Abstract
Background The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that mortality at 1 year, 2 years, and 3 years is much the same with transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) for high-risk patients with aortic stenosis. We report here the 5-year outcomes.Methods We did this randomised controlled trial at 25 hospitals, in Canada (two), Germany (one), and the USA (23). We used a computer-generated randomisation sequence to randomly assign high-risk patients with severe aortic stenosis to either SAVR or TAVR with a balloon-expandable bovine pericardial tissue valve by either a transfemoral or transapical approach. Patients and their treating physicians were not masked to treatment allocation. The primary outcome of the trial was all-cause mortality in the intention-to-treat population at 1 year, we present here predefined outcomes at 5 years. The study is registered with ClinicalTrials.gov, number NCT00530894.Findings We screened 3105 patients, of whom 699 were enrolled (348 assigned to TAVR, 351 assigned to SAVR). Overall mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 11·7%. At 5 years, risk of death was 67·8% in the TAVR group compared with 62·4% in the SAVR group (hazard ratio 1·04, 95% CI 0·86-1·24; p=0·76). We recorded no structural valve deterioration requiring surgical valve replacement in either group. Moderate or severe aortic regurgitation occurred in 40 (14%) of 280 patients in the TAVR group and two (1%) of 228 in the SAVR group (p<0·0001), and was associated with increased 5-year risk of mortality in the TAVR group (72·4% for moderate or severe aortic regurgitation vs 56·6% for those with mild aortic regurgitation or less; p=0·003).Interpretation Our findings show that TAVR as an alternative to surgery for patients with high surgical risk results in similar clinical outcomes.Funding Edwards Lifesciences.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For patients at high or prohibitive risk of operative mortality, with surgical AVR, TAVR has been a transformative innovation, providing a life-saving treatment for patients who were previously not candidates for AVR”
From Calcific aortic stenosis (2016) · cites this paper as [223]
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationTwo-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Self-citationTranscatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Self-citationRegistry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Kapadia, S. R., Leon, M. B., Makkar, R. R., Tuzcu, E. M., Svensson, L. G., Kodali, S., Webb, J. G., Mack, M. J., Douglas, P. S., Thourani, V. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60290-2 · Cited by 867
Self-citationAthappan, G., Patvardhan, E., Tuzcu, E. M., Svensson, L. G., Lemos, P. A., Fraccaro, C., Tarantini, G., Sinning, J.-M., Nickenig, G., Capodanno, D., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.047 · Cited by 782
Self-citationVascular Complications After Transcatheter Aortic Valve Replacement
Généreux, P., Webb, J. G., Svensson, L. G., Kodali, S. K., Satler, L. F., Fearon, W. F., Davidson, C. J., Eisenhauer, A. C., Makkar, R. R., Bergman, G. W., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.003 · Cited by 518
Self-citationJilaihawi, H., Kashif, M., Fontana, G., Furugen, A., Shiota, T., Friede, G., Makhija, R., Doctor, N., Leon, M. B., & Makkar, R. R. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.045 · Cited by 480
Self-citation
Cited by
Items 601–700 of 1,000
Wang, D., Huang, L., Zhang, Y., Cheng, Z., Zhang, X., Ren, P., Hong, Q. E., & Kang, D. (2020) · Brazilian Journal of Cardiovascular Surgery · doi:10.21470/1678-9741-2019-0288 · Cited by 15
Kazemian, S., Fallahtafti, P., Sharifi, M. N., Mohammadi, N. S. H., Soleimani, H., Moghadam, A. S., Karimi, E., Sattar, Y., Jenab, Y., Mehrani, M., et al. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.124.036179 · Cited by 15
“1,2,31,32 Nevertheless, the PARTNER-1A study, reflecting an early experience with a first-generation device in high-risk patients, raised concerns because of the higher risk of stroke in the TAVR in comparison with SAVR at early follow-up in high-risk patients.”
