Oxygenated versus standard cold perfusion preservation in kidney transplantation (COMPARE): a randomised, double-blind, paired, phase 3 trial
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
BACKGROUND Deceased donor kidneys are preserved in cold hypoxic conditions. Providing oxygen during preservation might improve post-transplant outcomes, particularly for kidneys subjected to greater degrees of preservation injury. This study aimed to investigate whether supplemental oxygen during hypothermic machine perfusion (HMP) could improve the outcome of kidneys donated after circulatory death. METHODS This randomised, double-blind, paired, phase 3 trial was done in 19 European transplant centres. Kidney pairs from donors aged 50 years or older, donated after circulatory death, were eligible if both kidneys were transplanted into two different recipients. One kidney from each donor was randomly assigned using permuted blocks to oxygenated hypothermic machine perfusion (HMPO2), the other to HMP without oxygenation. Perfusion was maintained from organ retrieval to implantation. The primary outcome was 12-month estimated glomerular filtration rate (eGFR) using the Chronic Kidney Disease Epidemiology Collaboration equation in pairs of donated kidneys in which both transplanted kidneys were functioning at the end of follow-up. Safety outcomes were reported for all transplanted kidneys. Intention-to-treat analyses were done. This trial is registered with the ISRCTN Registry, ISRCTN32967929, and is now closed. FINDINGS Between March 15, 2015, and April 11, 2017, 197 kidney pairs were randomised with 106 pairs transplanted into eligible recipients. 23 kidney pairs were excluded from the primary analysis because of kidney failure or patient death. Mean eGFR at 12 months was 50·5 mL/min per 1·73 m2 (SD 19·3) in the HMPO2 group versus 46·7 mL/min per 1·73m2 (17·1) in HMP (mean difference 3·7 mL/min per 1·73m2, 95% CI -1·0 to 8·4; p=0·12). Fewer severe complications (Clavien-Dindo grade IIIb or more) were reported in the HMPO2 group (46 of 417, 11%, 95% CI 8% to 14%) than in the HMP group (76 of 474, 16%, 13% to 20%; p=0·032). Graft failure was lower with HMPO2 (three [3%] of 106) compared with HMP (11 [10%] of 106; hazard ratio 0·27, 95% CI 0·07 to 0·95; p=0·028). INTERPRETATION HMPO2 of kidneys donated after circulatory death is safe and reduces post-transplant complications (grade IIIb or more). The 12-month difference in eGFR between the HMPO2 and HMP groups was not significant when both kidneys from the same donor were still functioning 1-year post-transplant, but potential beneficial effects of HMPO2 were suggested by analysis of secondary outcomes. FUNDING European Commission 7th Framework Programme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Equation to Estimate Glomerular Filtration Rate
Levey, A. S., Stevens, L. A., Schmid, C. H., Zhang, Y. (., Castro, A. F., Feldman, H. I., Kusek, J. W., Eggers, P., Van Lente, F., Greene, T., et al. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-150-9-200905050-00006 · Cited by 25,603
The Clavien-Dindo Classification of Surgical Complications: Five-Year Experience
Clavien, P. A., Barkun, J., de Oliveira, M. L., Vauthey, J. N., Dindo, D., Schulick, R. D., de Santibañes, E., Pekolj, J., Slankamenac, K., Bassi, C., et al. (2009) · Annals of Surgery · doi:10.1097/sla.0b013e3181b13ca2 · Cited by 11,482
Mitochondria are the powerhouses of immunity
Mills, E. L., Kelly, B., & O'Neill, L. A. J. (2017) · Nature Immunology · doi:10.1038/ni.3704 · Cited by 1,161
Machine Perfusion or Cold Storage in Deceased-Donor Kidney Transplantation
Moers, C., Smits, J. M., Maathuis, M.-H. J., Treckmann, J., van Gelder, F., Napieralski, B. P., van Kasterop-Kutz, M., van der Heide, J. J. H., Squifflet, J.-P., van Heurn, E., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0802289 · Cited by 1,020
Self-citationJochmans, I., Moers, C., Smits, J. M., Leuvenink, H. G. D., Treckmann, J., Paul, A., Rahmel, A., Squifflet, J.-P., van Heurn, E., Monbaliu, D., et al. (2010) · Annals of Surgery · doi:10.1097/sla.0b013e3181ffc256 · Cited by 314
Self-citationCoemans, M., Süsal, C., Döhler, B., Anglicheau, D., Giral, M., Bestard, O., Legendre, C., Emonds, M.-P., Kuypers, D., Molenberghs, G., et al. (2018) · Kidney International · doi:10.1016/j.kint.2018.05.018 · Cited by 286
Self-citationDelayed graft function and the risk of acute rejection in the modern era of kidney transplantation
Wu, W. K., Famure, O., Li, Y., & Kim, S. J. (2015) · Kidney International · doi:10.1038/ki.2015.190 · Cited by 240
Machine perfusion preservation versus static cold storage for deceased donor kidney transplantation
