The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Remote haemodynamic monitoring of pulmonary artery pressures in patients with chronic heart failure (MONITOR-HF): a randomised clinical trial
Open accessAbstract
BACKGROUND The effect of haemodynamic monitoring of pulmonary artery pressure has predominantly been studied in the USA. There is a clear need for randomised trial data from patients treated with contemporary guideline-directed-medical-therapy with long-term follow-up in a different health-care system. METHODS MONITOR-HF was an open-label, randomised trial, done in 25 centres in the Netherlands. Eligible patients had chronic heart failure of New York Heart Association class III and a previous heart failure hospitalisation, irrespective of ejection fraction. Patients were randomly assigned (1:1) to haemodynamic monitoring (CardioMEMS-HF system, Abbott Laboratories, Abbott Park, IL, USA) or standard care. All patients were scheduled to be seen by their clinician at 3 months and 6 months, and every 6 months thereafter, up to 48 months. The primary endpoint was the mean difference in the Kansas City Cardiomyopathy Questionnaire (KCCQ) overall summary score at 12 months. All analyses were by intention-to-treat. This trial was prospectively registered under the clinical trial registration number NTR7673 (NL7430) on the International Clinical Trials Registry Platform. FINDINGS Between April 1, 2019, and Jan 14, 2022, we randomly assigned 348 patients to either the CardioMEMS-HF group (n=176 [51%]) or the control group (n=172 [49%]). The median age was 69 years (IQR 61-75) and median ejection fraction was 30% (23-40). The difference in mean change in KCCQ overall summary score at 12 months was 7·13 (95% CI 1·51-12·75; p=0·013) between groups (+7·05 in the CardioMEMS group, p=0·0014, and -0·08 in the standard care group, p=0·97). In the responder analysis, the odds ratio (OR) of an improvement of at least 5 points in KCCQ overall summary score was OR 1·69 (95% CI 1·01-2·83; p=0·046) and the OR of a deterioration of at least 5 points was 0·45 (0·26-0·77; p=0·0035) in the CardioMEMS-HF group compared with in the standard care group. The freedom of device-related or system-related complications and sensor failure were 97·7% and 98·8%, respectively. INTERPRETATION Haemodynamic monitoring substantially improved quality of life and reduced heart failure hospitalisations in patients with moderate-to-severe heart failure treated according to contemporary guidelines. These findings contribute to the aggregate evidence for this technology and might have implications for guideline recommendations and implementation of remote pulmonary artery pressure monitoring. FUNDING The Dutch Ministry of Health, Health Care Institute (Zorginstituut), and Abbott Laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
Dapagliflozin in Patients with Heart Failure and Reduced Ejection Fraction
McMurray, J. J. V., Solomon, S. D., Inzucchi, S. E., Køber, L., Kosiborod, M. N., Martinez, F. A., Ponikowski, P., Sabatine, M. S., Anand, I. S., Bělohlávek, J., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1911303 · Cited by 7,140
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
Angiotensin–Neprilysin Inhibition in Heart Failure with Preserved Ejection Fraction
Solomon, S. D., McMurray, J. J. V., Anand, I. S., Ge, J., Lam, C. S. P., Maggioni, A. P., Martinez, F., Packer, M., Pfeffer, M. A., Pieske, B., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1908655 · Cited by 2,430
Green, C. P., Porter, C. B., Bresnahan, D. R., & Spertus, J. A. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00531-3 · Cited by 1,827
Abraham, W. T., Adamson, P. B., Bourge, R. C., Aaron, M. F., Costanzo, M. R., Stevenson, L. W., Strickland, W., Neelagaru, S., Raval, N., Krueger, S., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60101-3 · Cited by 1,744
Structured telephone support or non-invasive telemonitoring for patients with heart failure
Inglis, S. C., Clark, R. A., Dierckx, R., Prieto-Merino, D., & Cleland, J. G. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007228.pub3 · Cited by 453
Nassif, M. E., Windsor, S. L., Tang, F., Khariton, Y., Husain, M., Inzucchi, S. E., McGuire, D. K., Pitt, B., Scirica, B. M., Austin, B., et al. (2019) · Circulation · doi:10.1161/circulationaha.119.042929 · Cited by 424
Kotb, A., Cameron, C., Hsieh, S., & Wells, G. (2015) · PLOS ONE · doi:10.1371/journal.pone.0118681 · Cited by 149
Cited by
Maddox, T. M., Januzzi, J. L., Allen, L. A., Breathett, K., Brouse, S., Butler, J., Davis, L. L., Fonarow, G. C., Ibrahim, N. E., Lindenfeld, J., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.12.024 · Cited by 362
Transforming Cardiovascular Care With Artificial Intelligence: From Discovery to Practice
Khera, R., Oikonomou, E. K., Nadkarni, G. N., Morley, J. R., Wiens, J., Butte, A. J., & Topol, E. J. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.05.003 · Cited by 264
Artificial intelligence-enhanced patient evaluation: bridging art and science
Oikonomou, E. K., & Khera, R. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae415 · Cited by 34
Digital tools in heart failure: addressing unmet needs
Myhre, P. L., Tromp, J., Ouwerkerk, W., Ting, D. S. W., Docherty, K. F., Gibson, C. M., & Lam, C. S. P. (2024) · The Lancet Digital Health · doi:10.1016/s2589-7500(24)00158-4 · Cited by 31
Metadata
- Authors
- Brugts, J. J., Radhoe, S. P., Clephas, P. R. D., Aydin, D., van Gent, M. W. F., Szymanski, M. K., Rienstra, M., van den Heuvel, M. H., da Fonseca, C. A., Linssen, G. C. M., Borleffs, C. J. W., Boersma, E., Asselbergs, F. W., Mosterd, A., Brunner-La Rocca, H.-P., de Boer, R. A., Emans, M. E., Beeres, S. L. M. A., Heerebeek, L., Kirchhof, C., Van Ramshorst, J., Spee, R., Smilde, T., Van Eck, M., Kaplan, E., Hazeleger, R., Tukkie, R., Feenema, M., Kok, W., Van Halm, V, Handoko, M. L., Van Kimmenade, R., Post, M., Van Mieghem, N., & Manintveld, O. C.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2023-06
- Volume
- 401
- Issue
- 10394
- Pages
- 2113-2123
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W4377141342
- Cited by
- 248
- References
- 9
- FWCI
- 43.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Remote haemodynamic monitoring of pulmonary artery pressures in patients with chronic heart failure (MONITOR-HF): a randomised clinical trial. https://app.cochat.ai/papers/10.1016/s0140-6736(23)00923-6
- The paper
- Brugts, J. J., Radhoe, S. P., Clephas, P. R. D., Aydin, D., van Gent, M. W. F., Szymanski, M. K., Rienstra, M., van den Heuvel, M. H., da Fonseca, C. A., Linssen, G. C. M., Borleffs, C. J. W., Boersma, E., Asselbergs, F. W., Mosterd, A., Brunner-La Rocca, H.-P., de Boer, R. A., Emans, M. E., Beeres, S. L. M. A., Heerebeek, L., . . . Manintveld, O. C. (2023). Remote haemodynamic monitoring of pulmonary artery pressures in patients with chronic heart failure (MONITOR-HF): a randomised clinical trial. The Lancet. https://doi.org/10.1016/s0140-6736(23)00923-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.