The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Hypothermic Oxygenated Machine Perfusion Reduces Early Allograft Injury and Improves Post-transplant Outcomes in Extended Criteria Donation Liver Transplantation From Donation After Brain Death: Results From a Multicenter Randomized Controlled Trial (HOPE ECD-DBD)
Abstract
Objective: The aim of this study was to evaluate peak serum alanine aminotransferase (ALT) and postoperative clinical outcomes after hypothermic oxygenated machine perfusion (HOPE) versus static cold storage (SCS) in extended criteria donation (ECD) liver transplantation (LT) from donation after brain death (DBD). Background: HOPE might improve outcomes in LT, particularly in high-risk settings such as ECD organs after DBD, but this hypothesis has not yet been tested in a randomized controlled clinical trial (RCT). Methods: Between September 2017 and September 2020, 46 patients undergoing ECD-DBD LT from four centers were randomly assigned to HOPE (n = 23) or SCS (n = 23). Peak-ALT levels within 7 days following LT constituted the primary endpoint. Secondary endpoints included incidence of postoperative complications [Clavien-Dindo classification (CD), Comprehensive Complication Index (CCI)], length of intensive care- (ICU) and hospital-stay, and incidence of early allograft dysfunction (EAD). Results: Demographics were equally distributed between both groups [donor age: 72 (IQR: 59–78) years, recipient age: 62 (IQR: 55–65) years, labMELD: 15 (IQR: 9–25), 38 male and 8 female recipients]. HOPE resulted in a 47% decrease in serum peak ALT [418 (IQR: 221–828) vs 796 (IQR: 477–1195) IU/L, P = 0.030], a significant reduction in 90-day complications [44% vs 74% CD grade ≥3, P = 0.036; 32 (IQR: 12–56) vs 52 (IQR: 35–98) CCI, P = 0.021], and shorter ICU- and hospital-stays [5 (IQR: 4–8) vs 8 (IQR: 5–18) days, P = 0.045; 20 (IQR: 16–27) vs 36 (IQR: 23–62) days, P = 0.002] compared to SCS. A trend toward reduced EAD was observed for HOPE (17% vs 35%; P = 0.314). Conclusion: This multicenter RCT demonstrates that HOPE, in comparison to SCS, significantly reduces early allograft injury and improves post-transplant outcomes in ECD-DBD liver transplantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Clavien-Dindo Classification of Surgical Complications: Five-Year Experience
Clavien, P. A., Barkun, J., de Oliveira, M. L., Vauthey, J. N., Dindo, D., Schulick, R. D., de Santibañes, E., Pekolj, J., Slankamenac, K., Bassi, C., et al. (2009) · Annals of Surgery · doi:10.1097/sla.0b013e3181b13ca2 · Cited by 11,482
Boutron, I., Moher, D., Altman, D. G., Schulz, K. F., Ravaud, P., & for the CONSORT Group* (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-148-4-200802190-00008 · Cited by 2,292
The Comprehensive Complication Index: A Novel Continuous Scale to Measure Surgical Morbidity
Slankamenac, K., Graf, R., Barkun, J., Puhan, M. A., & Clavien, P.-A. (2013) · Annals of Surgery · doi:10.1097/sla.0b013e318296c732 · Cited by 1,773
Olthoff, K. M., Kulik, L., Samstein, B., Kaminski, M., Abecassis, M., Emond, J., Shaked, A., & Christie, J. D. (2010) · Liver Transplantation · doi:10.1002/lt.22091 · Cited by 1,256
A randomized trial of normothermic preservation in liver transplantation
for the Consortium for Organ Preservation in Europe, Nasralla, D., Coussios, C. C., Mergental, H., Akhtar, M. Z., Butler, A. J., Ceresa, C. D. L., Chiocchia, V., Dutton, S. J., García-Valdecasas, J. C., et al. (2018) · Nature · doi:10.1038/s41586-018-0047-9 · Cited by 1,199
