STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 24,701–24,800 of 47,868
Raaijmakers, E., Faes, T. J. C., Kunst, P. W. A., Bakker, J., Rommes, J. H., Goovaerts, H. G., & Heethaar, R. M. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/4/004 · Cited by 16
The Impact of Test Medium on Use of Visual Analogue Scales
Woods, C. A., & Cumming, B. (2008) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0b013e3181909b03 · Cited by 17
Reliability of a cycling time trial in a glycogen-depleted state
Currell, K., Jentjens, R. L. P. G., & Jeukendrup, A. E. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0305-7 · Cited by 24
Lamoureux, E. L., Lo, K., Ferraro, J. G., Constantinou, M., Keeffe, J. E., ̈ller, A. M., & Taylor, H. R. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0936 · Cited by 16
Christiansen, M. S., Blirup-Jensen, S., Foged, L., Larsen, M., & Magid, E. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.237 · Cited by 16
Tang, W., Modi, N., & Clark, P. (1993) · Archives of Disease in Childhood · doi:10.1136/adc.69.1_spec_no.28 · Cited by 18
Jothybasu, K., Bahl, A., Subramani, V., Rath, G., Sharma, D., & Julka, P. (2009) · Journal of Medical Physics · doi:10.4103/0971-6203.51932 · Cited by 16
Comparison of Anterior Chamber Depth Measurements Conducted with Pentacam HR ® and IOLMaster ®
Németh, G., Hassan, Z., Módis, L., Szalai, E., Katona, K., & Berta, A. (2011) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/15428877-20110210-03 · Cited by 16
Hayano, J., Jiang, W., WAUGH, R. A., O’Connor, C. M., Frid, D. J., & Blumenthal, J. A. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70075-9 · Cited by 19
Bui, B. V., Fortune, B. A., Cull, G. A., Wang, L., & Cioffi, G. A. (2003) · Experimental Eye Research · doi:10.1016/s0014-4835(03)00195-7 · Cited by 16
Bedside Prediction of Airway Length in Adults and Children
Lee, B.-J., Yi, J.-W., Chung, J. Y., Kim, D.-O., & Kang, J.-M. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181af6496 · Cited by 16
Wong, F. Y., Barfield, C. P., Campbell, L., Brodecky, V., & WALKER, A. M. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600507 · Cited by 16
Body composition in Prader‐Willi syndrome: assessment and effects of growth hormone administration
Davies, P. (1999) · Acta Paediatrica · doi:10.1111/j.1651-2227.1999.tb14415.x · Cited by 16
Adachi, I., Gaemperli, O., Valenta, I., Schepis, T., Siegrist, P. T., Treyer, V., Burger, C., Morita, K., & Kaufmann, P. A. (2007) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2007.05.012 · Cited by 18
Jeltsch, M., Ranft, S., Klass, O., Aschoff, A. J., & Hoffmann, M. H. K. (2008) · Acta Radiologica · doi:10.1080/02841850801998847 · Cited by 16
RADIATION EXPOSURE FROM DIAGNOSTIC IMAGING: AGREEMENT BETWEEN SELF-REPORT AND MEDICAL RECORDS
Pogoda, J. M., & Preston‐Martin, S. (2002) · Health Physics · doi:10.1097/00004032-200212000-00019 · Cited by 17
Henes, F. O., Groth, M., Kramer, H., Schaefer, C., Regier, M., Derlin, T., Adam, G., & Bannas, P. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.09.015 · Cited by 16
Use of pulse oximetry for blood pressure measurement after cardiac surgery
Movius, A. J., Bratton, S. L., & Sorensen, G. K. (1998) · Archives of Disease in Childhood · doi:10.1136/adc.78.5.457 · Cited by 16
Searle, N. R., Perrault, J., Ste-Marie, H., & Dupont, C. (1993) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03009640 · Cited by 16
Chen, H.-S., Kuo, B. I., Hwu, C., Shih, K., Kwok, C., & Ho, L.-T. (1998) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(98)00077-1 · Cited by 18
