STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 23,301–23,400 of 47,868
Quantitative gated SPECT myocardial perfusion imaging with 201Tl: an assessment of the limitations
WRIGHT, G. A., McDade, M., Keeble, W., MARTIN, W., & Hutton, I. (2000) · Nuclear Medicine Communications · doi:10.1097/00006231-200012000-00008 · Cited by 18
Nordmann, A. J., Frach, B., Walker, T., Martina, B., & Battegay, E. (2000) · Blood Pressure · doi:10.1080/080370500439083 · Cited by 22
Koide, Y., Yotsukura, M., Tajino, K., Yoshino, H., & Ishikawa, K. (1999) · Clinical Cardiology · doi:10.1002/clc.4960221010 · Cited by 21
Friedman, L. S., Lukyanova, O. M., Kundiev, Y., Shkiryak-Nizhnyk, Z. A., Chislovska, N. V., Mucha, A. P., Звінчук, О., Oliynyk, I., & Hryhorczuk, D. O. (2005) · Environmental Research · doi:10.1016/j.envres.2004.12.006 · Cited by 18
Rué, M., Valero, C., Quintana, S., Artigas, A., & Álvarez, M. (2000) · Intensive Care Medicine · doi:10.1007/s001340051151 · Cited by 18
Marven, S. S., Hampshire, A., Smallwood, R. H., Brown, B. H., & Primhak, R. A. (1996) · Physiological Measurement · doi:10.1088/0967-3334/17/4a/025 · Cited by 18
Blumberg, F. C., Pfeifer, M., Holmer, S. R., Kromer, E. P., Riegger, G. A. J., & Eisner, D. (1998) · CHEST Journal · doi:10.1378/chest.114.1.94 · Cited by 18
Antonicelli, R., Savonitto, S., Gambini, C., Tomassini, P. F., Sardina, M., & Paciaroni, E. (1991) · Angiology · doi:10.1177/000331979104200807 · Cited by 18
Fitch, J. C. K., Geary, K., Mirto, G. P., Byrne, D. W., & Hines, R. L. (1999) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(99)90174-x · Cited by 18
Reproducibility of color Doppler flow quantification of aortic regurgitation
Willems, T. P., Steverberg, E. W., van Herwerden, L. A., Kleyburg-Linkers, V. E., Schiks-Berghout, M., Taams, M. A., Roelandt, J. R. T. C., & Bos, E. (1997) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(97)80006-5 · Cited by 18
Rebergen, S. A., van der Wall, E. E., Helbing, W. A., Roos, A., & van Voorthuisen, A. E. (1996) · International journal of cardiac imaging · doi:10.1007/bf01806217 · Cited by 18
Sladkevicius, P., & Valentin, L. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00118-w · Cited by 18
Bogaard, H. J., Hamersma, W., Horsch, J. L. M. I., Woltjer, H. H., Postmus, P. E., & VRIES, P. M. J. M. D. (1997) · Physiological Measurement · doi:10.1088/0967-3334/18/4/006 · Cited by 18
Blumberg, F. C., Pfeifer, M., Holmer, S. R., Kromer, E. P., Riegger, G. A. J., & Elsner, D. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00100-8 · Cited by 18
Markstaller, K., Kauczor, H. ‐., Puderbach, M., Mayer, E., Viallon, M., Gast, K., Weiler, N., THELEN, M., & Eberle, B. (2002) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2002.460715.x · Cited by 18
The Use of a Hemocue Blood Glucose Analyser in a Neonatal Unit
Leonard, M., Chessall, M., & Manning, D. (1997) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329703400311 · Cited by 18
Soto-Yarritu, P. L., Díez‐Masa, J. C., de Frutos, M., & Cifuentes, A. (2002) · Journal of Separation Science · doi:10.1002/1615-9314(20021101)25:15/17<1087::aid-jssc1087>3.0.co;2-a · Cited by 33
Cuddihy, S. L., ANDERSON, N. G., Wells, J. E., & Darlow, B. A. (1999) · Pediatric Radiology · doi:10.1007/s002470050655 · Cited by 18
