Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 21,201–21,300 of 47,868
Tinsley, G. M. (2017) · Nutrition Research · doi:10.1016/j.nutres.2017.05.003 · Cited by 20
Tani, T., Song, Y., Yoshioka, T., Omae, T., Ishibazawa, A., Akïba, M., & Yoshida, A. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-21389 · Cited by 20
Montgomery, M. M., Marttinen, R. H. J., & Galpin, A. J. (2017) · International Journal of Kinesiology and Sports Science · doi:10.7575/aiac.ijkss.v.5n.4p.18 · Cited by 20
A 20 × 20 m repeated sprint field test replicates the demands of wheelchair rugby
Gee, C. M., Lacroix, M. A., & West, C. R. (2017) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2017.12.006 · Cited by 22
Fagundes, P. A. P., Chapon, R. D. C. B., Olsen, P. R., Schuster, A. K., Mattia, M. M. C., & Cunha‐Filho, J. S. (2017) · Reproductive Biology and Endocrinology · doi:10.1186/s12958-017-0314-x · Cited by 20
Tepedino, M., Potrubacz, M. I., Ciavarella, D., Masedu, F., Marchione, L., & Chimenti, C. (2018) · Journal of Clinical and Experimental Dentistry · doi:10.4317/jced.54585 · Cited by 20
Visual Impairment Screening Assessment (VISA) tool: pilot validation
Rowe, F. J., Hepworth, L. R., Hanna, K. L., & Howard, C. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-020562 · Cited by 20
Maeda, T., Hattori, K., Sumiyoshi, M., Kanazawa, H., & Ohnishi, Y. (2018) · Journal of Anesthesia · doi:10.1007/s00540-018-2491-y · Cited by 20
Reproducibility of domain-specific physical activity over two seasons in children
Aadland, E., Andersen, L. B., Ekelund, U., Anderssen, S. A., & Resaland, G. K. (2018) · BMC Public Health · doi:10.1186/s12889-018-5743-8 · Cited by 22
Vahia, D., Kelly, A. L., Knapman, H., & Williams, C. A. (2018) · Pediatric Exercise Science · doi:10.1123/pes.2018-0033 · Cited by 26
Spirometry reference equations for an adult Middle Eastern population
Al-Qerem, W. A., Hammad, A. M., Gassar, E. S., Al-Qirim, R. A., & Ling, J. (2019) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2019.1601560 · Cited by 20
van Hamersveld, K. T., de Mheen, P. J. M., Koster, L. A., Nelissen, R. G. H. H., Toksvig‐Larsen, S., & Kaptein, B. L. (2019) · Acta Orthopaedica · doi:10.1080/17453674.2019.1605692 · Cited by 20
Devaprakash, D., Lloyd, D. G., Barrett, R., Obst, S. J., Kennedy, B. A., Adams, K. L., Hunter, A. B., Vlahovich, N., Pease, D. L., & Pizzolato, C. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.07.679 · Cited by 23
Prediction of fetal macrosomia using two-dimensional and three-dimensional ultrasound
Mazzone, E., DALL’ASTA, A., Kiener, A. J. O., Carpano, M. G., Suprani, A., Ghi, T., & Frusca, T. (2019) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2019.10.003 · Cited by 22
Kappel, A., Mortensen, J. F., Nielsen, P. T., Odgaard, A., & Laursen, M. B. (2019) · The Knee · doi:10.1016/j.knee.2019.09.013 · Cited by 22
Yoo, M. H., Kim, H. J., Choi, I. H., Park, S., Kim, S. J., Park, H. K., Byun, D. W., & Suh, K. (2020) · BMC Cancer · doi:10.1186/s12885-019-6437-z · Cited by 21
A Novel Method for Evaluation of Ocular Torsion Angle by Optical Coherence Tomography
Yamadera, K., Ishikawa, H., Imai, A., Okamoto, M., Kimura, A., Mimura, O., & Gomi, F. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.3.27 · Cited by 20
Repeatability and Reproducibility of Pancreas Volume Measurements Using MRI