Challenges When Expanding Transcatheter Aortic Valve Implantation to Younger Patients
Backer, O. D., & Søndergaard, L. (2018) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2018.00045 · Cited by 15
Tripathi, A., Flaherty, M. P., Abbott, J. D., Fonarow, G. C., Khan, A. R., Saraswat, A., Chahil, H., Kolte, D. S., Elmariah, S., Hirsch, G. A., et al. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.04.024 · Cited by 15
A Review of Alternative Access for Transcatheter Aortic Valve Replacement
Young, M. N., Singh, V., & Sakhuja, R. (2018) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-018-0648-5 · Cited by 15
Eltchaninoff, H., Durand, É., Barbanti, M., & Abdel‐Wahab, M. (2018) · EuroIntervention · doi:10.4244/eij-d-18-00653 · Cited by 15
Hein, M., Minners, J., Jander, N., Breitbart, P., Stratz, C., Pache, G., Neumann, F., & Ruile, P. (2019) · Clinical Research in Cardiology · doi:10.1007/s00392-019-01429-7 · Cited by 15
Subramani, S., Arora, L. L., Krishnan, S., Hanada, S., Sharma, A., & Ramakrishna, H. (2019) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2019.07.132 · Cited by 15
Predictors and outcomes of stroke after transcatheter aortic valve replacement
Hatfield, S. A., Nores, M. A., James, T., Rothenberg, M., Kapila, A., Cubeddu, R. J., & Stamou, S. C. (2019) · Journal of Cardiac Surgery · doi:10.1111/jocs.14300 · Cited by 15
“Transcatheter aortic valve replacement (TAVR) has been established as a safe and effective alternative to surgical aortic valve replacement in high and intermediate‐risk patients with aortic stenosis.(2) Due to technological advancements including newer valve generations, TAVR has evolved into a relatively safe proced…”
BackgroundDoyle, M., Woldendorp, K., Ng, M. K. C., Vallely, M. P., Wilson, M. K., Yan, T. D., & Bannon, P. G. (2021) · Journal of Thoracic Disease · doi:10.21037/jtd-20-2233 · Cited by 16
Heitzinger, G., Brunner, C., Koschatko, S., Dannenberg, V., Mascherbauer, K., Halavina, K., Donà, C., Koschutnik, M., Spinka, G., Nitsche, C., et al. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.791693 · Cited by 15
Kularatna, S., Byrnes, J., Mervin, M. C., & Scuffham, P. (2016) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462316000180 · Cited by 15
“The available HTAs from Belgium (10), Canada (12), and the United Kingdom (13) have based their reimbursement decisions on evidence provided by the Placement of Aortic Transcatheter Valve (PARTNER) trial data published in 2010 and 2011 (11;14;15).”
BackgroundČėsna, S., Backer, O. D., & Søndergaard, L. (2017) · Journal of Thoracic Disease · doi:10.21037/jtd.2017.05.67 · Cited by 15
“In addition, the first randomized trial comparing TAVR and SAVR in all-comer patients (NOTION) indicated that these findings also apply to patients at even lower surgical risk (8).”
BackgroundResultInfluentialShould TAVR Replace Surgery for Aortic Stenosis in Low- to Intermediate-Risk Patients?
Barker, C. M., & Reardon, M. J. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.06.013 · Cited by 17
van Kesteren, F., Wiegerinck, E. M. A., van Mourik, M. S., Vis, M. M., Koch, K. T., Piek, J. J., Stoker, J., Tijssen, J. G. P., Baan, J., & Planken, R. N. (2017) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2017.06.032 · Cited by 15
Transcatheter aortic valve implantation: a new standard of care
Nelson, A. J., Montarello, N. J., Cosgrove, C., Roberts-Thomson, R., Delacroix, S., Chokka, R. G., Montarello, J. K., & Worthley, S. G. (2018) · The Medical Journal of Australia · doi:10.5694/mja17.01255 · Cited by 15
Cheng, X., Hu, Q., Zhao, H., Qin, S., & Zhang, D. (2018) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2018.12.010 · Cited by 15
Transcatheter aortic valve replacement in low risk patients
Junquera, L., Ferreira‐Neto, A. N., Guimaraes, L. D. F. C., Asmarats, L., del Val, D., Wintzer-Wehekind, J., Muntané‐Carol, G., Freitas‐Ferraz, A. B., & Rodés‐Cabau, J. (2019) · Minerva Cardioangiologica · doi:10.23736/s0026-4725.18.04783-7 · Cited by 15
Kaier, K., Mühlen, C. V. Z., Zirlik, A., Bothe, W., Hehn, P., Zehender, M., Bode, C., & Stachon, P. (2019) · The European Journal of Health Economics · doi:10.1007/s10198-018-1023-x · Cited by 15
Buzzatti, N., Sala, A., & Alfieri, O. (2020) · European Heart Journal Supplements · doi:10.1093/eurheartj/suaa050 · Cited by 16
“Therefore in different centres, the axillary approach is today considered the second choice to be preferred when the femoral is not advisable and the transapical remains the third choice after the axillary approach.(13)”
BackgroundPushing the Limits in Transcatheter Aortic Valve Replacement
Nappi, F., Spadaccio, C., & Sablayrolles, J. L. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.08.014 · Cited by 15
“It seems that the procedural risk associated with TAVR is offset by a maturing experience of clinicians that has translated into the observed clinical benefit over the first 5 years (6).”
