STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 17,201–17,300 of 47,868
Middle-latency auditory evoked potentials during induction of thiopentone anaesthesia in pigs
Martoft, L., Jensen, E. W., Rodriguez, B. E., Jørgensen, P. F., Forslid, A., & Pedersen, H. D. (2001) · Laboratory Animals · doi:10.1258/0023677011911958 · Cited by 28
Nirmalan, M., Niranjan, M., Willard, T., Edwards, J. D., Little, R., & Dark, P. M. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh232 · Cited by 28
Suppressed Anger Is Associated With Increased Carotid Arterial Stiffness in Older Adults
ANDERSON, D., Metter, E. J., Hougaku, H., & Najjar, S. S. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2006.04.018 · Cited by 31
Continuous arterial and venous blood gas monitoring during cardiopulmonary bypass
Mark, J. B., FitzGerald, D., Fenton, T., Fosberg, A. M., Camann, W., Maffeo, N., & Winkelman, J. W. (1991) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)36528-6 · Cited by 28
Robertson, G. S. M., Chadwick, D. R., Contractor, H. H., James, R. F. L., Bell, P. R. F., & London, N. J. M. (1993) · Acta Diabetologica · doi:10.1007/bf00572864 · Cited by 28
Béghin, L., Budniok, T., Vaksmann, G., Delbecque-Boussard, L., Michaud, L., Turck, D., & Gottrand, F. (2000) · Clinical Nutrition · doi:10.1054/clnu.2000.0147 · Cited by 31
Assessment of a new transtelephonic portable spirometer.
Abboud, S., & BRUDERMAN, I. (1996) · Thorax · doi:10.1136/thx.51.4.407 · Cited by 28
A dermal model for spray painters. Part I: Subjective exposure modelling of spray paint deposition
Brouwer, D. (2001) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(00)00006-5 · Cited by 28
Spot ferritin assay for serum samples dried on filter paper
Ahluwalia, N., Lönnerdal, B. L., Lorenz, S., & Allen, L. H. (1998) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/67.1.88 · Cited by 28
Kroke, A., Fleischhauer, W., Mieke, S., Klipstein‐Grobusch, K., Willich, S. N., & Boeing, H. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00004 · Cited by 28
Bouki, K. P., Lange, A., Palka, P., MORAN, C. M., Fenn, L. N., Wright, R. A., Fox, K. A. A., McDicken, W. N., & Sutherland, G. R. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014760 · Cited by 28
Baumert, B., Plass, A., Béttex, D., Alkadhi, H., Desbiolles, L. M., Wildermuth, S., Marinček, B., & Boehm, T. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000178363.79489.ef · Cited by 28
Aortic root replacement with a pulmonary autograft
Hokken, R. B., Bogers, A. J. J. C., Taams, M. A., Willems, T. P., Cromme-Dijkhuis, A. H., Witsenburg, M., Spitaels, S. E. C., VANHERWERDEN, L., & Bos, E. (1995) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(05)80170-8 · Cited by 28
Foster, G. P., Weissman, N. J., Picard, M. H., Fitzpatrick, P. J., Shubrooks, S. J., & ZARICH, S. W. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00462-9 · Cited by 28
Rittoo, D., Sutherland, G. R., & Shaw, T. R. D. (1993) · Circulation · doi:10.1161/01.cir.87.5.1591 · Cited by 28
Nutritional impact of antipseudomonas intravenous antibiotic courses in cystic fibrosis
Vic, P., Ategbo, S., Gottrand, F., Launay, V., Loeuille, G., Elian, J. C., Druon, D., Farriaux, J. P., & Turck, D. (1997) · Archives of Disease in Childhood · doi:10.1136/adc.76.5.437 · Cited by 30
Burling, D. N., Halligan, S., Taylor, S. A., Brennand, D., Altman, D. G., Bassett, P., Atkin, W. S., & Bartram, C. I. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0171 · Cited by 35