Williams, J. M., Hilmes, M. A., Archer, B. T., Dulaney, A., Du, L., Kang, H., Russell, W. E., Powers, A. C., Moore, D. J., & Virostko, J. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-61759-9 · Cited by 22
Milam, A. J., Ghoddoussi, F., Lucaj, J., Narreddy, S., Kumar, N. S., Reddy, V., Hakim, J., & Krishnan, S. H. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.03.048 · Cited by 20
Gait Variability Using Waist- and Ankle-Worn Inertial Measurement Units in Healthy Older Adults
Rantalainen, T., Karavirta, L., Pirkola, H., Rantanen, T., & Linnamo, V. (2020) · Sensors · doi:10.3390/s20102858 · Cited by 24
Seo, J. H., Jeon, H. W., Choi, J. S., & Sohn, J. R. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17197237 · Cited by 20
Borem, R., Walters, J., Madeline, A., Madeline, L. A., Gill, S. S., Easley, J. T., & Mercuri, J. J. (2020) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37117 · Cited by 26
Inertial Sensor Algorithms to Characterize Turning in Neurological Patients With Turn Hesitations
Shah, V. V., Curtze, C., Mancini, M., Carlson‐Kuhta, P., Nutt, J. G., Gomez, C. M., El‐Gohary, M., Horak, F. B., & McNames, J. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3037820 · Cited by 20
The Development and Accuracy of the THIM Wearable Device for Estimating Sleep and Wakefulness
Scott, H., Lovato, N., & Lack, L. C. (2021) · Nature and Science of Sleep · doi:10.2147/nss.s287048 · Cited by 20
Fekr, A. R., Li, Y., Gauvin, C., Wong, G., Cheng, W. K., Fernie, G. R., & Dutta, T. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18020405 · Cited by 20
Nielsen, A. M., Hartvigsen, J., Kongsted, A., Öberg, B. E., Enthoven, P., Abbott, A. D., & Lauridsen, H. H. (2021) · Health and Quality of Life Outcomes · doi:10.1186/s12955-021-01758-0 · Cited by 21
Hagedorn, J. M., Deer, T. R., Canzanello, N. C., Covington, S. M., Schroeder, D. R., Bendel, M. A., Moeschler, S. M., & Hooten, W. M. (2021) · Regional Anesthesia & Pain Medicine · doi:10.1136/rapm-2020-102238 · Cited by 20
Uloza, V., Stanienė, N. U. , Petrauskas, T., & Kregždytė, R. (2021) · Journal of Voice · doi:10.1016/j.jvoice.2021.01.025 · Cited by 27
McKinna, L. I. W., Cetinić, I., & Werdell, P. J. (2021) · Journal of Geophysical Research Oceans · doi:10.1029/2021jc017231 · Cited by 22
Rodríguez-Delgado, E., del Moral, R. G., Vargas, Á. C., Martín-López, J. I., & Colmenero, M. (2021) · Nursing in Critical Care · doi:10.1111/nicc.12622 · Cited by 20
Gantz, L., Shneor, E., & Doron, R. (2021) · Journal of Optometry · doi:10.1016/j.optom.2020.08.010 · Cited by 20
Costa, A., Konieczna, J., Reynés, B., Martín, M., Fiol, M., Palou, A., Romaguera, D., & Oliver, P. (2021) · Journal of Nutrition · doi:10.1093/jn/nxab117 · Cited by 23
Picciariello, A., Lobascio, P., Spazzafumo, L., Rinaldi, M., Dibra, R., Trigiante, G., Laforgia, R., Pezzolla, A., & Altomare, D. F. (2021) · Techniques in Coloproctology · doi:10.1007/s10151-021-02459-y · Cited by 20
Fiľo, P., & Janoušek, O. (2021) · Theoretical Issues in Ergonomics Science · doi:10.1080/1463922x.2021.1913535 · Cited by 39
Converting from the Montreal Cognitive Assessment to the Mini-Mental State Examination-2
Yang, H., Yim, D., & Park, M. H. (2021) · PLoS ONE · doi:10.1371/journal.pone.0254055 · Cited by 21
