5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Background The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that mortality at 1 year, 2 years, and 3 years is much the same with transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) for high-risk patients with aortic stenosis. We report here the 5-year outcomes.Methods We did this randomised controlled trial at 25 hospitals, in Canada (two), Germany (one), and the USA (23). We used a computer-generated randomisation sequence to randomly assign high-risk patients with severe aortic stenosis to either SAVR or TAVR with a balloon-expandable bovine pericardial tissue valve by either a transfemoral or transapical approach. Patients and their treating physicians were not masked to treatment allocation. The primary outcome of the trial was all-cause mortality in the intention-to-treat population at 1 year, we present here predefined outcomes at 5 years. The study is registered with ClinicalTrials.gov, number NCT00530894.Findings We screened 3105 patients, of whom 699 were enrolled (348 assigned to TAVR, 351 assigned to SAVR). Overall mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 11·7%. At 5 years, risk of death was 67·8% in the TAVR group compared with 62·4% in the SAVR group (hazard ratio 1·04, 95% CI 0·86-1·24; p=0·76). We recorded no structural valve deterioration requiring surgical valve replacement in either group. Moderate or severe aortic regurgitation occurred in 40 (14%) of 280 patients in the TAVR group and two (1%) of 228 in the SAVR group (p<0·0001), and was associated with increased 5-year risk of mortality in the TAVR group (72·4% for moderate or severe aortic regurgitation vs 56·6% for those with mild aortic regurgitation or less; p=0·003).Interpretation Our findings show that TAVR as an alternative to surgery for patients with high surgical risk results in similar clinical outcomes.Funding Edwards Lifesciences.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For patients at high or prohibitive risk of operative mortality, with surgical AVR, TAVR has been a transformative innovation, providing a life-saving treatment for patients who were previously not candidates for AVR”
From Calcific aortic stenosis (2016) · cites this paper as [223]
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationTwo-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Self-citationTranscatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Self-citationRegistry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Kapadia, S. R., Leon, M. B., Makkar, R. R., Tuzcu, E. M., Svensson, L. G., Kodali, S., Webb, J. G., Mack, M. J., Douglas, P. S., Thourani, V. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60290-2 · Cited by 867
Self-citationAthappan, G., Patvardhan, E., Tuzcu, E. M., Svensson, L. G., Lemos, P. A., Fraccaro, C., Tarantini, G., Sinning, J.-M., Nickenig, G., Capodanno, D., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.047 · Cited by 782
Self-citationVascular Complications After Transcatheter Aortic Valve Replacement
Généreux, P., Webb, J. G., Svensson, L. G., Kodali, S. K., Satler, L. F., Fearon, W. F., Davidson, C. J., Eisenhauer, A. C., Makkar, R. R., Bergman, G. W., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.003 · Cited by 518
Self-citationJilaihawi, H., Kashif, M., Fontana, G., Furugen, A., Shiota, T., Friede, G., Makhija, R., Doctor, N., Leon, M. B., & Makkar, R. R. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.045 · Cited by 480
Self-citation
Cited by
Items 301–400 of 1,000
Delirium Incidence and Functional Outcomes After Transcatheter and Surgical Aortic Valve Replacement
Shi, S., Sung, M., Afilalo, J., Lipsitz, L. A., Kim, C. A., Popma, J. J., Khabbaz, K. R., Laham, R. J., Guibone, K. A., Lee, J., et al. (2019) · Journal of the American Geriatrics Society · doi:10.1111/jgs.15867 · Cited by 39
Outcomes of three different new generation transcatheter aortic valve prostheses
Costa, G., Buccheri, S., Barbanti, M., Picci, A., Todaro, D., Simone, E. D., Spina, K. L., D'Arrigo, P., Criscione, E., Nastasi, M., et al. (2019) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.28524 · Cited by 38
A guide for pre-procedural imaging for transcatheter aortic valve replacement patients
Perry, T. E., George, S. A., Lee, B., Wahr, J. A., Randle, D., & Sigurðsson, G. (2020) · Perioperative Medicine · doi:10.1186/s13741-020-00165-1 · Cited by 37
Late stroke after transcatheter aortic valve replacement: a nationwide study
Bjursten, H., Norrving, B. G., & Ragnarsson, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-89217-0 · Cited by 37
Ishizu, K., Shirai, S., Isotani, A., Hayashi, M., Kawaguchi, T., Taniguchi, T., Andò, K., Yashima, F., Tada, N., Yamawaki, M., et al. (2021) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2021.03.027 · Cited by 36
Is bioprosthetic leaflet thrombosis a trigger to valve degeneration?
