STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 21,601–21,700 of 47,868
Neto, G. D. A. M., de León, A. P., Lira, V. A., & Farinatti, P. (2011) · Journal of Aging Research · doi:10.1155/2012/518045 · Cited by 20
Influence of radiographic phenotype on risk of hip osteoarthritis within families
Lanyon, P., Muir, K. R., Doherty, S., & Doherty, M. (2004) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2002.003780 · Cited by 20
Svenmarker, S., Appelblad, M., Jansson, E., & Häggmark, S. (2004) · Perfusion · doi:10.1191/0267659104pf755oa · Cited by 20
Measurement of the Vertebral Canal Dimensions of the Neck of the Rat with a Comparison to the Human
Flynn, J. R., & Bolton, P. S. (2007) · The Anatomical Record · doi:10.1002/ar.20523 · Cited by 20
Reproducibility of pulse wave analysis and pulse wave velocity in patients with type 2 diabetes
Laugesen, E., Rossen, N. B., Høyem, P., Christiansen, J. S., Knudsen, S. T., Hansen, K. W., Hansen, T. K., & Poulsen, P. L. (2013) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2013.800578 · Cited by 22
Signal/Noise Analysis to Compare Tests for Measuring Visual Field Loss and Its Progression
Artes, P. H., & Chauhan, B. C. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3601 · Cited by 20
Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging
Knešaurek, K., Macháč, J., & Zhang, Z. (2009) · BMC Medical Physics · doi:10.1186/1756-6649-9-2 · Cited by 20
Compton, F., Wittrock, M., Schaefer, J.-H., Zidek, W., Tepel, M., & Scholze, A. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000297440.52059.2c · Cited by 20
Calf Muscle Volume Estimates: Implications for Botulinum Toxin Treatment?
Bandholm, T., Sonne‐Holm, S., Thomsen, C. E., Bencke, J., Pedersen, S. A., & Jensen, B. R. (2007) · Pediatric Neurology · doi:10.1016/j.pediatrneurol.2007.05.019 · Cited by 22
Varewijck, A. J., Lamberts, S. W. J., van der Lely, A. J., Neggers, S. J. C. M. M., Hofland, L. J., & Janssen, J. A. M. J. L. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2558 · Cited by 20
Cid, J., Nascimento, J. D., Vicent, A., Aguinaco, R., Escoda, L., Ugarriza, A., & Llorente, A. (2009) · Transfusion · doi:10.1111/j.1537-2995.2009.02504.x · Cited by 20
Silberer, J., Ihorst, G., & Kopp, M. (2007) · Pediatric Allergy and Immunology · doi:10.1111/j.1399-3038.2007.00605.x · Cited by 20
Blanc, S., Colman, R. J., Kemnitz, J. W., Weindruch, R. H., Baum, S., Ramsey, J. J., & Schoeller, D. A. (2005) · Journal of Medical Primatology · doi:10.1111/j.1600-0684.2005.00106.x · Cited by 21
on behalf of the PROOF Study Group, Chouchou, F., Sforza, E. A., Celle, S., Pichot, V., Maudoux, D., Garcin, A., Barthélemy, J., & Roche, F. (2011) · SLEEP · doi:10.5665/sleep.1160 · Cited by 20
Bernau, M., Kremer, P. V., Lauterbach, E., Tholen, E., Petersen, B., Pappenberger, E., & Scholz, A. M. (2015) · Meat Science · doi:10.1016/j.meatsci.2015.01.011 · Cited by 25
Tzamalis, A. K., Kynigopoulos, M., Schlote, T., & Haefliger, I. O. (2008) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-008-0946-9 · Cited by 20
Repeatability in computer‐aided diagnosis: Application to breast cancer diagnosis on sonography
Drukker, K., Pesce, L. L., & Giger, M. L. (2010) · Medical Physics · doi:10.1118/1.3427409 · Cited by 20
Morphological Analysis of Pancreatic Cystic Masses
Lasboo, A. A., Rezai, P., & Yaghmai, V. (2009) · Academic Radiology · doi:10.1016/j.acra.2009.09.013 · Cited by 20
Computed tomography dose and variability of airway dimension measurements: how low can we go?
