STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 17,701–17,800 of 47,868
The effect of inhaling a dry powder of sodium chloride on the airways of asthmatic subjects
Anderson, S. D., Spring, J., MOORE, B. J., Rodwell, L., Spalding, N., Gonda, I., Chan, H., Walsh, A., & Clark, A. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10112465 · Cited by 27
Imaging and Diagnostic Testing
Ekery, D., Davidoff, R., Orlandi, Q. G., Apstein, C. S., Hesselvik, J. F., Shemin, R. J., & Shapira, O. M. (2003) · American Heart Journal · doi:10.1016/s0002-8703(02)94786-1 · Cited by 30
Does B-mode common carotid artery intima-media thickness differ from M-model?
Bortel, L. M. V., Vanmolkot, F. H. M., Spek, J. J., Bregu, M., Staessen, J. A., & Hoeks, A. P. G. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00448-3 · Cited by 27
Accuracy of Portable Blood Glucose Monitoring: Effect of Glucose Level and Prandial State
Vallera, D. A., Bissell, M. G., & Barron, W. M. (1991) · American Journal of Clinical Pathology · doi:10.1093/ajcp/95.2.247 · Cited by 32
Altunkan, Ş., Yildiz, S., & Azer, S. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200210000-00006 · Cited by 27
Primary solid neoplasms of the greater omentum.
Schwartz, R. W., Reames, M. K., McGrath, P. C., Letton, R. W., Appleby, G. A. J., & Kenady, D. E. (1991) · PubMed · Cited by 32
Royse, C. F., Royse, A. G., Blake, D. W., & Grigg, L. (1999) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9902700605 · Cited by 27
Subjective Assessment of Visual Verticality in follow-up of Patients with Acute Vestibular Disease
García, A. G., & Jáuregui‐Renaud, K. (2003) · Ear Nose & Throat Journal · doi:10.1177/014556130308200614 · Cited by 27
Chan, C. L. H., Scott, S. M., Birch, M., Knowles, C. H., Williams, N. S., & Lunniss, P. J. (2003) · Diseases of the Colon & Rectum · doi:10.1007/s10350-004-6613-2 · Cited by 27
Traduction et validation dˈune échelle algofonctionnelleadaptée aux cervicalgies
Wlodyka-Demaille, S., Poiraudeau, S., Fermanian, J., Catanzariti, J.-F., Rannou, F., & Revel, M. (2001) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/s0168-6054(01)00075-7 · Cited by 27
Multi‐slice dynamic imaging: Complete functional cardiac MR examination within 15 seconds
Bornstedt, A., Nagel, E. C., Schalla, S. M., Schnackenburg, B., Klein, C., & Fleck, E. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1186 · Cited by 29
Computer versus manual measurement of ST-segment deviation
Pelter, M. M., Adams, M. G., & Drew, B. J. (1996) · Journal of Electrocardiology · doi:10.1016/s0022-0736(96)80024-0 · Cited by 27
Bone Density and Insertion Torque as Predictors of Anterior Cruciateligament Graft Fixation Strength
Järvinen, T. L. N., Nurmi, J. T., & Sievänen, H. T. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503262168 · Cited by 27
Johansen, M. J., Madden, T. L., Mehra, R. C., Wood, J. G., Rondón, G., Browne, V., Newman, R. A., & Champlin, R. E. (1997) · Journal of Clinical Oncology · doi:10.1200/jco.1997.15.4.1481 · Cited by 27
Pfister, C., Buzelin, F., Cassé, C., Bochereau, G., Buzelin, J. M., & Bouchot, O. (1998) · European Urology · doi:10.1159/000019580 · Cited by 27
Accurate screening for abdominal aortic aneurysm
Grimshaw, G. M., & Docker, M. F. (1992) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/13/2/005 · Cited by 27
Koide, Y., Yotsukura, M., Yoshino, H., & Ishikawa, K. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01233-9 · Cited by 27
Weiss, S. J., Calloway, E., Cairo, J. M., Granger, W. M., & Winslow, J. (1995) · The American Journal of Emergency Medicine · doi:10.1016/0735-6757(95)90045-4 · Cited by 27
Herman, A., Maymon, R., Dreazen, E., Caspi, E., Bukovsky, I., & Weinraub, Z. (1998) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1998.11040266.x · Cited by 27
