STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 9,901–10,000 of 47,868
Applying fractal analysis to short sets of heart rate variability data
Peña, M. A., Echeverría, J. C., García, M. T., & González-Camarena, R. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0436-1 · Cited by 54
Li, Y., Shi, J., Duan, X., & Fan, F. (2010) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-009-1243-y · Cited by 50
Automated measurements of follicle diameter: a chance to standardize?
Raine‐Fenning, N., Jayaprakasan, K., Chamberlain, S., Devlin, L., Priddle, H., & Johnson, I. R. (2008) · Fertility and Sterility · doi:10.1016/j.fertnstert.2008.07.1719 · Cited by 50
Nevill, A. M., Beech, C., Holder, R. L., & Wyon, M. A. (2010) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/j.1600-0838.2008.00874.x · Cited by 55
Within-Subject Interlaboratory Variability of QuantiFERON-TB Gold In-Tube Tests
Whitworth, W. C., Hamilton, L. R., Goodwin, D. J., Barrera, C., West, K. B., Racster, L., Daniels, L. J., Chuke, S. O., Campbell, B. H., Bohanon, J., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0043790 · Cited by 51
Comparison of Rectal and Infrared Ear Temperatures in Older Hospital Inpatients
Smitz, S., Giagoultsis, T., Dewé, W., & Albert, A. (2000) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2000.tb03030.x · Cited by 56
Auboiroux, V., Viallon, M., Roland, J., Hyacinthe, J., Petrusca, L., Morel, D. R., Goget, T., Terraz, S., Gross, P., Becker, C., et al. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23309 · Cited by 57
Kim, S.-C., Heinze, I., Schmiedel, A., Baumgarten, G., Knuefermann, P., Hoeft, A., & Weber, S. U. (2014) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000042 · Cited by 50
Pasero, D., Koeltz, A., Plácido, R., Neville, M. F. L., Haun, O., Rienzo, M., Marrache, D., Pirracchio, R., Safran, D., & Cholley, B. (2015) · Intensive Care Medicine · doi:10.1007/s00134-014-3625-9 · Cited by 50
Christensen, S. E., Möller, E., Bonn, S. E., Ploner, A., Bälter, O., Lissner, L., & Bälter, K. A. (2014) · Journal of Medical Internet Research · doi:10.2196/jmir.2965 · Cited by 53
Huang, E. P., Wang, X. F., Choudhury, K. R., McShane, L. M., Gönen, M., Ye, J., Buckler, A. J., Kinahan, P. E., Reeves, A. P., Jackson, E. F., et al. (2014) · Statistical Methods in Medical Research · doi:10.1177/0962280214537394 · Cited by 58
Machila, N., Fèvre, E. M., Maudlin, I., & Eisler, M. C. (2008) · Preventive Veterinary Medicine · doi:10.1016/j.prevetmed.2008.06.001 · Cited by 63
Factors associated with voice-related quality of life among teachers with voice complaints
Cantor-Cutiva, L. C., & Alex Burdorf, A. (2014) · Journal of Communication Disorders · doi:10.1016/j.jcomdis.2014.05.003 · Cited by 56
Lu, T.-L. C., Rizzo, E., Marques-Vidal, P. M., von Segesser, L. K., Dehmeshki, J., & Qanadli, S. D. (2009) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2009.216275 · Cited by 50
Meyer, C. R., Armato, S. G., Fenimore, C. P., McLennan, G., Bidaut, L. M., Barboriak, D. P., Gavrielides, M. A., Jackson, E. F., McNitt‐Gray, M. F., Kinahan, P. E., et al. (2009) · Translational Oncology · doi:10.1593/tlo.09208 · Cited by 54
Peršić, S., Palac, A., Bunjevac, T., & Čelebić, A. (2013) · Community Dentistry And Oral Epidemiology · doi:10.1111/cdoe.12048 · Cited by 56
Fat Deposition in Dilated Cardiomyopathy Assessed by CMR
Lu, M., Zhao, S., Jiang, S.-L., Yin, G., Wang, C., Zhang, Y., Liu, Q., Cheng, H., Ma, N., Zhao, T., et al. (2013) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2013.04.010 · Cited by 50
Bent, N. P., Wright, C. C., Rushton, A., & Batt, M. E. (2009) · British Journal of Sports Medicine · doi:10.1136/bjsm.2009.057356 · Cited by 68
Ohte, N., Saeki, T., Miyabe, H., Sakata, S., Mukai, S., Hayano, J., Niki, K., Sugawara, M., & Kimura, G. (2007) · Heart and Vessels · doi:10.1007/s00380-007-0998-5 · Cited by 58
Frikha, Z., Girerd, N., Huttin, O., Courand, P., Bozec, E., Olivier, A., Lamiral, Z., Zannad, F. M., & Rossignol, P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0122336 · Cited by 58
Candotti, C. T., Loss, J. F., Melo, M. D. O., Torre, M. L., Pasini, M., Dutra, L. A., de Oliveira, J. L. N., & de Oliveira, L. P. (2008) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y08-020 · Cited by 50
Meyer, N., Lauwers‐Cancès, V., Lourari, S., Laurent, J., Konstantinou, M. P., Lagarde, J., Krief, B., Batatia, H., Lamant, L., & Paul, C. F. (2014) · British Journal of Dermatology · doi:10.1111/bjd.13129 · Cited by 54
Silvilairat, S., Cabalka, A. K., Cetta, F., Hagler, D., & O’Leary, P. W. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.03.041 · Cited by 50
Sonographic assessment of uterine and ovarian development in normal girls aged 1 to 12 years
Badouraki, M., Christoforidis, A., Economou, I., Dimitriadis, A. S., & Katzos, G. S. (2008) · Journal of Clinical Ultrasound · doi:10.1002/jcu.20522 · Cited by 50
Should We Continue to Use the Cockcroft-Gault Formula?