Noninvasive Cardiac Index Monitoring in Gunshot Wound Victims
BISHOP, M. H., Shoemaker, W. C., Shuleshko, J., & Wo, C. C. J. (1996) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1996.tb03490.x · Cited by 18
Lam, A. K. C., Chan, R., Woo, G. C., Pang, P. C. K., & Chiu, R. (2002) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2002.00074.x · Cited by 18
Endothelial Colony Forming Capacity is Related to C-Reactive Protein Levels in Healthy Subjects
Ciulla, M. M., Giorgetti, A., Silvestris, I., Cortiana, M., Montelatici, E., Paliotti, R., Annoni, G. A., Fiore, A. M., Giordano, R., MARCO, F. D., et al. (2006) · Current Neurovascular Research · doi:10.2174/156720206776875876 · Cited by 18
Quality assessment of blood glucose testing in general practitioners’ offices improves quality
Stahl, M., Brandslund, I., Iversen, S., & Filtenborg, J. A. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.10.1926 · Cited by 18
Haugen, B. O. (2000) · European Journal of Echocardiography · doi:10.1053/euje.2000.0044 · Cited by 18
Florea, V. G., Henein, M. Y., Anker, S. D., Francis, D. P., Gibson, D. G., & Coats, A. J. S. (2000) · American Heart Journal · doi:10.1016/s0002-8703(00)90025-5 · Cited by 18
de Grauw, W. J. C., van de Lisdonk, E. H., van den Hoogen, H. J. M., van Gerwen, W. H. E. M., van den Bosch, W. J. H. M., Willems, J., & van Weel, C. (1995) · Diabetic Medicine · doi:10.1111/j.1464-5491.1995.tb00565.x · Cited by 18
Woodrow, G., Oldroyd, B., Wright, A., Coward, W. A., Truscott, J. G., Turney, J. H., Brownjohn, A. M., & Smith, M. A. (2003) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/18.2.384 · Cited by 22
U‐King‐Im, J. M., Graves, M. J., Cross, J., Higgins, N. J., Wat, J., Trivedi, R. A., Tang, T. Y., Howarth, S. P. S., Kirkpatrick, P. J., Antoun, N. M., et al. (2007) · Radiology · doi:10.1148/radiol.2441060749 · Cited by 18
Hedström, E., Palmer, J. C., Ugander, M., & Arheden, H. (2004) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2004.00579.x · Cited by 18
Measurement of carbon monoxide transfer and lung volume in ventilated subjects
MACNAUGHTON, P. D., Morgan, C., Denison, D., & Evans, T. (1993) · European Respiratory Journal · doi:10.1183/09031936.93.06020231 · Cited by 18
Rødevand, O., Bjørnerheim, R., Aakhus, S., & KJEKSHUS, J. K. (1998) · International journal of cardiac imaging · doi:10.1023/a:1005820303511 · Cited by 18
Yamaji, S., Demura, S., Noda, M., Nagasawa, Y., Nakada, M., & Kitabayashi, T. (2001) · Equilibrium Research · doi:10.3757/jser.60.217 · Cited by 18
Comparison of in-vivo body composition using two Lunar dual-energy X-ray absorptiometers
Oldroyd, B., Truscott, J., Woodrow, G., Milner, R., Stewart, S., Smith, A. H., Westmacott, C. F., & Smith, M. (1998) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600537 · Cited by 18
Tonometry in the general practice setting (I)
Christoffersen, T., Fors, T., Ringberg, U., & Holtedahl, K. A. (1993) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1993.tb04970.x · Cited by 18
A comparison of tests to determine acuity deficits in children with amblyopia
Geer, I. (1996) · Ophthalmic and Physiological Optics · doi:10.1016/0275-5408(96)00009-9 · Cited by 18
