Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 255

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Automatic Feature Learning to Grade Nuclear Cataracts Based on Deep Learning

Gao, Xinting, Lin, Stephen, Wong, Tien Yin·2015·IEEE Transactions on Biomedical Engineering

Abstract

GOAL: Cataracts are a clouding of the lens and the leading cause of blindness worldwide. Assessing the presence and severity of cataracts is essential for diagnosis and progression monitoring, as well as to facilitate clinical research and management of the disease. METHODS: Existing automatic methods for cataract grading utilize a predefined set of image features that may provide an incomplete, redundant, or even noisy representation. In this study, we propose a system to automatically learn features for grading the severity of nuclear cataracts from slit-lamp images. Local filters are first acquired through clustering of image patches from lenses within the same grading class. The learned filters are fed into a convolutional neural network, followed by a set of recursive neural networks, to further extract higher order features. With these features, support vector regression is applied to determine the cataract grade. RESULTS: The proposed system is validated on a large population-based dataset of [Formula: see text] images, where it outperforms the state of the art by yielding with respect to clinical grading a mean absolute error ( ε) of 0.304, a 70.7% exact integral agreement ratio ( R0), an 88.4% decimal grading error ≤ 0.5 ( Re0.5 ), and a 99.0% decimal grading error ≤ 1.0 ( Re1.0 ). SIGNIFICANCE: The proposed method is useful for assisting and improving clinical management of the disease in the context of large-population screening and has the potential to be applied to other eye diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2015.2444389

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 255

Metadata

Authors
Gao, X., Lin, S., & Wong, T. Y.
Venue
IEEE Transactions on Biomedical Engineering
Published
2015-11
Volume
62
Issue
11
Pages
2693-2701
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W1897657709
Cited by
255
References
23
FWCI
7.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic Feature Learning to Grade Nuclear Cataracts Based on Deep Learning. https://app.cochat.ai/papers/10.1109/tbme.2015.2444389
The paper
Gao, X., Lin, S., & Wong, T. Y. (2015). Automatic Feature Learning to Grade Nuclear Cataracts Based on Deep Learning. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2015.2444389

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.