Gil, R. J., von Birgelen, C., Prati, F., Mario, C. D., Ligthart, J. M. R., & Serruys, P. W. J. C. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)89214-4 · Cited by 27
Reilly, J. J., & Workman, P. (1994) · Cancer Chemotherapy and Pharmacology · doi:10.1007/bf00686105 · Cited by 28
Silke, B., Spiers, P., Boyd, S., Graham, E., McParland, G., & Scott, M. (1994) · Clinical Autonomic Research · doi:10.1007/bf01828838 · Cited by 27
Modification of Pleural Fluid p H by Local Anesthesia
Castro, D. J., Díaz, G., Pérez-Rodríguez, E., Prieto, E., & Yusen, R. D. (1999) · CHEST Journal · doi:10.1378/chest.116.2.399 · Cited by 27
Pianosi, P. T. (1997) · CHEST Journal · doi:10.1378/chest.111.2.333 · Cited by 27
Evaluation of the COBAS TaqMan 48 Real-Time PCR System for Quantitation of Hepatitis B Virus DNA
Gordillo, R. M., Gutiérrez, J., & Casal, M. J. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.7.3504-3507.2005 · Cited by 27
Standardization Of Hapten Immunoprocedures: Total Cortisol
Gosling, J. P., Middle, J. G., Siekmann, L., & Read, G. (1993) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519309086907 · Cited by 27
Winter, O., Bondt, P. D., de Wiele, C. V., Backer, G. D., Dierckx, R. A. J. O., & SUTTER, J. D. (2004) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2003.09.010 · Cited by 27
Möller, R., Tafeit, E., Sudi, K. M., & Reibnegger, G. J. (2000) · Annals of Human Biology · doi:10.1080/030144600282370 · Cited by 34
Jonescu-Cuypers, C. P. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.3.304 · Cited by 27
Effects of intrapulmonary insulin in patients with non-insulin-dependent diabetes
JENDLE, J. H., & Karlberg, B. E. (1996) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519609088811 · Cited by 27
The development and validation of an instrument to assess acute sinus disease in children
Garbutt, J. M., Gellman, E. F., & Littenberg, B. (1999) · Quality of Life Research · doi:10.1023/a:1008883508462 · Cited by 29
Clinical evaluation of a multiparameter intra-arterial blood-gas sensor
Abraham, E., Gallagher, T. J., & Fink, S. (1996) · Intensive Care Medicine · doi:10.1007/bf01712177 · Cited by 27
Polosa, R., Rajakulasingam, K., Prosperini, G., Church, M. K., & Holgate, S. T. (1993) · Journal of Allergy and Clinical Immunology · doi:10.1016/0091-6749(93)90172-c · Cited by 27
Submissions toRadiology: Our Top 10 List of Statistical Errors
Levine, D., Bankier, A. A., & Halpern, E. F. (2009) · Radiology · doi:10.1148/radiol.2532090759 · Cited by 27
Nevill, A. M. (1996) · Journal of Sports Sciences · doi:10.1080/02640419608727704 · Cited by 27
Stoffers, R. H., Madden, M. E., Shahid, M., Contijoch, F. J., Solomon, J., Pilla, J. J., Gorman, J. H., Gorman, R. C., & Witschey, W. R. T. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0354-6 · Cited by 27
De Rui, M., Veronese, N., Bolzetta, F., Berton, L., Carraro, S., Bano, G., Trevisan, C., Pizzato, S., Coin, A., Perissinotto, E., et al. (2017) · Clinical Nutrition · doi:10.1016/j.clnu.2016.04.011 · Cited by 26
Comparison of Body Composition Methods in Obese African‐American Women
Newton, R. L., Alfonso, A., York‐Crowe, E., Walden, H., White, M. A., Ryan, D., & Williamson, D. A. (2006) · Obesity · doi:10.1038/oby.2006.55 · Cited by 26
Hayward, G., Verbakel, J. Y., Ismail, F. A., Edwards, G., Wang, K., Fleming, S., Holtman, G. A., Glogowska, M., Morris, E., Curtis, K., et al. (2020) · British Journal of General Practice · doi:10.3399/bjgp20x708845 · Cited by 26
Mielke, G. I., de Almeida Mendes, M., Ekelund, U., Rowlands, A. V., Reichert, F. F., & Crochemore‐Silva, I. (2023) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.14416 · Cited by 26
Chien, J.-Y., Ruan, S.-Y., Huang, Y.-C. T., Yu, C.-J., & Yang, P.-C. (2013) · Respiratory Care · doi:10.4187/respcare.01522 · Cited by 26