An assessment of tissue harmonic versus fundamental imaging modes for echocardiographic measurements
Graham, R., Gallas, W., Gelman, J. S., Donelan, L., & Peverill, R. E. (2001) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2001.113816 · Cited by 16
Abdominal surgery alters the calibration of bioimpedance cardiac output measurement
Critchley, L. A. H., Leung, D. H. Y., & Short, T. G. (1996) · International journal of clinical monitoring and computing · doi:10.1007/bf02918206 · Cited by 16
Houlind, K. C., Schroeder, A. P., Egeblad, H., & Pedersen, E. M. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00018-1 · Cited by 16
Zinserling, J., Wrigge, H., Neumann, P., Muders, T., Magnusson, A., Hedenstierna, G., & Putensen, C. (2005) · CHEST Journal · doi:10.1378/chest.128.4.2963 · Cited by 16
Lorsomradee, S., Lorsomradee, S., Cromheecke, S., & Hert, S. G. D. (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05194.x · Cited by 16
A Pilot Study of Left Tracheal Pulse Oximetry
Brimacombe, J. R., KELLER, C., & Margreiter, J. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200010000-00043 · Cited by 18
Evolution of Individual Renal Function in Children with Unilateral Complex Renal Duplication
Ismaïli, K., Hall, M., Ham, H., & Piepsz, A. (2005) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2005.03.048 · Cited by 16
Use of a video time display in determining general gait measures
Stillman, B. C., & McMeeken, J. M. (1996) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(14)60388-3 · Cited by 16
Holland, M. R., Gibson, A. A., Kirschner, C. A., Hicks, D., Ludomirsky, A., & Singh, G. K. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.028 · Cited by 16
Performance in Specular Reflection and Slit‐Imaging Corneal Topography
Braaf, B., Dubbelman, M., van der Heijde, R. G. L., & Sicam, V. A. D. P. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e31819fa6f9 · Cited by 16
Serum S100B levels after meningioma surgery: A comparison of two laboratory assays
Einav, S., Itshayek, E., Kark, J. D., Ovadia, H., Weiniger, C. F., & Shoshan, Y. (2008) · BMC Clinical Pathology · doi:10.1186/1472-6890-8-9 · Cited by 16
Prediction of early-onset asthma in genetically at-risk children
Mrazek, D. A., Klinnert, M., Mrazek, P. J., Brower, A., McCormick, D., Rubin, B., Ikle, D., Kastner, W., Larsen, G., Harbeck, R., et al. (1999) · Pediatric Pulmonology · doi:10.1002/(sici)1099-0496(199902)27:2<85::aid-ppul4>3.0.co;2-b · Cited by 92
Martín, J. M., del Campo, V. L., Román, M. L., Horrillo, J. M. G.-V., & Navarrete, J. S. G. (2013) · Journal of Sports Sciences · doi:10.1080/02640414.2013.797592 · Cited by 16
Xun, L., Wu, X., Li, N., & Tan-qi, L. (2010) · International Conference on Computer Application and System Modeling · doi:10.1109/iccasm.2010.5622616 · Cited by 16
Leg blood flow measurements using venous occlusion plethysmography during head-up tilt
Kooijman, M., Poelkens, F., Rongen, G. A. P. J. M., Smits, P., & Hopman, M. T. E. (2007) · Clinical Autonomic Research · doi:10.1007/s10286-007-0402-7 · Cited by 20
Blaasaas, K. G., & Tynes, T. (2002) · Bioelectromagnetics · doi:10.1002/bem.10024 · Cited by 16
López-Jaramillo, P. A., Díaz‐Martínez, L. A., Pardo, A., Parra, G., Jaimes, H., & Chaudhuri, G. (2004) · Fertility and Sterility · doi:10.1016/j.fertnstert.2004.05.083 · Cited by 17
Oksanen, A., YLINEN, J. J., Pöyhönen, T., Anttila, P., Laimi, K., Hiekkanen, H., & Salminen, J. J. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.04.009 · Cited by 16
Dressed or undressed? How to measure children's body weight in overweight surveillance?