de Jong, P. A., Long, F. R., & Nakano, Y. (2006) · Pediatric Radiology · doi:10.1007/s00247-006-0264-5 · Cited by 20
In vitroassessment of equipment and software to assess tidal breathing parameters in infants
Schmalisch, G., Foitzik, B., Wauer, R. R., & Stocks, J. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.17101000 · Cited by 20
Evaluation of the Rice pelvimeter for measuring pelvic area in double muscled Belgian Blue cows
Kolkman, I., Hoflack, G., Aerts, S., Murray, R. D., Opsomer, G., & Lips, D. (2008) · Livestock Science · doi:10.1016/j.livsci.2008.06.022 · Cited by 20
Static Intrinsic PEEP in COPD Patients during Spontaneous Breathing
Purro, A., Appendini, L., PATESSIO, A., ZANABONI, S., Guðjónsdóttir, M., Rossi, A., & Donner, C. F. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.4.9702007 · Cited by 20
Development of a competitive immunoassay for efavirenz: Hapten design and validation studies
Roucairol, C., Azoulay, S., Nevers, M., Créminon, C., Grassi, J., Burger, A., & Duval, D. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.02.045 · Cited by 20
Determining the Minimum Discard Volume for Central Venous Catheter Blood Draws
Wyant, S., & Crickman, R. (2012) · Clinical journal of oncology nursing · doi:10.1188/12.cjon.454-458 · Cited by 22
Su, Z., Tan, W., Shandas, R., & Hunter, K. S. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/618326 · Cited by 20
Longitudinal Study of Normal Hip Development by Ultrasound
Riad, J. P., Cundy, P. J., Gent, R. J., Piotto, L., Morris, L. L., & Hirte, C. (2004) · Journal of Pediatric Orthopaedics · doi:10.1097/00004694-200501000-00003 · Cited by 20
Reliable Angle Assessment During Periacetabular Osteotomy with a Novel Device
Troelsen, A., Elmengaard, B., Rømer, L., & Søballé, K. (2008) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0133-7 · Cited by 20
Preliminary experience with electromagnetic navigation system in TKA
Tigani, D. S., Busacca, M., Moio, A., Rimondi, E., Piccolo, N. D., & Sabbioni, G. (2008) · The Knee · doi:10.1016/j.knee.2008.09.004 · Cited by 20
Zhou, S. J., Schilling, M. J., & Makrides, M. (2005) · Nutrition · doi:10.1016/j.nut.2004.11.020 · Cited by 20
de Souza, J. F., Diniz, M. B., Boldieri, T., Rodrigues, J. A., Lussi, A., & Cordeiro, R. D. C. (2014) · Indian Journal of Dental Research · doi:10.4103/0970-9290.152165 · Cited by 20
Jedenmalm, A., Noz, M. E., Olivecrona, H., Olivecrona, L., & Stark, A. (2008) · Acta Orthopaedica · doi:10.1080/17453670710015003 · Cited by 20
Salvetat, M. L., Zeppieri, M., Tosoni, C., & Brusini, P. (2013) · Acta Ophthalmologica · doi:10.1111/aos.12209 · Cited by 20
Nocturnal dipping is reproducible in the long term
McGowan, N. J., Gough, K., & Padfield, P. L. (2009) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32832ff4e1 · Cited by 20
Reske, A. W., Reske, A. P., Heine, T., Spieth, P. M., Rau, A., Seiwerts, M., Busse, H., Gottschaldt, U., Schreiter, D., Born, S., et al. (2011) · Critical Care · doi:10.1186/cc10060 · Cited by 22
Kolus, A., Imbeau, D., Dubé, P.-A., & Dubeau, D. (2015) · Applied Ergonomics · doi:10.1016/j.apergo.2015.03.001 · Cited by 22
The effect of ketanserin on healing of fresh surgical wounds
Lawrence, C. M., Matthews, J. N. S., & Cox, N. H. (2006) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1995.tb08714.x · Cited by 22
Comparison of estimated GFR and measured GFR in prospective living kidney donors
Bhuvanakrishna, T., Blake, G. M., Hilton, R. M., Burnapp, L., Sibley-Allen, C., & Goldsmith, D. J. A. (2014) · International Urology and Nephrology · doi:10.1007/s11255-014-0859-y · Cited by 23
Bentley, S. A., LeBlanc, R. P., Nicolela, M. T., & Chauhan, B. C. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-9718 · Cited by 28
AlFadhli, S. M., & Al-Awadhi, A. M. (2005) · Medical Principles and Practice · doi:10.1159/000085742 · Cited by 32
Shi, C., Boehme, S., Bentley, A. H., Hartmann, E. K., Klein, K. U., Bodenstein, M., Baumgardner, J. E., David, M., Ullrich, R., & Markstaller, K. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086638 · Cited by 20
Shah, N., Laidlaw, D. A. H., Brown, G. M., & Robson, C. (2010) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2009.00700.x · Cited by 20
Ultrasound velocity measurement to determine lipid content in salmon muscle; the effects of myosepta
Shannon, R., Probert-Smith, P., Lines, J. A., & Mayia, F. (2004) · Food Research International · doi:10.1016/j.foodres.2004.01.012 · Cited by 20
Hind, K., Cooper, W. M., Oldroyd, B., Davies, A. G., & Rhodes, L. (2013) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2013.09.011 · Cited by 20
Validation of Online Administration of the Sexual Health Inventory for Men
Bernstein, A., Levinson, A. W., Hobbs, A. R., Lavery, H. J., & Samadi, D. B. (2012) · The Journal of Urology · doi:10.1016/j.juro.2012.10.053 · Cited by 21
Parental assessment of adolescent quality of life: can it replace self-assessment?