Self-citationAutomated ejection fraction determination from gated myocardial FDG-PET data
Willemsen, A. T. M., Siebelink, H. J., Blanksma, P. K., & Paans, A. M. J. (1999) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(99)90093-4 · Cited by 28
Jacobsen, S. J., Klee, G. G., Lilja, H. G., Wright, G. L., & Oesterling, J. E. (1995) · Urology · doi:10.1016/s0090-4295(99)80014-4 · Cited by 28
Escaned, J., Foley, D. P., Haase, J., Mario, C. D., Hermans, W. R. M., de Feyter, P. J., & Serruys, P. W. J. C. (1993) · American Heart Journal · doi:10.1016/0002-8703(93)90530-m · Cited by 28
Hassan, I. A., Spencer, S. A., Wickramasinghe, Y. A. B. D., & Palmer, K. (2000) · Early Human Development · doi:10.1016/s0378-3782(99)00076-6 · Cited by 28
Plein, S., Smith, W. H., Ridgway, J. P., Kassner, A., Beacock, D. J., Bloomer, T. N., & Sivananthan, M. U. (2001) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf02668158 · Cited by 31
Assessment of passive respiratory compliance in healthy preterm infants: A critical evaluation
Gappa, M., Rabbette, P. S., Costeloe, K., & Stocks, J. (1993) · Pediatric Pulmonology · doi:10.1002/ppul.1950150508 · Cited by 28
Desmet, W., Scheerder, I. D., Beatt, K. J., Huehns, T. Y., & Piessens, J. (1995) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810340319 · Cited by 28
OXYGEN DESATURATION FOLLOWING SEDATION FOR REGIONAL ANALGESIA
Smith, D., & Crul, J. F. (1989) · British Journal of Anaesthesia · doi:10.1093/bja/62.2.206 · Cited by 28
Comparative study of glass and antimony electrodes for continuous oesophageal pH monitoring.
Vandenplas, Y., Helven, R., & Goyvaerts, H. (1991) · Gut · doi:10.1136/gut.32.6.708 · Cited by 28
Barnard, M., Schwieso, J. E., Thomas, E. L., Bell, J. D., Saeed, N., Frost, G. S., Bloom, S. R., & Hajnal, J. V. (1996) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199606)9:4<141::aid-nbm403>3.0.co;2-p · Cited by 29
Crimi, N., Polosa, R., Magrì, S., Prosperini, G., Milazzo, V., Santonocito, G., & Mistretta, A. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08060905 · Cited by 28
Measurement of Myocardial Infarct Size By Electron Beam Computed Tomography
Schmermund, A., Gerber, T. C., Behrenbeck, T. R., Reed, J. E., Sheedy, P. F., Christian, T. F., & Rumberger, J. A. (1998) · Investigative Radiology · doi:10.1097/00004424-199806000-00001 · Cited by 28
Albrecht, C., Reichen, J., Visser, J., Meijer, D. K. F., & Thormann, W. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.11.2083 · Cited by 28
In Vivo Measurements of Ethanol Concentration in Rabbit Brain by 1H Magnetic Resonance Spectroscopy
Petroff, O. A. C., Novotny, E. J., Ogino, T., Avison, M. J., & Prichard, J. W. (1990) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1990.tb01947.x · Cited by 28
Point‐of‐Care Testing: Principles, Practice, and Critical‐Emergency‐Disaster Medicine
Kost, G. J., Tran, N. K., & Louie, R. F. (2008) · Wiley eBooks · doi:10.1002/9780470027318.a0540.pub2 · Cited by 38
Thomas, J. D., Chandra, S., Karson, T. H., Pu, M., & Vandervoort, P. M. (1996) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(96)90055-3 · Cited by 28
Barry, B., Mallick, A., Hartiey, G., Bodenham, A. R., & Vucevic, M. (1998) · Intensive Care Medicine · doi:10.1007/s001340050665 · Cited by 30
Locating Facial Features with Active Shape Models
Milborrow, S. (2007) · Open University of Cape Town (University of Cape Town) · Cited by 28
Reproducibility and repeatability.