Clinical Utility of the 6-Item CTS, Boston-CTS, and Hand-Diagram for Carpal Tunnel Syndrome
Schulze, D. G., Nilsen, K. B., Killingmo, R. M., Zwart, J., & Grotle, M. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.683807 · Cited by 20
Rupf, R., Tsai, M., Thomas, S. G., & Klimstra, M. D. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110654 · Cited by 20
Mansfield, R. C., Kaza, N., Charalambous, A., Milne, A. C., Sathiyamurthy, S., & Banerjee, J. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005144 · Cited by 22
Oximetry neither to prescribe long-term oxygen therapy nor to screen for severe hypoxaemia
Lacasse, Y., Thériault, S., St-Pierre, B., Bernard, S., Sériès, F., Bernatchez, H. J., & Maltais, F. (2021) · ERJ Open Research · doi:10.1183/23120541.00272-2021 · Cited by 26
Odibo, A. O., Kayisli, U. A., Lu, Y., Kayisli, O. G., Schatz, F., Odibo, L., Chen, H., Bronsteen, R. A., & Lockwood, C. J. (2021) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.23760 · Cited by 20
Löppönen, A., Karavirta, L., Portegijs, E., Koivunen, K., Rantanen, T., Finni, T. J., Delecluse, C., Roie, E. V., & Rantalainen, T. (2021) · Sensors · doi:10.3390/s21186068 · Cited by 22
Liu, P., Jiang, D., Albert, M., Bauer, C. E., Caprihan, A., Gold, B. T., Greenberg, S. M., Helmer, K. G., Jann, K., Jicha, G. A., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118754 · Cited by 20
Finkelman, T., Furman‐Haran, E., Paz, R., & Tal, A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118810 · Cited by 22
Korchia, J., & Freeman, K. P. (2021) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/10406387211029247 · Cited by 22
Test-Retest Reliability of the Isometric Soleus Strength Test in Elite Male Academy Footballers
Rhodes, D., Jeffery, J., Brook-Sutton, D., & Alexander, J. (2022) · International Journal of Sports Physical Therapy · doi:10.26603/001c.31047 · Cited by 90
Sun, X., Xu, S., Hua, W., Tian, J., & Xu, Y. (2022) · Urban forestry & urban greening · doi:10.1016/j.ufug.2022.127553 · Cited by 20
Prediction of Myocardial Infarction From Patient Features With Machine Learning
Chen, Z., Shi, J., Pommier, T., Cottin, Y., Salomon, M., Decourselle, T., Lalande, A., & Couturier, R. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.754609 · Cited by 24
Reliability of muscle thickness and echo intensity measurements of the quadriceps: A novice examiner
Abiko, T., Ohmae, K., Murata, S., Shiraiwa, K., & Horie, J. (2022) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2022.03.004 · Cited by 20
Collaborative, C., Spiers, H. V. M., Kouli, O., Ahmed, W. U., Varley, R. J., Ahari, D., Argus, L., McLean, K. A., Kamarajah, S. K., Coe, P. O., et al. (2022) · BJS Open · doi:10.1093/bjsopen/zrac052 · Cited by 20
Bommineni, V. L., Erus, G., Doshi, J. J., Singh, A., Keenan, B. T., Schwab, R. J., Wiemken, A. S., & Davatzikos, C. A. (2022) · Academic Radiology · doi:10.1016/j.acra.2022.04.023 · Cited by 26
Lombardo, G., Signoriello, A., Pardo, A., Serpa-Romero, X. Z., Sierra, L. A. V., Tovar, L. L. A., Marincola, M., & Nocini, P. F. (2022) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.13103 · Cited by 23
Volumetric analysis of the piriform cortex in temporal lobe epilepsy
Iqbal, S., León-Rojas, J. E., Galovic, M., Vos, S. B., Hammers, A., de Tisi, J., Koepp, M. J., & Duncan, J. S. (2022) · Epilepsy Research · doi:10.1016/j.eplepsyres.2022.106971 · Cited by 22