Censi, L., Spinelli, A., Roccaldo, R., Bevilacqua, N., Lamberti, A., Angelini, V., Nardone, P., & Baglìo, G. (2013) · Public Health Nutrition · doi:10.1017/s1368980013003030 · Cited by 16
Hofman, C. S., Melis, R. J. F., & Donders, A. R. T. (2015) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2015.02.015 · Cited by 16
The practical near acuity chart (PNAC) and prediction of visual ability at near
Wolffsohn, J. S., & Cochrane, A. L. (2000) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(99)00035-6 · Cited by 16
Alexander, K., del Castillo, J. R. E., Ybarra, N., Morin, V., Gauvin, D. V., Authier, S., Vinay, P., & Troncy, É. (2007) · American Journal of Veterinary Research · doi:10.2460/ajvr.68.3.297 · Cited by 16
金山, 寿., Matsunari, I., & Kajinami, K. (2007) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2007.05.011 · Cited by 16
Estimation and comparison of derived preference scores from the SF-36 in lung transplant patients
Lobo, F. S., Gross, C. R., & Matthees, B. J. (2004) · Quality of Life Research · doi:10.1023/b:qure.0000018488.95206.d6 · Cited by 16
Comparison of new generation motion‐resistant pulse oximeters
Townshend, J., Taylor, B. J., Galland, B. C., & Williams, S. (2006) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.2006.00873.x · Cited by 16
Agreement in Functional Assessment
Haley, S. M., Ni, P., Coster, W. J., Black‐Schaffer, R. M., Siebens, H. C., & Tao, W. (2006) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000228524.31576.15 · Cited by 16
Schauvliege, S., den Eede, A. V., Duchateau, L., Pille, F. J., Vlaminck, L. E. M., & Gasthuys, F. (2009) · Veterinary Anaesthesia and Analgesia · doi:10.1111/j.1467-2995.2009.00446.x · Cited by 16
Brown, M. A., McHugh, L., Mangos, G., & Davis, G. K. (2003) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1046/j.1471-0528.2003.00008.x · Cited by 23
Diffusion-Weighted MR Imaging Findings of Cortical Vein Thrombosis at 3 T
Yildiz, M. E., Özcan, Ü. A., Turk, A. S., Ulus, Ö. S., Erzen, C., & Di̇nçer, A. (2014) · Clinical Neuroradiology · doi:10.1007/s00062-014-0301-y · Cited by 16
da Silva, D. F., Simões, H. G., & Machado, F. A. (2014) · Science & Sports · doi:10.1016/j.scispo.2014.10.006 · Cited by 23
The need for specialist review of pathology in paediatric cancer
Parkes, S. E., Muir, K. R., Cameron, A., Raafat, F., Stevens, M., Morland, B., Barber, P. C., Carey, M., Fox, H., Jones, E., et al. (1997) · British Journal of Cancer · doi:10.1038/bjc.1997.199 · Cited by 16
Evaluation of tissue saturation as a noninvasive measure of mixed venous saturation in children
Levy, R. J., Stern, W., Minger, K. I., Montenegro, L. M., Ravishankar, C., Rome, J. J., Nicolson, S. C., & Jobes, D. R. (2005) · Pediatric Critical Care Medicine · doi:10.1097/01.pcc.0000185488.44719.b0 · Cited by 16
Improved brief assessment of cognition in aging and dementia
Lindeboom, R., Schmand, B. A., Holman, R., de Haan, R. J., & Vermeulen, M. (2004) · Neurology · doi:10.1212/01.wnl.0000133404.21840.b9 · Cited by 22
Quantitative and qualitative analysis of haemoglobin variants using capillary zone electrophoresis
Gerritsma, J., Sinnige, D., Drieze, C., Sittrop, B., Houtsma, P., Ulshorst-Jansen, N. H., & Huisman, W. H. (2000) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563001899320 · Cited by 16
Piepoli, M. F., VILLANI, G. Q., Aschieri, D., Bennati, S., Groppi, F., Pisati, M. S., Rosi, A., & Capucci, A. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2005.07.041 · Cited by 16
A new general regression-based approach for method comparison studies
Sotgia, S., Zinellu, A., Pinna, G. A., Deiana, L., & Carru, C. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.194 · Cited by 16
Reliability of the Cambridge Low Contrast Gratings
Jones, H. S., Moseley, M. J., & Thompson, J. R. (1994) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1994.tb00009.x · Cited by 16
Mets, B., Frumento, R. J., Bennett-Guerrero, E., & Naka, Y. (2002) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2002.128411 · Cited by 16
Rahman, M. Y. A. E., Hui, W., Dsebissowa, F., Schubert, S., Hübler, M., Hetzer, R., Lange, P., & Abdul‐Khaliq, H. (2004) · Pediatric Cardiology · doi:10.1007/s00246-004-0757-7 · Cited by 16
Practicality and accuracy of prehospital rapid venous blood glucose determination
Holstein, A., Kühne, D., Elsing, H.-G., Thiessen, E. S., Plaschke, A., Widjaja, A., Vogel, M.-Y., & Egberts, E. ‐. (2000) · The American Journal of Emergency Medicine · doi:10.1053/ajem.2000.7324 · Cited by 18
Test–retest reliability of pulse wave velocity in individuals with chronic spinal cord injury
