STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 17,801–17,900 of 47,868
Drouin, O., Johnson, J.-A., Chaemsaithong, P., Metcalfe, A., Huber, J., Schwarzenberger, J., Winters, E., Stavness, L., Tse, W. T., Lu, J., et al. (2017) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.18917 · Cited by 27
Lie, M. U., Matre, D., Hansson, P. T., Stubhaug, A., Zwart, J., & Nilsen, K. B. (2017) · PAIN Reports · doi:10.1097/pr9.0000000000000626 · Cited by 33
Stroke severity quantification by critical care physicians in a mobile stroke unit
Hov, M. R., Røislien, J., Lindner, T. W., Zakariassen, E., Bache, K. C. G., Solyga, V. M., Russell, D., & Lund, C. G. (2017) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000000529 · Cited by 27
Kivle, K., Lindland, E. S., Mjaaland, K. E., Pripp, A. H., Svenningsen, S., & Nordsletten, L. (2018) · Clinical Radiology · doi:10.1016/j.crad.2018.02.014 · Cited by 27
Accuracy of 5 Point-of-Care Glucometers in C57BL/6J Mice.
Morley, L. A., Gomez, T. H., Goldman, J. L., Flores, R., & Robinson, M. A. (2018) · Europe PMC (PubMed Central) · Cited by 26
The validity of Running Anaerobic Sprint Test to assess anaerobic power in young soccer players
Hazır, T., Köse, M. G., & İŞLER, A. K. (2018) · Isokinetics and Exercise Science · doi:10.3233/ies-182117 · Cited by 29
Jia, Z., Zhang, C., Zou, Y., Huang, X., & Xu, W. (2018) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-018-2973-2 · Cited by 25
Intrapartum ultrasound assessment of cervical dilatation and its value in detecting active labor
Wiafe, Y. A., Whitehead, B., Venables, H. K., Dassah, E. T., & Eggebø, T. M. (2018) · Journal of Ultrasound · doi:10.1007/s40477-018-0309-2 · Cited by 26
Relationship between Rectal Temperature and Vaginal Temperature in Grazing Bos taurus Heifers
Lees, A. M., Lea, J. M., Salvin, H. E., Cafe, L. M., Colditz, I. G., & Lee, C. (2018) · Animals · doi:10.3390/ani8090156 · Cited by 34
Vectorcardiogram in athletes: The Sun Valley Ski Study
Thomas, J., Alday, E. A. P., Junell, A., Newton, K., Hamilton, C., Li‐Pershing, Y., German, D. M., Bender, A. B., & Tereshchenko, L. G. (2018) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12614 · Cited by 26
Interobserver Reliability of the Animal Welfare Indicators Welfare Assessment Protocol for Horses
Czycholl, I., Klingbeil, P., & Krieter, J. (2019) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2019.02.005 · Cited by 27
Interdevice agreement in respiratory resistance values by oscillometry in asthmatic children
Ducharme, F. M., Jroundi, I., Jean, G., Boutin, G. L., Lawson, C. C., & Vinet, B. (2019) · ERJ Open Research · doi:10.1183/23120541.00138-2018 · Cited by 26
Boisson, M., Poignard, M., Pontier, B., Mimoz, O., Debaene, B., & Frasca, D. (2019) · Anaesthesia · doi:10.1111/anae.14638 · Cited by 27
Arathy, R., Nabeel, P. M., Joseph, J., & Sivaprakasam, M. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab1a82 · Cited by 27
Pinprick Evoked Potentials—Reliable Acquisition in Healthy Human Volunteers
Rösner, J., Scheuren, P. S., Stalder, S. A., Curt, A. E. P., & Hubli, M. (2019) · Pain Medicine · doi:10.1093/pm/pnz126 · Cited by 27
Jordan, T. B., Meyers, C., Schrading, W. A., & Donnelly, J. P. (2019) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2019.07.020 · Cited by 26