Hélou, R. (2010) · Nephron Clinical Practice · doi:10.1159/000317197 · Cited by 50
Critical Transitions in Early Embryonic Aortic Arch Patterning and Hemodynamics
Kowalski, W. J., Dur, O., Wang, Y., Patrick, M. J., Tinney, J. P., Keller, B. B., & Pekkan, K. (2013) · PLoS ONE · doi:10.1371/journal.pone.0060271 · Cited by 51
Giorgetti, A., Masci, P. G., Marras, G., Rustamova, Y., Gimelli, A., Genovesi, D., Lombardi, M., & Marzullo, P. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2505-9 · Cited by 50
Bone, R. A., Brener, B., & Gibert, J. C. (2007) · Vision Research · doi:10.1016/j.visres.2007.09.002 · Cited by 50
Martinelli, N., Scotto, G. M., Sartorelli, E., Bonifacini, C. C., Bianchi, A., & Malerba, F. (2013) · Quality of Life Research · doi:10.1007/s11136-013-0435-4 · Cited by 50
Autofluorescence Imaging of Choroidal Neovascularization Due to Age-Related Macular Degeneration
Dandekar, S. S., Jenkins, S. A., Peto, T., Scholl, H. P. N., Sehmi, K. S., Fitzke, F. W., Bird, A. C., & Webster, A. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.11.1507 · Cited by 54
Variability in echocardiographic measurements of left ventricular function in septic shock patients
Geer, L. D., Oscarsson, A., & Engvall, J. E. (2015) · Cardiovascular Ultrasound · doi:10.1186/s12947-015-0015-6 · Cited by 53
Segmentation of ultrasound images of the carotid using RANSAC and cubic splines
Rocha, R., Campilho, A., Silva, J. A., Azevedo, E. I., & dos Santos, R. M. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.04.015 · Cited by 56
First-night effect in the chronic fatigue syndrome
Bon, O. L., Minner, P., Moorsel, C. V., Hoffmann, G., Gallego, S., Lambrecht, L., Pelc, I., & Linkowski, P. (2003) · Psychiatry Research · doi:10.1016/s0165-1781(03)00185-9 · Cited by 56
Shoulder muscle endurance: the development of a standardized and reliable protocol
Roy, J., Ma, B., MacDermid, J. C., & Woodhouse, L. J. (2011) · Sports Medicine Arthroscopy Rehabilitation Therapy & Technology · doi:10.1186/1758-2555-3-1 · Cited by 50
Rizzo, M. R., Paolisso, G., Grella, R., Barbieri, M., Grella, R., Ragno, E., Grella, R., Nicoletti, G., & D’Andrea, F. (2005) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2005.02337.x · Cited by 55
Müller, W., Horn, M., Fürhapter-Rieger, A., Kainz, P., Kröpfl, J. M., Ackland, T. R., Lohman, T. G., Maughan, R. J., Meyer, N. L., Sundgot-Borgen, J., et al. (2013) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-092233 · Cited by 49
Kinematic characteristics of elite men's 50 km race walking
Hanley, B., Bissas, A., & Drake, A. (2011) · European Journal of Sport Science · doi:10.1080/17461391.2011.630104 · Cited by 50
Reliability of Respiratory Polygraphy for the Diagnosis of Sleep Apnea-Hypopnea Syndrome in Children
Álvarez, M. L. A., Santos, J. T., Guevara, J. A. C., Eguía, A. I. N., Carbajo, E. O., Jiménez, J. F. M., & Pelayo, R. (2008) · Archivos de Bronconeumología · doi:10.1016/s1579-2129(08)60052-x · Cited by 55
Sevrukov, A., Bland, M., & Kondos, G. T. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.04.1589 · Cited by 50
Evaluation of the European Heart Failure Self‐care Behaviour Scale in a United Kingdom population
Shuldham, C. M., Theaker, C., Jaarsma, T., & Cowie, M. (2007) · Journal of Advanced Nursing · doi:10.1111/j.1365-2648.2007.04371.x · Cited by 66
Sommer, A., Kronborg, M. B., Nørgaard, B. L., Gerdes, C., Mortensen, P. T., & Nielsen, J. C. (2014) · EP Europace · doi:10.1093/europace/euu056 · Cited by 51
Validity of Hand‐to‐Foot Measurement of Bioimpedance: Standing Compared with Lying Position