Slezak, P. P., & Waczulı́ková, I. (2011) · PubMed · Cited by 28
Multimodal chest surface motion data for respiratory and cardiovascular monitoring applications
Shafiq, G., & Veluvolu, K. C. (2017) · Scientific Data · doi:10.1038/sdata.2017.52 · Cited by 28
Dioum, A., Gartner, A., Cissé, A. S., Delpeuch, F., Maire, B., Wade, S., & Schutz, Y. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.3.597 · Cited by 27
Pilot Study of the EncephaLog Smartphone Application for Gait Analysis
Tchelet, K., Stark-Inbar, A., & Yekutieli, Z. (2019) · Sensors · doi:10.3390/s19235179 · Cited by 27
Moula, Z., Powell, J., Brocklehurst, S., & Karkou, V. (2022) · Frontiers in Psychology · doi:10.3389/fpsyg.2022.883334 · Cited by 39
Flora, S., Marques, A. S. P. D. D., Hipólito, N., Morais, N., Silva, C. G., Januário, F., Rodrigues, F., Carreira, B. P., & Cruz, J. (2022) · Respiratory Medicine · doi:10.1016/j.rmed.2022.107087 · Cited by 31
Tang, H., Munkasy, B. A., & Li, L. (2024) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2024.01.002 · Cited by 31
Chaumeil, A., Lahkar, B. K., Dumas, R., Muller, A., & Robert, T. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112018 · Cited by 27
Eghtesad, S., Masoudi, S., Sharafkhah, M., Rashidkhani, B., Nadimi, A. E., Najafi, F., Faramarzi, E., Homayounfar, R., Ebrahimnejad, P., Ansari‐Moghaddam, A., et al. (2024) · Nutrition Journal · doi:10.1186/s12937-024-00938-0 · Cited by 29
High‐frequency ultrasound accuracy in preoperative cutaneous melanoma assessment: A meta‐analysis
Sellyn, G. E., Lopez, A. A., Ghosh, S., Topf, M. C., Chen, H., Tkaczyk, E. R., & Powers, J. G. (2024) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.20179 · Cited by 28
Passively sensing smartphone use in teens with rates of use by sex and across operating systems
Alexander, J. D., Linkersdörfer, J., Toda-Thorne, K., Sullivan, R. M., Cummins, K. M., Tomko, R. L., Allen, N. B., Bagot, K. S., Baker, F. C., Fuemmeler, B. F., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-68467-8 · Cited by 32
Predicting resting energy expenditure in young adults
Willis, E. A., Herrmann, S. D., Ptomey, L. T., Honas, J. J., Bessmer, C. T., Donnelly, J. E., & Washburn, R. A. (2015) · Obesity Research & Clinical Practice · doi:10.1016/j.orcp.2015.07.002 · Cited by 28
Geitzenauer, W., Kiss, C., Durbin, M. K., ABUNTO, M. T. A., CALLAN, T. M., STETSON, P. F., WIELAND, M. R., BRESSLER, N. M., GREGORI, G., & Schmidt-Erfurth, U. M. (2010) · Retina · doi:10.1097/iae.0b013e3181c10711 · Cited by 27
Langton, C. M., & Wille, M. (2013) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411913486079 · Cited by 27
Koppelman, M., van Swieten, P., & Cuijpers, H. T. M. (2010) · Transfusion · doi:10.1111/j.1537-2995.2010.02995.x · Cited by 27
B1 mapping with selective pulses
Bouhrara, M., & Bonny, J.-M. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24146 · Cited by 27
Galjaard, S., Baeck, S., Ameye, L., Bourne, T., Timmerman, D., & Devlieger, R. (2013) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.13285 · Cited by 27
Jakubovic, B. D., Wald, R., Goldstein, M. B., Leong-Poi, H. M., Yuen, D. A., Perl, J. M., Lima, J. A. C., Liu, J. J., Kirpalani, A., Dacouris, N., et al. (2012) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2012.07.013 · Cited by 29
van der Linde, D., Rossi, A., Yap, S., McGhie, J. S., van den Bosch, A. E., Kirschbaum, S. W., Russo, B., van Dijk, A. P. J., Moelker, A. D., Krestin, G. P., et al. (2013) · Echocardiography · doi:10.1111/echo.12086 · Cited by 27
