STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 17,101–17,200 of 47,868
Extraction vs nonextraction: arch widths and smile esthetics.
Kim, E., & Gianelly, A. A. (2003) · PubMed · doi:10.1043/0003-3219(2003)073<0354:evnawa>2.0.co;2 · Cited by 112
Transport and Temperature Effects on Measurement of Serum and Plasma Potassium
Seamark, D., Backhouse, S., Barber, P., Hichens, J., Salzmann, M. B., & Powell, R. J. (1999) · Journal of the Royal Society of Medicine · doi:10.1177/014107689909200703 · Cited by 28
An evaluation of the Bausch & Lomb Zywave aberrometer
Dobos, M. J., Twa, M. D., & Bullimore, M. A. (2009) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2009.00360.x · Cited by 28
Hanlon, C., Medhin, G., Alem, A., Araya, M., Abdulahi, A., Tesfaye, M., Wondimagegn, D., Taha, H., Anbesse, B., Baheretibeb, Y., et al. (2008) · Social Psychiatry and Psychiatric Epidemiology · doi:10.1007/s00127-008-0342-0 · Cited by 30
Determinants of Patient-Family Caregiver Congruence on Preferred Place of Death in Taiwan
Tang, S. T., Chen, C., Tang, W., & Liu, T. (2010) · Journal of Pain and Symptom Management · doi:10.1016/j.jpainsymman.2009.12.018 · Cited by 28
Dijkers, M. P. J. M., & Yavuzer, G. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90261-7 · Cited by 29
Kazmierczak, S. C., ROBERTSON, A. F., Briley, K. P., Kreamer, B. L., & Gourley, G. R. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.027326 · Cited by 28
Verelst, M., & Leivseth, G. (2004) · Neurourology and Urodynamics · doi:10.1002/nau.20070 · Cited by 35
Comparison of central venous and inferior vena caval pressures
Walsh, J. T., Hildick‐Smith, D., NEWELL, S. A., LOWE, M. D., Satchithananda, D. K., & Shapiro, L. M. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00787-0 · Cited by 28
Mascherbauer, J., Fuchs, C., Stoiber, M., Schima, H., Pernicka, E., Maurer, G., & Baumgartner, H. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn209 · Cited by 28
Gunkel, C. I., Valverde, A., Morey, T. E., Hernandez, J. M., & Robertson, S. A. (2004) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/j.1534-6935.2004.04017.x · Cited by 28
Assessment of the Accuracy of Indirect Blood Pressure Measurements.
Ochiai, H., 宮崎, 直., MIYATA, T., Mitake, A., Tochikubo, O., & Ishii, M. (1997) · Japanese Heart Journal · doi:10.1536/ihj.38.393 · Cited by 28
Dual‐energy X‐ray absorptiometry is the method of choice to assess body composition in COPD
Miller, A., Strauss, B. J., Mol, S. J. M., Kyoong, A., Holmes, P. W., Finlay, P. N., Bardin, P. G., & Guy, P. (2009) · Respirology · doi:10.1111/j.1440-1843.2009.01499.x · Cited by 34
Fontseré, N., Bonal, J., Navarro, M., Riba, J., Fraile, M., Torres, F., & Romero, R. (2006) · Nephron Clinical Practice · doi:10.1159/000095476 · Cited by 28
Lauridsen, H. H., Manniche, C., Korsholm, L., Grunnet-Nilsson, N., & Hartvigsen, J. (2009) · European Spine Journal · doi:10.1007/s00586-009-1070-1 · Cited by 32
Mendu, D. R., & Soldin, S. J. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.11.008 · Cited by 28
Competitive enzyme immunoassay for urinary vanillylmandelic acid
Taran, F., Bernard, H., Valleix, A., Créminon, C., Grassi, J., Olichon, D., Deverre, J.-R., & Pradelles, P. (1997) · Clinica Chimica Acta · doi:10.1016/s0009-8981(97)00092-2 · Cited by 32
Bolca, O., Akdemir, O., Eren, M., Dağdeviren, B., Yildirim, A., & Tezel, T. (2002) · Japanese Heart Journal · doi:10.1536/jhj.43.241 · Cited by 28
Noninvasive, Automated and Continuous Cardiac Output Monitoring by Pulmonary Capnodynamics
Peyton, P. J., Venkatesan, Y., Hood, S. G., Junor, P., & May, C. N. (2006) · Anesthesiology · doi:10.1097/00000542-200607000-00015 · Cited by 28
Fetal cardiac contractility before and after intrauterine transfusion
