STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 25,701–25,800 of 47,868
Koong, D. P., Lee, J., Cheng, T. L., & Little, D. G. (2020) · Journal of Children s Orthopaedics · doi:10.1302/1863-2548.14.200123 · Cited by 14
A validated FFQ to determine dietary intake of vitamin D
Watkins, S., Freeborn, E. J., & Mushtaq, S. (2020) · Public Health Nutrition · doi:10.1017/s136898002000453x · Cited by 15
Kumar, A., Singh, R. K., Apte, V. V., & Kolekar, A. (2021) · Indian Journal of Physiology and Pharmacology · doi:10.25259/ijpp_36_2021 · Cited by 14
Lower Extremity Kinematics of the Y-Balance Test in Healthy and ACL Injured Adolescent Females
Bulow, A., Bellemare, A., Anderson, J. E., Leiter, J., MacDonald, P. B., & Peeler, J. D. (2021) · International Journal of Sports Physical Therapy · doi:10.26603/001c.21529 · Cited by 20
Ibán, M. Á. R., Güemes, S. A., Díaz, R. R., Gismero, C. V. A., Lorente, A., & Heredia, J. D. (2021) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-021-00352-z · Cited by 14
The Cone of Direct Gaze: A Stable Trait
Lobmaier, J. S., Savic, B., Baumgärtner, T., & Knoch, D. (2021) · Frontiers in Psychology · doi:10.3389/fpsyg.2021.682395 · Cited by 15
A systematic method for identifying references to academic research in grey literature
Bickley, M. S., Kousha, K., & Thelwall, M. A. (2022) · Scientometrics · doi:10.1007/s11192-022-04408-4 · Cited by 17
Hoshino, Y., Arai, J., Hirono, K., Maruo, K., Kajikawa, D., Yukitake, Y., Hinata, A., & Miura‐Fuchino, R. (2021) · Journal of Perinatology · doi:10.1038/s41372-021-01189-1 · Cited by 14
Baker, J., Shillabeer, B. C., Brandner, C. R., Graham‐Smith, P., Mills, P., & Read, P. J. (2021) · Pediatric Exercise Science · doi:10.1123/pes.2020-0270 · Cited by 18
Dynamic MR imaging of cerebral perfusion during bicycling exercise
Mast, I. H., Baas, K. P. A., Jorstad, H. T., Wood, J. C., Nederveen, A. J., & Bakermans, A. J. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.118961 · Cited by 17
Sabatino, J., Leo, I., Strangio, A., Bella, S. L., Borrelli, N., Avesani, M., Josen, M., Paredes, J., Piccinelli, E., Sirico, D., et al. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.792622 · Cited by 15
Validity of Neural Networks to Determine Body Position on the Bicycle
Bini, R. R., Serrancolí, G., Santiago, P. R. P., Pinto, A. D. S., & Moura, F. A. (2022) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2022.2070103 · Cited by 14
Schütz, U. H. W., Martensen, T., Kleiner, S., Dreyhaupt, J., Wegener, M., Wilke, H., & Beer, M. (2022) · Diagnostics · doi:10.3390/diagnostics12061391 · Cited by 14
Roque, R., Cordeiro, M. R., Armas, M., Caramelo, F. J., Caseiro‐Alves, F., & Figueiredo-Dias, M. (2022) · npj Breast Cancer · doi:10.1038/s41523-022-00441-x · Cited by 16
Ironside, N. T., Patrie, J. T., Ng, S., Ding, D., Rizvi, T., Kumar, J. S., Mastorakos, P., Hussein, M. Z., Naamani, K. E., Abbas, R., et al. (2022) · Clinical Trials · doi:10.1177/17407745221105886 · Cited by 15
Labott, B. K., Held, S., Wiedenmann, T., Rappelt, L., Wicker, P. V., & Donath, L. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.838358 · Cited by 14
Evaluation of the SpotChecks contrast sensitivity test in children
Anderson, H. A., Mathew, A. R., & Cheng, H. (2022) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13054 · Cited by 14
Zuo, Z., Wang, P., Zeng, W., Qi, W., & Zhang, W. (2022) · Acta Radiologica · doi:10.1177/02841851221135406 · Cited by 18
Lombardo, G., Signoriello, A., Marincola, M., Liboni, P., Faccioni, P., Zangani, A., D’Agostino, A., & Nocini, P. F. (2022) · Materials · doi:10.3390/ma15227995 · Cited by 14
