Oxygenated versus standard cold perfusion preservation in kidney transplantation (COMPARE): a randomised, double-blind, paired, phase 3 trial

Open access
Jochmans, Ina, Brat, Aukje, Davies, Lucy, Hofker, H Sijbrand, van de Leemkolk, Fenna E M, Leuvenink, Henri G D, Knight, Simon R, Pirenne, Jacques, Ploeg, Rutger J, Abramowicz, Daniel, Banga, Neal, Bemelman, Frederike J, Betjes, Michiel GH, Burns, Richéal, Chiocchia, Virginia, Christiaans, Maarten HL, Darius, Tom, de Jonge, Jeroen, de Vries, Aiko PJ, Detry, Olivier, Hilbrands, Luuk B, Hofker, H Sijbrand, Hoksbergen, Arjan WJ, Huurman, Volkert AL, Idu, Mirza M, Jacobs-Tulleneers-Thevissen, Daniel, Jochmans, Ina, Kaisar, Maria, Kanaan, Nada, Kimenai, Diederik, Kuypers, Dirk, Le Moine, Alain, Marshall, Carl, Meurisse, Nicolas, Mikhalski, Dimitri, Moers, Cyril, Monbaliu, Diethard, Nijboer, Willemijn N, Nurmohamed, S Azam, O'Callaghan, John, Papalois, Vassilios, Pipeleers, Lissa, Poyck, Paul PC, Quiroga, Isabel, Randon, Caren, Schurink, Geert W, Seelen, Marc, Szabo, Laszlo, Toorop, Raechel J, van de Poll, Marcel CG, van der Jagt, Michel FP, Van Laecke, Steven, van Zuilen, Arjan D, Weekers, Laurent, Ysebaert, Dirk · 2020 · The Lancet
Cited by 203

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

BACKGROUND Deceased donor kidneys are preserved in cold hypoxic conditions. Providing oxygen during preservation might improve post-transplant outcomes, particularly for kidneys subjected to greater degrees of preservation injury. This study aimed to investigate whether supplemental oxygen during hypothermic machine perfusion (HMP) could improve the outcome of kidneys donated after circulatory death. METHODS This randomised, double-blind, paired, phase 3 trial was done in 19 European transplant centres. Kidney pairs from donors aged 50 years or older, donated after circulatory death, were eligible if both kidneys were transplanted into two different recipients. One kidney from each donor was randomly assigned using permuted blocks to oxygenated hypothermic machine perfusion (HMPO2), the other to HMP without oxygenation. Perfusion was maintained from organ retrieval to implantation. The primary outcome was 12-month estimated glomerular filtration rate (eGFR) using the Chronic Kidney Disease Epidemiology Collaboration equation in pairs of donated kidneys in which both transplanted kidneys were functioning at the end of follow-up. Safety outcomes were reported for all transplanted kidneys. Intention-to-treat analyses were done. This trial is registered with the ISRCTN Registry, ISRCTN32967929, and is now closed. FINDINGS Between March 15, 2015, and April 11, 2017, 197 kidney pairs were randomised with 106 pairs transplanted into eligible recipients. 23 kidney pairs were excluded from the primary analysis because of kidney failure or patient death. Mean eGFR at 12 months was 50·5 mL/min per 1·73 m2 (SD 19·3) in the HMPO2 group versus 46·7 mL/min per 1·73m2 (17·1) in HMP (mean difference 3·7 mL/min per 1·73m2, 95% CI -1·0 to 8·4; p=0·12). Fewer severe complications (Clavien-Dindo grade IIIb or more) were reported in the HMPO2 group (46 of 417, 11%, 95% CI 8% to 14%) than in the HMP group (76 of 474, 16%, 13% to 20%; p=0·032). Graft failure was lower with HMPO2 (three [3%] of 106) compared with HMP (11 [10%] of 106; hazard ratio 0·27, 95% CI 0·07 to 0·95; p=0·028). INTERPRETATION HMPO2 of kidneys donated after circulatory death is safe and reduces post-transplant complications (grade IIIb or more). The 12-month difference in eGFR between the HMPO2 and HMP groups was not significant when both kidneys from the same donor were still functioning 1-year post-transplant, but potential beneficial effects of HMPO2 were suggested by analysis of secondary outcomes. FUNDING European Commission 7th Framework Programme.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0140-6736(20)32411-9

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 203

Metadata

Authors
Jochmans, I., Brat, A., Davies, L., Hofker, H. S., van de Leemkolk, F. E. M., Leuvenink, H. G. D., Knight, S. R., Pirenne, J., Ploeg, R. J., Abramowicz, D., Banga, N., Bemelman, F. J., Betjes, M. G., Burns, R., Chiocchia, V., Christiaans, M. H., Darius, T., de Jonge, J., de Vries, A. P., Detry, O., Hilbrands, L. B., Hofker, H. S., Hoksbergen, A. W., Huurman, V. A., Idu, M. M., Jacobs-Tulleneers-Thevissen, D., Jochmans, I., Kaisar, M., Kanaan, N., Kimenai, D., Kuypers, D., Le Moine, A., Marshall, C., Meurisse, N., Mikhalski, D., Moers, C., Monbaliu, D., Nijboer, W. N., Nurmohamed, S. A., O'Callaghan, J., Papalois, V., Pipeleers, L., Poyck, P. P., Quiroga, I., Randon, C., Schurink, G. W., Seelen, M., Szabo, L., Toorop, R. J., van de Poll, M. C., van der Jagt, M. F., Van Laecke, S., van Zuilen, A. D., Weekers, L., & Ysebaert, D.
Venue
The Lancet
Publisher
Elsevier BV
Published
2020-11
Volume
396
Issue
10263
Pages
1653-1662
ISSN
  • 0099-5355 (ISSN-L)
  • 0140-6736
OpenAlex
W3090248241
Cited by
203
References
20
FWCI
24.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.