Sikkel, E., Klumper, F. J. C. M., Oepkes, D., Teunissen, A. K. K., Meerman, R. H., le Cessie, S., Kanhai, H. H. H., & Vandenbussche, F. P. H. A. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1996 · Cited by 28
Hummler, H., Engelmann, A., Pohlandt, F., Högel, J., & Franz, A. R. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2116-1 · Cited by 28
Shih, A., Giguère, S., Sanchez, L. C., Valverde, A., Bandt, C., Jankunas, H., & Robertson, S. A. (2009) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/j.1476-4431.2009.00461.x · Cited by 28
Validity and Repeatability of a New Test for Aniseikonia
Antona, B., Barra, F., Barrio, A. R., González-Romero, E., & Portero‐Sanchez, I. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0575 · Cited by 28
A Method for Simulation of Foveal Vision During Wear of Corrective Lenses
Legras, R., Château, N., & Charman, W. N. (2004) · Optometry and Vision Science · doi:10.1097/01.opx.0000144752.18836.1b · Cited by 28
Measurement of right ventricular volume in healthy term and preterm neonates
Clark, S. J., Yoxall, C. W., & Subhedar, N. V. (2002) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.87.2.f89 · Cited by 28
Smoothing Lung Segmentation Surfaces in Three-dimensional X-ray CT Images Using Anatomic Guidance1
Ukil, S., & Reinhardt, J. M. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.08.008 · Cited by 28
Kilding, A. E., Challis, N., Winter, E., & Fysh, M. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1232-0 · Cited by 35
Alber, B., Hein, R., Garbe, C., Caroli, U. M., & Luppa, P. B. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.097 · Cited by 28
An Improved Fluorophotometric Method for Tear Turnover Assessment
Pearce, E. I., KEENAN, B. P., & MCRORY, A. C. (2001) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2001.tb01200.x · Cited by 28
Holgado, R., Haire, H. M., Ross, D. L., Sprague, S. M., Pahl, M. V., Jara, A., Martín‐Malo, A., Rodríguez, M., Almadén, Y., & Felsenfeld, A. J. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.5.927 · Cited by 28
Bangla translation, adaptation and piloting of Edinburgh Postnatal Depression Scale
Gausia, K., Hamadani, J. D., Islam, M. M., Ali, M., Algin, S., Yunus, M., Fisher, C. M., & Oosthuizen, J. (2008) · Bangladesh Medical Research Council Bulletin · doi:10.3329/bmrcb.v33i3.1138 · Cited by 30
Effect of prolonged dissociation on the subjective measurement of near heterophoria
Rosenfield, M., Chun, T. W., & Fischer, S. E. (1997) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(97)00041-0 · Cited by 28
Villalta, D., Orunesu, E., Tozzoli, R., Montagna, P., Pesce, G., Bizzaro, N., & Bagnasco, M. (2004) · Journal of Clinical Pathology · doi:10.1136/jcp.2003.012294 · Cited by 30
Body composition of patients with Alzheimer's disease
Renvall, M. J., Spindler, A. A., Nichols, J. F., & Ramsdell, J. (1993) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(93)92130-p · Cited by 28
Stevenson, K. T., & van Tets, I. G. (2008) · Physiological and Biochemical Zoology · doi:10.1086/587096 · Cited by 32
Kaczmarek, I., Bigdeli, A. K., Vogeser, M., Mueller, T., Beiras-Fernández, A., Kaczmarek, P., Schmoeckel, M., Meiser, B., Reichart, B., & Ueberfuhr, P. (2008) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31817d7064 · Cited by 28
Ling, L. H., Tei, C., McCully, R. B., Bailey, K. R., Seward, J. B., & Pellikka, P. A. (2001) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2001.117339 · Cited by 28
Pérez, A. C., Eulmesekian, P. G., Minces, P., & Schnitzler, E. J. (2009) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e318193699d · Cited by 29
Effect of triploidy on turbot haematology
Cal, R. M., Vidal, S., Camacho, T., Piferrer, F., & Guitián, J. (2005) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/j.cbpb.2005.03.007 · Cited by 28