Doris, M. K., & Dweck, M. R. (2018) · Heart · doi:10.1136/heartjnl-2017-312861 · Cited by 36
Rapid Deployment of Aortic Bioprosthesis in Elderly Patients With Small Aortic Annulus
Théron, A., Gariboldi, V., Grisoli, D., Jaussaud, N., Morera, P., Lagier, D., Leroux, S., Amanatiou, C., Guidon, C., Ribéri, A., et al. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2015.09.024 · Cited by 35
Transcarotid transcatheter aortic valve implantation: multicentre experience in France
Folliguet, T. A., Laurent, N., Bertram, M., Zannis, K., Elfarra, M., Vanhuyse, F., Maureira, P., & Modine, T. (2017) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezx264 · Cited by 37
Subclinical leaflet thrombosis following transcatheter aortic valve replacement
Kanjanauthai, S., Pirelli, L., Nalluri, N., & Kliger, C. (2018) · Journal of Interventional Cardiology · doi:10.1111/joic.12521 · Cited by 37
Woldendorp, K., Doyle, M., Black, D. A., Ng, M. K. C., KEECH, A. C., Grieve, S. M., & Bannon, P. G. (2020) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2020.01.084 · Cited by 35
Quantitative Assessment of Acute Regurgitation Following TAVR
Modolo, R., Chang, C. C., Abdelghani, M., Kawashima, H., Ono, M., Tateishi, H., Miyazaki, Y., Pighi, M., Wykrzykowska, J. J., de Winter, R. J., et al. (2020) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.03.002 · Cited by 36
Leary, M. C., & Varade, P. (2020) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-020-01033-7 · Cited by 38
Hosseinpour, A., Gupta, R., Kamalpour, J., Hosseinpour, H., Chaturvedi, A., Agrawal, A., Patel, N. C., & Patel, C. (2023) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2023.07.100 · Cited by 37
Instenes, I., Gjengedal, E., Eide, L. S. P., Kuiper, K. K. J., Ranhoff, A. H., & Norekvål, T. M. (2017) · Heart Lung and Circulation · doi:10.1016/j.hlc.2017.02.012 · Cited by 35
Vemulapalli, S., Holmes, D. R., Dai, D. W. H., Matsouaka, R., Mack, M. J., Grover, F. L., Makkar, R., Thourani, V. H., & Douglas, P. S. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.09.005 · Cited by 35
“In this real-world analysis of a large group of patients undergoing TAVR with commercially approved devices in the United States, we found that (1) the incidence of”
BackgroundMethodSelf-citationPineda, A. M., Harrison, J. K., Kleiman, N. S., Reardon, M. J., Conte, J. V., O’Hair, D. P., Chetcuti, S. J., Huang, J., Yakubov, S. J., Popma, J. J., et al. (2018) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27928 · Cited by 36
“The principal findings of this analysis are: (1) moderate to severe CKD was frequent, being present in over 60% of high or extreme-risk TAVR and high-risk SAVR patients in the present study; (2) in high-risk patients with moderate/severe CKD, TAVR provided better clinical outcomes when compared with SAVR, with a signi…”
ResultAntithrombotic therapy in patients undergoing transcatheter aortic valve implantation
Nijenhuis, V. J., Brouwer, J., Søndergaard, L., Collet, J., Grove, E. L., & ten Berg, J. M. (2019) · Heart · doi:10.1136/heartjnl-2018-314313 · Cited by 35
Koo, H. J., Choe, J., Kang, D., Ko, E., Ahn, J., Park, D., Park, S., Kim, H. J., Kim, J. B., Choo, S. J., et al. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.11.015 · Cited by 34
Østergaard, L., Lauridsen, T. K., Iversen, K. K., Bundgaard, H., Søndergaard, L., Ihlemann, N., Moser, C. E., & Fosbøl, E. L. (2020) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2020.01.028 · Cited by 36
Girdauskas, E., Owais, T., Fey, B., Kuntze, F., Lauer, B., Borger, M. A., Conradi, L., Reichenspurner, H. C., & Kuntze, T. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw252 · Cited by 34
Basra, S. S., Gopal, A., Hebeler, K. R., Baumgarten, H., Anderson, A., Potluri, S. P., Brinkman, W. T., Szerlip, M., Gopal, D., Filardo, G., et al. (2018) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2018.05.100 · Cited by 34
Self-citationKittleson, M. M., Breathett, K. K., Ziaeian, B., Aguilar, D. A., Blumer, V. L., Bozkurt, B., Diekemper, R. L., Dorsch, M. P., Heidenreich, P. A., Jurgens, C. Y., et al. (2024) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/hcq.0000000000000132 · Cited by 36
Harbaoui, B., Montoy, M., Charles, P., Boussel, L., Liebgott, H., Girerd, N., Courand, P., & Lantelme, P. (2016) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2016.01.013 · Cited by 35
Eide, L. S. P., Ranhoff, A. H., Fridlund, B., Haaverstad, R., Hufthammer, K. O., Kuiper, K. K. J., Nordrehaug, J. E., & Norekvål, T. M. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012683 · Cited by 36
“LSPE, TMN and KOH had full access to all of the data (including statistical reports and tables) in the study and take responsibility for the integrity of the data and the accuracy of the data analysis.”