Miyatani, M., Masani, K., Moore, C., Szeto, M., OH, P. I., & Craven, B. C. (2012) · Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000042 · Cited by 16
A reappraisal of the measurement of glomerular filtration rate in pre-term infants
Wilkins, B. H. (1992) · Pediatric Nephrology · doi:10.1007/bf00869724 · Cited by 16
A clinical evaluation of the Topcon RM6000 autorefractor
Elliott, D. B., & Wilkes, R. D. (1989) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.1989.tb03076.x · Cited by 16
A Right Ventricular Pressure Waveform Based Pulse Contour Cardiac Output Algorithm in Canines
Karamanoglu, M., & Bennett, T. (2006) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-006-9014-4 · Cited by 16
Urinary Urea Nitrogen is Imprecise as a Predictor of Protein Balance in Burned Children
Prelack, K., Dwyer, J. T., Yu, Y., Sheridan, R. L., & Tompkins, R. G. (1997) · Journal of the American Dietetic Association · doi:10.1016/s0002-8223(97)00127-2 · Cited by 16
Musch, D. C., Gillespie, B. W., Vautaw, B. M., Niziol, L. M., Mills, R. P., & Lichter, P. R. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0006 · Cited by 16
Ward, L. C., & Heitmann, B. L. (2001) · Clinical Nutrition · doi:10.1054/clnu.2000.0362 · Cited by 18
Magkos, F., Μanios, Y., Babaroutsi, E., & Sidossis, L. S. (2006) · Journal of Human Nutrition and Dietetics · doi:10.1111/j.1365-277x.2006.00718.x · Cited by 16
Rapid DNA fingerprinting of pathogens by flow cytometry
Larson, E. J., Hakovirta, J. R., Cai, H., Jett, J. H., Burde, S., Keller, R. A., & Marrone, B. L. (2000) · Cytometry · doi:10.1002/1097-0320(20001101)41:3<166::aid-cyto2>3.0.co;2-y · Cited by 26
C-reactive protein measured in dried blood spots from patients with cystic fibrosis
Cordon, S. M., Elborn, J. S., Hiller, E., & Shale, D. J. (1991) · Journal of Immunological Methods · doi:10.1016/0022-1759(91)90273-i · Cited by 16
Kawahira, Y., Kishimoto, H., Kawata, H., Ikawa, S., Ueda, H., Nakajima, T., Kayatani, F., Inamura, N., & Nakada, T. (1997) · Journal of Cardiac Surgery · doi:10.1111/j.1540-8191.1997.tb00136.x · Cited by 16
Low-energy reporting and duration of recording period
Whybrow, S., Horgan, G. W., & Stubbs, R. J. (2007) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602826 · Cited by 16
Estimation of circulating blood volume in infants using the pulse dye densitometry method
Nagano, K., Kusaka, T., Okubo, K., Yasuda, S., Okada, H., Namba, M., Kawada, K., Imai, T., Isobe, K., & Itoh, S. (2005) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2005.01406.x · Cited by 16
Jartti, L., Hakanen, M., Paakkunainen, U., Raittinen, P., & Rönnemaa, T. (2000) · Acta Paediatrica · doi:10.1080/080352500750043648 · Cited by 16
Pulse oximetry from the nasal septum
Ezri, T., Lurie, S., Konichezky, S., & Soroker, D. (1991) · Journal of Clinical Anesthesia · doi:10.1016/0952-8180(91)90091-z · Cited by 16
Her, C., Mandy, S., & Bairamian, M. (2005) · Anesthesiology · doi:10.1097/00000542-200503000-00016 · Cited by 16
Sahuquillo, P., Tembl, J. I., Parkhutik, V., Vazquez-Costa, J. F., Sastre, I., & Lago, A. P. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.008 · Cited by 16
Dong, W., Sun, Y., Ong, S. H., Chai, P., Teo, L., & Low, A. F.-H. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2237907 · Cited by 19
Reliability of weight-bearing heel pad thickness measurements by ultrasound
Rome, K., Campbell, R., Flint, A., & HASLOCK, I. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00038-2 · Cited by 16
Küpper, J., Bartz, M., Schultink, J. W., Lukito, W., & Deurenberg, P. (1998) · PubMed · Cited by 22
Demoulin, C., Verbunt, J., Winkens, B., Knottnerus, J. A., & Smeets, R. (2009) · Disability and Rehabilitation · doi:10.3109/09638280903071842 · Cited by 16
Wilkinson, C., Carr, A. J., & Doherty, M. (2005) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2004.033282 · Cited by 16
Rostoker, G., Andrivet, P., Pham, I., Griuncelli, M., & Adnot, S. (2009) · BMC Nephrology · doi:10.1186/1471-2369-10-16 · Cited by 16
Identificação do limiar anaeróbio em indivíduos com diabetes tipo-2 sedentários e fisicamente ativos
Moreira, S., Simões, G. B., Hiyane, W. C., Campbell, C., & Simões, H. (2007) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552007000400008 · Cited by 26
An easy to calculate equation to estimate GFR based on inulin clearance
Tsinalis, D., & Thiel, G. T. (2009) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfp193 · Cited by 16
Transcutaneous measurement of bilirubin in Turkish newborns: comparison with total serum bilirubin.