A Nonmotorized Treadmill Test to Assess Children’s Short-Term Power Output
Sutton, N. C., Childs, D. J., Bar‐Or, O., & Armstrong, N. (2000) · Pediatric Exercise Science · doi:10.1123/pes.12.1.91 · Cited by 28
Fleet, J. L., Shariff, S. Z., Bailey, D. G., Gandhi, S., Juurlink, D. N., Nash, D. M., Mamdani, M., Gomes, T., Patel, A. M., & Garg, A. X. (2013) · BMJ Open · doi:10.1136/bmjopen-2013-002857 · Cited by 28
Volmer, M., de Vries, J. C. M., & Goldschmidt, H. M. J. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.7.1287 · Cited by 28
Rapid measurement of aortic wave velocity: In vivo evaluation
Kraft, K. A., Itskovich, V. V., & Fei, D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1164 · Cited by 29
Development and Validation of the Self-Administration of Medication Tool
Manias, E., Beanland, C., Riley, R., & Hutchinson, A. M. (2006) · Annals of Pharmacotherapy · doi:10.1345/aph.1g677 · Cited by 30
van de Pol, A. C., Wolfs, T. F. W., van Loon, A. M., Tacke, C. E. A., Viveen, M. C., Jansen, N. J. G., Kimpen, J. L. L., Rossen, J. W. A., & Coenjaerts, F. E. J. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.00097-10 · Cited by 28
Sjøgaard, G., Hansen, E. A., & Osada, T. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00259.2002 · Cited by 30
Hill, M., Bradley, A., Mushtaq, S., Williams, E. A., & Powers, H. J. (2008) · British Journal Of Nutrition · doi:10.1017/s0007114508162997 · Cited by 29
Sievers, B., Addo, M., Kirchberg, S., Bakan, A., John-Puthenveettil, B., Franken, U., & Trappe, H. (2005) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200053515 · Cited by 32
Provider Support of Spontaneous Pushing During the Second Stage of Labor
Sampselle, C. M., Miller, J. M., Luecha, Y., Fischer, K., & Rosten, L. (2005) · Journal of Obstetric, Gynecologic & Neonatal Nursing · doi:10.1177/0884217505281904 · Cited by 28
Smith, L. S. (2003) · BMC Nursing · doi:10.1186/1472-6955-2-1 · Cited by 28
Torkian, B. A., Guo, S., Jahng, A. W., Liaw, L. L., Chen, Z., & Wong, B. J. F. (2006) · Otolaryngology · doi:10.1016/j.otohns.2005.09.016 · Cited by 28
Intraexaminer Reliability of Identifying a Dysfunctional Segment in the Thoracic and Lumbar Spine
Potter, L., McCarthy, C. J., & Oldham, J. A. (2006) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2006.01.005 · Cited by 28
Measurement of lung volume and optimal oxygenation during high frequency oscillation.
Dimitriou, G., & Greenough, A. (1995) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.72.3.f180 · Cited by 28
Assessment of ulnar variance: a radiological investigation in a Dutch population
Schuurman, A. H., Maas, M. M., Dijkstra, P. F., & Kauer, J. M. G. (2001) · Skeletal Radiology · doi:10.1007/s002560100414 · Cited by 28
Accuracy of Ultrasound Measurements for Skull Bone Thickness Using Coded Signals
Tretbar, S. H., Plinkert, P. K., & Federspil, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2011058 · Cited by 28
Nasal nitric oxide measurements before and after repeated humming maneuvers
Maniscalco, M., Sofia, M., Weitzberg, E., Carratù, L., & Lundberg, J. O. (2003) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.2003.01277.x · Cited by 31
Non-invasive measurement of cardiac output during coronary artery bypass grafting
Cohen, A. J., Arnaudov, D., Zabeeda, D., Schultheis, L. W., Lashinger, J., & Schachner, A. (1998) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(98)00135-3 · Cited by 28
Tisi, D. K., Emard, J. J., & Koski, K. G. (2004) · Journal of Nutrition · doi:10.1093/jn/134.7.1754 · Cited by 28
Grønholdt, M.-L. M., Wagner, A., Wiebe, B. M., Hansen, J. U., Schroeder, T. V., Wilhjelm, J. E., Nowak, M., & Sillesen, H. H. (2001) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2001.20.5.451 · Cited by 32