MethodEarly readmissions after transcatheter and surgical aortic valve replacement
Vejpongsa, P., Bhise, V., Charitakis, K., Anderson, H. V., Balan, P., Nguyen, T. C., Estrera, A. L., Smalling, R. W., & Dhoble, A. (2017) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26945 · Cited by 35
Vascular complications of transcatheter aortic valve replacement: A concise literature review
Chaudhry, M. A., & Sardar, M. R. (2017) · World Journal of Cardiology · doi:10.4330/wjc.v9.i7.574 · Cited by 33
Tarantini, G., Purita, P., D’Onofrio, A., Fraccaro, C., Frigo, A. C., D’Amico, G., Fovino, L. N., Martín, M. J., Cardaioli, F., Badawy, M. R. A., et al. (2017) · Annals of Cardiothoracic Surgery · doi:10.21037/acs.2017.08.02 · Cited by 33
“Similar results were observed in the 5-year analysis of the PARTNER 1 trial, in which over 2/3 of deaths were non-cardiovascular (8).”
Long-term Hospital Readmissions After Surgical Vs Transcatheter Aortic Valve Replacement
Bianco, V. J., Kilic, A., Gleason, T. G., Lee, J. S., Schindler, J. T., Aranda-Michel, E. C., Wang, Y., Navid, F., Kliner, D., Cavalcante, J. L., et al. (2019) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2019.03.077 · Cited by 33
Inoue, S., Nakao, K., Hanyu, M., Hayashida, K., Shibahara, H., Kobayashi, M., Asaoka, M., Nishikawa, K., Clancy, S., Koshiishi, J., et al. (2019) · Value in Health Regional Issues · doi:10.1016/j.vhri.2019.07.013 · Cited by 36
Al‐Rashid, F., Totzeck, M., Saur, N., Jánosi, R. A., Lind, A. Y., Mahabadi, A. A., Rassaf, T., & Mincu, R. (2020) · BMC Cardiovascular Disorders · doi:10.1186/s12872-020-01556-4 · Cited by 33
Testa, L., Agnifili, M., Mieghem, N. M. V., Tchétché, D., Asgar, A., Backer, O. D., Latib, A., Reimers, B., Stefanini, G. G., Trani, C., et al. (2021) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.120.010440 · Cited by 33
Redo TAVI: initial experience at two German centres
Schmidt, T., Frerker, C., Alessandrini, H., Schlüter, M., Kreidel, F., Schäfer, U., Thielsen, T., Kück, K., Jose, J., Holy, E. W., et al. (2016) · EuroIntervention · doi:10.4244/eijv12i7a144 · Cited by 33
Donnellan, E., Griffin, B. P., Johnston, D. R., Popović, Z., Alashi, A., Kapadia, S. R., Tuzcu, E. M., Krishnaswamy, A., Mick, S., Svensson, L. G., et al. (2018) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2018.04.019 · Cited by 33
Self-citationReindl, M., Lechner, I., Holzknecht, M., Tiller, C., Fink, P., Oberhollenzer, F., von der Emde, S., Pamminger, M., Troger, F., Kremser, C., et al. (2023) · Circulation · doi:10.1161/circulationaha.123.066498 · Cited by 32
Baron, S. J., Arnold, S. V., Reynolds, M. R., Wang, K., Deeb, M., Reardon, M. J., Hermiller, J. B., Yakubov, S. J., Adams, D. H., Popma, J. J., et al. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.08.006 · Cited by 34
“functional status in extreme-risk and high-risk patients beyond 1 year, these studies have almost exclusively relied on physician-reported surrogates for health status, such as NYHA classification (which has been shown to be an unreliable measure of functional status due to limited inter-rater as well as intra-rater r…”
Infectious Endocarditis After Transcatheter Aortic Valve Replacement: Epidemiology and Outcomes
Kuttamperoor, F., Yandrapalli, S., Siddhamsetti, S., Frishman, W. H., & Tang, G. H. L. (2019) · Cardiology in Review · doi:10.1097/crd.0000000000000244 · Cited by 34
Harjai, K. J., Bules, T., Berger, A. L., Young, B., Singh, D. N., Carter, R., Agarwal, S., Crockett, S., Mascarenhas, V., Nawaz, Y., et al. (2020) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2020.01.002 · Cited by 32
Anam, S. B., Kovarovic, B. J., Ghosh, R. P., Bianchi, M., Hamdan, A., Haj-Ali, R. M., & Bluestein, D. (2021) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-021-10191-z · Cited by 35
“Clinical studies, including a 5-year follow-up study of PARTNER 1 trial, indicated that even the presence of mild post-TAVR PVL was associated with impaired survival [35, 36], which highlights the importance of analyzing the risk associated with mild PVL.”