Kaynak-Türkmen, M., Aydoğdu, S. A., Gökbulut, C., Yenisey, Ç., Söz, Ö., & Çetinkaya-Çakmak, B. (2011) · PubMed · Cited by 16
Test-Retest Stability of the Task and Ego Orientation Questionnaire
Lane, A. M., Nevill, A. M., Bowes, N., & Fox, K. R. (2005) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2005.10599304 · Cited by 16
Nii, M., Shimizu, M., Roman, K. S., Konstantinov, I. E., Li, J., Redington, A. N., & JAEGGI, E. T. (2006) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.09.010 · Cited by 18
The Relationship Between Age and Bronchial Responsiveness
Renwick, D. S., & Connolly, M. J. (1999) · CHEST Journal · doi:10.1378/chest.115.3.660 · Cited by 16
Pressure‐volume relationships in acute lung injury: methodological and clinical implications
Nunes, S. L., Uusaro, A. V., & Takala, J. A. (2004) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.0001-5172.2004.0313.x · Cited by 16
Müller, S., Bläuer, K., Kremer, M., Thorn, M., Mehrabi, A., Meinzer, H.-P., Hinz, U., Metzger, J., Büchler, M. W., & Schmied, B. M. (2009) · Journal of Surgical Research · doi:10.1016/j.jss.2009.04.050 · Cited by 16
The von Rosen splint compared with the Frejka pillow
Hinderaker, T., Rygh, M., & Udén, A. (1992) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679209154751 · Cited by 16
Rymer, J. C., Sabatier, R., Daver, A., Bourleaud, J., Assicot, M., Bremond, J., Rapin, J., Salhi, S. L., Thirion, B., Vassault, A. J., et al. (1999) · PubMed · Cited by 16
Dahlberg, M., & Whitelaw, A. (1997) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519709105234 · Cited by 16
de Boode, W. P., Hopman, J. C. W., Daniëls, O., van der Hoeven, H. G., & Liem, K. D. (2007) · Pediatric Research · doi:10.1203/pdr.0b013e318030d0c6 · Cited by 18
Brukx, L. J. C. E., & Waelkens, J. J. J. (2003) · Annals of Human Biology · doi:10.1080/0301446031000075989-1 · Cited by 16
Kurotobi, S., Sano, T., Matsushita, T., Takeuchi, M., Kogaki, S., Miwatani, T., & Okada, S. (1997) · Heart · doi:10.1136/hrt.78.3.305 · Cited by 16
High accuracy of the nine equivalents of nursing manpower use score assessed by critical care nurses
Perren, A., Previsdomini, M., Perren, I., & Merlani, P. G. (2012) · Swiss Medical Weekly · doi:10.4414/smw.2012.13555 · Cited by 16
Pugnale, P., Latorre, P., Rossi, C., Crovatto, K., Pazienza, V., Gottardi, A. D., & Negro, F. (2005) · Journal of Virological Methods · doi:10.1016/j.jviromet.2005.11.007 · Cited by 16
Stability of questionnaire items in sport and exercise psychology: Bootstrap limits of agreement
WILSON, K., & Batterham, A. M. (1999) · Journal of Sports Sciences · doi:10.1080/026404199365588 · Cited by 16
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.