Salika, T., Turner, R., Fisher, D. J., Tierney, J. F., & White, I. R. (2022) · BMC Medical Research Methodology · doi:10.1186/s12874-022-01541-9 · Cited by 28
Solorzano, C. S., Violani, C., & Grano, C. (2022) · Journal of Affective Disorders · doi:10.1016/j.jad.2022.09.056 · Cited by 30
Klier, K., Koch, L., Graf, L., Schinköthe, T., & Schmidt, A. (2023) · JMIR Cardio · doi:10.2196/50701 · Cited by 28
Haghshenas, Y., Wong, W. P., Gunawan, D., Khataee, A., Keyikoğlu, R., Razmjou, A., Kumar, P. V., Toe, C. Y., Masood, H., Amal, R., et al. (2023) · EES Catalysis · doi:10.1039/d3ey00246b · Cited by 30
Papadopoulou, S., Dionysopoulos, D., Mentesidou, V., Loga, K., Michalopoulou, S., Koukoutzeli, C., Efthimiadis, K. G., Kantartzi, V., Timotheadou, E. T., Stylıadis, I., et al. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztae017 · Cited by 26
Gomez, R., Zarate, D., Brown, T., Hein, K., & Stavropoulos, V. (2024) · Clinical Psychologist · doi:10.1080/13284207.2024.2341816 · Cited by 35
Automated monitoring of tooth wear progression using AI on intraoral scans
van Nistelrooij, N., Maier, E., Bronkhorst, H., Crins, L. A. M. J., Xi, T., Loomans, B. A. C., & Vinayahalingam, S. (2024) · Journal of Dentistry · doi:10.1016/j.jdent.2024.105323 · Cited by 27
Geng, X., Cai, S., & Gou, Z. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.124716 · Cited by 26
Ghosh, S. K., Widatalla, N., & Khandoker, A. H. (2025) · IEEE Access · doi:10.1109/access.2025.3565549 · Cited by 32
Estimation of kidney function in cancer patients.
Redal-Baigorri, B., Stokholm, K. H., Rasmussen, K., & Jeppesen, N. (2011) · PubMed · Cited by 26
Jasensky, A., Klenner, S., Einspanier, R., & Kohn, B. (2015) · Veterinary Clinical Pathology · doi:10.1111/vcp.12264 · Cited by 26
Hanson, L. C., Taylor, N. F., & McBurney, H. (2015) · Physiotherapy · doi:10.1016/j.physio.2015.08.004 · Cited by 28
Mocroft, A., Ryom, L., Reiss, P., Furrer, H., Monforte, A. D., Gatell, J. M., Wit, S. D., Beniowski, M., Lundgren, J. D., Kirk, O., et al. (2013) · HIV Medicine · doi:10.1111/hiv.12095 · Cited by 29
Assessing pain in ventilated newborns and infants: validation of the Hartwig score
Hünseler, C., Merkt, V., Gerloff, M., Eifinger, F., Kribs, A., & Roth, B. (2010) · European Journal of Pediatrics · doi:10.1007/s00431-010-1354-9 · Cited by 26
Galstyan, G. M., Bychinin, M., Alexanyan, M., & Gorodetsky, V. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-2003-5 · Cited by 26
Thermodilution vs pressure recording analytical method in hemodynamic stabilized patients
Donati, A., Carsetti, A., Tondi, S., Scorcella, C., Domizi, R., Damiani, E., Gabbanelli, V., Münch, C. M., Adrario, E., Pelaia, P., et al. (2013) · Journal of Critical Care · doi:10.1016/j.jcrc.2013.11.003 · Cited by 28
Beda, A., Güldner, A., Carvalho, A. R., Zin, W. A., Carvalho, N. C. S., Huhle, R., Giannella‐Neto, A., Koch, T., & de Abreu, M. G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103057 · Cited by 28
Filusch, A., Mereles, D., Grünig, E., Buss, S. J., Katus, H. A., & Meyer, F. J. (2010) · Clinical Research in Cardiology · doi:10.1007/s00392-010-0147-5 · Cited by 26
Coote, S. B., & O’Dwyer, C. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.05.010 · Cited by 29
Carvalho, M. A. G., Baranowski, T., Foster, E., Santos, O., Cardoso, B., Rito, A. I., & Miguel, J. P. (2014) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12280 · Cited by 26
Bailliez, A., Blaire, T., Mouquet, F., Legghe, R., Etienne, B., Legallois, D., Agostini, D., & Manrique, A. (2014) · Journal of Nuclear Cardiology · doi:10.1007/s12350-014-9899-z · Cited by 26
The use of videofluoroscopy in the assessment of the pharyngeal airway in obstructive sleep apnoea