BackgroundIshizu, K., Shirai, S., Tashiro, H., Kitano, K., Tabata, H., Nakamura, M., Morofuji, T., Murakami, N., Morinaga, T., Hayashi, M., et al. (2022) · Journal of the American Heart Association · doi:10.1161/jaha.122.026294 · Cited by 32
Morphology, Clinicopathologic Correlations, and Mechanisms in Heart Valve Health and Disease
Schöen, F. J. (2016) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-016-0277-7 · Cited by 42
Radiographic Review of Current Therapeutic and Monitoring Devices in the Chest
Sigakis, C. J. G., Mathai, S. K., Suby-Long, T. D., Restauri, N., Ocazionez, D., Bang, T. J., Restrepo, C. S., Sachs, P. B., & Vargas, D. (2018) · Radiographics · doi:10.1148/rg.2018170096 · Cited by 32
Fu, J., Popal, M. S., Li, Y., Li, G., Qi, Y., Fang, F., Kwong, J. S. W., You, B., Meng, X., & Du, J. (2019) · Journal of Thoracic Disease · doi:10.21037/jtd.2019.04.97 · Cited by 31
Stent and leaflet stresses in 26-mm, third-generation, balloon-expandable transcatheter aortic valve
Xuan, Y., Dvir, D., Wang, Z., Mizoguchi, T., Ye, J., Guccione, J. M., Ge, L., & Tseng, E. E. (2018) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2018.04.115 · Cited by 32
Melidi, E., Latsios, G., Toutouzas, K., Vavouranakis, M., Tolios, I., Gouliami, M., Gerckens, U. J., & Tousoulis, D. (2016) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2016.10.001 · Cited by 34
“Longer followup data from this trial have shown that at 5 years, the rates of stroke in both the TAVI and SAVR populations are equal.(60) Data from available trials and studies have not shown any association between the types of anesthesia and the rates of strokeafter TAVI.”
ResultSawaya, F., Spaziano, M., Lefèvre, T., Roy, A. K., Garot, P., Hovasse, T., Neylon, A. M., Benamer, H., Romano, M., Unterseeh, T., et al. (2016) · World Journal of Cardiology · doi:10.4330/wjc.v8.i12.735 · Cited by 36
Pathology of balloon‐expandable transcatheter aortic valves
Yahagi, K., Ladich, E. R., Kutys, R., Mori, H., Svensson, L. G., Mack, M. J., Herrmann, H. C., Smith, C. R., Leon, M. B., Virmani, R., et al. (2017) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27160 · Cited by 31
Self-citationMatching patients with the ever-expanding range of TAVI devices
Jones, B., Krishnaswamy, A., Tuzcu, E. M., Mick, S., Jaber, W. A., Svensson, L. G., & Kapadia, S. R. (2017) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.82 · Cited by 35
Self-citationBendary, A., Ramzy, A., Bendary, M. M., & Salem, M. (2020) · Open Heart · doi:10.1136/openhrt-2019-001131 · Cited by 31
Buzzatti, N., Bonis, M. D., & Moat, N. E. (2017) · Interventional Cardiology Clinics · doi:10.1016/j.iccl.2017.08.005 · Cited by 31
Shinn, S. H., Altarabsheh, S. E., Deo, S. V., Sabik, J. H., Markowitz, A., & Park, S. J. (2018) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2018.03.059 · Cited by 31
“On one hand, TAVI has some benefit with regards to early survival and functional status compared with surgical AVR [17] but still has drawbacks such as PVL and higher rate of pacemaker insertion [11].”
