STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 10,201–10,300 of 47,868
de Laat, M. W. M., Franx, A., Nikkels, P. G. J., & Visser, G. H. A. (2006) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.2786 · Cited by 49
Ceelen, K. K., Stekelenburg, A. A., Mulders, J. L. J., Strijkers, G. J., Baaijens, F. F., Nicolay, K., & Oomens, C. W. J. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2987877 · Cited by 49
Parallel imaging of knee cartilage at 3 Tesla
Zuo, J., Li, X., Banerjee, S., Han, E. T., & Majumdar, S. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21122 · Cited by 49
On detecting interference from endogenous antibodies in immunoassays by doubling dilutions test
Ismail, A. A. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.152 · Cited by 54
The seasonal pattern assessment questionnaire for identifying seasonal affective disorders
Raheja, S. K., King, E. A., & Thompson, C. M. (1996) · Journal of Affective Disorders · doi:10.1016/s0165-0327(96)00087-0 · Cited by 63
COMPARISON OF PALMAR TILT, RADIAL INCLINATION AND ULNAR VARIANCE IN LEFT AND RIGHT WRISTS
Hollevoet, N., MAELE, G. V., SEYMORTIER, P. V., & VERDONK, R. (2000) · Journal of Hand Surgery (European Volume) · doi:10.1016/s0266-7681(00)80005-4 · Cited by 49
Brown, C. R., Hillman, S. J., Richardson, A., Herman, J., & Robb, J. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2007.08.008 · Cited by 49
Kikkawa, M., Nakamura, T., Sakamoto, K., Sugihara, H., Azuma, A., Sawada, T., Okuyama, C., Ushijima, Y., & Nishimura, T. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590100487 · Cited by 49
Woods, R. K., Weiner, J. M., Thein, F., Abramson, M. J., & Walters, E. H. (1998) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(98)70305-7 · Cited by 53
Comparison of three staining methods for the morphological evaluation of human spermatozoa
Henkel, R., Schreiber, G., Sturmhoefel, A. M., Hipler, U., Zermann, D. H., & Menkveld, R. (2007) · Fertility and Sterility · doi:10.1016/j.fertnstert.2007.03.027 · Cited by 51
LUNDBÆK, J. A., & HANSEN, A. J. (1992) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1992.tb09449.x · Cited by 48
Evaluation of a miniaturized thermal biosensor for the determination of glucose in whole blood
Harborn, U., Xie, B., VENKATESH, R., & Danielsson, B. R. G. (1997) · Clinica Chimica Acta · doi:10.1016/s0009-8981(97)00151-4 · Cited by 49
Rupérez, M., López‐Herce, J., García, C., Sánchez, C., García, E., & Vigil, D. (2003) · Pediatric Cardiology · doi:10.1007/s00246-003-0450-2 · Cited by 50
Inspiratory muscle strength in chronic obstructive pulmonary disease depending on disease severity
Kabitz, H., Walterspacher, S., Walker, D., & Windisch, W. (2007) · Clinical Science · doi:10.1042/cs20060362 · Cited by 49
Bax, L., Bakker, C. J. G., Klein, W. M., Blanken, N., Beutler, J. J., & Mali, W. P. T. M. (2005) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000161144.98350.28 · Cited by 49
Prushansky, T., Deryi, O., & Jabarreen, B. (2009) · Physiotherapy Research International · doi:10.1002/pri.443 · Cited by 49
de Ruiter, G. C., Spinner, R. J., Alaid, A. O., Koch, A., Wang, H., Malessy, M. J. A., Currier, B. L., Yaszemski, M. J., Kaufman, K. R., & Windebank, A. J. (2007) · Journal of the Peripheral Nervous System · doi:10.1111/j.1529-8027.2007.00142.x · Cited by 49
Suh, M. J., Coakley, F. V., Qayyum, A., Yeh, B. M., Breiman, R. S., & Lü, Y. (2003) · Radiology · doi:10.1148/radiol.2282020922 · Cited by 49
Sorbara, L., SIMPSON, T. L., Duench, S. A., Schulze, M., & Fonn, D. (2007) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2006.12.003 · Cited by 49
Frontomaxillary facial angles in screening for trisomy 21 at 14-23 weeks’ gestation
Sonek, J., Borenstein, M., Downing, C., McKenna, D. S., Neiger, R., Croom, C. S., Genrich, T., & Nicolaides, K. H. (2007) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2007.03.059 · Cited by 49