Tingle, S. J., Figueiredo, R. S., Moir, J. A., Goodfellow, M., Talbot, D., & Wilson, C. H. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011671.pub2 · Cited by 239
Performance of Creatinine-Based GFR Estimating Equations in Solid-Organ Transplant Recipients
Shaffi, K., Uhlig, K., Perrone, R. D., Ruthazer, R., Rule, A., Lieske, J. C., Navis, G., Poggio, E. D., Inker, L. A., & Levey, A. S. (2014) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2014.01.436 · Cited by 125
Lefaucheur, C., Gosset, C., Rabant, M., Viglietti, D., Verine, J., Aubert, O., Louis, K., Glotz, D., Legendre, C. M., Huyen, J. D. V., et al. (2017) · American Journal of Transplantation · doi:10.1111/ajt.14565 · Cited by 101
Thuillier, R., Allain, G., Celhay, O., Hébrard, W., Barrou, B., Badet, L., Leuvenink, H. G. D., & Hauet, T. (2013) · Journal of Surgical Research · doi:10.1016/j.jss.2013.04.071 · Cited by 100
Self-citationRenal Ischemia-Reperfusion Injury Amplifies the Humoral Immune Response
Fuquay, R., Renner, B., Kulik, L. N., McCullough, J. W., Amura, C. R., Strassheim, D., Pelanda, R., Torres, R. M., & Thurman, J. M. (2013) · Journal of the American Society of Nephrology · doi:10.1681/asn.2012060560 · Cited by 98
Cippà, P. E., Liu, J., Sun, B., Kumar, S., Naesens, M., & McMahon, A. P. (2019) · Nature Communications · doi:10.1038/s41467-019-09092-2 · Cited by 93
The Initiating Dialysis Early and Late (Ideal) Study: Study Rationale and Design
Cooper, B. A., Branley, P., Bulfone, L., Collins, J. F., Craig, J. C., Dempster, J., Fraenkel, M. B., Harris, A., Harris, D. C. H., Johnson, D. W., et al. (2004) · Peritoneal Dialysis International · doi:10.1177/089686080402400209 · Cited by 84
Heylen, L., Jochmans, I., Samuel, U., Tieken, I., Naesens, M., Pirenne, J., & Sprangers, B. (2017) · American Journal of Transplantation · doi:10.1111/ajt.14526 · Cited by 83
Self-citationThe Effects of Oxygenation on Ex Vivo Kidneys Undergoing Hypothermic Machine Perfusion
Patel, K., Smith, T. B., Neil, D., Thakker, A., Tsuchiya, Y., Higgs, E. B., Hodges, N. J., Ready, A. R., Nath, J., & Ludwig, C. (2018) · Transplantation · doi:10.1097/tp.0000000000002542 · Cited by 67
de Kok, M. J. C., McGuinness, D., Shiels, P. G., de Vries, D. K., Nolthenius, J. T., Wijermars, L. G. M., Rabelink, T. J., Verschuren, L., Stevenson, K. S., Kingsmore, D. B., et al. (2019) · Annals of Surgery · doi:10.1097/sla.0000000000003515 · Cited by 55
Self-citationDarius, T., Gianello, P., Vergauwen, M., Mourad, N. I., Buémi, A., Meyer, M. D., & Mourad, M. (2018) · American Journal of Transplantation · doi:10.1111/ajt.15100 · Cited by 51
Self-citationKron, P., Schlegel, A. A., Muller, X., Gaspert, A., Clavien, P., & Dutkowski, P. (2019) · Transplantation · doi:10.1097/tp.0000000000002634 · Cited by 48
Machine Perfusion: Not Just for Marginal Kidney Donors
Cannon, R. M., Brock, G. N., Garrison, R. N., Marvin, M. R., Franklin, G. A., & Davis, E. G. (2015) · The American Surgeon · doi:10.1177/000313481508100616 · Cited by 18
Cited by
Czigany, Z., Pratschke, J., Froněk, J., Guba, M., Schöning, W., Raptis, D. A., Andrassy, J., Kramer, M., Strnad, P., Tolba, R. H., et al. (2021) · Annals of Surgery · doi:10.1097/sla.0000000000005110 · Cited by 255
Schlegel, A., Mueller, M., Muller, X., Eden, J., Panconesi, R., von Felten, S., Steigmiller, K., Sousa Da Silva, R. X., de Rougemont, O., Mabrut, J.-Y., et al. (2023) · Journal of Hepatology · doi:10.1016/j.jhep.2022.12.030 · Cited by 189
Self-citationOniscu, G. C., Mehew, J., Butler, A. J., Sutherland, A., Gaurav, R., Hogg, R., Currie, I., Jones, M., & Watson, C. J. E. (2023) · Transplantation · doi:10.1097/tp.0000000000004280 · Cited by 177
Metadata
- Authors
- Jochmans, I., Brat, A., Davies, L., Hofker, H. S., van de Leemkolk, F. E. M., Leuvenink, H. G. D., Knight, S. R., Pirenne, J., Ploeg, R. J., Abramowicz, D., Banga, N., Bemelman, F. J., Betjes, M. G., Burns, R., Chiocchia, V., Christiaans, M. H., Darius, T., de Jonge, J., de Vries, A. P., Detry, O., Hilbrands, L. B., Hofker, H. S., Hoksbergen, A. W., Huurman, V. A., Idu, M. M., Jacobs-Tulleneers-Thevissen, D., Jochmans, I., Kaisar, M., Kanaan, N., Kimenai, D., Kuypers, D., Le Moine, A., Marshall, C., Meurisse, N., Mikhalski, D., Moers, C., Monbaliu, D., Nijboer, W. N., Nurmohamed, S. A., O'Callaghan, J., Papalois, V., Pipeleers, L., Poyck, P. P., Quiroga, I., Randon, C., Schurink, G. W., Seelen, M., Szabo, L., Toorop, R. J., van de Poll, M. C., van der Jagt, M. F., Van Laecke, S., van Zuilen, A. D., Weekers, L., & Ysebaert, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2020-11
- Volume
- 396
- Issue
- 10263
- Pages
- 1653-1662
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W3090248241
- Cited by
- 203
- References
- 20
- FWCI
- 24.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.