Polish Translation and Validation of the Voice Handicap Index (VHI-30)
Miaśkiewicz, B., Gos, E., Dębińska, M., Panasiewicz, A., Kapustka, D., Nikiel, K., Włodarczyk, E. A., Domeracka-Kołodziej, A., Krasnodębska, P., & Szkiełkowska, A. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph191710738 · Cited by 23
Ritsche, P., Schmid, R., Franchi, M. V., & Faude, O. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.981862 · Cited by 25
York, E. N., Meijboom, R., Thrippleton, M. J., Bastin, M. E., Kampaite, A., White, N., Chandran, S., & Waldman, A. D. (2022) · NeuroImage Clinical · doi:10.1016/j.nicl.2022.103228 · Cited by 24
Braun, V., Stuppner, H., Risch, L., & Seger, C. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms232314691 · Cited by 23
Psychometric properties of the EQ-5D-5L compared with EQ-5D-3L in cancer patients in Iran
Moradi, N., Poder, T. G., Safari, H., Mojahedian, M. M., & Ameri, H. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.1052155 · Cited by 23
Wang, D., Liu, E., Liu, H., Jin, X., Niu, C., Gao, Y., & Su, X. (2023) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2022.1110684 · Cited by 20
Remote collection of physical performance measures for older people: a systematic review
Heslop, P., Hurst, C., Sayer, A. A., & Witham, M. D. (2023) · Age and Ageing · doi:10.1093/ageing/afac327 · Cited by 23
Malik, A., Baranger, J., Nguyen, M. B., Slorach, C., Hui, W., Lizardi, J. C. V., Venet, M., Friedberg, M. K., Mertens, L., & Villemain, O. (2023) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2023.02.012 · Cited by 20
Holder, T. M., Hooper, F. S. W., Yates, D., Tse, Z. T. H., Patil, S. B., Moussa, A., Batten, L., Radhakrishnan, V., Allison, M., Hewitt, C. E., et al. (2023) · Clinical Medicine · doi:10.7861/clinmed.2022-0252 · Cited by 25
Resende, L. M., Oliveira, L. S., & França, A. S. (2023) · Foods · doi:10.3390/foods12071488 · Cited by 20
Proença, M., Ambuehl, J., Bonnier, G., Meister, T. A., Valentin, J., Soria, R., Ferrario, D., Lemay, M., & Rexhaj, E. (2023) · Scientific Reports · doi:10.1038/s41598-023-33205-z · Cited by 21
Sagayama, H., Kondo, E., Tanabe, Y., Uchizawa, A., Evans, W. J., Shankaran, M., Nyangau, E., Hellerstein, M. K., Shiose, K., Yoshida, T., et al. (2023) · Journal of Nutrition · doi:10.1016/j.tjnut.2023.07.010 · Cited by 25
blandaltman: A command to create variants of Bland–Altman plots
Chatfield, M. D., Cole, T. J., de Vet, H. C. W., Marquart, L., & Farewell, D. M. (2023) · The Stata Journal Promoting communications on statistics and Stata · doi:10.1177/1536867x231196488 · Cited by 20
Reliability and Validity of the Portable KForce Plates for Measuring Countermovement Jump (CMJ)
Plakoutsis, G., Zapantis, D., Panagiotopoulou, E.-M., Paraskevopoulos, E., Moutzouri, M., Koumantakis, G. Α., & Παπανδρέου, Μ. (2023) · Applied Sciences · doi:10.3390/app132011200 · Cited by 28
Archer, H., Reine, S., Xia, S., Vazquez, L. C., Ashikyan, O., Pezeshk, P., Kohli, A., Xi, Y., Wells, J. E., Hummer, A., et al. (2023) · Skeletal Radiology · doi:10.1007/s00256-023-04502-5 · Cited by 20
Reliability of the Maximal Lactate Accumulation Rate in Rowers
Held, S., Rappelt, L., Brockherde, J., & Donath, L. (2023) · International Journal of Sports Medicine · doi:10.1055/a-2206-4959 · Cited by 20