BackgroundRecent advances in understanding and managing aortic stenosis
Hemelrijck, M. V., Taramasso, M., Carlo, C. D., Kuwata, S., Regar, E. S., Nietlispach, F., Guadagnoli, A. F., Weber, A. C., & Maisano, F. (2018) · F1000Research · doi:10.12688/f1000research.11906.1 · Cited by 20
The Lotus Valve System: an In-depth Review of the Technology
Seigerman, M. E., Nathan, A. S., & Anwaruddin, S. (2019) · Current Cardiology Reports · doi:10.1007/s11886-019-1234-5 · Cited by 18
Ueyama, H. A., Kuno, T., Ando, T., Hayashida, K., & Takagi, H. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.02.088 · Cited by 15
Bavaria, J. E., Tommaso, C. L., Brindis, R. G., Carroll, J. D., Deeb, G. M., Feldman, T. E., Gleason, T. G., Horlick, E. M., Kavinsky, C. J., Kumbhani, D. J., et al. (2018) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2018.07.001 · Cited by 18
“Even though these sicker patients were excluded, the all-cause 5-year mortality rates of patients who received TAVR in the PARTNER 1B and PARTNER 1A trials were 72% (36) and 68% (37), respectively.”
BackgroundSelf-citationGozdek, M., Kuźma, Ł., Dąbrowski, E. J., Janiak, M., Pietrzak, M., Skonieczna, K., Woźnica, M., Wydeheft, L., Makhoul, M., Matteucci, M., et al. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20043439 · Cited by 14
Seiffert, M., Vonthein, R., Baumgartner, H., Borger, M. A., Choi, Y., Falk, V., Frey, N., Hagendorff, A., Hagl, C. M., Hamm, C. W., et al. (2023) · EuroIntervention · doi:10.4244/eij-d-23-00232 · Cited by 14
Mechanical Versus Bioprosthetic Aortic Valve Replacement in Patients Undergoing Bentall Procedure
Chen, C., Chen, C., Chang, F., Cheng, Y., Wu, V. C., Lin, C., Chan, Y., Hung, K., Chu, P., & Chen, S. (2023) · Journal of the American Heart Association · doi:10.1161/jaha.123.030328 · Cited by 14
Transcatheter Aortic Valve Implantation – Yesterday, Today and Tomorrow
Gooley, R., Cameron, J. D., & Meredith, I. T. (2015) · Heart Lung and Circulation · doi:10.1016/j.hlc.2015.07.017 · Cited by 20
“4% SAVR, and convergence of the rate of neurological events with no significant difference remaining between the groups [20].”