A Comprehensive Comparison of Central Corneal Thickness Measurement
Huang, J., Pesudovs, K., Yu, A., Wright, T., Wen, D., Li, M., Yu, Y., & Wang, Q. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e31821ffe2c · Cited by 49
The value of Bilicheck as a screening tool for neonatal jaundice in term and near-term babies
Kissack, C., Nayak, S., Chittick, R., Yoxall, C. W., Samanta, S., & Tan, M. (2004) · Acta Paediatrica · doi:10.1080/08035250410033042 · Cited by 49
Comparison of two different physical activity monitors
Paul, D. R., Kramer, M., Moshfegh, A. J., Baer, D. J., & Rumpler, W. V. (2007) · BMC Medical Research Methodology · doi:10.1186/1471-2288-7-26 · Cited by 51
Blood pressure measurement during exercise: a review
GRIFFIN, S. E., ROBERGS, R. A., & HEYWARD, V. H. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199701000-00022 · Cited by 51
Opolskiene, G., Sladkevicius, P., Jokubkiene, L., & Valentin, L. (2009) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.7445 · Cited by 49
Development and simulated validation of a food-frequency questionnaire for the Colombian population
Bautista, L. E., Herrán, O. F., & Pryer, J. A. (2005) · Public Health Nutrition · doi:10.1079/phn2004672 · Cited by 59
Poma, S. Z., Milleri, S., Squassante, L., Nucci, G., Bani, M., Perini, G. I., & Merlo-Pich, E. (2005) · Journal of Psychopharmacology · doi:10.1177/0269881105056533 · Cited by 49
Central and peripheral corneal thickness measured with the TOPCON specular microscope SP-2000P
Cho, P., & Cheung, S. W. (2000) · Current Eye Research · doi:10.1076/ceyr.21.4.799.5542 · Cited by 49
Systolic long axis function of the left ventricle. Global and regional information
Støylen, A., & Skjærpe, T. (2003) · Scandinavian Cardiovascular Journal · doi:10.1080/14017430310015000 · Cited by 49
Massart, C., & Poirier, J. Y. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2006.05.027 · Cited by 49
Lorentzen, A.-G., Lindskov, C., Sloth, E., & Jakobsen, C.-J. (2008) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2008.04.004 · Cited by 49
Measuring the size of ulcers by planimetry: a useful method in the clinical setting
Öien, R. F., Håkansson, A., Hansen, B. U., & Bjellerup, M. (2002) · Journal of Wound Care · doi:10.12968/jowc.2002.11.5.26399 · Cited by 49
Interexaminer and intraexaminer reliability of the microperimeter MP-1
Weingessel, B., Sacu, S., Vécsei‐Marlovits, P. V., Weingessel, A., Richter‐Mueksch, S., & Schmidt-Erfurth, U. M. (2008) · Eye · doi:10.1038/eye.2008.237 · Cited by 50
España‐Romero, V., Ruiz, J. R., Ortega, F. B., Artero, E. G., Vicente‐Rodríguez, G., Moreno, L. A., Castillo, M. J., & Gutiérrez, Á. (2009) · Journal of Sports Sciences · doi:10.1080/02640410802603863 · Cited by 59
del Río, M., Martínez, J. M. B., Figueras, F., Bennasar, M., Palacio, M., Gómez, O., Coll, O., Puerto, B., & Cararach, V. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1955 · Cited by 49
Lindsell, C. J., Alwell, K., Moomaw, C. J., Kleindorfer, D., Woo, D., Flaherty, M. L., Air, E. L., Schneider, A. T., Ewing, I., Broderick, J. P., et al. (2005) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2005.08.004 · Cited by 49
Bock, C. H., Parker, P. E., Cook, A. Z., & Gottwald, T. R. (2008) · Plant Disease · doi:10.1094/pdis-92-6-0927 · Cited by 49
Objective Measurement of Backscattered Light from the Anterior and Posterior Cornea In Vivo
Patel, S. V., Winter, E. J., McLaren, J. W., & Bourne, W. M. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0767 · Cited by 56
Staatz, C. E., Taylor, P. J., & Tett, S. E. (2002) · Therapeutic Drug Monitoring · doi:10.1097/00007691-200210000-00005 · Cited by 49
Axillary and Rectal Temperature Measurements Poorly Agree in Newborn Infants
