STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 24,501–24,600 of 47,868
Reproducibility of trabecular structure analysis using flat-panel volume computed tomography
Cheung, A. C., Bredella, M. A., Khalaf, M. A., Grasruck, M., Leidecker, C., & Gupta, R. (2009) · Skeletal Radiology · doi:10.1007/s00256-009-0707-9 · Cited by 16
Menke, J. (2013) · Medical Decision Making · doi:10.1177/0272989x13475719 · Cited by 17
Use of simple clinical parameters to assess severity of bronchiolitis
Mai, T., Selby, A. K., Simpson, J., & Isaacs, D. (1995) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.1995.tb00859.x · Cited by 16
Veqar, Z., Hussain, M., & Moiz, J. A. (2014) · North American Journal of Medical Sciences · doi:10.4103/1947-2714.131238 · Cited by 17
Can Low-Dose Unenhanced Chest CT Be Used for Follow-Up of Lung Nodules?
de Jong, P. A., Leiner, T., Lammers, J. J., & Gietema, H. A. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.7577 · Cited by 16
Modeling upper eyelid kinematics during spontaneous and reflex blinks
Malbouisson, J. M. C., Messias, A. M. V., Garcia, D. M., Cechetti, S. D. P., Barbosa, J. C., & Cruz, A. A. V. E. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.06.006 · Cited by 18
Robson, A. G., & Parry, N. R. A. (2008) · Visual Neuroscience · doi:10.1017/s0952523808080681 · Cited by 16
Conducting shorter VEP tests to estimate visual acuity via assessment of SNR
Iyer, K. K., Bradley, A. P., & Wilson, S. J. (2012) · Documenta Ophthalmologica · doi:10.1007/s10633-012-9355-9 · Cited by 16
Anderson, R. E., Sartipy, U., & Jakobsson, J. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem061 · Cited by 16
Sacchetto, D., Morra, L., Agliozzo, S., Bernardi, D., Björklund, T., Brancato, B., Bravetti, P., Carbonaro, L. A., Correale, L., Fantò, C., et al. (2015) · European Radiology · doi:10.1007/s00330-015-3784-2 · Cited by 16
Arigoni, M., Kneifel, S., Fandino, J., Khan, N., Burger, C., & Buck, A. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000319 · Cited by 16
Precision of Tympanometric Measurements
Gaihede, M. L., & Ovesen, T. (1997) · Journal of Speech Language and Hearing Research · doi:10.1044/jslhr.4001.215 · Cited by 16
Characterization of the work–time relationship during cross-country ski ergometry
Fukuda, D. H., Hetrick, R. P., Kendall, K. L., Smith‐Ryan, A. E., Jackson, M. E., & Stout, J. R. (2013) · Physiological Measurement · doi:10.1088/0967-3334/35/1/31 · Cited by 16
Lesne-Hulin, A., Blanchet, B., Audard, V., Barau, C., Furlan, V., Dürrbach, A., Taïeb, F., Lang, P., Grimbert, P., & Tod, M. M. (2009) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31819c077c · Cited by 16
Mejía‐Rodríguez, F., Neufeld, L. M., García‐Guerra, A., Quezada-Sanchez, A. D., & Orjuela, M. A. (2014) · Maternal and Child Health Journal · doi:10.1007/s10995-013-1263-4 · Cited by 17
Influence of Blood Collection Systems on Coagulation Tests
Yavaş, S., Ayaz, S., Köse, S. K., Ulus, F., & Ulus, T. A. (2012) · Turkish Journal of Hematology · doi:10.5505/tjh.2012.59254 · Cited by 16
Kang, S.-J., Lim, H., Choi, B., Choi, S., Yoon, M., Hwang, G., Shin, J., & Tahk, S. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.01.009 · Cited by 16
Automatic entropy-based femur segmentation and fast length measurement for fetal ultrasound images
Wang, C. (2014) · International Conference on Advanced Robotics and Intelligent Systems (ARIS) · doi:10.1109/aris.2014.6871490 · Cited by 20
Egleston, B. L., Chandler, D. W., & Dorgan, J. F. (2010) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2010.009112 · Cited by 16
You, X., Huang, P., Zhang, C., Wang, M., Zhang, Y., Hong, Y., Wei, S., Liu, C., Pu, Z., Zhang, J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0092445 · Cited by 16