Comparison of angle-to-angle distance using three devices in normal eyes
Saito, A., Kamiya, K., Fujimura, F., Takahashi, M., & Shoji, N. (2019) · Eye · doi:10.1038/s41433-019-0653-2 · Cited by 26
内野晴登, Yamamoto, S., Kashiwazaki, D., Akioka, N., Kuwayama, N., Noguchi, K., & Kuroda, S. (2019) · Journal of neurosurgery · doi:10.3171/2019.8.jns191846 · Cited by 26
Singh, G. K., Mowers, K. L., Marino, C. J., Balzer, D. T., & Rao, P. S. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.09.001 · Cited by 26
Greybe, D. G., Jones, C. M., Brown, M. R., & Williams, E. M. P. (2020) · Sports Engineering · doi:10.1007/s12283-020-00324-z · Cited by 27
Equivalency of Sleep Estimates: Comparison of Three Research-Grade Accelerometers
Plekhanova, T., Rowlands, A. V., Yates, T. E., Hall, A. P., Brady, E. M., Davies, M. J., Khunti, K., & Edwardson, C. L. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0047 · Cited by 28
Silvester, C. M., & Hillson, S. W. (2020) · American Journal of Physical Anthropology · doi:10.1002/ajpa.24109 · Cited by 26
Arafati, A., Morisawa, D., Avendi, M. R., Amini, M. R., Assadi, R. A., Jafarkhani, H., & Kheradvar, A. (2020) · Journal of The Royal Society Interface · doi:10.1098/rsif.2020.0267 · Cited by 32
Bamdad, S., Momeni‐Moghaddam, H., Abdolahian, M., & Pinero, D. P. (2020) · Journal of Optometry · doi:10.1016/j.optom.2020.08.008 · Cited by 26
Reliability of body composition assessment using A-mode ultrasound in a heterogeneous sample
Micloș-Balica, M., Muntean, P., Schick, F., Hărăguş, H. G., Glisici, B., Pupăzan, V., Neagu, A., & Neagu, M. (2020) · European Journal of Clinical Nutrition · doi:10.1038/s41430-020-00743-y · Cited by 30
A Quality Control System for Automated Prostate Segmentation on T2-Weighted MRI
Sunoqrot, M. R. S., Selnæs, K. M., Sandsmark, E., Nketiah, G. A., Zavala‐Romero, O., Stoyanova, R. S., Bathen, T. F., & Elschot, M. (2020) · Diagnostics · doi:10.3390/diagnostics10090714 · Cited by 29
Reliability of Load-Velocity Profiling in Front Crawl Swimming
Olstad, B. H., Gonjo, T., Njøs, N., Abächerli, K., & Eriksrud, O. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.574306 · Cited by 26
Brosch-Lenz, J., Gosewisch, A., Kaiser, L., Seidensticker, M., Ricke, J., Zellmer, J., Bartenstein, P., Ziegler, S. I., Ilhan, H., Todica, A. S., et al. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.11.016 · Cited by 26
Helminen, J., & Linnansaari, T. (2021) · Fisheries Research · doi:10.1016/j.fishres.2021.105883 · Cited by 26
Jabri, M. A., Wu, S., Pan, Y., & Wang, L. (2021) · Nigerian Journal of Clinical Practice · doi:10.4103/njcp.njcp_698_19 · Cited by 26
Bató, A., Brodszky, V., Gergely, L. H., Gáspár, K., Wikonkál, N. M., Kinyó, Á., Szabó, Á., Beretzky, Z., Szegedi, A., Remenyik, É., et al. (2021) · Quality of Life Research · doi:10.1007/s11136-020-02732-x · Cited by 26
Kim, T.-L., Kim, K. K., Choi, C., Lee, J.-Y., & Shin, J. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00835-1 · Cited by 26
Gonjo, T., Njøs, N., Eriksrud, O., & Olstad, B. H. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.625411 · Cited by 26
Müller, P. L., Liefers, B. J., Treis, T., Rodrigues, F. G., Olvera‐Barrios, A., Paul, B., Dhingra, N., Lotery, A. J., Bailey, C., Taylor, P. M., et al. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.3.4 · Cited by 26
Musical aesthetic sensitivity.