Carter, B., Hochmann, M., Osborne, A., Nisbet, A., & Campbell, N. (1995) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9502300610 · Cited by 28
Approach to maintaining comparability of biochemical data during long-term clinical trials
Cull, C. A., Manley, S. E., Stratton, I. M., Neil, H. A. W., Ross, I. S., Holman, R. R., Turner, R. C., & Matthews, D. R. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.10.1913 · Cited by 29
An Evaluation of the Reliability of Widmark Calculations Based on Breath Alcohol Measurements
Friel, P. N., Logan, B. K., & Baer, J. (1995) · Journal of Forensic Sciences · doi:10.1520/jfs13767j · Cited by 28
Detecting lung overdistention in newborns treated with high-frequency oscillatory ventilation
Weber, K. R., Courtney, S. E., Pyon, K. H., Chang, G. Y., Pandit, P. B., & Habib, R. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.1.364 · Cited by 28
Bremer, F., Schiele, A., & Tschaikowsky, K. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1252-3 · Cited by 28
Left anterior descending coronary artery flow and its relation to age in children
Yasuoka, K., Harada, K., Tamura, M., & Takada, G. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.115537 · Cited by 29
Measured versus predicted energy expenditure in children with inactive Crohn's disease
Hart, J. A. L., Bremner, A. R., Wootton, S. A., & Beattie, R. M. (2005) · Clinical Nutrition · doi:10.1016/j.clnu.2005.08.007 · Cited by 29
How should airways resistance be measured in young children: mask or mouthpiece?
Child, F., Clayton, S., Davies, S., Fryer, A. A., Jones, P. W., & Lenney, W. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.00089501 · Cited by 28
Left Ventricular Tei Index: Comparison between Flow and Tissue Doppler Analyses
Voon, W., Su, H., Yen, H., Lin, T., Lai, W., & Sheu, S. (2005) · Echocardiography · doi:10.1111/j.1540-8175.2005.00126.x · Cited by 28
Satisfaction profile (SAT-P) in 732 patients: Focus on subjectivity in hrqol assessment
Majani, G., Pierobon, A., Giardini, A., & Callegari, S. (2000) · Psychology & Health · doi:10.1080/08870440008402002 · Cited by 27
Soma, J., Widerøe, T., Dahl, K. J., Rossvoll, O., & Skjærpe, T. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00129-5 · Cited by 28
Comparison of repeatability of the multifocal electroretinogram and Humphrey perimeter
Parks, S., Keating, D., Evans, A. L., Williamson, T. H., Jay, J. L., & Elliott, A. T. (1996) · Documenta Ophthalmologica · doi:10.1007/bf02584082 · Cited by 28
Mori, Y., Rusk, R. A., Irvine, T., Sahn, D. J., Jones, M., Zetts, A. D., & Li, X. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02074-0 · Cited by 28
Schuster, D. P., Markham, J., & Welch, M. J. (1998) · Critical Care Medicine · doi:10.1097/00003246-199803000-00026 · Cited by 28
Songür, N., Fujimura, M., & Kamio, Y. (2000) · Respirology · doi:10.1046/j.1440-1843.2000.00273.x · Cited by 28
Accuracy and reproducibility of long-term implanted transit-time ultrasound flow probes in dogs
Picker, O., Schindler, A., & Scheeren, T. (2000) · Intensive Care Medicine · doi:10.1007/s001340051210 · Cited by 28
Adamson, A., Foster, E., Butler, T. J., Bennet, S., & Walker, M. (2001) · Diabetic Medicine · doi:10.1046/j.1464-5491.2001.00575.x · Cited by 28
Séror, O., Lepetit‐Coiffé, M., Quesson, B., Trillaud, H., & MOONEN, C. T. W. (2006) · European Radiology · doi:10.1007/s00330-006-0210-9 · Cited by 28
Enamel demineralisation assessed by computerised image analysis of clinical photographs
Benson, P. E., Pender, N., & Higham, S. M. (2000) · Journal of Dentistry · doi:10.1016/s0300-5712(00)00002-6 · Cited by 28