Samstad, S. O., Torp, H. G., Matre, K., Rossvoll, O., Segadal, L., & Piene, H. (1990) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(14)80361-1 · Cited by 18
Correction of the slope–intercept method for the measurement of glomerular filtration rate
Blake, G. M., Barnfield, M. C., Burniston, M. T., Fleming, J. S., Cosgriff, P. S., & Siddique, M. M. (2014) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000192 · Cited by 18
Index of glucose effectiveness derived from oral glucose tolerance test
Nagasaka, S., Kusaka, I., Yamashita, K., Funase, Y., Yamauchi, K., Katakura, M., Ishibashi, S., & Aizawa, T. (2012) · Acta Diabetologica · doi:10.1007/s00592-012-0417-y · Cited by 18
Mundigler, G., Zehetgruber, M., Christ, G., & Siostrzonek, P. (1997) · Clinical Cardiology · doi:10.1002/clc.4960200308 · Cited by 18
Mehta, S. K., Pierson, D. L., Cooley, H., Dubow, R., & Lugg, D. (2000) · Journal of Medical Virology · doi:10.1002/(sici)1096-9071(200006)61:2<235::aid-jmv10>3.0.co;2-4 · Cited by 132
Hilson, A. J. W. (2004) · Radiology · doi:10.1148/radiol.2312031472 · Cited by 18
(1995) · Critical Care Medicine · doi:10.1097/00003246-199510000-00022 · Cited by 18
Erythrocyte Sedimentation Rate (ESR)
Jou, J. M. (2012) · Wiley eBooks · doi:10.1002/9781444398595.ch49 · Cited by 18
Heat strain, hydration status, and symptoms of heat illness in surface mine workers
Hunt, A. P. (2011) · Faculty of Health; Institute of Health and Biomedical Innovation · Cited by 32
de Vries, G. E., van der Wal, H. H., Kerstjens, H. A. M., van Deursen, V. M., Stegenga, B., van Veldhuisen, D. J., van der Hoeven, J. H., van der Meer, P., & Wijkstra, P. J. (2015) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2015.06.009 · Cited by 17
Validation of a free software for unsupervised assessment of abdominal fat in MRI
Maddalo, M., Zorza, I., Zubani, S., Nocivelli, G., Calandra, G., Soldini, P., Mascaro, L., & Maroldi, R. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.04.002 · Cited by 17
Jendrike, N., Baumstark, A., Pleus, S., Liebing, C., Beer, A., Flacke, F., Haug, C., & Freckmann, G. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0391 · Cited by 17
Reproducibility of Sagittal Pelvic Tilt Measurements in Normal Subjects Using Digital Inclinometry
Prushansky, T., Ezra, N., Kurse, N., Man, L., & Schneiderman, Y. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.01.015 · Cited by 17
Wen, F.-H., Chen, J.-S., Chou, W.-C., Chang, W.-C., Hsieh, C.-H., & Tang, S. T. (2019) · Journal of Pain and Symptom Management · doi:10.1016/j.jpainsymman.2019.04.010 · Cited by 17
Marín‐Jiménez, N., Sánchez‐Parente, S., Expósito-Carrillo, P., Jiménez-Iglesias, J., Álvarez‐Gallardo, I. C., Cuenca‐García, M., & Castro‐Piñero, J. (2023) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2023.03.005 · Cited by 20
Pinnelli, M., Presti, D. L., Silvestri, S., Setola, R., Schena, E., & Massaroni, C. (2024) · Sensors · doi:10.3390/s24175815 · Cited by 17
Improving Vital Signs Monitoring in Real-World Environments With W-Band Phased-Array Radars
Antolinos, E., & Grajal, J. (2025) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2025.3544958 · Cited by 18
Determining the Variability Associated with Visual Acuity and Refractive Error Measurements