Clemente, A., Pearce, M. T., & Nadal, M. (2021) · Psychology of Aesthetics Creativity and the Arts · doi:10.1037/aca0000381 · Cited by 34
Zhu, J., Angelov, S. N., Yildirim, I. A., Hao, W., Hu, J. H., Majesky, M. W., Brozovich, F. V., Kim, F., & Dichek, D. A. (2021) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.121.315878 · Cited by 29
Custodero, C., Senesi, B., Pinna, A., Floris, A., Vigo, M., Fama, M., Mastropierro, V., Sabbà, C., Prete, C., & Pilotto, A. (2021) · Aging Clinical and Experimental Research · doi:10.1007/s40520-021-01871-6 · Cited by 32
Naderi, A. M., Bu, H., Su, J., Huang, M.-H., Vo, K., Torres, R. S. T., Chiao, J. ‐., Lee, J., Lau, M., Xu, X., et al. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104565 · Cited by 27
Measuring Spatiotemporal Parameters on Treadmill Walking Using Wearable Inertial System
Scataglini, S., Verwulgen, S., Roosens, E., Haelterman, R., & Tiggelen, D. V. (2021) · Sensors · doi:10.3390/s21134441 · Cited by 32
Bortsova, G., Bos, D., Dubost, F., Vernooij, M. W., Ikram, M. K., van Tulder, G., & de Bruijne, M. (2021) · Radiology Artificial Intelligence · doi:10.1148/ryai.2021200226 · Cited by 29
Howell, C. M., McCullough, S. J., Doyle, L. A., MURPHY, M. H., & Saunders, K. J. (2021) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12860 · Cited by 29
Accuracy and reliability of tooth widths and Bolton ratios measured by ClinCheck Pro
Shailendran, A., Weir, T., Freer, E., & Kerr, B. (2021) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2020.06.048 · Cited by 28
Sunoqrot, M. R. S., Selnæs, K. M., Sandsmark, E., Langørgen, S., Bertilsson, H., Bathen, T. F., & Elschot, M. (2021) · Diagnostics · doi:10.3390/diagnostics11091690 · Cited by 28
Pigliasco, F., Cafaro, A., Simeoli, R., Barco, S., Magnasco, A., Faraci, M., Tripodi, G., Goffredo, B. M., & Cangemi, G. (2021) · Biomedicines · doi:10.3390/biomedicines9101379 · Cited by 26
Armstrong, T., Zhong, X., Shih, S., Felker, E. R., Lu, D., Dale, B. M., & Wu, H. H. (2021) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2021.10.016 · Cited by 29
Velasco, C., da Cruz, G. J. L., Jaubert, O., Lavín, B., Botnar, R. M., & Prieto, C. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29089 · Cited by 26
Zhu, W., Benkwitz, F., Sarmadi, B., & Kilmartin, P. A. (2021) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.1c06411 · Cited by 26
Tanabe, N., Kaji, S., Shima, H., Shiraishi, Y., Maetani, T., Oguma, T., Satô, S., & Hirai, T. (2022) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2021.769557 · Cited by 26
Comparison between DXA and MRI for the Visceral Fat Assessment in Athletes
Murata, H., Yagi, T., Midorikawa, T., Torii, S., Takai, E., & Taguchi, M. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1717-1619 · Cited by 30
Lee, J., Ha, S., Kim, R. E. Y., Lee, M., Kim, D., & Lim, H. K. (2022) · Diagnostics · doi:10.3390/diagnostics12030623 · Cited by 28
Wilder, A., & Redmond, S. M. (2022) · Journal of Speech Language and Hearing Research · doi:10.1044/2022_jslhr-21-00628 · Cited by 37
Senkus, K. E., Crowe-White, K. M., Locher, J. L., & Ard, J. D. (2022) · Annals of Medicine · doi:10.1080/07853890.2022.2067352 · Cited by 28
Dunbar, H., Behning, C., Abdirahman, A., Higgins, B. E., Binns, A. M., Terheyden, J. H., Zakaria, N., Poor, S. H., Finger, R. P., Leal, S., et al. (2022) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2022.2113 · Cited by 31
Ghaffari, A., Rahbek, O., Lauritsen, R. E. K., Kappel, A., Kold, S., & Rasmussen, J. (2022) · Sensors · doi:10.3390/s22145289 · Cited by 29
rPPG-FuseNet: Non-contact heart rate estimation from facial video via RGB/MSR signal fusion
Jaiswal, K. B., & Meenpal, T. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104002 · Cited by 28
Ghosh, M. K., Elliott, S. N., Somers, K. P., Klippenstein, S. J., & Curran, H. J. (2022) · Combustion and Flame · doi:10.1016/j.combustflame.2022.112492 · Cited by 26