BackgroundYear in review: transcatheter aortic valve replacement
Tsai, M., Tang, G. H. L., & Cohen, G. N. (2016) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000260 · Cited by 14
Arora, S., Ramm, C. J., Strassle, P. D., Vaidya, S. R., Caranasos, T. G., & Vavalle, J. P. (2017) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2017.04.029 · Cited by 14
“These results showed stable hemodynamics for the Sapien valve at 5 years and were an extension to the 5-year results from the PARTNER trial published earlier, both for the inoperable and the high-risk cohort, which had shown stable AV mean gradients and absence of significant structural deterioration at 5-year follow-…”
ResultTheut, A. M., Thygesen, J. B., Backer, O. D., & Søndergaard, L. (2017) · EuroIntervention · doi:10.4244/eij-d-17-00147 · Cited by 14
Couteulx, S. L., Caudron, J., Dubourg, B., Cauchois, G., Dupré, M., Michelin, P., Durand, É., Eltchaninoff, H., & Dacher, J. (2018) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2017.12.007 · Cited by 14
Transcatheter aortic valve replacement in women
Itchhaporia, D. (2018) · Clinical Cardiology · doi:10.1002/clc.22912 · Cited by 14
Padang, R., Ali, M., Greason, K. L., Scott, C. G., Indrabhinduwat, M., Rihal, C. S., Eleid, M. F., Nkomo, V. T., Pellikka, P. A., & Pislaru, S. V. (2018) · BMJ Open · doi:10.1136/bmjopen-2018-022437 · Cited by 14
“≥Moderate RV dysfunction 19 (9) 35 (10) 0.”
Kumar, A., Sato, K., Jobanputra, Y. B., Betancor, J., Halane, M., George, R., Banerjee, K., Mohananey, D., Menon, V., Sammour, Y. M., et al. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.119.012430 · Cited by 14
“T ranscatheter aortic valve replacement (TAVR) is now a widely accepted alternative to surgical replacement among patients with symptomatic severe aortic stenosis in patients with intermediate-to-high surgical risk.(1,2) However, significant residual paravalvular regurgitation (PVR) after TAVR continues to be linked t…”
BackgroundSelf-citationOrvin, K., Zekry, S. B., Morelli, O., Barabash, I. M., Segev, A., Danenberg, H. D., Assali, A. R., Guetta, V., Assa, H. V., Zeniou, V., et al. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.08.043 · Cited by 14
A meta-analysis of ≥5-year mortality after transcatheter versus surgical aortic valve replacement
Takagi, H., on behalf of the All-Literature Investigation of Cardiovascular Evidence (ALICE) Group, Hari, Y., Nakashima, K., Kuno, T., & Ando, T. (2020) · The Journal of Cardiovascular Surgery · doi:10.23736/s0021-9509.19.11030-0 · Cited by 14
Bocchino, P. P., Angelini, F., Alushi, B., Conrotto, F., Cioffi, G. M., Tersalvi, G., Senatore, G., Pedrazzini, G. B., Ferrari, G. M. D., & Biasco, L. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.608158 · Cited by 14
Tuladhar, S. R., Mulderrig, S., Barbera, M. D., Vedovelli, L., Bottigliengo, D., Tessari, C., Jockenhoevel, S., Gregori, D., Thiene, G., Korossis, S., et al. (2021) · Materials Science and Engineering C · doi:10.1016/j.msec.2021.111936 · Cited by 14
Nozica, N., Siontis, G. C. M., Elchinova, E., Goulouti, E., Asami, M., Bartkowiak, J., Baldinger, S. H., Servatius, H., Seiler, J., Tanner, H., et al. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.876546 · Cited by 14
(2020) · Europe PMC (PubMed Central) · Cited by 15
Transfemoral aortic valve implantation: procedural hospital volume and mortality in Germany
Bestehorn, K. P., Bestehorn, M., Zahn, R., Perings, C., Stellbrink, C., & Schächinger, V. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac698 · Cited by 14
Vairo, A., Zaccaro, L., Ballatore, A., Airale, L., D’Ascenzo, F., Alunni, G., Conrotto, F., Scudeler, L., Mascaretti, D., Miccoli, D., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12031218 · Cited by 14
Khalique, O. K., Hamid, N. B., Kodali, S., Nazif, T. M., Marcoff, L., Paradis, J., Williams, M. R., Vahl, T. P., George, I., Leon, M. B., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.07.010 · Cited by 14
Self-citationTranscatheter Aortic Valve Replacement: State of the Art and Future Directions
Eleid, M. F., & Holmes, D. R. (2016) · Annual Review of Medicine · doi:10.1146/annurev-med-101615-020427 · Cited by 16
“92) with no reported incidence of structural valve deterioration in either group (54).”