Challenges in evaluating surgical innovation
Ergina, P. L., Cook, J. A., Blazeby, J. M., Boutron, I., Clavien, P.-A., Reeves, B. C., & Seiler, C. M. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61086-2 · Cited by 653
Hypothermic Machine Perfusion in Liver Transplantation — A Randomized Trial
van Rijn, R., Schurink, I. J., de Vries, Y., van den Berg, A. P., Cortes Cerisuelo, M., Darwish Murad, S., Erdmann, J. I., Gilbo, N., de Haas, R. J., Heaton, N., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2031532 · Cited by 649
Hypothermic Machine Preservation in Human Liver Transplantation: The First Clinical Series
Guarrera, J. V., Henry, S. D., Samstein, B., Odeh-Ramadan, R., Kinkhabwala, M., Goldstein, M. J., Ratner, L. E., Renz, J. F., Lee, H. T., Brown, R. S., et al. (2010) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2009.02932.x · Cited by 555
Dutkowski, P., Oberkofler, C. E., Slankamenac, K., Puhan, M. A., Schadde, E., Müllhaupt, B., Geier, A., & Clavien, P. A. (2011) · Annals of Surgery · doi:10.1097/sla.0b013e3182365081 · Cited by 424
Dutkowski, P., Polak, W. G., Muiesan, P., Schlegel, A., Verhoeven, C. J., Scalera, I., DeOliveira, M. L., Kron, P., & Clavien, P.-A. (2015) · Annals of Surgery · doi:10.1097/sla.0000000000001473 · Cited by 377
Cited by
EASL Clinical Practice Guidelines on acute-on-chronic liver failure
Moreau, R., Tonon, M., Krag, A., Angeli, P., Berenguer, M., Berzigotti, A., Fernandez, J., Francoz, C., Gustot, T., Jalan, R., et al. (2023) · Journal of Hepatology · doi:10.1016/j.jhep.2023.04.021 · Cited by 375
EASL Clinical Practice Guidelines on liver transplantation
Samuel, D., De Martin, E., Berg, T., Berenguer, M., Burra, P., Fondevila, C., Heimbach, J. K., Pageaux, G.-P., Sanchez-Fueyo, A., & Toso, C. (2024) · Journal of Hepatology · doi:10.1016/j.jhep.2024.07.032 · Cited by 263
Metadata
- Authors
- Czigany, Z., Pratschke, J., Froněk, J., Guba, M., Schöning, W., Raptis, D. A., Andrassy, J., Kramer, M., Strnad, P., Tolba, R. H., Liu, W., Keller, T., Miller, H., Pavicevic, S., Uluk, D., Kocik, M., Lurje, I., Trautwein, C., Mehrabi, A., Popescu, I., Vondran, F. W. R., Ju, C., Tacke, F., Neumann, U. P., & Lurje, G.
- Venue
- Annals of Surgery
- Published
- 2021-07-29
- Volume
- 274
- Issue
- 5
- Pages
- 705-712
- ISSN
- 0003-4932 (ISSN-L)
- 1528-1140
- OpenAlex
- W3192688392
- Cited by
- 255
- References
- 31
- FWCI
- 36.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hypothermic Oxygenated Machine Perfusion Reduces Early Allograft Injury and Improves Post-transplant Outcomes in Extended Criteria Donation Liver Transplantation From Donation After Brain Death: Results From a Multicenter Randomized Controlled Trial (HOPE ECD-DBD). https://app.cochat.ai/papers/10.1097/sla.0000000000005110
- The paper
- Czigany, Z., Pratschke, J., Froněk, J., Guba, M., Schöning, W., Raptis, D. A., Andrassy, J., Kramer, M., Strnad, P., Tolba, R. H., Liu, W., Keller, T., Miller, H., Pavicevic, S., Uluk, D., Kocik, M., Lurje, I., Trautwein, C., Mehrabi, A., . . . Lurje, G. (2021). Hypothermic Oxygenated Machine Perfusion Reduces Early Allograft Injury and Improves Post-transplant Outcomes in Extended Criteria Donation Liver Transplantation From Donation After Brain Death: Results From a Multicenter Randomized Controlled Trial (HOPE ECD-DBD). Annals of Surgery. https://doi.org/10.1097/sla.0000000000005110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.