BackgroundTranscatheter Aortic Valve Replacement in Intermediate‐ and Low‐Risk Patients
Rogers, T., Thourani, V. H., & Waksman, R. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.117.007147 · Cited by 33
Self-citationBuzzatti, N., Denti, P., Scarfò, I. S., Giambuzzi, I., Schiavi, D., Ruggeri, S., Castiglioni, A., Bonis, M. D., Canna, G. L., & Alfieri, O. (2018) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.28029 · Cited by 32
“The survival found in our series recalls the early results of transcatheter aortic valve implantation, which were closely linked to the patients' sick baseline profile.(12) Recently, the German TRAMI Registry reported an overall 4-year observed survival after MitraClip of 46.”
ResultSutureless aortic valve prostheses
Bilkhu, R., Borger, M. A., Briffa, N. P., & Jahangiri, M. (2019) · Heart · doi:10.1136/heartjnl-2018-313513 · Cited by 31
Stachon, P., Kaier, K., Zirlik, A., Bothe, W., Heidt, T., Zehender, M., Bode, C., & Mühlen, C. V. Z. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.118.011504 · Cited by 34
Sengupta, A., Zaid, S., Kamioka, N., Terré, J. A., Miyasaka, M., Hirji, S. A., Hensey, M., Geloo, N., Petrossian, G., Robinson, N. B., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.08.042 · Cited by 32
Self-citationScialla, S., Martuscelli, G., Nappi, F., Singh, S., Iervolino, A., Larobina, D., Ambrosio, L., & Raucci, M. G. (2021) · Polymers · doi:10.3390/polym13101556 · Cited by 32
“A very low rate of infection was described in the pilot PARTNER randomized trial [26,27].”
BackgroundHioki, H., Watanabe, Y., Kozuma, K., Yamamoto, M., Naganuma, T., Araki, M., Tada, N., Shirai, S., Yamanaka, F., Higashimori, A., et al. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.04.005 · Cited by 30
Gassa, A., Borghardt, J. H., Maier, J., Kuhr, K., Michel, M., Ney, S., Eghbalzadeh, K., Sabashnikov, A., Rudolph, T. K., Baldus, S. E., et al. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2018.11.30 · Cited by 30
“Transaortal approach 3 [6] 11 [3] Data are presented as number [percentage] for categorical variables, mean standard deviation for normally distributed or median and (25 and 75 percentile) for not normally distributed continuous variables.”
BackgroundTarride, J., Luong, T., Goodall, G., Burke, N., & Blackhouse, G. (2019) · ClinicoEconomics and Outcomes Research · doi:10.2147/ceor.s208107 · Cited by 35
Rheude, T. A., Pellegrini, C., Cassese, S., Wiebe, J., Wagner, S., Trenkwalder, T., Alvarez, H., Mayr, N. P., Hengstenberg, C., Schunkert, H., et al. (2020) · EuroIntervention · doi:10.4244/eij-d-19-00710 · Cited by 30
A Finite Element Analysis Study from 3D CT to Predict Transcatheter Heart Valve Thrombosis
Nappi, F., Mazzocchi, L., Timofeva, I., Macron, L., Morganti, S., Singh, S., Attias, D., Congedo, A., & Auricchio, F. (2020) · Diagnostics · doi:10.3390/diagnostics10040183 · Cited by 31
Kim, W., Bhumimuang, K., Renker, M., Fischer‐Rasokat, U., Möllmann, H., Walther, T., Choi, Y., NEF, H. M., & Hamm, C. W. (2021) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeab011 · Cited by 30
Desai, M. Y., Alashi, A., Popović, Z., Wierup, P. N., Griffin, B. P., Thamilarasan, M., Johnston, D. R., Svensson, L. G., Lever, H. M., & Smedira, N. G. (2021) · Journal of the American Heart Association · doi:10.1161/jaha.120.018435 · Cited by 33