Johal, A., Sheriteh, Z., Battagel, J. M., & Marshall, C. (2011) · European Journal of Orthodontics · doi:10.1093/ejo/cjq058 · Cited by 27
Self-regulatory practices of drivers with Parkinson's disease: Accuracy of patient reports
Crizzle, A. M., Myers, A. M., & Almeida, Q. J. (2012) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2012.09.003 · Cited by 31
Evaluation of a new semi-continuous cardiac output system in the intensive care unit
Seguin, P., Colcanap, O., Rouzo, A. L., Tanguy, M., Guillou, Y., & Mallédant, Y. (1998) · Canadian Journal of Anaesthesia-journal Canadien D Anesthesie · doi:10.1007/bf03012713 · Cited by 10
González‐Méijome, J. M., Jorge, J., Rey, A., & Rosado (2013) · Clinical ophthalmology · doi:10.2147/opth.s35121 · Cited by 26
Signal Analysis and Classification for Surface Plasmon Assisted Microscopy of Nanoobjects
Weichert, F., Gaspar, M. B., Timm, C., Zybin, A., Gurevich, E. L., Engel, M., Müller, H., & Marwedel, P. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.08.005 · Cited by 26
Dalton, B., Sabuda, D. M., Bresee, L. C., & Conly, J. M. (2015) · Infection Control and Hospital Epidemiology · doi:10.1017/ice.2015.46 · Cited by 26
Sievers, B., Wiesner, M., Kiria, N., Speiser, U., Schoen, S., & Strasser, R. H. (2011) · Acta Radiologica · doi:10.1258/ar.2011.100505 · Cited by 26
Abraham, M., Reef, V. B., Sweeney, R. W., & de Solís, C. N. (2014) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.12413 · Cited by 26
Absolute and Relative Reliability of Percentage of Syllables Stuttered and Severity Rating Scales
Karimi, H., O’Brian, S., Onslow, M., & Jones, M. (2014) · Journal of Speech Language and Hearing Research · doi:10.1044/2014_jslhr-s-13-0106 · Cited by 34
A tactile method for canal length determination in teeth with open apices
ElAyouti, A., Dima, E., & Löst, C. (2009) · International Endodontic Journal · doi:10.1111/j.1365-2591.2009.01636.x · Cited by 26
Bell, K. L., Boyd, R. N., Walker, J. L., Stevenson, R. D., & Davies, P. S. W. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.10.005 · Cited by 26
Test-Retest Reliability in Quantitative Physical Education Research: A Commentary
Lamb, K. (1998) · European Physical Education Review · doi:10.1177/1356336x9800400205 · Cited by 26
The Development of a Soccer-Specific Training Drill for Elite-Level Players
Kelly, D. M., Gregson, W., Reilly, T., & Drust, B. (2013) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3182610b7d · Cited by 27
Simões, R. P., Castello‐Simões, V., Mendes, R. G., Archiza, B., dos Santos, D. A., Bonjorno, J. C., de Oliveira, C. R., Catai, A. M., Arena, R. A., & Borghi‐Silva, A. (2013) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12070 · Cited by 35
The reliability of running economy among trained distance runners and field-based players
Doma, K., Deakin, G. B., Leicht, A. S., & Sealey, R. (2012) · Journal of Exercise Science & Fitness · doi:10.1016/j.jesf.2012.10.006 · Cited by 26
Briggs, M., Rumbold, P., Cockburn, E., Russell, M., & Stevenson, E. (2015) · Nutrients · doi:10.3390/nu7075262 · Cited by 25
Limitations of serum values to estimate glomerular filtration rate during exercise
POORTMANS, J. R., Gulbis, B., Bruyn, E. D., Baudry, S., & Carpentier, A. (2012) · British Journal of Sports Medicine · doi:10.1136/bjsports-2012-090976 · Cited by 33
Bañuls, C., Bellod, L., Jover, A., Martínez-Triguero, M. L., Víctor, V. M., Rocha, M., & Hernández‐Mijares, A. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.09.047 · Cited by 28
Issues and pitfalls in method comparison studies
Hartnack, S. (2014) · Veterinary Anaesthesia and Analgesia · doi:10.1111/vaa.12143 · Cited by 31
Evaluation of two devices for point-of-care testing of haemoglobin in neonatal pigs