Taylor, R. M., Grieve, A. P., Gibson, F., Dhawan, A. K., & Franck, L. S. (2011) · Quality of Life Research · doi:10.1007/s11136-011-9904-9 · Cited by 20
DMA Clinical Pilates Directional-Bias Assessment: Reliability and Predictive Validity
Tulloch, E., Phillips, C., Sole, G., Carman, A. B., & Abbott, J. H. (2012) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2012.3790 · Cited by 22
Li, X., Ymeti, A., Lunter, B., Breukers, C., Tibbe, A. G. J., Terstappen, L. W. M. M., & Greve, J. (2007) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.20165 · Cited by 20
Tertti, R., Harmoinen, A. P. T., Leskinen, Y., Metsarinne, K. P., & Saha, H. H. T. (2007) · Hemodialysis International · doi:10.1111/j.1542-4758.2007.00210.x · Cited by 20
Maredia, N., Kozerke, S., Larghat, A., Abidin, N., Greenwood, J. P., Boesiger, P., & Plein, S. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-27 · Cited by 20
Wang, S.-Y., Cheng, M., Hwang, J., Hung, C., & Wu, Y. (2010) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3283422838 · Cited by 20
Chinn, S., & Schouten, J. P. (2005) · Thorax · doi:10.1136/thx.2004.039230 · Cited by 20
Chen, T., Yang, Z., Li, Y., Li, Z.-L., Yao, J., & Sun, J. (2008) · Clinical Radiology · doi:10.1016/j.crad.2008.06.005 · Cited by 20
Asbeutah, A. M., Riha, A. Z., Cameron, J. D., & McGrath, B. P. (2005) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2005.24.4.475 · Cited by 20
Robinson, G. J. B., Peyton, P. J., Terry, D., Malekzadeh, S., & Thompson, B. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01197.2003 · Cited by 20
Bajor, A., Kilander, A. F., Sjövall, H., Rudling, M., & Ung, K. (2008) · Digestive Diseases and Sciences · doi:10.1007/s10620-008-0256-4 · Cited by 20
Skouroliakou, M., Giannopoulou, I., Kostara, C. E., & Vasilopoulou, M. (2008) · Nutrition · doi:10.1016/j.nut.2008.08.006 · Cited by 22
Neil‐Sztramko, S., Myring, A., Peeters, M. J., Pirie, I., Jacobs, R., Hunt, M. A., Garland, S. J., & Campbell, K. L. (2013) · Physiotherapy Theory and Practice · doi:10.3109/09593985.2013.779337 · Cited by 20
Comhaire, F. H., Criel, A. C. C., Dassy, C. A. A., Guévar, P. G. J., & Snaps, F. (2009) · American Journal of Veterinary Research · doi:10.2460/ajvr.70.2.228 · Cited by 20
Kim, J., Nam, K. W., Jang, I. G., Yang, H. K., Kim, K. G., & Hwang, J. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-8329 · Cited by 20
Knee–heel length measurement in healthy preterm infants
Griffin, I. J., Pang, N., Perring, J., & Cooke, R. J. (1999) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.81.1.f50 · Cited by 20
Second Ventilatory Threshold From Heart-Rate Variability: Valid When the Upper Body Is Involved?