BackgroundKülling, M., Külling, J., Wyss, C. A., Hürlimann, D., Reho, I., Salzberg, S. P., Bühler, I., Noll, G., Grünenfelder, J., Corti, R., et al. (2016) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jew301 · Cited by 14
“The importance of correct calculation of EOA is demonstrated in the recently published 5-year results of the PARTNER 1 trial.(11) The EOA in PARTNER 1 with a population of mixed 23 and 26mm Sapien prostheses was continuously calculated at around 1.”
BackgroundResultTranscatheter Mitral Valve Interventions: Current Therapies and Future Directions
Partida, R. A., & Elmariah, S. (2017) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-017-0538-2 · Cited by 14
Calle-Valda, C. M., Aguilar, R., Benedicto, A., Sarraj, A., Monguió, E., Muñoz, D. E., de Antonio, N., & Reyes, G. (2017) · Heart Lung and Circulation · doi:10.1016/j.hlc.2017.08.010 · Cited by 14
Tabata, N., Al‐Kassou, B., Sugiura, A., Shamekhi, J., Sedaghat, A., Treede, H., Tsujita, K., Werner, N., Grube, E., Nickenig, G., et al. (2020) · Clinical Research in Cardiology · doi:10.1007/s00392-020-01609-w · Cited by 15
Kronfli, A. P., Lehman, E. B., Yamane, K., Roberts, M., & Cios, T. J. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.08.039 · Cited by 14
Humbert, M., Büla, C., Müller, O., Krief, H., & Monney, P. A. (2021) · BMC Geriatrics · doi:10.1186/s12877-021-02100-5 · Cited by 18
Elective versus urgent in‐hospital transcatheter aortic valve implantation
Kabahizi, A., Sheikh, A. S., Williams, T. M., Tanseco, K., Myat, A., Trivedi, U., de Belder, A., Cockburn, J., & Hildick‐Smith, D. (2021) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.29638 · Cited by 14
Comparison of Self-Expanding RDV Perceval S versus TAVI ACURATE neo/TF
Mauri, V., Gerfer, S., Kuhn, E. W., Adam, M., Eghbalzadeh, K., Djordjevic, I., Ivanov, B., Gaisendrees, C., Frerker, C., Schmidt, T., et al. (2021) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-0040-1722692 · Cited by 15
Transcatheter Aortic Valve Replacement for Bicuspid Aortic Stenosis
Makkar, R., Chakravarty, T., & Jilaihawi, H. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.06.042 · Cited by 14
Self-citationEarly transcatheter valve prosthesis degeneration and future ramifications
Arora, S., Ramm, C. J., Misenheimer, J. A., & Vavalle, J. P. (2017) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2016.08.04 · Cited by 14
Kachel, M., Buszman, P. P., Milewski, K. P., Michalak, M., Domaradzki, W., Pruski, M., Sobota, M., Fernández, C., Konopko, M., Nożyński, J. K., et al. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.977006 · Cited by 13
Abdelghani, M., & Serruys, P. W. J. C. (2016) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.115.002944 · Cited by 15
Ielasi, A., Latib, A., Tespili, M., & Donatelli, F. (2019) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2019.100375 · Cited by 13
Wang, A., Li, Z., Rymer, J. A., Kosinski, A. S., Yerokun, B. A., Cox, M. L., Gulack, B. C., Sherwood, M. W., Lópes, R. D., Inohara, T., et al. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.06.005 · Cited by 13
Self-citationMurray, M.-I. K., Hofmann, E., Rosa, R. D., Mas‐Peiró, S., Seppelt, P. C., Walther, T., Zeiher, A. M., Fichtlscherer, S., & Vasa‐Nicotera, M. (2019) · Journal of Interventional Cardiology · doi:10.1155/2019/4292987 · Cited by 16
“Transcatheter aortic valve implantation (TAVI) is the standard treatment for patients with severe aortic stenosis at high and excessive risk for surgery [1, 4, 5].”