Measuring handgrip strength in school children: inter-instrument reliability between Takei and Jamar
Trajković, N., Rančić, D., Ilić, T., Herodek, R., Korobeynikov, G., & Pekas, D. (2024) · Scientific Reports · doi:10.1038/s41598-024-51368-1 · Cited by 27
Nazir, M. S., Okafor, J., Murphy, T., Andrés, M. S., Ramalingham, S., Rosen, S. D., Chiribiri, A., Plein, S., Prasad, S., Mohiaddin, R. H., et al. (2024) · Radiology Cardiothoracic Imaging · doi:10.1148/ryct.230048 · Cited by 26
de Oliveira, G. B., Fernandes, L. V., Chen, X. S., Andrade, F. C. D., Costa, L. S., Vasques, A. C. J., & Corona, L. P. (2024) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2024.01.005 · Cited by 22
Zuo, J., Zhou, D., Zhang, L., Zhou, X., Gao, X., Hou, W., Wang, C., Jiang, P., & Wang, X. (2024) · Nutrition · doi:10.1016/j.nut.2024.112363 · Cited by 24
Multidimensional morphological analysis of live sperm based on multiple-target tracking
Yang, H. Y., Ma, M., Chen, X., Chen, G., Shen, Y., Zhao, L., Wang, J., Yan, F., Huang, D., Gao, H., et al. (2024) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2024.02.025 · Cited by 27
Video-Based Detection of Freezing of Gait in Daily Clinical Practice in Patients With Parkinsonism
Kondo, Y., Bando, K., Suzuki, I., Miyazaki, Y., Nishida, D., Hara, T., Kadone, H., & Suzuki, K. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3413055 · Cited by 24
Bouzid, A. I. H., Bui, S., Benlala, I., Berger, P., Hutt, A., Liberge, R., Habert, P., Gaubert, J., Baqué-Juston, M., Morel, B., et al. (2024) · European Radiology · doi:10.1007/s00330-024-11019-5 · Cited by 23
Xu, W., Chafi, H., Guo, B., Heymsfield, S. B., Murray, K. B., Zheng, J., & Jia, G. (2015) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2015.06.002 · Cited by 21
Sarris, I., Ohuma, E. O., Ioannou, C., Sande, J., Altman, D. G., & Papageorghiou, A. T. (2013) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.12410 · Cited by 20
Self-citationKilbride, L., Charlton, J., Aitken, G., Hill, G., Davison, R. R., & McKnight, J. A. (2011) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2011.03771.x · Cited by 23
Smart Sensing System for Combined Activity Classification and Estimation of Knee Range of Motion
Papi, E., Spulber, I., Kotti, M., Georgiou, P., & McGregor, A. H. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2444441 · Cited by 25
Nasal bone length: prenasal thickness ratio: a strong 2D ultrasound marker for Down syndrome
Szabó, A., Szili, K., Szabó, J., Sikovanyecz, J., Isaszegi, D., Horváth, E., & Szabó, J. (2014) · Prenatal Diagnosis · doi:10.1002/pd.4442 · Cited by 20
Inter- and Intra-Rater Reliability of the Visual Vertical in Subacute Stroke
Piscicelli, C., Barra, J., Davoine, P., Chrispin, A., Nadeau, S. M., & Pérennou, D. A. (2015) · Stroke · doi:10.1161/strokeaha.115.009610 · Cited by 25
Level of agreement between prehospital and emergency department vital signs in trauma patients
Dinh, M. M. Q., Oliver, M., Bein, K. J., Muecke, S., Carroll, T., Veillard, A., Gabbe, B. J., & Ivers, R. (2013) · Emergency Medicine Australasia · doi:10.1111/1742-6723.12126 · Cited by 20
Zhao, X., Zhao, W., Zhang, H., Li, J., Shu, Y., Li, S., Cai, L., Zhou, J., Li, Y., & Hu, R. (2013) · PubMed · doi:10.3275/8304 · Cited by 28
Mapping and direct valuation: do they give equivalent EQ-5D-5L index scores?