Muller, P. C. E. H., van Berkel, L. H., & de Beaufort, A. J. (2008) · Neonatology · doi:10.1159/000112840 · Cited by 53
Sullivan-Mee, M., Gerhardt, G., Halverson, K. D., & Qualls, C. (2009) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31819c487d · Cited by 49
Intraocular pressure measurement in mice: a comparison between Goldmann and rebound tonometry
Kim, C. Y., Kuehn, M. H., Anderson, M. G., & Kwon, Y. H. (2006) · Eye · doi:10.1038/sj.eye.6702576 · Cited by 49
Critchley, L. A. H., Calcroft, R. M., Tan, P., Kew, J., & Critchley, J. (2000) · Intensive Care Medicine · doi:10.1007/s001340051232 · Cited by 49
Kirschbaum, S. W., Baks, T., Gronenschild, E. H. B. M., Aben, J., Weustink, A. C., Wielopolski, P. A., Krestin, G. P., de Feyter, P. J., & van Geuns, R. (2007) · Investigative Radiology · doi:10.1097/rli.0b013e318154b1dc · Cited by 49
Watzke, H., Hasenkam, M., Schwab, M., Wolf, T., Dovifat, C., Völler, H., & Braun, S. (2007) · Thrombosis and Haemostasis · doi:10.1160/th06-03-0181 · Cited by 49
Sex‐specific fetal weight prediction by ultrasound
Schild, R. L., Sachs, C., Fimmers, R., Gembruch, U., & Hansmann, M. (2004) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.942 · Cited by 55
Richards, S. H., Coast, J., & Peters, T. J. (2003) · Health & Social Care in the Community · doi:10.1046/j.1365-2524.2003.00457.x · Cited by 49
Loss of Body Cell Mass in Cushing's Syndrome: Effect of Treatment
Pirlich, M. (2002) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.87.3.1078 · Cited by 49
Dalby, K., Nielsen, R. G., Markoew, S., Kruse-Andersen, S., & Husby, S. (2007) · Digestive Diseases and Sciences · doi:10.1007/s10620-006-9731-y · Cited by 49
Serio, F. D., Ruggieri, V., Varraso, L., Sario, R. D., Mastrorilli, A., & Pansini, N. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.217 · Cited by 49
Monitoring osteoarthritis progression and therapy
Dougados, M. (2003) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2003.09.009 · Cited by 49
Invasive versus noninvasive measurement of allergic and cholinergic airway responsiveness in mice
Glaab, T., Ziegert, M., Bälder, R., Korolewitz, R., Braun, A. C., Hohlfeld, J. M., Mitzner, W., Krug, N., & Hoymann, H.-G. (2005) · Respiratory Research · doi:10.1186/1465-9921-6-139 · Cited by 49
Defining metabolic acidosis in patients with septic shock using Stewart approach
Mallat, J., Michel, D., Salaun, P., Thévenin, D., & Tronchon, L. (2011) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2010.11.039 · Cited by 56
Lee, S. J., Stepniewska, K., Anstey, N. M., Ashley, E. A., Barnes, K. I., Bình, T. Q., D’Alessandro, U., Day, N., de Vries, P. J., Dorsey, G., et al. (2008) · Malaria Journal · doi:10.1186/1475-2875-7-149 · Cited by 49
Reproducibility and reliability of pressure flow parameters in women
Digesu, G. A., Hutchings, A., Salvatore, S., Selvaggi, L. E., & Khullar, V. (2003) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1016/s1470-0328(03)02081-0 · Cited by 49
Stiffness of the large arteries in individuals with and without Down syndrome
Rodrigues, A., Coelho, Gonçalves, W. L. S., Gouvêa, Vasconcellos, Cunha, & Abreu (2011) · Vascular Health and Risk Management · doi:10.2147/vhrm.s21273 · Cited by 57
Balamoody, S., Williams, T. G., Wolstenholme, C., Waterton, J. C., Bowes, M. A., Hodgson, R. J., Zhao, S., Scott, M. L. J., Taylor, C., & Hutchinson, C. E. (2012) · Skeletal Radiology · doi:10.1007/s00256-012-1511-5 · Cited by 49
Anwar, A. M., Soliman, O. I. I., Nemes, A., Germans, T., Krenning, B. J., Geleijnse, M. L., van Rossum, A. C., & ten Cate, F. J. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.01.026 · Cited by 49
Jobson, S., Nevill, A. M., George, S. R., Jeukendrup, A. E., & Passfield, L. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802183585 · Cited by 49