Multivariate meta-analysis model for the difference in restricted mean survival times
Weir, I. R., Tian, L., & Trinquart, L. (2019) · Biostatistics · doi:10.1093/biostatistics/kxz018 · Cited by 14
Long-Term Outcome and Quality of Life After Biological Aortic Valve Replacement in Nonelderly Adults
Petersen, J., Krogmann, H., Reichenspurner, H. C., & Girdauskas, E. (2020) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2020.04.097 · Cited by 13
Pinar, E., de Lara, J. G., Hurtado, J., Robles, M., Leithold, G., Martí-Sánchez, B., Cuervo, J., Pascual-Figal, D. A., Estévez-Carrillo, A., & Crespo, C. (2021) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2021.02.013 · Cited by 13
Krasniqi, L., Brandes, A., Mortensen, P. E., Gerke, O., & Riber, L. P. (2024) · Interdisciplinary CardioVascular and Thoracic Surgery · doi:10.1093/icvts/ivae122 · Cited by 13
Musa, T. A., Plein, S., & Greenwood, J. P. (2016) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2016.06.05 · Cited by 14
Bouleti, C., Chauvet-Droit, M., Franchineau, G., Himbert, D., Iung, B., Alos, B., Brochet, É., Ureña, M., Ghodbane, W., Ou, P., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw211 · Cited by 13
“Moreover, several randomized studies have compared TAVI with surgical AVR with a non-inferiority [9, 13] or even a superiority of TAVI over surgical AVR in selected patients [7].”
BackgroundResultD’Onofrio, A., Besola, L., Rizzoli, G., Bizzotto, E., Manzan, E., Tessari, C., Bianco, R., Tarantini, G., Badano, L. P., Napodano, M., et al. (2016) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2016.06.042 · Cited by 13
Kobayashi, Y., Kim, J. B., Moneghetti, K. J., Kobayashi, Y., Zhang, R., Brenner, D. A., O’Malley, R., Schnittger, I., Fischbein, M. P., Miller, D. C., et al. (2017) · International journal of cardiac imaging · doi:10.1007/s10554-017-1155-6 · Cited by 14
Self-citationKuo, K., Shah, P. J., Hiebert, B. M., Love, K., Menkis, A. H., Manji, R. A., & Arora, R. C. (2017) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2017.05.047 · Cited by 13
García, E. B., Cámara, M. L., Estévez, F., Dominguez, E. S., Barrera, R. R., Sbraga, F., Puente, J. G., Roselló-Díez, E., Caballero, G. P. C., Munguira, J. B., et al. (2017) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivx384 · Cited by 13
“AVS is associated with ageing, and when it is severe and symptomatic, its progression without treatment is usually the worst prognosis [2, 3].”
BackgroundConvelbo, C., El‐Hafci, H., Petite, H., & Zegdi, R. (2017) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezx451 · Cited by 13
Hu, X., Yang, F., Wang, Y., Zhang, Y., & Chen, M. (2018) · Cardiology · doi:10.1159/000490307 · Cited by 13
Prasitlumkum, N., Thangjui, S., Leesutipornchai, T., Kewcharoen, J., Limpruttidham, N., & Pai, R. G. (2020) · Cardiovascular Intervention and Therapeutics · doi:10.1007/s12928-020-00675-1 · Cited by 13
In‐hospital stroke after transcatheter aortic valve implantation: A UK observational cohort analysis
Myat, A., Buckner, L., Mouy, F., Cockburn, J., Baumbach, A., BANNING, A. P., Blackman, D. J., Curzen, N. P., MacCarthy, P. A., Mullen, M., et al. (2020) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.29157 · Cited by 13
(2016) · PubMed · Cited by 18
Hermans, M. C., van Mourik, M. S., Hermens, H. J., Baan, J., & Vis, M. M. (2018) · JMIR Cardio · doi:10.2196/cardio.9075 · Cited by 14
Novel Robotic Approach for Minimally Invasive Aortic Heart Valve Surgery
Tamadon, I., Soldani, G., Dario, P., & Menciassi, A. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513309 · Cited by 13
Advances in transcatheter aortic valve replacement.
Ando, T., Briasoulis, Α., & Panaich, S. (2019) · PubMed Central · doi:10.11909/j.issn.1671-5411.2019.09.002 · Cited by 13
Transcatheter and surgical aortic valve replacement impact on outcomes and cancer treatment schedule
Gill, C., Lee, M., Balanescu, D. V., Donisan, T., Canache, A. S., Palaskas, N. L., Lopez‐Mattei, J., Kim, P. Y., Song, J., Yang, E. H., et al. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.08.071 · Cited by 13
Taghizadeh‐Waghefi, A., Arzt, S., Wenzel, L., Petrov, A., Wilbring, M., Matschke, K. E., Kappert, U., & Alexiou, K. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13040985 · Cited by 12
“Across all surgical risk categories, TAVI has demonstrated non-inferior mortality outcomes compared to SAVR in the short to medium term [1–5].”