Luo, N., Cheung, Y. B., Ng, R. C. H., & Lee, C. F. (2015) · Health and Quality of Life Outcomes · doi:10.1186/s12955-015-0361-y · Cited by 22
Bashir, A., & Gropler, R. J. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3103 · Cited by 20
The impact of acute illness on HbA1c determination of undiagnosed diabetes
Thakker, U., Ellman, T., Magleby, R., Graff, K., Kelson, J. R., & Silverman, R. A. (2012) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2315 · Cited by 22
Pfeiffer, C. M., Smith, S. J., Miller, D. T., & Gunter, E. W. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.12.2236 · Cited by 20
Itenov, T. S., Bangert, K., Christensen, P. H., Jensen, J. S., Bestle, M. H., & on behalf of the Procalcitonin and Survival Study (PASS)-study group (2014) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.21662 · Cited by 20
Dried-Serum Spot Assay for Folate
O’Broin, S., & Gunter, E. W. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.7.1128 · Cited by 20
Teshima, D., Maiguma, T., Kaji, H., Otsubo, K., Kitagawa, N., Okabe, Y., Sugitani, A., Tanaka, M., & Oishi, R. (2008) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1111/j.1365-2710.2008.00896.x · Cited by 20
Meijerink, M. R., van Waesberghe, J. H. T. M., van Schaik, C., Boven, E., van der Veldt, A. A. M., van den Tol, P., Meijer, S., & van Kuijk, C. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.06.015 · Cited by 21
Manual versus automatic bladder wall thickness measurements: a method comparison study
Oelke, M., Mamoulakis, C., Ubbink, D. T., de la Rosette, J. J. M. C. H., & Wijkstra, H. (2009) · World Journal of Urology · doi:10.1007/s00345-009-0392-2 · Cited by 20
Timmins, L. H., Suever, J. D., Eshtehardi, P., McDaniel, M. C., Oshinski, J. N., Samady, H., & Giddens, D. P. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2269275 · Cited by 20
Royse, C. F., Connelly, K. A., MacLaren, G., & Royse, A. G. (2006) · Anaesthesia · doi:10.1111/j.1365-2044.2006.04911.x · Cited by 20
Harrison, M. J., Boonen, A. E. R. C. H., Tugwell, P., & Symmons, D. P. M. (2009) · Quality of Life Research · doi:10.1007/s11136-009-9546-3 · Cited by 20
Ehehalt, S., Kehrer, M., Goelz, R., Poets, C. F., & Schöning, M. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.10.002 · Cited by 20
Leite, C. E., Petersen, G. O., Lunardelli, A., & Thiesen, F. V. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2009.105 · Cited by 20
Freeth, D., Sandall, J., Allan, T. F., Warburton, F. G., Berridge, E., Mackintosh, N. J., Rogers, M., & Abbott, S. (2012) · Health Technology Assessment · doi:10.3310/hta16250 · Cited by 28
Kennelly, M., Farah, N., Hogan, J. L., Reilly, A., Turner, M. J., & Stuart, B. (2012) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.9076 · Cited by 24
Pengo, V., Biasiolo, A., & Pegoraro, C. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)02069-0 · Cited by 20
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.