Chen, L., Ma, L., Prada, V. A. D., Chen, M., Feng, Y., Waters, D. D., Gillam, L. D., & Chen, C. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00384-1 · Cited by 28
Oral corticosteroid trials in the management of stable chronic obstructive pulmonary disease
Davies, L. (1999) · QJM · doi:10.1093/qjmed/92.7.395 · Cited by 28
Hausken, T., Leotta, D. F., Helton, S. W., Kowdley, K. V., Goldman, B. H., Vaezy, S., Bolson, E. L., Sheehan, F. H., & Martin, R. W. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00120-3 · Cited by 28
Virolainen, J. (1992) · Clinical Physiology · doi:10.1111/j.1475-097x.1992.tb00365.x · Cited by 29
Comparison between measured and predicted resting metabolic rate in moderately active adolescents
LORENZO, A. D., Bertini, I., Puijia, A., Testolin, G., & Testolin, C. (1999) · Acta Diabetologica · doi:10.1007/s005920050157 · Cited by 32
Greil, G. F., Germann, S., Kozerke, S., Baltes, C., Tsao, J., Urschitz, M. S., Seeger, A., Tangcharoen, T., Bialkowski, A., Miller, S., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21200 · Cited by 28
Proteomic approach to the diagnosis of acute coronary syndrome: Preliminary results
Serio, F. D., Amodio, G., Ruggieri, E., Sario, R. D., Varraso, L., Antonelli, G., & Pansini, N. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.03.031 · Cited by 28
Clarke, G. D., Hundley, W. G., McColl, R. W., Eckels, R., Smith, D., Li, H., & Peshock, R. M. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060506 · Cited by 28
Lane, J. T., Mack-Shipman, L. R., Anderson, J. C., Moore, T. E., Erickson, J. M., Ford, T. C., Stoner, J. A., & Larsen, J. L. (2005) · Endocrine · doi:10.1385/endo:27:3:295 · Cited by 31
Barnas, U., Schmidt, A., Seidl, G., Kaider, A., Pietschmann, P., & Mayer, G. J. (2001) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2001.24529 · Cited by 28
Methodological issues related to exhaled nitric oxide measurement in children aged four to six years
Napier, E., & Turner, S. W. (2005) · Pediatric Pulmonology · doi:10.1002/ppul.20249 · Cited by 28
Allometry of Anaerobic Performance: A Gender Comparison
Batterham, A. M., & Birch, K. M. (1996) · Canadian Journal of Applied Physiology · doi:10.1139/h96-005 · Cited by 29
Taal, E. (2003) · British journal of rheumatology · doi:10.1093/rheumatology/keg133 · Cited by 28
Comparing Laboratory Tests Using the Difference Plot Method
Jensen, A. L., & Bantz, M. (1993) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.1993.tb00604.x · Cited by 28
Acar, P., Roux, D., Dulac, Y., Rougé, P., & Aggoun, Y. (2003) · Cardiology in the Young · doi:10.1017/s1047951103000118 · Cited by 28
Wessels, T., Harrer, J. U., Stetter, S., Mull, M., & Klötzsch, C. (2004) · Stroke · doi:10.1161/01.str.0000133248.71808.38 · Cited by 28
Rio, F. G., Pino, J. M., Ruiz, A., Lobato, S. D., Prados, C., & Villamor, J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01010.2002 · Cited by 33
Comazzi, S., Gelain, M. E., Spagnolo, V., Riondato, F., Guglielmino, R., & Sartorelli, P. (2006) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2006.tb00088.x · Cited by 28
Stevens, W. S., Horsfield, P., & Scott, L. E. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.01540-06 · Cited by 28
Woltjera, H. H., Bogaard, H. J., Bronzwaer, J. G. F., de Cock, C. C., & VRIES, P. M. J. M. D. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70080-2 · Cited by 28
Madden, A. M., & Morgan, M. Y. (1994) · Journal of Hepatology · doi:10.1016/s0168-8278(94)80253-x · Cited by 29
Is Real-Time Ultrasonic Bladder Volume Estimation Reliable and Valid? A Systematic Overview
Chika R. Nwosu, K. S. K. (1998) · Scandinavian Journal of Urology and Nephrology · doi:10.1080/003655998750015278 · Cited by 28
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.