Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 765

The DOI matches its Crossref record.

Efficacy and safety of tenecteplase in combination with enoxaparin, abciximab, or unfractionated heparin: the ASSENT-3 randomised trial in acute myocardial infarction

Open access
·2001·The Lancet

Abstract

BACKGROUND Current fibrinolytic therapies fail to achieve optimum reperfusion in many patients. Low-molecular-weight heparins and platelet glycoprotein IIb/IIIa inhibitors have shown the potential to improve pharmacological reperfusion therapy. We did a randomised, open-label trial to compare the efficacy and safety of tenecteplase plus enoxaparin or abciximab, with that of tenecteplase plus weight-adjusted unfractionated heparin in patients with acute myocardial infarction. METHODS 6095 patients with acute myocardial infarction of less than 6 h were randomly assigned one of three regimens: full-dose tenecteplase and enoxaparin for a maximum of 7 days (enoxaparin group; n=2040), half-dose tenecteplase with weight-adjusted low-dose unfractionated heparin and a 12-h infusion of abciximab (abciximab group; n=2017), or full-dose tenecteplase with weight-adjusted unfractionated heparin for 48 h (unfractionated heparin group; n=2038). The primary endpoints were the composites of 30-day mortality, in-hospital reinfarction, or in-hospital refractory ischaemia (efficacy endpoint), and the above endpoint plus in-hospital intracranial haemorrhage or in-hospital major bleeding complications (efficacy plus safety endpoint). Analysis was by intention to treat. FINDINGS There were significantly fewer efficacy endpoints in the enoxaparin and abciximab groups than in the unfractionated heparin group: 233/2037 (11.4%) versus 315/2038 (15.4%; relative risk 0.74 [95% CI 0.63-0.87], p=0.0002) for enoxaparin, and 223/2017 (11.1%) versus 315/2038 (15.4%; 0.72 [0.61-0.84], p<0.0001) for abciximab. The same was true for the efficacy plus safety endpoint: 280/2037 (13.7%) versus 347/2036 (17.0%; 0.81 [0.70-0.93], p=0.0037) for enoxaparin, and 287/2016 (14.2%) versus 347/2036 (17.0%; 0.84 [0.72-0.96], p=0.01416) for abciximab. INTERPRETATION The tenecteplase plus enoxaparin or abciximab regimens studied here reduce the frequency of ischaemic complications of an acute myocardial infarction. In light of its ease of administration, tenecteplase plus enoxaparin seems to be an attractive alternative reperfusion regimen that warrants further study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0140-6736(01)05775-0

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Venue
The Lancet
Publisher
Elsevier BV
Published
2001-08
Volume
358
Issue
9282
Pages
605-613
ISSN
  • 0099-5355 (ISSN-L)
  • 0140-6736
OpenAlex
W1485646988
Cited by
765
References
0
FWCI
55.33
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.