Kemps, H. M. C., De Vries, W. R., Hoogeveen, A. R., Zonderland, M. L., Thijssen, E. J. M., & Schep, G. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0398-7 · Cited by 54
Veer, M. V. ’., Geven, M., Rutten, M. C. M., van der Horst, A., Aarnoudse, W., Pijls, N. H. J., & van de Vosse, F. N. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.01.006 · Cited by 53
Park, Y. H., Ku, J. H., & Oh, S. (2010) · Neurourology and Urodynamics · doi:10.1002/nau.20977 · Cited by 49
Variability across the optic nerve head in scanning laser tomography
Tan, J. C. H., Garway-Heath, D. F., & Hitchings, R. A. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.5.557 · Cited by 50
van der Veldt, A. A. M., Hendrikse, N. H., Harms, H. J., Comans, E. F. I., Postmus, P. E., Smit, E. F., Lammertsma, A. A., & Lubberink, M. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079137 · Cited by 49
Strain during gastric contractions can be measured using Doppler ultrasonography
Gilja, O. H., Heimdal, A., Hausken, T., Gregersen, H. N., Matre, K., Berstad, A., & Ødegaard, S. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00614-2 · Cited by 54
Moinpour, C. M., Lyons, B., Schmidt, S., Chansky, K., & Patchell, R. A. (2000) · Quality of Life Research · doi:10.1023/a:1008978512572 · Cited by 56
Miller, D. R., Rogers, W. H., Kazis, L. E., Spiro, A., Ren, X. S., & Haffer, S. C. (2008) · Journal of Ambulatory Care Management · doi:10.1097/01.jac.0000314707.88160.9c · Cited by 54
Cosmi, B., Palareti, G., Moia, M., Carpenedo, M., Pengo, V., Biasiolo, A., Rampazzo, P., Morstabilini, G., & Testa, S. (2000) · Thrombosis Research · doi:10.1016/s0049-3848(00)00323-6 · Cited by 49
Åstrand, H., Sandgren, T., Ahlgren, Å. R., & Länne, T. (2003) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(02)75344-5 · Cited by 49
Lesho, E. P., & Roth, B. J. (1997) · CHEST Journal · doi:10.1378/chest.112.5.1291 · Cited by 49
Compliance of abdominal aortic aneurysms: Evaluation of tissue Doppler imaging
Long, A., Rouet, L., Bissery, A., Rossignol, P., Mouradian, D., & Sapoval, M. R. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.08.007 · Cited by 49
Efficiently estimated histologic cell counts
Going, J. J. (1994) · Human Pathology · doi:10.1016/0046-8177(94)90139-2 · Cited by 49
Comparative Overview of Cardiac Output Measurement Methods: Has Impedance Cardiography Come of Age?
DeMaria, A. N., & Raisinghani, A. (2000) · Congestive Heart Failure · doi:10.1111/j.1527-5299.2000.80139.x · Cited by 49
Marshall, I., Simonotto, E., Deary, I. J., MacLullich, A. M. J., Ebmeier, K. P., Rose, E. J., Wardlaw, J. M., Goddard, N., & Chappell, F. M. (2004) · Radiology · doi:10.1148/radiol.2333031782 · Cited by 49
Delhaye, D., Rémy‐Jardin, M., Teisseire, A., Hossein-Foucher, C., Leroy, S., Duhamel, A., & Rémy, J. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.1193 · Cited by 49
Finlay, I. G., Stott, N. C. H., & Kinnersky, P. (1995) · Medical Education · doi:10.1111/j.1365-2923.1995.tb02866.x · Cited by 49
Echocardiographic evidence of left ventricular hypertrophy in a general aged population
Lindroos, M., Kupari, M. M., Heikkilä, J., & Tilvis, R. S. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90408-1 · Cited by 49
Automated morphometry of coronary arteries with digital image analysis of intravascular ultrasound
Meier, D., Cothren, R. M., Vince, D. G., & Cornhill, J. F. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70170-4 · Cited by 49
Longitudinal assessment of amniotic fluid index
Nwosu, E. C., Welch, C. R., Manasse, P., & Walkinshaw, S. (1993) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1993.tb14305.x · Cited by 49
In vitro evaluation of three-dimensional ultrasonography based on magnetic scanhead tracking
Gilja, O. H., Hausken, T., Ólafsson, S., Matre, K., & Ødegaard, S. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00098-2 · Cited by 49