Bjerre, M., Hansen, T. K., Flyvbjerg, A., & Tønnesen, E. (2009) · Veterinary Immunology and Immunopathology · doi:10.1016/j.vetimm.2009.01.007 · Cited by 27
Nishimiya, K., Matsumoto, Y., Uzuka, H., Oyama, K., Tanaka, A., Taruya, A., Ogata, T., Hirano, M., Shindo, T., Hanawa, K., et al. (2015) · Circulation Journal · doi:10.1253/circj.cj-15-0078 · Cited by 27
Kato, D., Takashima, H., Waseda, K., Kurita, A., Kuroda, Y., Kosaka, T., Kuhara, Y., Ando, H., Maeda, K., Kumagai, S., et al. (2014) · Heart and Vessels · doi:10.1007/s00380-014-0508-5 · Cited by 27
Francescato, M. P., Geat, M., Stel, G., & Cauci, S. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.10.012 · Cited by 29
Monchi, M., Thébert, D., Cariou, A., Bellenfant, F., Joly, L., Brunet, F. P., & Dhainaut, J.-F. (1998) · Journal of Critical Care · doi:10.1016/s0883-9441(98)80007-5 · Cited by 27
Relative validity of a food frequency questionnaire to assess nutrient intake in pregnant women
McGowan, C. A., Curran, S., & McAuliffe, F. M. (2013) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12120 · Cited by 35
Kim, M., Park, S., Baek, I., & Chun, J. (2014) · Systematic and Applied Microbiology · doi:10.1016/j.syapm.2014.11.008 · Cited by 28
Ziai, S., Coriati, A., Chabot, K., Mailhot, M., Richter, M. V., & RABASA-LHORET, R. P. R. (2014) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2014.01.006 · Cited by 27
Stilling, M., Mechlenburg, I., Amstrup, A., Søballé, K., & Klebe, T. (2012) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-012-1580-x · Cited by 27
3D T 1-mapping for the characterization of deep vein thrombosis
Blume, U. A., Orbell, J., Waltham, M., Smith, A., Razavi, R., & Schaeffter, T. (2009) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-009-0189-8 · Cited by 27
Øverland, B., Bruskeland, G., Akre, H., & Skatvedt, O. (2005) · Respiration · doi:10.1159/000086722 · Cited by 29
Comparison of two nonverbal intelligence tests among children who are deaf or hard-of-hearing
Phillips, J. M., Wiley, S., Barnard, H. D., & Meinzen‐Derr, J. K. (2013) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2013.11.020 · Cited by 27
Fujii, N., Tsuji, B., Honda, Y., Kondo, N., & Nishiyasu, T. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01049.2014 · Cited by 31
Vähäsarja, V. J., Lanning, P., Lahde, S., & Serlo, W. S. (1996) · Clinical Radiology · doi:10.1016/s0009-9260(96)80059-6 · Cited by 33
Sherma, N. D., Borges, C. R., Trenchevska, O., Jarvis, J. W., Rehder, D. S., Oran, P. E., Nelson, R. W., & Nedelkov, D. (2014) · Proteome Science · doi:10.1186/s12953-014-0052-3 · Cited by 29
Mégarbane, B., Bloch, V., Hirt, D., Debray, M., Résière, D., Deye, N., & Baud, F. J. (2010) · Clinical Toxicology · doi:10.3109/15563650.2010.518969 · Cited by 27
Enders, M., Bartelt, U., Knotek, F., Bunn, K., Strobel, S., Dietz, K., & Enders, G. (2013) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00688-12 · Cited by 27
Validation of in vivo 2D displacements from spiral cine DENSE at 3T
Wehner, G. J., Suever, J. D., Haggerty, C. M., Jing, L., Powell, D. K., Hamlet, S. M., Grabau, J. D., Mojsejenko, D., Zhong, X., Epstein, F. H., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0119-z · Cited by 29
Woo, S., Cho, J. Y., Kim, S. H., & Kim, S. Y. (2013) · Acta Radiologica · doi:10.1177/0284185113513887 · Cited by 27
Velocity Acceleration as a Determinant of Flow-Mediated Dilation
Stoner, L. R., & McCully, K. K. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.12.024 · Cited by 29
Detection of body temperature with infrared thermography: accuracy in detection of fever.
