The DOI matches its Crossref record; the references it cites are not checked yet.
Bionic reconstruction to restore hand function after brachial plexus injury: a case series of three patients
Abstract
Background Brachial plexus injuries can permanently impair hand function, yet present surgical reconstruction provides only poor results. Here, we present for the first time bionic reconstruction; a combined technique of selective nerve and muscle transfers, elective amputation, and prosthetic rehabilitation to regain hand function. Methods Between April 2011, and May 2014, three patients with global brachial plexus injury including lower root avulsions underwent bionic reconstruction. Treatment occurred in two stages; first, to identify and create useful electromyographic signals for prosthetic control, and second, to amputate the hand and replace it with a mechatronic prosthesis. Before amputation, the patients had a specifically tailored rehabilitation programme to enhance electromyographic signals and cognitive control of the prosthesis. Final prosthetic fitting was applied as early as 6 weeks after amputation. Findings Bionic reconstruction successfully enabled prosthetic hand use in all three patients. After 3 months, mean Action Research Arm Test score increased from 5·3 (SD 4·73) to 30·7 (14·0). Mean Southampton Hand Assessment Procedure score improved from 9·3 (SD 1·5) to 65·3 (SD 19·4). Mean Disabilities of Arm, Shoulder and Hand score improved from 46·5 (SD 18·7) to 11·7 (SD 8·42). Interpretation For patients with global brachial plexus injury with lower root avulsions, who have no alternative treatment, bionic reconstruction offers a means to restore hand function…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Invasive recording techniques routinely use peripheral in vivo tissues with electroneurography (ENG)[277,278] and electromyography (EMG),[279,280] which can record peripheral nerve activity and muscle electrical signals respectively.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [280]
Citations
The citation lists are queued
They are fetched later and appear here then.
References 43 · Cited by 152
Research works printed but not linked: 1
- Terzis, 2009, Free muscle transfer in posttraumatic plexopathies: part III. The hand, Plast Reconstr Surg, 124, 1225, 10.1097/PRS.0b013e3181b5a322 · DOI
Metadata
- Authors
- Aszmann, O. C., Roche, A. D., Salminger, S., Paternostro-Sluga, T., Herceg, M., Sturma, A., Hofer, C., & Farina, D.
- Affiliations
- Medical University of Vienna (AT)
- Universitätsmedizin Göttingen (DE)
- Corresponding author
- Aszmann, Oskar C
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2015-05
- Volume
- 385
- Issue
- 9983
- Pages
- 2183-2189
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2113328806
- Cited by
- 152
- References
- 43
- Citations by year
- 2026: 7 · 2025: 11 · 2024: 16 · 2023: 5 · 2022: 9 · 2021: 26 · 2020: 7 · 2019: 20 · 2018: 9 · 2017: 15 · 2016: 19 · 2015: 8
- FWCI
- 17.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- GRO (submittedVersion)
- Funders
- Bundesministerium für Wissenschaft und Forschung
- Rat für Forschung und Technologieentwicklung
- Topics
- Health Sciences › Medicine › Surgery › Nerve Injury and Rehabilitation
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- brachial plexus injury, hand function recovery, myoelectric prosthesis, electromyography, prosthetic rehabilitation, upper limb prosthesis
- MeSH terms
- Adult, Amputation, Surgical, Artificial Limbs, Bionics, Brachial Plexus, Electromyography, Hand, Humans, Male, Treatment Outcome, Muscle, Skeletal, Plastic Surgery Procedures, Recovery of Function, Brachial Plexus Neuropathies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bionic reconstruction to restore hand function after brachial plexus injury: a case series of three patients. https://app.cochat.ai/papers/10.1016/s0140-6736(14)61776-1
- The paper
- Aszmann, O. C., Roche, A. D., Salminger, S., Paternostro-Sluga, T., Herceg, M., Sturma, A., Hofer, C., & Farina, D. (2015). Bionic reconstruction to restore hand function after brachial plexus injury: a case series of three patients. The Lancet. https://doi.org/10.1016/s0140-6736(14)61776-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.