Kutter, A. P. N., Mauch, J. Y., Riond, B., Martin‐Jurado, O., Spielmann, N., Weiß, M., & Bettschart‐Wolfensberger, R. (2011) · Laboratory Animals · doi:10.1258/la.2011.011086 · Cited by 26
Parsons, T. L., Marzinke, M. A., Hoang, T., Bliven-Sizemore, E., WEINER, M. H., Kenzie, W. R. M., Dorman, S. E., & Dooley, K. E. (2014) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.03607-14 · Cited by 26
DeBuc, D. C., Salinas, H. M., Ranganathan, S., Tátrai, E., Gao, W., Shen, M., Wang, J., Somfai, G. M., & Puliafito, C. A. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3470116 · Cited by 26
Keller, T., Freynhagen, R., Tölle, T. R., Liwowsky, I., Möller, P., Hüllemann, P., Gockel, U., Stemmler, E., & Baron, R. (2015) · Current Medical Research and Opinion · doi:10.1185/03007995.2015.1125869 · Cited by 27
Belarmino, G., Horie, L. M., Sala, P. C., Torrinhas, R. S., Heymsfield, S. B., & Waitzberg, D. L. (2015) · Nutrition Journal · doi:10.1186/s12937-015-0119-8 · Cited by 26
Lee, A. L., Cecins, N. M., Holland, A. E., Hill, C. J., McDonald, C. F., Burge, A. T., Rautela, L., Thompson, P. J., Stirling, R. G., & JENKINS, S. C. (2015) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0000000000000130 · Cited by 26
Trinkmann, F., Berger, M., Doesch, C., Papavassiliu, T., Schoenberg, S. O., Borggrefe, M. M., Kaden, J. J., & Saur, J. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9731-6 · Cited by 26
Pereira, T. S., Maldonado, J. M. P., Coutinho, R., Cardoso, E., Laranjeiro, M., Andrade, I., & Conde, J. (2014) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000058 · Cited by 26
Maximum Diameter of Native Abdominal Aortic Aneurysm Measured by Angio-Computed Tomography
Mora, C., Marcus, C. D., Barbe, C., Ecarnot, F., & Long, A. (2015) · Aorta · doi:10.12945/j.aorta.2015.14-059 · Cited by 26
Conventional and Ambulatory Blood Pressure as Predictors of Retinal Arteriolar Narrowing
Wei, F., Zhang, Z., Thijs, L., Yang, W., Jacobs, L., Cauwenberghs, N., Gu, Y., Kuznetsova, T., Allegaert, K., Verhamme, P. B., et al. (2016) · Hypertension · doi:10.1161/hypertensionaha.116.07523 · Cited by 34
Three-dimensional evaluation of social smile symmetry
Duran, G. S., Di̇ndaroğlu, F., & Görgülü, S. (2016) · The Angle Orthodontist · doi:10.2319/020916-112.1 · Cited by 26
Hansen, M. S., Barfod, K. W., & Kristensen, M. T. (2016) · Foot and Ankle Surgery · doi:10.1016/j.fas.2016.08.002 · Cited by 26
Tibial plateau levelling osteotomy in eleven cats with cranial cruciate ligament rupture
Bielecki, M., Scharvogel, S., Meiler, D., & Mindner, J. K. (2016) · Veterinary and Comparative Orthopaedics and Traumatology · doi:10.3415/vcot-15-11-0184 · Cited by 26
O’Leary, F., John‐Denny, B., McGarvey, K., Hann, A., Pegiazoglou, I., & Peat, J. K. (2016) · Archives of Disease in Childhood · doi:10.1136/archdischild-2016-310917 · Cited by 28
El protocolo de investigación IV: las variables de estudio
Villasís-Keever, M. Á., & Miranda-Novales, M. G. (2016) · Revista Alergia México · doi:10.29262/ram.v63i3.199 · Cited by 137
Donohue, K. W., Little, K. J., Gaughan, J., Kozin, S. H., Norton, B., & Zlotolow, D. A. (2017) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.15.01116 · Cited by 26
Fuller, N. R., Fong, M., Gerofi, J. A., Ferkh, F., Leung, C., Leung, L., Zhang, S., Skilton, M. R., & Caterson, I. D. (2017) · Obesity Research & Clinical Practice · doi:10.1016/j.orcp.2017.04.001 · Cited by 33
dos Santos, R. M. G., Martino, J. M. D., Neto, F. H., & Pásseri, L. A. (2017) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2016.12.023 · Cited by 26
Spatial distribution of flow and oxygenation in the cerebral venous drainage system
Vis, J. B. D., Lu, H., Ravi, H., Hendrikse, J., & Liu, P. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25833 · Cited by 26
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.