Muzzarelli, S., Ordovas, K. G., Hope, M. D., Meadows, J. J., Higgins, C. B., & Meadows, A. K. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22566 · Cited by 16
The Impact of 10% α-Hydroxy Acid Emulsion on Skin pH
Schreml, S., Meier, R. J., Albert, M. G., Seidl, U., Zeller, V., Behm, B., Landthaler, M., Abels, C., & Babilas, P. (2011) · Skin Pharmacology and Physiology · doi:10.1159/000331204 · Cited by 17
Measurement of hemoglobin saturation by oxygen in children and adolescents with sickle cell disease
Needleman, J. P., Setty, Y. B. N., Varlotta, L., Dampier, C., & Allen, J. L. (1999) · Pediatric Pulmonology · doi:10.1002/(sici)1099-0496(199912)28:6<423::aid-ppul7>3.0.co;2-c · Cited by 61
Li, Q., & Zhang, J. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2255 · Cited by 16
Regan, H. K., Detwiler, T. J., Huang, J., Lynch, J. J., & Regan, C. P. (2007) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2007.05.005 · Cited by 17
Inhaled Nitric Oxide Delivery by Anesthesia Machines
Ceccarelli, P., Bigatello, L. M., HESS, D. R., Kwo, J., & Melendez, L. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200002000-00045 · Cited by 16
Kerlik, J., Penesová, A., Vlček, M., Imrich, R., Vogeser, M., & Rádiková, Ž. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2010.03.005 · Cited by 19
Retinal arteriolar and venular phenotypes in a Flemish population: Reproducibility and correlates
Liu, Y.-P., Richart, T., Jin, Y., Struijker-Boudier, H. A. J., & Staessen, J. A. (2011) · Artery Research · doi:10.1016/j.artres.2011.03.004 · Cited by 16
Sources of variation in assessing left atrial functions by 2D speckle-tracking echocardiography
Rimbaş, R. C., Mihaila, S. B., & Vinereanu, D. (2014) · Heart and Vessels · doi:10.1007/s00380-014-0602-8 · Cited by 16
DiMaggio, M. A., Ohs, C. L., & Petty, B. D. (2010) · North American Journal of Aquaculture · doi:10.1577/a09-067.1 · Cited by 16
Left ventricular synchronicity is impaired in patients with active acromegaly
Kırış, A., Erem, C., Turan, O. E., Civan, N., Kırış, G., Nuhoğlu, İ., İlter, A., Ersöz, H. Ö., & Kutlu, M. (2012) · Endocrine · doi:10.1007/s12020-012-9859-9 · Cited by 16
A proposed method for the evaluation of body fat in Japanese adults that predicts obesity
Minematsu, K., Takamura, N., Goto, K., Honda, S., Aoyagi, K., Moji, K., & Tsunawake, N. (2011) · Nutrition Research · doi:10.1016/j.nutres.2011.01.008 · Cited by 16
The Footprint method to assess transmalleolar axis
Hazlewood, M. E., Simmons, A. N., Johnson, W. T., Richardson, A., van der Linden, M. L., Hillman, S. J., & Robb, J. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2006.06.011 · Cited by 16
Concordancia en el diagnóstico entre atención primaria y salud mental
González, N. L., Goñi-Sarriés, A., de Jalón, E. G., & Urra, E. L. (2008) · Atención Primaria · doi:10.1157/13123680 · Cited by 16
Doesch, C., Huck, S., Böhm, C. K., Michaely, H. J., Fluechter, S., Haghi, D., Dinter, D. J., Borggrefe, M., & Papavassiliu, T. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.03.034 · Cited by 16
Yamashita, S., Yokoyama, K., Onoguchi, M., Yamamoto, H., Hiko, S., Horita, A., & Nakajima, K. (2013) · Annals of Nuclear Medicine · doi:10.1007/s12149-013-0774-9 · Cited by 16
Interobserver Agreement in Duplex Scanning for Vein Grafts
Ihlberg, A., Albäc, A., Roth, W. D., Edgren, J., & Lepäntalo, M. (2000) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.1999.1068 · Cited by 16
Frasca, D., Mounios, H., Giraud, B., Boisson, M., Debaene, B., & Mimoz, O. (2015) · Anaesthesia · doi:10.1111/anae.13028 · Cited by 16
Karl, K., Kagan, K. O., & Chaoui, R. (2011) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.10137 · Cited by 19