Rush, E. C., Crowley, J., Freitas, I. F., & Luke, A. (2006) · Obesity · doi:10.1038/oby.2006.32 · Cited by 49
Sihan, K., Botha, C. P., Post, F. H., de Winter, S., Gonzalo, N., Regar, E. S., Serruys, P. W. J. C., Hamers, R., & Bruining, N. (2009) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22125 · Cited by 50
Hyhlik-Dürr, A., Krieger, T., Geisbüsch, P., Kotelis, D., Able, T., & Böckler, D. (2011) · Journal of Endovascular Therapy · doi:10.1583/10-3384mr.1 · Cited by 50
Measurement of calcitonin by immunoassay analyzers
Bieglmayer, C., Vierhapper, H., Dudczak, R., & Niederle, B. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.124 · Cited by 50
Rata, M., Collins, D. J., d’Arcy, J. A., Messiou, C., Tunariu, N., deSouza, N. M., Young, H. E., Leach, M. O., & Orton, M. R. (2015) · European Radiology · doi:10.1007/s00330-015-4012-9 · Cited by 50
de Jong-Pleij, E., Ribbert, L. S. M., Tromp, E., & Bilardo, C. M. (2009) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.7471 · Cited by 50
Patel, A. R., Tee, B. C., Fields, H. W., Jones, E., Chaudhry, J., & Sun, Z. (2014) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2013.10.014 · Cited by 50
Jung, K. I., Lim, S. A., Park, H. L., & Park, C. K. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.10.015 · Cited by 50
Engesæter, I. Ø., Laborie, L. B., Lehmann, T. G., Sera, F., Fevang, J. M., Pedersen, D. R., Morcuende, J. A., Lie, S. A., Engesaeter, L. B., & Rosendahl, K. (2011) · Skeletal Radiology · doi:10.1007/s00256-011-1283-3 · Cited by 50
Freedman, D. S., Ogden, C. L., & Kit, B. K. (2015) · BMC Pediatrics · doi:10.1186/s12887-015-0493-6 · Cited by 64
Skyttä, E. T., Haapamäki, V. V., Koivikko, M. P., Huhtala, H. S. A., & Remes, V. (2011) · PubMed · Cited by 50
Ste‐Marie, D. M., Carter, M. J., Law, B., Vertes, K. A., & Smith, V. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1130236 · Cited by 66
Charles, E. R., Kumar, V., Blacknall, J., Edwards, K., Geoghegan, J. M., Manning, P. A., & Wallace, W. A. (2017) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2017.03.036 · Cited by 55
Pearson, K., Long, M., Prasad, J. P., Wu, Y. Y., & Bonifacio, M. (2016) · Reproductive Biology and Endocrinology · doi:10.1186/s12958-016-0143-3 · Cited by 57
Hoffer, K. J., Shammas, J. H., Savini, G., & Huang, J. (2016) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2015.07.041 · Cited by 50
Mirzazadeh, M., Morovat, A., James, T., Smith, I., Kirby, J., & Shine, B. (2016) · Emergency Medicine Journal · doi:10.1136/emermed-2015-204669 · Cited by 48
Ad hoc procedure for optimising agreement between observational records
Arana, J., Ajamil, D. L., Anguera, M. T., & Garzón, B. (2016) · Anales de Psicología · doi:10.6018/analesps.32.2.213551 · Cited by 58
Baldelli, S., Cattaneo, D., Giodini, L., Baietto, L., Perri, G. D., D’Avolio, A., & Clementi, E. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0472 · Cited by 50
Esco, M. R., Flatt, A. A., & Nakamura, F. Y. (2016) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001519 · Cited by 55
Mankodi, A. K., Bishop, C., Auh, S., Newbould, R. D., Fischbeck, K. H., & Janiczek, R. L. (2016) · Neuromuscular Disorders · doi:10.1016/j.nmd.2016.07.013 · Cited by 50
Balaguier, R., Madeleine, P., & Vuillerme, N. (2016) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-016-1212-7 · Cited by 57
Development and Evaluation of e-CA, an Electronic Mobile-Based Food Record
Torre, S. B. D., Carrard, I., Farina, E., Danuser, B., & Kruseman, M. (2017) · Nutrients · doi:10.3390/nu9010076 · Cited by 56