van der Zee, C., Muijzer, M. B., Claessens, J. L. J., & Wisse, R. P. L. (2025) · Ophthalmology · doi:10.1016/j.ophtha.2025.04.021 · Cited by 17
Reis, M., Teixeira, M., Carvão, C., & Martins, A. C. (2025) · Geriatrics · doi:10.3390/geriatrics10030062 · Cited by 22
Vanderschueren, E., Laleman, W., Bonne, L., Maleux, G. A., Wagner, D. R., Yeh, C., Calvo, A., Sendino, O., Ginés, À., Baiges, A., et al. (2025) · JHEP Reports · doi:10.1016/j.jhepr.2025.101466 · Cited by 33
Yuen, S. K. K., Chen, Z., Yuen, S., Liu, A. Q., Leung, S. C. H., Ko, I. C., Chan, C.-K., Somani, B. K., Herrmann, T., Jung, H., et al. (2025) · World Journal of Urology · doi:10.1007/s00345-025-05761-8 · Cited by 17
Statistical Analysis and Reporting of Cardiac Output Method Comparison Studies (COMPARE) Statement
Saugel, B., Hapfelmeier, A., Flick, M., Rinehart, J. B., Thiele, R. H., Vistisen, S. T., Bartels, K., Cannesson, M. P., Cecconi, M., Chew, M. S., et al. (2025) · Anesthesiology · doi:10.1097/aln.0000000000005559 · Cited by 21
The accuracy of Apple Watch measurements: a living systematic review and meta-analysis
Lambe, R., Baldwin, M., O’Grady, B., Schumann, M., Caulfield, B., & Doherty, C. (2026) · npj Digital Medicine · doi:10.1038/s41746-025-02238-1 · Cited by 24
Guzman, D. S.-M., Mitchell, M. A., & Acierno, M. J. (2011) · Journal of Herpetological Medicine and Surgery · doi:10.5818/1529-9651-21.1.16 · Cited by 17
Taylor, S. A., Slater, A., Honeyfield, L., Burling, D. N., & Halligan, S. (2006) · Academic Radiology · doi:10.1016/j.acra.2006.03.018 · Cited by 17
Validação Concorrente de Escores de Enfermagem (NEMS e TISS-28) em terapia intensiva pediátrica
Canabarro, S. T., Velozo, K. D. S., Eidt, O. R., Piva, J. P., & Garcia, P. C. R. (2013) · Acta Paulista de Enfermagem · doi:10.1590/s0103-21002013000200004 · Cited by 12
Eid, K., Krughoff, K., Stoimenova, D., Smith, D. T., Phillips, J. M., O’Donnell, C. I., & Barqawi, A. B. (2013) · Urology · doi:10.1016/j.urology.2013.08.039 · Cited by 17
Donoghue, D. O., & Kennedy, N. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2307 · Cited by 17
Kober, D., Trepte, C. J. C., Petzoldt, M., Nitzschke, R., Herich, L., Reuter, D. A., & Haas, S. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9478-x · Cited by 17
A New Outlier Identification Test for Method Comparison Studies Based on Robust Regression
Rauch, G., Geistanger, A., & Timm, J. (2010) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543401003650275 · Cited by 17
Davison, G., & Jones, A. W. (2014) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2014-0396 · Cited by 19
Hybrid Measurement to Achieve Satisfactory Precision in Perioperative Cardiac Output Monitoring
Peyton, P. J. (2014) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1404200311 · Cited by 17
Vajrabhaya, L.-O., & Korsuwannawong, S. (2016) · European Journal of Dentistry · doi:10.4103/1305-7456.175701 · Cited by 23
Intraocular Pressure Measurements After Descemet Membrane Endothelial Keratoplasty
Maier, A.-K. B., Gundlach, E., Pahlitzsch, M., Gonnermann, J., Corkhill, C., Bertelmann, E., Joussen, A. M., Klamann, M. K. J., & Torun, N. (2016) · Journal of Glaucoma · doi:10.1097/ijg.0000000000000593 · Cited by 18