C-peptide in dried blood spots
Johansson, J., Becker, C., Persson, N.-G., Fex, M., & Törn, C. (2010) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2010.501113 · Cited by 17
Szczapa, T., Karpiński, Ł., Moczko, J., Weindling, M., Kornacka, A., Wróblewska, K., Adamczak, A. M., Jopek, A., Chojnacka, K., & Gadzinowski, J. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.8.087006 · Cited by 16
Intra- and interrater agreement of pressure pain thresholds in children with orthopedic disorders
Nikolajsen, L., Kristensen, A. D., Pedersen, L. K., Rahbek, O., Jensen, T. S., & Møller‐Madsen, B. (2011) · Journal of Children s Orthopaedics · doi:10.1007/s11832-011-0336-4 · Cited by 19
Coxon, T. L., Brook, A. H., Barron, M. J., & Smith, R. N. (2012) · Cells Tissues Organs · doi:10.1159/000336440 · Cited by 21
A Hybrid Approach to Segmentation of Diseased Lung Lobes
Wei, Q., & Hu, Y. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2332955 · Cited by 16
Hodges, G. J., Mattar, L., Zuj, K. A., Greaves, D. K., Arbeille, P., Hughson, R. L., & Shoemaker, J. K. (2010) · Experimental Physiology · doi:10.1113/expphysiol.2010.054254 · Cited by 17
MacGillivray, T., & Patton, N. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260821 · Cited by 16
Majid, A., Heaney, D. C., Padmanabhan, N. V. D. M. N., & Spooner, R. (1996) · Journal of Clinical Pathology · doi:10.1136/jcp.49.12.1019 · Cited by 16
Sand, T., Nilsen, K. B., Hagen, K., & Stovner, L. J. (2010) · Cephalalgia · doi:10.1177/0333102409356023 · Cited by 16
Saravelos, S. H., & Li, T. C. (2015) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2015.06.024 · Cited by 18
Cinthio, M., Hasegawa, H., & Kanai, H. (2011) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1879 · Cited by 16
Reliability of acuities determined with the sweep visual evoked potential (sVEP)
Ridder, W. H., Tong, A., & Floresca, T. (2012) · Documenta Ophthalmologica · doi:10.1007/s10633-012-9312-7 · Cited by 16
Kim, J., Kim, B., Lee, K.-H., Kim, K. W., Kim, J. H., Lee, S. I., Kim, K. T., Choe, W. J., Park, J.-S., & Kim, J. (2013) · Journal of International Medical Research · doi:10.1177/0300060513487649 · Cited by 16
PAGE, R. B., Scrivani, P. V., Dykes, N. L., Erb, H. N., & Hobbs, J. M. (2006) · Veterinary Radiology & Ultrasound · doi:10.1111/j.1740-8261.2006.00129.x · Cited by 16
Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study
Rijken, M. J., Moroski, W. E., Kiricharoen, S., Karunkonkowit, N., Stevenson, G., Ohuma, E. O., Noble, J. A., Kennedy, S. H., McGready, R., Papageorghiou, A. T., et al. (2012) · Malaria Journal · doi:10.1186/1475-2875-11-5 · Cited by 16
Domingo, C., Canturri, E., Luján, M., Moreno, A., Espuelas, H., & Marín, A. (2006) · Archivos de Bronconeumología · doi:10.1157/13088030 · Cited by 16
Spirometry may underestimate airway obstruction in professional G reek athletes
Myrianthefs, P. M., Grammatopoulou, I., Katsoulas, T. A., & Baltopoulos, G. J. (2013) · The Clinical Respiratory Journal · doi:10.1111/crj.12066 · Cited by 25
Assor, E. (2014) · Journal of Nutrition & Food Sciences · doi:10.4172/2155-9600.1000296 · Cited by 16
Hernández, M. C. V., Jeong, T. H., Murray, C. L., Bastin, M. E., Chappell, F. M., Deary, I. J., & Wardlaw, J. M. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22361 · Cited by 16
A Regression Equation for the Estimation of Maximum Oxygen Uptake in Nepalese Adult Females
Chatterjee, P., Banerjee, A. K., Das, P., & Debnath, P. (2010) · Asian Journal of Sports Medicine · doi:10.5812/asjsm.34873 · Cited by 16
Alkurt, M. T., Peker, İ., & Şanal, Ö. (2007) · International Dental Journal · doi:10.1111/j.1875-595x.2007.tb00146.x · Cited by 16