Severini, G., Straudi, S., Pavarelli, C., Roit, M. D., Martinuzzi, C., Pizzongolo, L. D. M., & Basaglia, N. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0230-5 · Cited by 57
Static and Dynamic Handgrip Strength Endurance: Test-Retest Reproducibility
Gerodimos, V., Καρατράντου, Κ., Psychou, D., Vasilopoulou, T., & Zafeiridis, A. (2017) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2016.12.014 · Cited by 61
Accuracy and bias of methods used for root length measurements in functional root research
Delory, B. M., Weidlich, E. W. A., Meder, L., Lütje, A., van Duijnen, R., Weidlich, R., & Temperton, V. M. (2017) · Methods in Ecology and Evolution · doi:10.1111/2041-210x.12771 · Cited by 58
Test-Retest Reliability of the King-Devick Test in an Adolescent Population
Oberlander, T. J., Olson, B. L., & Weidauer, L. A. (2017) · Journal of Athletic Training · doi:10.4085/1062-6050-52.2.12 · Cited by 58
Rozzi, M., Mucedero, M., Pezzuto, C., & Cozza, P. (2017) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2016.09.023 · Cited by 57
Wang, Y.-C., Wickstrom, R., Yen, S., Kapellusch, J. M., & Grogan, K. A. (2017) · Journal of Hand Therapy · doi:10.1016/j.jht.2017.03.009 · Cited by 58
Boncler, M. A., Golański, J., Lukasiak, M., Redzynia, M., Dastych, J., & Watała, C. W. (2017) · PLoS ONE · doi:10.1371/journal.pone.0180022 · Cited by 50
Fatehi, F., Salort‐Campana, E., Troter, A. L., Lareau-Trudel, É., Bydder, M., Fouré, A., Guye, M., Bendahan, D., & Attarian, S. (2017) · PLoS ONE · doi:10.1371/journal.pone.0183825 · Cited by 52
Brain lesion segmentation through image synthesis and outlier detection
Bowles, C., Qin, C., Guerrero, R., Gunn, R. N., Hammers, A., Dickie, D. A., Hernández, M. V., Wardlaw, J. M., & Rueckert, D. (2017) · NeuroImage Clinical · doi:10.1016/j.nicl.2017.09.003 · Cited by 55
Schnerr, R. S., Jansen, J. F. A., Uludaǧ, K., Hofman, P. A. M., Wildberger, J. E., van Oostenbrugge, R. J., & Backes, W. H. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00961 · Cited by 57
Hoeboer, J., Krijger, M., Savelsbergh, G. J. P., & de Vries, S. I. (2017) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1406296 · Cited by 60
Essentials of Statistical Methods for Assessing Reliability and Agreement in Quantitative Imaging
Anvari, A., Halpern, E. F., & Samir, A. E. (2017) · Academic Radiology · doi:10.1016/j.acra.2017.09.010 · Cited by 53
Glutamate quantification by PRESS or MEGA-PRESS: Validation, repeatability, and concordance
van Veenendaal, T. M., Backes, W. H., van Bussel, F. C. G., Edden, R. A. E., Puts, N. A. J., Aldenkamp, A. P., & Jansen, J. F. A. (2018) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2017.12.029 · Cited by 50
Easton, T., Milte, R., Crotty, M., & Ratcliffe, J. (2018) · Quality of Life Research · doi:10.1007/s11136-017-1777-0 · Cited by 51
Wintermann, G., Rosendahl, J., Weidner, K., Strauss, B. M., Hinz, A., & Petrowski, K. (2018) · Health and Quality of Life Outcomes · doi:10.1186/s12955-018-0862-6 · Cited by 56
Park, J.-K., Seon, J., Cho, K.-J., Lee, N.-H., & Song, E. K. (2018) · Clinics in Orthopedic Surgery · doi:10.4055/cios.2018.10.2.167 · Cited by 50
A “Smart” Undershirt for Tracking Upper Body Motions: Task Classification and Angle Estimation
Esfahani, M. I. M., & Nussbaum, M. A. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2859626 · Cited by 61
Michelsen, B., Sexton, J., Smolen, J. S., Aletaha, D., Krogh, N. S., van der Heijde, D. M. F. M., Kvien, T. K., & Hetland, M. L. (2018) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2018-213463 · Cited by 50