Cohen, J. G., Kim, H., Park, S. B., van Ginneken, B., Ferretti, G., Lee, C. H., Goo, J. M., & Park, C. M. (2017) · European Radiology · doi:10.1007/s00330-016-4716-5 · Cited by 17
Cox, P. D., Frengopoulos, C., Hunter, S. W., Sealy, C., Deathe, A. B., & Payne, M. W. C. (2017) · Physiotherapy Canada · doi:10.3138/ptc.2016-24 · Cited by 20
Scores TISS-28 versus NEMS to size the nursing team in a pediatric intensive care unit
Velozo, K. D. S., Garcia, P. C. R., Piva, J. P., Fiori, H. H., Cabral, D. D., Einloft, P. R., Bruno, F., Tonial, C. T., Costa, C. A. D., & Canabarro, S. T. (2017) · Einstein (São Paulo) · doi:10.1590/s1679-45082017ao4028 · Cited by 17
Comparison of EQ-5D and SF-36 in untreated patients with symptoms of intermittent claudication
Vaidya, A., Kleinegris, M., Severens, J. L., Ramaekers, B. L. T., ten Cate‐Hoek, A. J., Cate, H. T., & Joore, M. A. (2018) · Journal of Comparative Effectiveness Research · doi:10.2217/cer-2017-0029 · Cited by 18
Robust Analysis of PM2.5 Concentration Measurements in the Ecuadorian Park La Carolina
Hernández, W., Méndez, A., Díaz-Márquez, A. M., & Žalakevičiūtė, R. (2019) · Sensors · doi:10.3390/s19214648 · Cited by 18
Tingulstad, A., Munk, R., Grotle, M., Vigdal, Ø. N., Storheim, K., & Langhammer, B. (2019) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-019-2910-8 · Cited by 18
Hayes‐Gill, B., Martin, T. R. P., Liu, C., & Cohen, W. R. (2019) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13760 · Cited by 17
Mösch, M., Reese, S., Weber, K., Hartmann, K., & Dorsch, R. (2019) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638719896785 · Cited by 17
Validation of the oscillometric blood pressure monitor Vet20 SunTech in anesthetized healthy cats
Cremer, J., da Cunha, A. F., Aulakh, K. S., Liu, C., & Acierno, M. J. (2020) · Veterinary Anaesthesia and Analgesia · doi:10.1016/j.vaa.2019.12.007 · Cited by 18
Test–Retest Reliability and Temporal Agreement of Direct and Indirect Sexual Interest Measures
Welsch, R., Schmidt, A. F., Turner, D., & Rettenberger, M. (2020) · Sexual Abuse · doi:10.1177/1079063220904354 · Cited by 20
A Portable Smartphone-linked Device for Direct, Rapid and Chemical-Free Hemoglobin Assay
Lee, J., Song, J., Choi, J., Kim, S., Kim, U., Nguyen, V.-T., Lee, J. S., & Joo, C. (2020) · Scientific Reports · doi:10.1038/s41598-020-65607-8 · Cited by 17
Halder, A., Adhikari, A., Ghosh, R., Singh, S., Banerjee, A., Ghosh, N., Bhattacharya, A. M., Mandal, S., Chakrabarti, P., Bhattacharyya, D., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-67981-9 · Cited by 17
Teixeira, L. F., Diz, J. B. M., da Silva, S. L. A., Viana, J. U., Dias, J. M. D., Pereira, L. S. M., & Dias, R. C. (2020) · Sao Paulo Medical Journal · doi:10.1590/1516-3180.2019.0542.r2.16042020 · Cited by 17
Lourenço, B. H., Lima, D. L., Vivanco, E., Fernandes, R. D. B., Duarte, M., Neves, P. A. R., Castro, M. C., Cardoso, M. A., & on behalf of the MINA-Brazil Study Group (2020) · PLoS ONE · doi:10.1371/journal.pone.0236055 · Cited by 19
Makaram, N. S., Lee, T., MacDonald, D. J., & Clement, N. D. (2020) · The Knee · doi:10.1016/j.knee.2020.07.098 · Cited by 17