Cheung, B. M. Y., Chan, L. S., Lauder, I., & Kumana, C. R. (2012) · PubMed · Cited by 27
Megahed, A., Hiew, M. W. H., Townsend, J. R., Messick, J. B., & Constable, P. D. (2015) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.13608 · Cited by 31
Electrocardiographic P-wave characteristics in patients with psoriasis vulgaris
Bacaksız, A., Erdoğan, E., Tasal, A., Vatankulu, M. A., Kul, Ş., Sevgili, E., Ertaş, G., Dizman, D., Onsun, N., & Uysal, Ö. (2012) · Upsala Journal of Medical Sciences · doi:10.3109/03009734.2012.744372 · Cited by 27
Wang, Q., Zhang, S., Guo, L., Busch, C. M., Jian, W., Weng, N., Snyder, N. W., Rangiah, K., Mesaros, C., & Blair, I. A. (2015) · Bioanalysis · doi:10.4155/bio.15.195 · Cited by 28
Zhang, L., Wahle, A., Chen, Z., Zhang, L., Downe, R., Kovárník, T., & Milan Sonka, A. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2444815 · Cited by 27
Spelten, O., Fiedler, F., Schier, R., Wetsch, W. A., & Hinkelbein, J. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9810-8 · Cited by 27
Irvine, K. L., Burt, K., Hill, A. J., Shaw, S., & Papasouliotis, K. (2016) · Veterinary Clinical Pathology · doi:10.1111/vcp.12326 · Cited by 27
Martens, A. L., Slottje, P., Meima, M. Y., Beekhuizen, J., Timmermans, D. R. M., Kromhout, H., Smid, T., & Vermeulen, R. C. H. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.01.194 · Cited by 27
van Helden, J., & Weiskirchen, R. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0698 · Cited by 28
Suárez-Mejías, C., Pérez‐Carrasco, J. A., Serrano, C., Guerra, J. L. L., Parra-Calderón, C. L., Gómez‐Cía, T., & Acha, B. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1505-x · Cited by 28
Sasaki, K., Mutoh, T., Mutoh, T., Kawashima, R., & Tsubone, H. (2016) · Veterinary Anaesthesia and Analgesia · doi:10.1111/vaa.12380 · Cited by 31
Validity and test–retest reliability of an at-work production loss instrument
Aboagye, E., Jensen, I. B., Bergström, G., Hagberg, J., Axén, I., & Lohela-Karlsson, M. (2016) · Occupational Medicine · doi:10.1093/occmed/kqw021 · Cited by 27
Kuetting, D. L. R., Dabir, D., Homsi, R., Sprinkart, A. M., Luetkens, J. A., Schild, H. H., & Thomas, D. K. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0249-y · Cited by 27
Validation of Optical Coherence Tomography–Based Crystalline Lens Thickness Measurements in Children
Lehman, B. M., Berntsen, D. A., Bailey, M. D., & Zadnik, K. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e318198198d · Cited by 27
Yuan, Q., da Costa, D. N., Sénégas, J., Xi, Y., Wiethoff, A. J., Rofsky, N. M., Roehrborn, C. G., Lenkinski, R. E., & Pedrosa, I. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25391 · Cited by 27
Lim, P., Chen, C. H., Zhu, F., Kotanko, P., Jeng, Y., Hu, C. Y., Chiu, L.-S., & Chang, H. (2016) · Journal of Renal Nutrition · doi:10.1053/j.jrn.2016.08.003 · Cited by 29
Ohno, Y., Fujisawa, Y., Koyama, H., Kishida, Y., Seki, S., Sugihara, N., & Yoshikawa, T. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.11.008 · Cited by 28
Köster, M., Dennhardt, S., Jüttner, F., & Hopf, H. (2016) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12840 · Cited by 31
Chest physiotherapy can affect the lung clearance index in cystic fibrosis patients
Große-Onnebrink, J., Mellies, U., Olivier, M., Werner, C., & Stehling, F. (2017) · Pediatric Pulmonology · doi:10.1002/ppul.23670 · Cited by 27
de Castro, J. A. C., de Lima, L. R. A., & Silva, D. A. S. (2017) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12501 · Cited by 31
Harari, Y., Riemer, R., & Bechar, A. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.09.003 · Cited by 27
Reliability of anthropometric measurements in children with special needs
Hardy, J., Kuter, H., Campbell, M., & Canoy, D. (2018) · Archives of Disease in Childhood · doi:10.1136/archdischild-2017-314243 · Cited by 31
Fancourt, H. S. M., & Stephan, C. N. (2018) · Forensic Science International · doi:10.1016/j.forsciint.2018.02.008 · Cited by 28
Alcántara, J. M. A., Sánchez‐Delgado, G., Martínez‐Téllez, B., Merchán-Ramírez, E., Labayen, I., & Ruiz, J. R. (2018) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2018.03.010 · Cited by 33
Muh, F., Lee, S., Hoque, M. R., Han, J., Park, J.-H., Firdaus, M. E. R., Moon, R. W., Lau, Y. L., & Han, E. (2018) · Malaria Journal · doi:10.1186/s12936-018-2420-4 · Cited by 31
Fernández-Rodríguez, L., Torres, I., Romera, D., Galera, R., Casitas, R., Martínez-Cerón, E., Díaz-Agero, P., Utrilla, C., & Rio, F. G. (2018) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2018.07.040 · Cited by 27
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.