Determination of cell viability using acridine orange/propidium iodide dual-spectrofluorometry assay
Hussain, H., Santhana Raj, L., Ahmad, S., Razak, M. F. A., Mohamud, W. N. W., Bakar, J., & Ghazali, H. M. (2019) · Cogent Food & Agriculture · doi:10.1080/23311932.2019.1582398 · Cited by 58
Borszcz, F. K., Tramontin, A. F., & Costa, V. P. (2019) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2018-0572 · Cited by 60
Tinsley, G. M., Moore, M. L., Dellinger, J. R., Adamson, B. T., & Benavides, M. L. (2019) · European Journal of Clinical Nutrition · doi:10.1038/s41430-019-0526-6 · Cited by 54
Houriez—Gombaud-Saintonge, S., Mousseaux, É., Bargiotas, I., Cesare, A. D., Dietenbeck, T., Bouaou, K., Redheuil, A. B., Soulat, G., Giron, A., Gencer, U., et al. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0584-x · Cited by 57
Carkeet, A. (2019) · Optometry and Vision Science · doi:10.1097/opx.0000000000001465 · Cited by 51
Hilty, M. P., Akın, Ş., Boerma, E. C., Donati, A., Erdem, Ö., Giaccaglia, P., Guerci, P., Milstein, D. M. J., Montomoli, J., Toraman, F., et al. (2020) · Critical Care Medicine · doi:10.1097/ccm.0000000000004491 · Cited by 52
Tseng, C., Tseng, T.-J., & Wu, C.-Z. (2020) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2020.3011446 · Cited by 50
Franchi, M. V., Fitze, D. P., Hanimann, J., Sarto, F., & Spörri, J. (2020) · Scientific Reports · doi:10.1038/s41598-020-71123-6 · Cited by 57
Accuracy of Smartphone Video for Contactless Measurement of Hand Tremor Frequency
Williams, S., Fang, H., Relton, S. D., Wong, D., Alam, T., & Alty, J. (2020) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.13119 · Cited by 54
Draper, N., Giles, D., Taylor, N., Vigouroux, L., España‐Romero, V., Baláš, J., Altamirano, I. S., Mally, F., Beeretz, I., Canalejo, J. C., et al. (2021) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2020-0672 · Cited by 62
Brehm, M., Scholtes, V. A., Dallmeijer, A. J., Twisk, J. W. R., & Harlaar, J. (2011) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2011.04164.x · Cited by 50
Hansson, K. M., Vikinge, T. P., Rånby, M., Tengvall, P., Lundström, I., Johansen, K., & Lindahl, T. L. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00050-0 · Cited by 56
Variability in adherence to an unsupervised exercise prescription in obese women
Colley, R. C., Hills, A. P., O'Moore‐Sullivan, T. M., Hickman, I. J., Prins, J. B., & Byrne, N. M. (2008) · International Journal of Obesity · doi:10.1038/sj.ijo.0803799 · Cited by 58
Zanier, E. R., Ortolano, F., Ghisoni, L., Colombo, A., Losappio, S., & Stocchetti, N. (2007) · Critical Care · doi:10.1186/cc5155 · Cited by 60
Lubberink, M., Boellaard, R., van der Weerdt, A. P., Visser, F. C., & Lammertsma, A. A. (2004) · PubMed · Cited by 50
Comparison of the Axis %CDT TIA and the CDTect method as laboratory tests of alcohol abuse
Viitala, K., Lähdesmäki, K., & Niemelä, O. J. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.6.1209 · Cited by 50
Pulseoximetry: sufficient to diagnose severe sleep apnea
Øverland, B., Skatvedt, O., Kværner, K. J., & Akre, H. (2002) · Sleep Medicine · doi:10.1016/s1389-9457(01)00122-8 · Cited by 50
Landberg, R., Andersson, A. A. M., Åman, P., & Kamal‐Eldin, A. (2008) · Food Chemistry · doi:10.1016/j.foodchem.2008.08.072 · Cited by 50
Comparison of Three Methods for Differential Cell Count in Induced Sputum
Saraiva-Romanholo, B. M., Barnabé, V., de Carvalho, A. L. I., Martins, M. A., Saldiva, P. H. N., & Nunes, M. D. P. T. (2003) · CHEST Journal · doi:10.1378/chest.124.3.1060 · Cited by 50
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.