Cheng, K. S., Pan, R., Pan, H., Li, B., Meena, S. S., Xing, H., Ng, Y. J., Qin, K., Liao, X., Kosgei, B. K., et al. (2020) · Theranostics · doi:10.7150/thno.44053 · Cited by 18
Chou, C. A., Toedebusch, C. D., Redrick, T., Freund, D., McLeland, J., Morris, J. C., Holtzman, D. M., & Lucey, B. P. (2020) · SLEEP Advances · doi:10.1093/sleepadvances/zpaa006 · Cited by 21
Davis, T. L., Dirks, B., Carnero, E. Á., Corbin, K. D., Krakoff, J., Parrington, S., Lee, D., Smith, S. R., Rittmann, B. E., Krajmalnik‐Brown, R., et al. (2020) · Journal of Nutrition · doi:10.1093/jn/nxaa321 · Cited by 19
Wang, T., Tang, J., Xie, S., He, X., Wang, Y., Liu, T., Jia, M., & Li, K. (2021) · Spinal Cord · doi:10.1038/s41393-020-00601-5 · Cited by 18
Espada, M. C., Alves, F., Curto, D., Ferreira, C. C., Santos, F., Filho, D. M. P., & Reis, J. F. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18020477 · Cited by 21
Parametric and nonparametric improvements in Bland and Altman's assessment of agreement method
Chen, L., & Kao, C.-L. M. (2021) · Statistics in Medicine · doi:10.1002/sim.8895 · Cited by 17
Kawaguchi, M., Kidokoro, H., Ito, R., Shiraki, A., Suzuki, T., Maki, Y., Tanaka, M., Sakaguchi, Y., Yamamoto, H., Takahashi, Y., et al. (2021) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2021.03.004 · Cited by 17
de Castro, E. D., Barbosa, J., Mesquita, A. M., Caires, A. L., Ribeiro, L. V. P. T., Cernadas, J. R., & Baiardini, I. (2021) · Health and Quality of Life Outcomes · doi:10.1186/s12955-021-01749-1 · Cited by 17
Teimouri, A., Afshar, M. J. A., Mohtasebi, S., Azami, S. J., Alimi, R., & Keshavarz, H. (2021) · Journal of Clinical Microbiology · doi:10.1128/jcm.00416-21 · Cited by 17
Dual Hip DXA. Is it Time to Change Standard Protocol?
Chen, W., Khan, Z., Freund, J., & POCOCK, N. A. (2021) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2021.07.006 · Cited by 17
Sánchez‐González, M. C., García-Oliver, R., Sánchez‐González, J., Bautista‐Llamas, M., Jiménez‐Rejano, J., & De‐Hita‐Cantalejo, C. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18157876 · Cited by 17
Rivadulla, A. R., Chen, X., Weir, G., Cazzola, D., Trewartha, G., Hamill, J., & Preatoni, E. (2021) · PLoS ONE · doi:10.1371/journal.pone.0248608 · Cited by 19
Du, X., Xu, X., Liu, H., & Li, S. (2021) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2021.101971 · Cited by 19
An Italian Case Study for Assessing Nutrient Intake through Nutrition-Related Mobile Apps
Mistura, L., Azcarraga, F. J. C., D’Addezio, L., Martone, D., & Turrini, A. (2021) · Nutrients · doi:10.3390/nu13093073 · Cited by 17
Physical activity monitoring during hospital stay: a validation study
Valkenet, K., Bor, P., Reijneveld, E. A. E., Veenhof, C., & Dronkers, J. (2022) · Disability and Rehabilitation · doi:10.1080/09638288.2022.2034995 · Cited by 17
Validity of a portable spirometer in the communities of China
Xiao, S., Wu, F., Wang, Z., Chen, J., Yang, H., Zheng, Y., Deng, Z., Peng, J., Wen, X. B., Huang, P., et al. (2022) · BMC Pulmonary Medicine · doi:10.1186/s12890-022-01872-9 · Cited by 17
Potter, A. W., Tharion, W. J., Holden, L. D., Pazmino, A., Looney, D. P., & Friedl, K. E. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.868627 · Cited by 17
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.