://doi.org/10.1016/s0076-6879(09)63008-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.