Mourot, L., Fabre, N., Savoldelli, A., & Schena, F. (2014) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2013-0286 · Cited by 25
Smart wearable device for real time gait event detection during running
Alahakone, A. U., Senanayake, S. M. N. A., & Senanayake, C. (2010) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas.2010.5774975 · Cited by 20
Myocardial function in premature infants: a longitudinal observational study
Eriksen, B. H., Nestaas, E., Hole, T., Liestøl, K., Støylen, A., & Fugelseth, D. (2013) · BMJ Open · doi:10.1136/bmjopen-2012-002441 · Cited by 20
Maguire, A. M., Ambler, G. R., Moore, B., Waite, K., McLean, M., & Cowell, C. T. (2007) · European Journal of Endocrinology · doi:10.1530/eje-06-0700 · Cited by 20
The prediction of height by armspan in older Chinese people
Kwok, T. C. Y., Lau, E., & Woo, J. (2002) · Annals of Human Biology · doi:10.1080/03014460210151732 · Cited by 20
Chinn, D. J. (2004) · Archives of Disease in Childhood · doi:10.1136/adc.2003.044578 · Cited by 20
Åkerblom, A., Wallentin, L. C., Larsson, A. O., Siegbahn, A. G., Becker, R. C., Budaj, A., Himmelmänn, A., Horrow, J. C., Husted, S., Storey, R. F., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.200709 · Cited by 20
Beier, J., Beeh, K.-M., Kornmann, O., & Buhl, R. (2004) · Journal of Laboratory and Clinical Medicine · doi:10.1016/j.lab.2004.04.001 · Cited by 20
Disparity in motorcycle helmet use in Thailand
Suriyawongpaisa, P., Thakkinstian, A., Rangpueng, A., Jiwattanakulpaisarn, P., & Techakamolsuk, P. (2013) · International Journal for Equity in Health · doi:10.1186/1475-9276-12-74 · Cited by 21
Capper, S. J., Ross, J. J., Sandström, E., Braidley, P. C., & Morgan‐Hughes, N. J. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem010 · Cited by 20
Comparison of Glucose Monitoring Methods during Steady-State Exercise in Women
Herrington, S. J., Gee, D. L., Dow, S. D., Monosky, K. A., Davis, E., & Pritchett, K. L. (2012) · Nutrients · doi:10.3390/nu4091282 · Cited by 22
Comparison of reading speed with 3 different log-scaled reading charts
Buari, N. H., Chen, A.-H., & Musa, N. (2014) · Journal of Optometry · doi:10.1016/j.optom.2013.12.009 · Cited by 20
Putting double marking to the test: a framework to assess if it is worth the trouble
Cannings, R., Hawthorne, K., Hood, K., & Houston, H. (2005) · Medical Education · doi:10.1111/j.1365-2929.2005.02093.x · Cited by 28
Bielli, M., Nardini, G., Girolamo, N. D., & Savarino, P. (2014) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638714561251 · Cited by 20
Jamaiyah, H., Geeta, A., Safiza, M. N. N., Wong, N. F., Kee, C. C., Ahmad, A. Z., Suzana, S., Rahmah, R., Khor, G. L., Ruzita, A. T., et al. (2008) · PubMed · Cited by 20
Syversveen, T., Brabrand, K., Midtvedt, K., Strøm, E. H., Hartmann, A., & Berstad, A. E. (2011) · Acta Radiologica · doi:10.1258/ar.2011.110215 · Cited by 20
Day-to-day variability in intraocular pressure in glaucoma and ocular hypertension
Rotchford, A. P., Uppal, S., Lakshmanan, A., & King, A. J. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-301266 · Cited by 22
Stuart, R. L. (2000) · Thorax · doi:10.1136/thorax.55.8.693 · Cited by 20
A Body Shape Index and Heart Rate Variability in Healthy Indians with Low Body Mass Index
Sharma, S., Thomas, T. S., Bharathi, A. V., & Sambashivaiah, S. (2014) · Journal of Nutrition and Metabolism · doi:10.1155/2014/865313 · Cited by 22
Arterial and end-tidal carbon dioxide difference in pediatric intensive care
Deep, A., Goonasekera, C. D. A., Goodwin, A., Wang, Y., & Goodman, J. (2014) · Indian Journal of Critical Care Medicine · doi:10.4103/0972-5229.144011 · Cited by 20
Three-Dimensional Echocardiographic Analysis of Left Ventricular Function during Hemodialysis