Self-citationErdoes, G., Lippuner, C., Kocsis, I., Schiff, M., Stucki, M., Carrel, T. P., Windecker, S., Eberle, B., Stueber, F., & Book, M. (2015) · PLoS ONE · doi:10.1371/journal.pone.0143089 · Cited by 34
“The best valve replacement technique for patients with symptomatic severe aortic stenosis (AS) is currently under discussion, particularly as robust evidence suggests that surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) show comparable clinical outcomes in patients at high s…”
BackgroundSola, M., Ramm, C. J., Kolarczyk, L. M., Teeter, E. G., Yeung, M., Caranasos, T. G., & Vavalle, J. P. (2016) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2016.05.015 · Cited by 31
Tung, M., Wang, X., Li, F. Y., Wang, H., Guo, Y., Wang, C., Wei, L., Luo, X., Wang, X., & Wang, W. (2018) · Journal of Cardiology · doi:10.1016/j.jjcc.2018.05.020 · Cited by 30
Kittleson, M. M., Breathett, K. K., Ziaeian, B., Aguilar, D. A., Blumer, V. L., Bozkurt, B., Diekemper, R. L., Dorsch, M. P., Heidenreich, P. A., Jurgens, C. Y., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.05.014 · Cited by 31
Wöhrle, J., Rodewald, C., & Rottbauer, W. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26062 · Cited by 30
Burrage, M. K., Moore, P., Cole, C. M. W., Cox, S. V., Lo, W. C., Rafter, A., Garlick, B., Garrahy, P., Mundy, J. A., & Camuglia, A. C. (2016) · Heart Lung and Circulation · doi:10.1016/j.hlc.2016.07.011 · Cited by 31
Handa, N., Kumamaru, H., Torikai, K., Kohsaka, S., Takayama, M., Kobayashi, J., Ogawa, H., Shirato, H., Ishii, K., Koike, K., et al. (2018) · Circulation Journal · doi:10.1253/circj.cj-18-0211 · Cited by 31
“These included (1) controlled site selection with site qualification endorsed by both cardiovascular and surgical academic societies, (2) an on-site proctoring/training program provided by the manufacturers and (3) the development of a TAVI national registry (J-TVT) by academic societies in collaboration with the Phar…”
How Transcatheter Aortic Valve Implantation (TAVI) Was Born: The Struggle for a New Invention
Andersen, H. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.722693 · Cited by 32
Steffen, J., Stocker, A., Scherer, C., Haum, M., Fischer, J., Doldi, P. M., Theiss, H. D., Braun, D., Rizas, K. D., Peterß, S., et al. (2022) · European Heart Journal Acute Cardiovascular Care · doi:10.1093/ehjacc/zuac131 · Cited by 34
Yokoyama, H., Sugiyama, Y., Miyashita, H., Jalanko, M., Ochiai, T., Shishido, K., Yamanaka, F., Vähäsilta, T., Saito, S., Laine, M., et al. (2023) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2022.12.002 · Cited by 32
Multimorbidity in Older Adults with Aortic Stenosis
Lindman, B. R., & Patel, J. N. (2016) · Clinics in Geriatric Medicine · doi:10.1016/j.cger.2016.01.006 · Cited by 40
“Nevertheless, it was associated with a 2-fold greater adjusted hazard of mortality in the overall study cohort treated with surgical AVR or TAVR.(45) Other studies have demonstrated that liver disease is associated with increased risk of early mortality after TAVR.”
BackgroundTranscatheter Treatment of Bicuspid Aortic Valve Disease: Imaging and Interventional Considerations
Das, R., & Puri, R. (2018) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2018.00091 · Cited by 29
Bioprosthetic structural valve deterioration: How do TAVR and SAVR prostheses compare?