Bentsen-Farmen, R. K., Botnen, I. V., Notø, H., Jacob, J., & Øvrebø, S. (1999) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200050355 · Cited by 51
Furber, A., Balzer, P., Cavaro‐Ménard, C., Croué, A., Costa, E. D., Lethimonnier, F., Geslin, P., Tadéi, A., JALLET, P., & Jeune, J. L. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080503 · Cited by 52
Importance of measuring CO2-production rate when using 13C-breath tests to measure fat digestion
Amarri, S., Coward, W. A., Harding, M., & Weaver, L. T. (1998) · British Journal of Nutrition · doi:10.1079/bjn19980093 · Cited by 52
van Marken Lichtenbelt, W. D. (1997) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.82.3.907 · Cited by 50
Acar, P., Maunoury, C., Antonietti, T., Bonnet, D., Sidi, D., & Kachaner, J. (1998) · European Heart Journal · doi:10.1053/euhj.1998.1091 · Cited by 49
Dauzat, M., & Pomier–Layrargues, G. (1989) · Gastroenterology · doi:10.1016/0016-5085(89)90921-9 · Cited by 49
COMPARISON OF 3 INVESTIGATIONAL ASSAYS FOR THE FREE FORM OF PROSTATE SPECIFIC ANTIGEN
Nixon, R. G., MEYER, G. E., Blase, A. B., GOLD, M. H., & Brawer, M. K. (1998) · The Journal of Urology · doi:10.1016/s0022-5347(01)62913-6 · Cited by 49
Quantitative angiography after directional coronary atherectomy.
Serruys, P. W. J. C., Umans, V. A. W. M., Strauss, B. H., van Suylen, R. J., van den Brand, M., Suryapranata, H., de Feyter, P. J., & Roelandt, J. R. T. C. (1991) · Heart · doi:10.1136/hrt.66.2.122 · Cited by 49
Chou, T. M., Sudhir, K., Iwanaga, S., Chatterjee, K., & Yock, P. G. (1994) · American Heart Journal · doi:10.1016/0002-8703(94)90474-x · Cited by 49
Venkatesh, B., Clutton-Brock, T. H., & Hendry, S. P. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80096-5 · Cited by 49
Quantitative assessment of aortic stenosis by three-dimensional echocardiography
Menzel, T., Mohr-Kahaly, S., Kölsch, B., Kupferwasser, I., Kopp, H., Spiecker, M., Wagner, S., Meinert, R., Pagnia, F., & Meyer, J. (1997) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(97)70057-9 · Cited by 49
Low plasma iron status and akathisia.
Barton, A. L., Bowie, J., & Ebmeier, K. P. (1990) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.53.8.671 · Cited by 49
Rovaris, M., Inglese, M., van Schijndel, R. A., Sormani, M. P., Rodegher, M., Comi, G., & Filippi, M. (2000) · Journal of Neurology · doi:10.1007/s004150070054 · Cited by 49
Accuracy of Ultrasound in a Screening Programme for Abdominal Aortic Aneurysms
Thomas, P. R. S., Shaw, J. C., Ashton, H. A., Kay, D., & Scott, R. A. P. (1994) · Journal of Medical Screening · doi:10.1177/096914139400100103 · Cited by 49
Tsujino, H., Jones, M., Shiota, T., Qin, J. X., Greenberg, N. L., Cardon, L. A., Morehead, A. J., Zetts, A. D., Travaglini, A., Bauer, F., et al. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00270-2 · Cited by 49
Silva, A. T., Appelmelk, B. J., Buurman, W. A., Bayston, K. F., & Cohen, J. (1990) · The Journal of Infectious Diseases · doi:10.1093/infdis/162.2.454 · Cited by 49
Clinical evaluation of routine urodynamic investigations in prostatism
Jensen, K. M. (1989) · Neurourology and Urodynamics · doi:10.1002/nau.1930080603 · Cited by 49
Dating the Iron Age I/II transition in Israel: first intercomparison results
Boaretto, E., Jull, A. J. T., Gilboa, A., & Sharon, I. (2005) · Radiocarbon · doi:10.1017/s0033822200052188 · Cited by 49
Fakhrawi, D. H., Beeson, L., Libanati, C., Feleke, D., Kim, H., Quansah, A., Darnell, A., Lammi-Keefe, C. J., & Cordero-MacIntyre, Z. (2009) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2009.01.004 · Cited by 48
Szulc, P., Claustrat, B., Munoz, F., Marchand, F., & Delmas, P. D. (2004) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2004.02117.x · Cited by 48
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.