A universal artificial intelligence platform for collaborative management of cataracts
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background Common diseases are not satisfactorily managed under the current health-care system because of inadequate medical resources and limited accessibility. We aimed to establish and validate a universal artificial intelligence (AI) platform for collaborative management of cataracts involving multilevel clinical scenarios, and explored an AI-based medical referral pattern to improve collaborative efficiency and resource coverage. Methods The training and validation datasets were derived from the Chinese Medical Alliance for Artificial Intelligence, covering multilevel health-care facilities and capture modes. The datasets were labeled using a three-step strategy: capture mode recognition (modes: mydriatic-diffuse, mydriatic-slit lamp, non-mydriatic-diffuse, and nonmydriatic-slit lamp); cataract diagnosis as a normal lens, cataract, or a postoperative eye; and detection of referable cataracts with respect to cause and severity. Area under curve [AUC] was measured at each stage. We also integrated the above cataract AI agent with a real-world multilevel referral pattern involving self-monitoring at home, primary health care, and specialised hospital services. The diagnostic accuracy, treatment referral, and ophthalmologist-to-population service ratio were used to evaluate the performance and efficacy of the system. Findings The universal AI platform and multilevel collaborative pattern showed robust diagnostic performance in three-step tasks: capture mode recognition (AUC 99·28–99·71% for the four different capture modes), cataract diagnosis (AUC for mydriatic-slit lamp mode 99·82% [95%CI 98·93–100] for normal lens vs 99·96% [99·90–100] for cataract vs 99·93% [99·78–100] for postoperative eye, and AUCs >99% for other capture modes), and detection of referable cataracts (AUCs >91% in all tests). In the real-world tertiary referral pattern, the agent suggested 30·3% of people be referred to treatment, substantially increasing the ophthalmologist-to-population service ratio by 10·2-times compared with the traditional pattern. Interpretation The universal AI platform and multilevel collaborative pattern showed robust diagnostic performance and effective service for cataracts. The context of our AI-based medical referral pattern will be extended to other common disease conditions and resource-intensive situations. Funding National Key Research and Development Program, National Natural Science Foundation of China, Science Foundation of China for Excellent Young Scientists, Guangdong Provincial Natural Science Foundation, Guangdong Province Universities and Colleges Youth Pearl River Scholar Funding Scheme, Science and Technology Planning Projects of Guangdong Province, Clinical Research and Translational Medical Center of Pediatric Cataract in Guangzhou City, Outstanding Young Teacher Cultivation Projects in Guangdong Province, Fundamental Research Funds for the Central Universities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Self-citationBatch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S., & Szegedy, C. (2015) · arXiv · doi:10.48550/arxiv.1502.03167 · Cited by 27,818
Dermatologist-level classification of skin cancer with deep neural networks
Esteva, A., Kuprel, B., Novoa, R. A., Ko, J., Swetter, S. M., Blau, H. M., & Thrun, S. (2017) · Nature · doi:10.1038/nature21056 · Cited by 14,362
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Self-citationArtificial intelligence in healthcare: past, present and future
Jiang, F., Jiang, Y., Zhi, H., Dong, Y., Li, H., Ma, S., Wang, Y., Dong, Q., Shen, H., & Wang, Y. (2017) · Stroke and Vascular Neurology · doi:10.1136/svn-2017-000101 · Cited by 4,837
Clinically applicable deep learning for diagnosis and referral in retinal disease
De Fauw, J., Ledsam, J. R., Romera-Paredes, B., Nikolov, S., Tomasev, N., Blackwell, S., Askham, H., Glorot, X., O’Donoghue, B., Visentin, D., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0107-6 · Cited by 2,639
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Automated Identification of Diabetic Retinopathy Using Deep Learning
Gargeya, R., & Leng, T. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.02.008 · Cited by 1,362
Lens Opacities Classification System II (LOCS II)
Chylack, L. T. (1989) · Archives of Ophthalmology · doi:10.1001/archopht.1989.01070020053028 · Cited by 567
Long, E., Lin, H., Liu, Z., Wu, X., Wang, L., Jiang, J., An, Y., Lin, Z., Li, X., Chen, J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0024 · Cited by 358
Self-citationvan der Heijden, A. A., Abramoff, M. D., Verbraak, F., van Hecke, M. V., Liem, A., & Nijpels, G. (2018) · Acta Ophthalmologica · doi:10.1111/aos.13613 · Cited by 296
Li, Z., Keel, S., Liu, C., He, Y., Meng, W., Scheetz, J., Lee, P. Y., Shaw, J., Ting, D., Wong, T. Y., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0147 · Cited by 255
Self-citationAutomatic Feature Learning to Grade Nuclear Cataracts Based on Deep Learning
Gao, X., Lin, S., & Wong, T. Y. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2444389 · Cited by 255
The Current State of Teleophthalmology in the United States
Rathi, S., Tsui, E., Mehta, N., Zahid, S., & Schuman, J. S. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.05.026 · Cited by 248
Wu, X., Long, E., Lin, H., & Liu, Y. (2016) · Scientific Reports · doi:10.1038/srep28564 · Cited by 235
Self-citationLin, H., Li, R., Liu, Z., Chen, J., Yang, Y., Chen, H., Lin, Z., Lai, W., Long, E., Wu, X., et al. (2019) · EClinicalMedicine · doi:10.1016/j.eclinm.2019.03.001 · Cited by 199
Self-citationPredicting the early risk of chronic kidney disease in patients with diabetes using real-world data
Ravizza, S., Huschto, T., Adamov, A., Böhm, L., Büsser, A., Flöther, F. F., Hinzmann, R., König, H., McAhren, S. M., Robertson, D. H., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0239-8 · Cited by 167
Song, P., Wang, H., Theodoratou, E., Chan, K. Y., & Rudan, I. (2018) · Journal of Global Health · doi:10.7189/jogh.08.010804 · Cited by 164
Teleophthalmology: improving patient outcomes?