BackgroundSherbini, A. E., Servito, M., Zidan, A., Elsherif, S., Ko, G., Elgendy, I. Y., & Ya’qoub, L. (2024) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.30985 · Cited by 12
“16 19 In addition, vascular problems, bleeding, and short ‐ term mortality rates after TAVR have been reported to be higher in women than in males.”
BackgroundSilva, I., Alperi, A., Muñoz, A. J. J., Cheema, A. N., y, L. N.-F., Fernández, G. V., Tay, E. L. W., Ureña, M., Asmarats, L., Trigo, M. D., et al. (2025) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeaf083 · Cited by 12
Doenst, T., Gregg, A. C., Kirov, H., Franco, A. D., Caldonazo, T. M. M., Rahouma, M., Krieger, K., Pisano, F., Gaudino, M. F. L., & Falk, V. (2025) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezaf215 · Cited by 12
Transcatheter Aortic Valve Replacement: 2015 in Review
Harjai, K. J., Grines, C. L., & Leon, M. B. (2016) · Journal of Interventional Cardiology · doi:10.1111/joic.12274 · Cited by 12
Self-citationTakagi, H., Mitta, S., Ando, T., & for the ALICE (All‐Literature Investigation of Cardiovascular Evidence) group (2018) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27521 · Cited by 12
“1 | INTRODUCTION To the best of our knowledge, five randomized controlled trials (RCTs) (Placement of Aortic Transcatheter Valves [PARTNER] 1 [1], PARTNER 2 [2], CoreValve US Pivotal [3], Nordic Aortic Valve Intervention [NOTION] [4], and Surgical Replacement and Transcatheter Aortic Valve Implantation [SURTAVI] [5])…”
BackgroundResultInfluentialMukdad, L. A., Kashani, R. G., Mantha, A., Sareh, S., Mendelsohn, A. H., & Benharash, P. (2018) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2018.05.040 · Cited by 12
Apostolidou, E., Aronow, H. D., Beale, C. E., Kolte, D. S., Kennedy, K. F., Sellke, F. W., Gordon, P. C., Sharaf, B. L., & Ehsan, A. (2018) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2018.11.022 · Cited by 12
Biomarkers of aortic bioprosthetic valve structural degeneration
Salaün, E., Côté, N., Clavel, M.-A. A., & Pîbarot, P. (2018) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000590 · Cited by 12
Witberg, G., Shamekhi, J., Mieghem, N. M. V., Guadagnoli, A. F., Soendergaard, L., Dvir, D., Latib, A., Testa, L., Guerrero, M. E., Piazza, N., et al. (2019) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2019.01.003 · Cited by 12
Self-citationLi, X., Hagar, A., Wei, X., Chen, F., Li, Y., Xiong, T., Ou, Y., Zhao, Z., Li, Q., Peng, Y., et al. (2021) · Radiology · doi:10.1148/radiol.2021210267 · Cited by 12
The ACURATE neo ™ and neo2 ™ Valve Systems
Reardon, M. J. (2021) · Heart International · doi:10.17925/hi.2021.15.1.37 · Cited by 12
Ishizu, K., Murakami, N., Morinaga, T., Hayashi, M., Isotani, A., Arai, Y., Ohno, N., Kakumoto, S., Shirai, S., & Andò, K. (2022) · Heart and Vessels · doi:10.1007/s00380-021-01999-5 · Cited by 12
Three‐year survival of transcatheter versus surgical aortic valve replacement in dialysis
Ogami, T., Kurlansky, P. A., Takayama, H., Ning, Y., Zimmermann, E. M., Zhu, R. C., Ali, Z. A., Nazif, T. M., Vahl, T. P., Avgerinos, D. V., et al. (2022) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.30045 · Cited by 12
Self-citationAbdelshafy, M., Serruys, P. W. J. C., Kim, W., Rück, A., Wang, R., Tao, L., Elkoumy, A., Elzomor, H., Garg, S., Onuma, Y., et al. (2022) · Journal of the Society for Cardiovascular Angiography & Interventions · doi:10.1016/j.jscai.2022.100037 · Cited by 13
Ahmad, Y., Makkar, R., & Søndergaard, L. (2022) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2022.05.007 · Cited by 12