Krenning, B. J., Voormolen, M. M., Geleijnse, M. L., van der Steen, A. F. W., ten Cate, F. J., Ie, E. H. Y., & Roelandt, J. R. T. C. (2007) · Nephron Clinical Practice · doi:10.1159/000107553 · Cited by 20
Martínez, F. T., & Tobar, C. (2014) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2014.937794 · Cited by 22
Nuland, M. V., Noortgate, W. V. D., Degryse, J., & Goedhuys, J. (2007) · Medical Education · doi:10.1111/j.1365-2923.2007.02788.x · Cited by 25
Morriss, R. K., Yang, M., Chopra, A., Bentall, R. P., Paykel, E. S., & Scott, J. L. (2013) · Bipolar Disorders · doi:10.1111/bdi.12036 · Cited by 23
Izatt, M. T., Adam, C. J., Verzin, E. J., Labrom, R. D., & Askin, G. N. (2012) · Scoliosis · doi:10.1186/1748-7161-7-15 · Cited by 20
Ultrasonic Periodontal Probing Based on the Dynamic Wavelet Fingerprint
Hou, J., Rose, S. T., & Hinders, M. K. (2005) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/asp.2005.1137 · Cited by 20
Aortic root 3D parametric morphological model from 2D-echo images
Morganti, S., Valentini, A., Favalli, V., Serio, A., Gambarin, F. I., Vella, D., Mazzocchi, L., Massetti, M., Auricchio, F., & Arbustini, E. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.09.015 · Cited by 20
Zwijnenberg, R. J., del Rio, C. L., Cobb, R. M., Ueyama, Y., & Muir, W. W. (2011) · American Journal of Veterinary Research · doi:10.2460/ajvr.72.8.1015 · Cited by 22
Fontseré, N., Bonal, J., Salinas, I., de Arellano, M. R., Ríos, J., Torres, F., Sanmartı́, A., & Romero, R. (2008) · Diabetes Care · doi:10.2337/dc08-0958 · Cited by 20
Quantitative Airway Assessment on Computed Tomography in Patients with α1-antitrypsin Deficiency
Yamashiro, T., Matsuoka, S., Estépar, R. S. J., Díaz, A. A., Newell, J. D., Sandhaus, R. A., Mergo, P. J., Brantly, M., Murayama, S., Reilly, J. J., et al. (2009) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.3109/15412550903341521 · Cited by 21
Comparison of three mixed dentition analysis methods in orthodontic patients at AKUH.
Memon, S., & Fida, M. (2010) · PubMed · Cited by 20
Backward estimation of exposure to organochlorines using repeated measurements.
Karmaus, W. J. J., Fussman, C., Muttineni, J., & Zhu, X. (2004) · Environmental Health Perspectives · doi:10.1289/ehp.6761 · Cited by 20
Peak Expiratory Flow Rate Underestimates Severity of Airflow Obstruction in Acute Asthma
Choi, I. S., Koh, Y., & Lim, H. (2002) · The Korean Journal of Internal Medicine · doi:10.3904/kjim.2002.17.3.174 · Cited by 20
Mraović, B., Schwenk, E. S., & Epstein, R. H. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600308 · Cited by 20
Maggiulli, F., Hay, N., Mars, M., Worrell, E., Green, J. I. J., & Sommerlad, B. C. (2013) · The Cleft Palate-Craniofacial Journal · doi:10.1597/11-297 · Cited by 20
Measurement of cardiovascular state using attractor reconstruction analysis
Charlton, P. H., Camporota, L., Smith, J., Nandi, M., Christie, M. I., Aston, P. J., & Beale, R. (2015) · European Signal Processing Conference (EUSIPCO) · doi:10.1109/eusipco.2015.7362422 · Cited by 20
Weissland, T., Faupin, A., Borel, B., & Leprêtre, P. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00380 · Cited by 26
An index for diagnosing infant hip dysplasia using 3-D ultrasound: the acetabular contact angle
Mabee, M., Hareendranathan, A. R., Thompson, R. B., Dulai, S. K., & Jaremko, J. L. (2016) · Pediatric Radiology · doi:10.1007/s00247-016-3552-8 · Cited by 20
Koktzoglou, I., Walker, M. T., Meyer, J. R., Murphy, I., & Edelman, R. R. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0238-1 · Cited by 21
Cerda‐Kohler, H., Burgos, C., Ramírez‐Campillo, R., Valdés-Cerda, M., Martín, E. B.-S., Zapata-Gómez, D., Andrade, D. C., & Izquierdo, M. (2016) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001368 · Cited by 33
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.