Aldalati, O., Kaura, A., Khan, H., Dworakowski, R., Byrne, J., Eskandari, M., Deshpande, R. P., Monaghan, M. J., Wendler, O., & MacCarthy, P. A. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.04.091 · Cited by 29
Insights into permanent pacemaker implantation following TAVR in a real-world cohort
Tichelbäcker, T., Bergau, L., Puls, M., Friede, T., Mütze, T., Maier, L. S., Frey, N., Hasenfuss, G. P., Zabel, M., Jacobshagen, C., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204503 · Cited by 30
Osman, M., Ghaffar, Y. A., Foster, T. J., Osman, K., Alqahtani, F., Shah, K. B., Kheiri, B., & Alkhouli, M. A. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.05.006 · Cited by 31
Osman, M., Ghaffar, Y. A., Saleem, M., Kheiri, B., Osman, K., Munir, M. B., & Alkhouli, M. A. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.07.028 · Cited by 31
Miura, M., Yamaji, K., Shirai, S., Hayashi, M., Kawaguchi, T., Arai, Y., Sakaguchi, G., Andò, K., Naganuma, T., Mizutani, K., et al. (2019) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2019.12.022 · Cited by 30
Goudzwaard, J. A., de Ronde, M., van Hoorn, F. E. D., Kwekkeboom, E. H. C., Lenzen, M. J., van Wiechen, M. P. H., Ooms, J. F., Nuis, R.-J. M., Mieghem, N. M. V., Daemen, J., et al. (2020) · Age and Ageing · doi:10.1093/ageing/afaa071 · Cited by 33
TAVR Prognosis, Aging, and the Second TAVR Tsunami
Carroll, J. D. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.08.005 · Cited by 29
Zhou, Y., Wang, Y., Wu, Y., & Zhu, J. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.11.262 · Cited by 28
“As randomized trials have demonstrated comparable results between TAVR and SAVR in the high-risk population [4], there is now a clear trend towards performing”
ResultRogers, T., Torguson, R., Bastian, R. S., Corso, P. J., & Waksman, R. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.03.008 · Cited by 28
Indolfi, C., Bartorelli, A. L., Berti, S. L., Golino, P., Esposito, G., Musumeci, G., Petronio, S., Tamburino, C., Tarantini, G., Ussia, G. P., et al. (2018) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000636 · Cited by 31
Kamioka, N., Arita, T., Hanyu, M., Hayashi, M., Watanabe, S., Miura, S., Isotani, A., Arai, Y., Kakumoto, S., Andò, K., et al. (2018) · International Heart Journal · doi:10.1536/ihj.17-656 · Cited by 28
Impact of Perioperative Stroke on Midterm Outcomes After Transcatheter Aortic Valve Replacement
Habertheuer, A., Gleason, T. G., Kilic, A., Schindler, J. T., Kliner, D., Bianco, V. J., Toma, C., Aranda-Michel, E. C., Kacin, A. J., & Sultan, I. S. (2020) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2020.01.074 · Cited by 28
Ler, A. A. L., Ying, Y. J., Sazzad, F., Choong, A. M. T. L., & Kofidis, T. (2020) · Journal of Cardiothoracic Surgery · doi:10.1186/s13019-020-01170-7 · Cited by 30
“This could be indicative of TAVR valves being more susceptible to SVD and hence potentially less durable in the long term than SAVR valves.”
ResultInfluentialThourani, V. H., Edelman, J. J., Holmes, S. D., Nguyen, T. C., Carroll, J. D., Mack, M. J., Kapadia, S. R., Tang, G. H. L., Kodali, S., Kaneko, T., et al. (2021) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1177/1556984520978316 · Cited by 28
Self-citationSurgical Ablation of Cardiac Tissue with Nanosecond Pulsed Electric Fields in Swine
Varghese, F., Philpott, J. M., Neuber, J., Hargrave, B., & Zemlin, C. W. (2022) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-022-00634-2 · Cited by 28
Asymmetrical Expansion of Balloon-Expandable Transcatheter Aortic Valve Prostheses
Maznyczka, A., Heg, D., Tomii, D., Nakase, M., Bække, P. S., Lanz, J., Stortecky, S., Reineke, D., Windecker, S., & Pilgrim, T. (2024) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2024.05.039 · Cited by 28
Cardiovascular Surgery in the Elderly
Yaffee, D. W., & Williams, M. R. (2016) · Seminars in Thoracic and Cardiovascular Surgery · doi:10.1053/j.semtcvs.2016.08.007 · Cited by 32
Self-citationAutopsy after transcatheter aortic valve implantation
van Kesteren, F., Wiegerinck, E. M. A., Rizzo, S., Baan, J., Planken, R. N., von der Thüsen, J. H., Niessen, H. W. M., van Oosterhout, M. F. M., Pucci, A., Thiene, G., et al. (2017) · Archiv für Pathologische Anatomie und Physiologie und für Klinische Medicin · doi:10.1007/s00428-017-2076-4 · Cited by 32
“For patients considered to be at high or prohibitive risk for conventional cardiac surgery, transcatheter aortic valve implantation (TAVI) evolved as an alternative, less invasive treatment [1, 7, 12].”