Self-citationMonitored Anesthesia Care Versus General Anesthesia for Transcatheter Aortic Valve Replacement
Holmes, H. R., Falasa, M. P., Neal, D. W., Choi, C., Park, K. E., Bavry, A. A., Freeman, K. A., Manning, E. W., Stinson, W. W., & Jeng, E. I.-H. (2022) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1177/15569845221124113 · Cited by 13
Transcatheter Aortic Valve Implantation: Current Trends and Future Directions
Allahwala, U. K., HANSEN, P. S., Danson, E., Straiton, N., Sinhal, A. R., Walters, D., & Bhindi, R. (2015) · Future Cardiology · doi:10.2217/fca.15.73 · Cited by 12
Transcatheter Aortic Valve Implantation
Malaisrie, S. C., Iddriss, A., Flaherty, J. D., & Churyla, A. (2016) · Current Atherosclerosis Reports · doi:10.1007/s11883-016-0577-2 · Cited by 12
Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis Using Lotus Valve System
Chan, A. W., Wong, D. R., & Charania, J. (2016) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26506 · Cited by 12
Metadata
- Authors
- Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., Kodali, S. K., Makkar, R. R., Fontana, G. P., Kapadia, S., Bavaria, J., Hahn, R. T., Thourani, V. H., Babaliaros, V., Pichard, A., Herrmann, H. C., Brown, D. L., Williams, M., Davidson, M. J., Svensson, L. G., & Akin, J.
- Affiliations
- Baylor Scott & White Health (US)
- NewYork–Presbyterian Hospital (US)
- Stanford Medicine (US)
- Cleveland Clinic (US)
- St. Paul's Hospital (CA)
- Duke Medical Center (US)
- Cedars-Sinai Medical Center (US)
- Lenox Hill Hospital (US)
- University of Pennsylvania (US)
- Emory University (US)
- MedStar Washington Hospital Center (US)
- Heart Hospital Baylor Plano (US)
- NYU Langone Health (US)
- Brigham and Women's Hospital (US)
- Corresponding author
- Mack, Michael J
- ORCID
- Mack, Michael J
- Leon, Martin B
- Smith, Craig R
- Miller, D Craig
- Moses, Jeffrey W
- Tuzcu, E Murat
- Webb, John G
- Douglas, Pamela S
- Anderson, William N
- Blackstone, Eugene H
- Kodali, Susheel K
- Makkar, Raj R
- Fontana, Gregory P
- Kapadia, Samir
- Bavaria, Joseph
- Hahn, Rebecca T
- Thourani, Vinod H
- Babaliaros, Vasilis
- Herrmann, Howard C
- Brown, David L
- Williams, Mathew
- Svensson, Lars G
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 385
- Issue
- 9986
- Pages
- 2477-2484
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2067905792
- Cited by
- 1,739
- References
- 31
- Citations by year
- 2026: 55 · 2025: 122 · 2024: 140 · 2023: 110 · 2022: 120 · 2021: 158 · 2020: 189 · 2019: 186 · 2018: 188 · 2017: 208 · 2016: 188 · 2015: 64
- FWCI
- 157.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Boston Scientific Corporation
- Medtronic
- Abbott Vascular
- St. Jude Medical
- National Heart, Lung, and Blood Institute (67025)
- Edwards Lifesciences
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- transcatheter aortic valve implantation, surgical aortic valve replacement, aortic stenosis, high-risk surgical patients, five-year outcomes, all-cause mortality, aortic regurgitation, transapical approach, transfemoral access, PARTNER trial, structural valve deterioration
- MeSH terms
- Aged, Aged, 80 and over, Aortic Valve, Aortic Valve Insufficiency, Aortic Valve Stenosis, Canada, Cause of Death, Female, Follow-Up Studies, Germany, Humans, Male, United States, Comorbidity, Survival Rate, Survival Analysis, Treatment Outcome, Heart Valve Prosthesis Implantation, Transcatheter Aortic Valve Replacement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.