Saugel, B., Holzapfel, K., Stollfuß, J., Schuster, T., Phillip, V., Schultheiß, C., Schmid, R. M., & Huber, W. (2011) · Scandinavian Journal of Trauma Resuscitation and Emergency Medicine · doi:10.1186/1757-7241-19-31 · Cited by 17
Lee, S. W., Kim, H. J., Kwon, H. K., Son, S. M., Song, J. H., & Kim, M. (2008) · Yonsei Medical Journal · doi:10.3349/ymj.2008.49.2.255 · Cited by 18
Thompson, J. L., Sundt, T. M., Enriquez-Sarano, M. L., Santrach, P. J., & Schaff, H. V. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.01.051 · Cited by 22
Feasibility of radiation dose reduction using AIDR-3D in dynamic pulmonary CT perfusion
Mirsadraee, S., Weir, N. W., Connolly, S., Murchison, J. T., Reid, J. H., Hirani, N., Connell, M., & van Beek, E. J. R. (2015) · Clinical Radiology · doi:10.1016/j.crad.2015.04.004 · Cited by 16
Boshari, T., Urquia, M. L., Sgro, M. D., Souza, L. R. D., & Ray, J. G. (2013) · Paediatric and Perinatal Epidemiology · doi:10.1111/ppe.12038 · Cited by 20
Whitehead, S. J., Ford, C., & Gama, R. M. (2014) · Journal of Clinical Pathology · doi:10.1136/jclinpath-2013-202123 · Cited by 16
Clinical Assessment of Fluid Balance is Incomplete for Colorectal Surgical Patients
Tolstrup, J. S., & Brandstrup, B. (2014) · Scandinavian Journal of Surgery · doi:10.1177/1457496914543978 · Cited by 16
Sladkevicius, P., & Valentin, L. (2015) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-14-0906 · Cited by 19
Hirani, V., Tabassum, F., Aresu, M., & Mindell, J. S. (2010) · Journal of Nutrition · doi:10.3945/jn.109.118430 · Cited by 19
Lubberink, M., Wong, Y. Y., Raijmakers, P. G. H. M., Schuit, R. C., Luurtsema, G., Boellaard, R., Knaapen, P., Noordegraaf, A. V., & Lammertsma, A. A. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.080408 · Cited by 16
Development of a low‐cost flow meter to grade the maximum flow rate
Pel, J. J. M., & van MASTRIGT, R. (2001) · Neurourology and Urodynamics · doi:10.1002/nau.2112 · Cited by 16
Assessing the level of agreement between the self‐ and interview‐administered Child‐OIDP
Rosel, E., Tsakos, G., Bernabé, E., Sheiham, A., & Bravo, M. (2010) · Community Dentistry And Oral Epidemiology · doi:10.1111/j.1600-0528.2010.00533.x · Cited by 19
Burns, P., Driessen, B., Boston, R., & Gunther, R. A. (2006) · Veterinary Anaesthesia and Analgesia · doi:10.1111/j.1467-2995.2005.00271.x · Cited by 16
Graham, M. E., Chikka, A., & Jones, P. C. (2011) · Journal of the American Podiatric Medical Association · doi:10.7547/1010475 · Cited by 16
Dendukuri, N., & Reinhold, C. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.185.1.01850003 · Cited by 16
Beckett, J. M., Hartley, T. F., & Ball, M. J. (2009) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2009.008253 · Cited by 16
Mbopi‐Kéou, F., Sagnia, B., Ngogang, J. Y., Angwafo, F., Colizzi, V., Montagnier, L., & Bélec, L. (2012) · Journal of Translational Medicine · doi:10.1186/1479-5876-10-22 · Cited by 18
Image Quality Influences the Assessment of Left Ventricular Function
Großgasteiger, M., Hien, M. D., Graser, B., Rauch, H., Motsch, J., Gondan, M., & Rosendal, C. (2014) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.33.2.297 · Cited by 16
Measurement of tidal volume by using transthoracic impedance variations in rats
Davidson, K. G., Bersten, A. D., Nicholas, T. E., Ravenscroft, P. R., & DOYLE, I. R. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.759 · Cited by 16
Fernández, A. L., López, M. P. A., Ratto, M. E., Saligari, L., Serrate, A. S., de la Rosa, M., Raúl, N., Boada, N., Gallardo, P. F., Ko, I. J., et al. (2015) · Archivos Argentinos de Pediatria · doi:10.5546/aap.2015.221 · Cited by 16