Optimization of a Transcatheter Heart Valve Frame Using Patient-Specific Computer Simulation
Rocatello, G., Santis, G. D., Bock, S. D., Beule, M. D., Segers, P., & Mortier, P. (2019) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-019-00420-7 · Cited by 29
Recent advances in aortic valve replacement
Spadaccio, C., Alkhamees, K., & Al‐Attar, N. (2019) · F1000Research · doi:10.12688/f1000research.17995.1 · Cited by 30
Hirji, S. A., McCarthy, E. P., Kim, D. H., McGurk, S., Ejiofor, J. I., Val, F. R. D., Kolkailah, A. A., ROSNER, B. A., Shook, D. C., Nyman, C. B., et al. (2020) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.09.048 · Cited by 28
Elgendy, I. Y., Gad, M. M., Mahmoud, A. N., Dvir, D., Kapadia, S. R., Alfonso, F., & Capodanno, D. (2020) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2020.05.007 · Cited by 29
Self-citationAuer, J., Krotka, P., Reichardt, B., Traxler, D., Wendt, R. T., Mildner, M., Ankersmit, H. J., & Graf, A. C. (2024) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezae214 · Cited by 29
González‐Saldívar, H., Pascual, C., de la Morena, G., Fernández‐Golfín, C., Amorós, C., Alonso, M. B., Martínez‐Dolz, L., Ariza‐Solé, A., Guzmán, G., Gómez‐Doblas, J. J., et al. (2016) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2016.04.044 · Cited by 29
Subclinical leaflet thrombosis after transcatheter aortic valve implantation
Nakatani, S. (2017) · Heart · doi:10.1136/heartjnl-2017-311818 · Cited by 27
Metadata
- Authors
- Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., Kodali, S. K., Makkar, R. R., Fontana, G. P., Kapadia, S., Bavaria, J., Hahn, R. T., Thourani, V. H., Babaliaros, V., Pichard, A., Herrmann, H. C., Brown, D. L., Williams, M., Davidson, M. J., Svensson, L. G., & Akin, J.
- Affiliations
- Baylor Scott & White Health (US)
- NewYork–Presbyterian Hospital (US)
- Stanford Medicine (US)
- Cleveland Clinic (US)
- St. Paul's Hospital (CA)
- Duke Medical Center (US)
- Cedars-Sinai Medical Center (US)
- Lenox Hill Hospital (US)
- University of Pennsylvania (US)
- Emory University (US)
- MedStar Washington Hospital Center (US)
- Heart Hospital Baylor Plano (US)
- NYU Langone Health (US)
- Brigham and Women's Hospital (US)
- Corresponding author
- Mack, Michael J
- ORCID
- Mack, Michael J
- Leon, Martin B
- Smith, Craig R
- Miller, D Craig
- Moses, Jeffrey W
- Tuzcu, E Murat
- Webb, John G
- Douglas, Pamela S
- Anderson, William N
- Blackstone, Eugene H
- Kodali, Susheel K
- Makkar, Raj R
- Fontana, Gregory P
- Kapadia, Samir
- Bavaria, Joseph
- Hahn, Rebecca T
- Thourani, Vinod H
- Babaliaros, Vasilis
- Herrmann, Howard C
- Brown, David L
- Williams, Mathew
- Svensson, Lars G
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 385
- Issue
- 9986
- Pages
- 2477-2484
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2067905792
- Cited by
- 1,739
- References
- 31
- Citations by year
- 2026: 55 · 2025: 122 · 2024: 140 · 2023: 110 · 2022: 120 · 2021: 158 · 2020: 189 · 2019: 186 · 2018: 188 · 2017: 208 · 2016: 188 · 2015: 64
- FWCI
- 157.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Boston Scientific Corporation
- Medtronic
- Abbott Vascular
- St. Jude Medical
- National Heart, Lung, and Blood Institute (67025)
- Edwards Lifesciences
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- transcatheter aortic valve implantation, surgical aortic valve replacement, aortic stenosis, high-risk surgical patients, five-year outcomes, all-cause mortality, aortic regurgitation, transapical approach, transfemoral access, PARTNER trial, structural valve deterioration
- MeSH terms
- Aged, Aged, 80 and over, Aortic Valve, Aortic Valve Insufficiency, Aortic Valve Stenosis, Canada, Cause of Death, Female, Follow-Up Studies, Germany, Humans, Male, United States, Comorbidity, Survival Rate, Survival Analysis, Treatment Outcome, Heart Valve Prosthesis Implantation, Transcatheter Aortic Valve Replacement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.