Sreelatha, O., & S Ve, R. (2016) · Clinical Ophthalmology · doi:10.2147/opth.s80487 · Cited by 135
A Computer-Aided Diagnosis System of Nuclear Cataract
Li, H., Lim, J., Liu, J., Mitchell, P. L. R., Tan, A. G., Wang, J. J., & Wong, T. Y. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2041454 · Cited by 114
Tang, Y., Wang, X., Wang, J., Huang, W. C., Gao, Y., Luo, Y., Yang, J., & Lü, Y. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-18380 · Cited by 72
Ramke, J., Zwi, A. B., Lee, A. C.-L., Blignault, I., & Gilbert, C. E. (2017) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2016-309691 · Cited by 30
Wong, W. L., Li, X., Li, J., Cheng, C., Lamoureux, E. L., Wang, J. J., Cheung, C. Y.-L., & Wong, T. Y. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10657 · Cited by 28
Global Teleophthalmology With iPhones for Real-Time Slitlamp Eye Examination
Ye, Y., Wang, J., Xie, Y., Zhong, J., Hu, Y., Chen, B., He, X., & Zhang, H. (2014) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000051 · Cited by 25
Limwattananon, C., Limwattananon, S., Tungthong, J., & Sirikomon, K. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.1843 · Cited by 13
Cited by
The Lancet Global Health Commission on Global Eye Health: vision beyond 2020
Burton, M. J., Ramke, J., Marques, A. P., Bourne, R. R. A., Congdon, N., Jones, I., Ah Tong, B. A. M., Arunga, S., Bachani, D., Bascaran, C., et al. (2021) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30488-5 · Cited by 1,624
Digital technology, tele-medicine and artificial intelligence in ophthalmology: A global perspective
Li, J.-P. O., Liu, H., Ting, D. S. J., Jeon, S., Chan, R. V. P., Kim, J. E., Sim, D. A., Thomas, P. B. M., Lin, H., Chen, Y., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100900 · Cited by 626
Self-citationRole of Artificial Intelligence Applications in Real-Life Clinical Practice: Systematic Review
Yin, J., Ngiam, K. Y., & Teo, H. H. (2021) · Journal of Medical Internet Research · doi:10.2196/25759 · Cited by 419
Cicinelli, M. V., Buchan, J. C., Nicholson, M., Varadaraj, V., & Khanna, R. C. (2023) · The Lancet · doi:10.1016/s0140-6736(22)01839-6 · Cited by 332
Metaverse and Virtual Health Care in Ophthalmology: Opportunities and Challenges
Tan, T. F., Li, Y., Lim, J. S., Gunasekeran, D. V., Teo, Z. L., Ng, W. Y., & Ting, D. S. (2022) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000537 · Cited by 208
Metadata
- Authors
- Wu, X., Huang, Y., Liu, Z., Lai, W., Long, E., Zhang, K., Jiang, J., Lin, D., Chen, K., Yu, T., Wu, D., Li, C., Chen, Y., Zou, M., Chen, C., Zhu, Y., Guo, C., Zhang, X., Wang, R., Yang, Y., Xiang, Y., Chen, L., Liu, C., Xiong, J., Ge, Z., Wang, D., Xu, G., Du, S., Xiao, C., Wu, J., Zhu, K., Nie, D., Xu, F., Lv, J., Chen, W., Liu, Y., & Lin, H.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 394
- Issue
- 11
- Pages
- S22
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2966869985
- Cited by
- 159
- References
- 25
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.