Chia, Y. C., Ching, S. M., Ooi, P. B., Beh, H. C., Chew, M. T., Chung, F. F., Devaraj, N. K., & Lim, H. M. (2023) · PLoS ONE · doi:10.1371/journal.pone.0280483 · Cited by 31
Nakamura, T., Nishida, T., Isogai, N., Kojima, T., Sugiyama, Y., & Yoshida, Y. (2023) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000001140 · Cited by 26
Banerjee, A., Bhattacharyya, N. K., Ghosh, R., Singh, S., Adhikari, A., Mondal, S., Roy, L., Bajaj, A., Ghosh, N., Bhushan, A., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-29041-w · Cited by 29
Mass Spectrometry-Based Evaluation of the Bland–Altman Approach: Review, Discussion, and Proposal
Tsikas, D. (2023) · Molecules · doi:10.3390/molecules28134905 · Cited by 27
Tillett, W. L., Jadon, D. R., Shaddick, G., Robinson, G., Sengupta, R., Korendowych, E., de Vries, C. S., & McHugh, N. J. (2013) · Arthritis Care & Research · doi:10.1002/acr.22104 · Cited by 26
Validity of self‐assessed waist circumference in a multi‐ethnic UK population
Khunti, K., Taub, N. A., Webb, D. R., Srinivasan, B. T., Stockman, J. A., Griffin, S. J., Simmons, R. K., & Davies, M. J. (2011) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03478.x · Cited by 28
Impact of Software Settings on Multiple-Breath Washout Outcomes
Summermatter, S., Singer, F., Latzin, P., & Yammine, S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0132250 · Cited by 26
Assessing PaCO2 in acute respiratory disease: accuracy of a transcutaneous carbon dioxide device
Perrin, K., Wijesinghe, M., Weatherall, M., & Beasley, R. W. (2010) · Internal Medicine Journal · doi:10.1111/j.1445-5994.2010.02213.x · Cited by 26
Wittenmeier, E., Bellosevich, S., Mauff, S., Schmidtmann, I. M., Eli, M., Pestel, G., & Noppens, R. R. (2015) · Pediatric Anesthesia · doi:10.1111/pan.12683 · Cited by 32
Bidaurrazaga-Letona, I., Carvalho, H., Lekue, J., Badiola, A., Figueiredo, A. J., & Gil, S. M. (2015) · Revista Brasileira de Medicina do Esporte · doi:10.1590/1517-869220152102144406 · Cited by 22
Camargo, D. M., Santisteban, S., Paredes, E. A. P., Flórez, M., & Bueno, D. A. (2015) · Biomédica · doi:10.7705/biomedica.v35i3.2502 · Cited by 39
Zhang, Y., Heo, H., Jiang, S., Lee, D., Bottomley, P. A., & Zhou, J. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25873 · Cited by 28
Kar, J., Knutsen, A. K., Cupps, B. P., Zhong, X., & Pasque, M. K. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24576 · Cited by 26
Transonic, thermodilution, or ionic dialysance to manage vascular access: Which method is best?
Badr, B., Bories, P., Marais, R., Frat, B., Seigneuric, B., Longlune, N., Kamar, N., Maggioni, S., & Rostaing, L. P. E. (2013) · Hemodialysis International · doi:10.1111/hdi.12092 · Cited by 26
The Reproducibility of Heart Rate Recovery after Treadmill Exercise Test
Tülümen, E., Khalilayeva, I., Aytemir, K., Kaya, F. E. S. C. E. B., Deveci, O. S., Aksoy, H., Kocabaş, U., Okutucu, S., Tokgözoğlu, L., Kabakçı, G., et al. (2011) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00464.x · Cited by 28
Evaluation of the composition of omega‐3 fatty acids in dietary oil supplements
Hamilton, K. D., Brooks, P. R., HOLMES, M., Cunningham, J. H., & Russell, F. D. (2010) · Nutrition & Dietetics · doi:10.1111/j.1747-0080.2010.01453.x · Cited by 32
Translation and validation of the D anish F oot F unction I ndex ( FFI ‐ DK )
Jorgensen, J. E., Andreasen, J., & Rathleff, M. S. (2014) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12331 · Cited by 30
van Ravesteyn, N. T., Dallmeijer, A. J., Scholtes, V. A., Roorda, L. D., & Becher, J. G. (2009) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2009.03341.x · Cited by 26
Nonlinear model for estimating respiratory volume based on thoracoabdominal breathing movements
Raoufy, M. R., Hajizadeh, S., Gharibzadeh, S., Mani, A. R., Eftekhari, P., & Masjedi, M. R. (2012) · Respirology · doi:10.1111/j.1440-1843.2012.02251.x · Cited by 30
Perioperative on-site haemoglobin determination: as accurate as laboratory values?