Malek, I. A., Rogers, J., King, A., Clutton, J., Winson, D. M. G., & John, A. (2015) · Arthritis · doi:10.1155/2015/216785 · Cited by 16
The Use of Sound Level Meter Apps in the Clinical Setting
Fava, G., Oliveira, G., Baglione, M. L., Pimpinella, M., & Spitzer, J. B. (2016) · American Journal of Speech-Language Pathology · doi:10.1044/2015_ajslp-13-0137 · Cited by 21
Thépaut, M., Brochard, S., Leboucher, J., Lempereur, M., Stindel, É., Tissot, V., & Borotikar, B. S. (2015) · Skeletal Radiology · doi:10.1007/s00256-015-2298-y · Cited by 16
Marinho, C. D. L., Maioli, M. C. P., Soares, A. R., Bedirian, R., de Melo, P. L., Guimarães, F. S., Ferreira, A. D. S., & Lopes, A. J. (2016) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2016.02.005 · Cited by 17
Piros, G. Á., Domsik, P., Kalapos, A., Lengyel, C., Orosz, A., Forster, T., & Nemes, A. (2016) · Revista Portuguesa de Cardiologia · doi:10.1016/j.repc.2015.09.017 · Cited by 16
How Big Is It Really? Assessing the Efficacy of Indirect Estimates of Body Size in Asian Elephants
Chapman, S. N., Mumby, H. S., Crawley, J. A. H., Mar, K. U., Htut, W., Soe, A. T., Aung, H. H., & Lummaa, V. (2016) · PLoS ONE · doi:10.1371/journal.pone.0150533 · Cited by 18
Atherosclerotic Carotid Plaque Composition: A 3T and 7T MRI‐Histology Correlation Study
Gonzalez, M. R. L., Foo, S. Y., Holmes, W. M., Stewart, W. B., Jr., Muir, K. W., Condon, B. R., Welch, G., & Forbes, K. P. N. (2016) · Journal of Neuroimaging · doi:10.1111/jon.12332 · Cited by 16
Lee, D. H., Lee, J. M., Klotz, E., & Han, J. K. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000247 · Cited by 16
Nielsen, P. S., Riber‐Hansen, R., Schmidt, H., & Steiniche, T. (2016) · Diagnostic Pathology · doi:10.1186/s13000-016-0484-4 · Cited by 16
Mahgerefteh, J., Linder, J. R., Silver, E. J., Hazin, P., Ceresnak, S. R., Hsu, D. T., & Lopez, L. (2016) · Pediatric Cardiology · doi:10.1007/s00246-016-1380-0 · Cited by 19
Mause, S. F., Deck, A., Hennies, M., TECOmedical AG, S., Kaesler, N., Evenepoel, P., Boisvert, W. A., Janssen, U., & Brandenburg, V. M. (2016) · Discoveries · doi:10.15190/d.2016.2 · Cited by 16
Cai, W.-E., Ye, C., Sun, X., Qin, K., Qin, Y., Zhao, D., Wu, F., Hu, Y., Li, H., & Tan, L. (2014) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000165 · Cited by 16
Mori, K., Kimura, S., Matsui, M., Suehisa, E., Hidaka, Y., & Fukushima, N. (2014) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000057 · Cited by 16
Bhatnagar, T., Liu, J., Yung, A. C., Cripton, P. A., Kozłowski, P., Tetzlaff, W., & Oxland, T. R. (2016) · Journal of Neurotrauma · doi:10.1089/neu.2015.4200 · Cited by 19
Feasibility, Reliability and Predictive Value Of In-Ambulance Heart Rate Variability Registration
Yperzeele, L., Hooff, R. V., Smedt, A. D., Nagels, G., Hubloue, I., Keyser, J. D., & Brouns, R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0154834 · Cited by 16
Kotecha, A., Elkarmouty, A., Ajtony, C., & Barton, K. (2015) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2015-307219 · Cited by 16
Ng, W. L., Short, T. G., Gunn, K., Fuge, G. S., & Slon, B. (2014) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1404200411 · Cited by 16
Al-Ekrish, A. A., Al‐Shawaf, R., Schullian, P., Al‐Sadhan, R., Hörmann, R., & Widmann, G. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-016-1419-y · Cited by 16
Determination of Bifidobacterium and Lactobacillus in breast milk of healthy women by digital PCR
Qian, L., Song, H., & Cai, W. (2016) · Beneficial Microbes · doi:10.3920/bm2015.0195 · Cited by 19
Makadzange, T., Bogezi, C., Boyd, K., Gumbo, A. D., Mukura, D., Matubu, A., & Ndhlovu, C. E. (2016) · PLoS ONE · doi:10.1371/journal.pone.0157546 · Cited by 16
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.