Jaeger, M. T., Ashbury, T. L., Adams, M. A., & Duncan, P. G. (1996) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03013031 · Cited by 26
New electrode system for rapid whole-body and segmental bioimpedance assessment
TAN, Y. X., EZ, C. N., SUN, Y., Zhang, K., Wang, Z., & HEYMSFIELD, S. B. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199709000-00022 · Cited by 29
Repeatability of On‐ and Off‐Axis Eye Length Measurements Using the Lenstar
Schulle, K. L., & Berntsen, D. A. (2012) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182780bfd · Cited by 26
Luévano‐Contreras, C., Durkin, T., Pauls, M., & Chapman‐Novakofski, K. (2013) · International Journal of Food Sciences and Nutrition · doi:10.3109/09637486.2013.816939 · Cited by 30
Thelen, S., Rütt, J., Wild, M., Lögters, T. T., Windolf, J., & Koebke, J. (2009) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-009-0878-9 · Cited by 26
Assessing portable blood glucose meters for clinical use in cats in the United Kingdom
Dobromylskyj, M., & Sparkes, A. (2010) · Veterinary Record · doi:10.1136/vr.c4260 · Cited by 31
Zamparo, P., & Swaine, I. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00324.2012 · Cited by 26
CEDIA® Mycophenolic Acid Assay Compared With HPLC-UV in Specimens From Transplant Recipients
Westley, I. S., Ray, J. E., & Morris, R. G. (2006) · Therapeutic Drug Monitoring · doi:10.1097/01.ftd.0000243963.53322.8d · Cited by 26
The Validity of a New Noncontact Tonometer and Its Comparison with the Goldmann Tonometer
Lam, A. K. C., Chan, R., & LAM, C.-H. (2004) · Optometry and Vision Science · doi:10.1097/01.opx.0000141796.95597.43 · Cited by 26
Uittenbogaard, L. B., Haak, M. C., Peters, R. J. A., van Couwelaar, G. M., & van Vugt, J. M. G. (2010) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.7561 · Cited by 27
Assessing the quality of the data in a transplant registry: the European Liver Transplant Registry
van der Meulen, J., Jacob, M. O., & Copley, L. P. (2003) · Transplantation · doi:10.1097/01.tp.0000080272.48725.8d · Cited by 26
Maribo, T., Stengaard‐Pedersen, K., Jensen, L. D., Andersen, N. T., & Schiøttz‐Christensen, B. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.04.014 · Cited by 26
Variability in the Epworth sleepiness scale score between the patient and the partner
Kumru, H., Santamaría, J., & Belcher, R. (2004) · Sleep Medicine · doi:10.1016/j.sleep.2004.03.003 · Cited by 29
Owen, R., Kron, T., Foroudi, F., Milner, A. D., Cox, J., Duchesne, G. M., Cleeve, L. K., Zhu, L., Cramb, J., Sparks, L., et al. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.01.054 · Cited by 32
Does it matter how we measure metatarsal length?
Chauhan, D., Bhutta, M. A., & Barrie, J. L. (2010) · Foot and Ankle Surgery · doi:10.1016/j.fas.2010.02.006 · Cited by 26
Naples, L. M., Mylniczenko, N. D., Zachariah, T. T., Wilborn, R. E., & Young, F. A. (2012) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.241.1.117 · Cited by 26
Validation of a single-stage submaximal treadmill walking test
Waddoups, L. J., Wagner, D. R., Fallon, J. A., & Heath, E. M. (2008) · Journal of Sports Sciences · doi:10.1080/02640410701591425 · Cited by 26
Heijmen, L., de Geus‐Oei, L., de Wilt, J. H. W., Visvikis, D., Hatt, M., Visser, E. P., Bussink, J., Punt, C. J. A., Oyen, W. J. G., & van Laarhoven, H. W. M. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2233-6 · Cited by 27
Measurement of peak esophageal luminal cross‐sectional area utilizing nadir intraluminal impedance
Zifan, A., Ledgerwood-Lee, M. M., & Mittal, R. K. (2015) · Neurogastroenterology & Motility · doi:10.1111/nmo.12571 · Cited by 26
Evaluation of Brugada syndrome by cardiac magnetic resonance
Tessa, C., Meglio, J. D., Ottonelli, A. G., Diciotti, S., Salvatori, L., Magnacca, M., Chioccioli, M., Lera, J., Vignali, C., & Casolo, G. (2012) · International journal of cardiac imaging · doi:10.1007/s10554-012-0009-5 · Cited by 26
Naßenstein, K., Orzada, S., Haering, L., Czylwik, A., Zenge, M. O., Eberle, H. C., Schlosser, T. W., Bruder, O., Müller, E., Ladd, M. E., et al. (2011) · European Radiology · doi:10.1007/s00330-011-2279-z · Cited by 26
Validity and Interobserver Reliability of Visual Observation to Assess Partial Weight-Bearing
Hurkmans, H. L. P., Bussmann, J. B. J., & Benda, E. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.07.022 · Cited by 28
Markhorst, D. G., van Genderingen, H. R., & van Vught, A. J. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2446-7 · Cited by 26
Cowan, R. E., Nash, M. S., de Groot, S., & van der Woude, L. H. V. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.03.010 · Cited by 26
Williams, J. E., Wells, J. C. K., Benden, C., Jaffé, A., Suri, R., Wilson, C. M., & Fewtrell, M. S. (2010) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.2010.29847 · Cited by 28
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.