Stubbe, L., Houel, N., & Cottin, F. (2022) · Scientific Reports · doi:10.1038/s41598-022-23915-1 · Cited by 16
Current Status of Measurement Accuracy for Total Hemoglobin Concentration in the Clinical Context
Stawschenko, E., Schaller, T., Kern, B., Bode, B., Dörries, F., Kusche‐Vihrog, K., Gehring, H., & Wegerich, P. (2022) · Biosensors · doi:10.3390/bios12121147 · Cited by 18
Assessment of Axial Postural Abnormalities in Parkinsonism: Automatic Picture Analysis Software
Artusi, C. A., Geroin, C., Imbalzano, G., Camozzi, S., Aldegheri, S., Lopiano, L., Tinazzi, M., & Bombieri, N. (2023) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.13692 · Cited by 18
Zieff, G. H., Stone, K. J., Paterson, C. A., Fryer, S. M., Diana, J. C., Blackwell, J. A., Meyer, M. L., & Stoner, L. R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1108219 · Cited by 17
Qin, Y., Deng, H., Lu, M., Cheng, Y., Mi, B., Xiao, Y., & Zhou, J. (2023) · Nutrients · doi:10.3390/nu15040856 · Cited by 21
Stett, A., Schatz, A., Gekeler, F., & Franklin, J. G. (2023) · Translational Vision Science & Technology · doi:10.1167/tvst.12.2.29 · Cited by 17
Ponnusamy, R., Zhang, M., Chang, Z., Wang, Y., Guida, C., Kuang, S., Sun, X., Blackadar, J., Driban, J. B., McAlindon, T. E., et al. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104713 · Cited by 17
Improving wastewater-based epidemiology performance through streamlined automation
Banadaki, M. D., Torabi, S., Strike, W., Noble, A., Keck, J. W., & Berry, S. M. (2023) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2023.109595 · Cited by 14
Wang, Z., Destro, A., Petersson, S., Cenni, F., & Wang, R. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111567 · Cited by 15
Quispe, M. D., Quispe, C., Serrano, L., Trigo, J. D., Irañeta, J. J. B., & Quispe, E. C. (2023) · animal · doi:10.1016/j.animal.2023.100800 · Cited by 16
Quantification of the Phenomena Affecting Reflective Arterial Photoplethysmography
Rovas, G., Bikia, V., & Stergiopulos, N. (2023) · Bioengineering · doi:10.3390/bioengineering10040460 · Cited by 18
Kraszni, M., Ágh, F., Horváth, D., Mirzahosseini, A., & Horváth, P. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24087544 · Cited by 14
Jiang, R., Zhang, D., Zhao, Z., & Mei, S. (2023) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2023.115437 · Cited by 14
Saiki, Y., Kabata, T., Ojima, T., Kajino, Y., Kubo, N., & Tsuchiya, H. (2023) · Bone and Joint Research · doi:10.1302/2046-3758.125.bjr-2022-0257.r1 · Cited by 14
Croci, E., Born, P., Eckers, F., Nüesch, C., Baumgartner, D., Müller, A. M., & Mündermann, A. (2023) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2023.03.025 · Cited by 14
González-Rubio, J. M., González-Rubio, J. M., Pedraza‐Díaz, S., Cañas, A., Portilla, A. C., Lucena, M. A., Rábano, A. R., Castaño, A., & Esteban, M. (2023) · Environment International · doi:10.1016/j.envint.2023.107958 · Cited by 14
Rossetto, A., Torres, T., Platton, S., Vulliamy, P., Curry, N. S., & Davenport, R. A. (2023) · Journal of Thrombosis and Haemostasis · doi:10.1016/j.jtha.2023.05.005 · Cited by 14
Dragutinovic, B., Jacobs, M. W., Feuerbacher, J. F., Goldmann, J., Cheng, S., & Schumann, M. (2023) · Biology of Sport · doi:10.5114/biolsport.2024.125596 · Cited by 17
Clinical Validation of Novel Digital Measures: Statistical Methods for Reliability Evaluation
Ratitch, B., Trigg, A., Majumder, M., Vlajnic, V., Rethemeier, N., & Nkulikiyinka, R. (2023) · Digital Biomarkers · doi:10.1159/000531054 · Cited by 17
Jaroenngarmsamer, T., Benali, F., Fladt, J. C., Singh, N., Bala, F., Tymianski, M., Hill, M. D., Goyal, M., Ganesh, A., & On behalf of the ESCAPE-NA1 Investigators (2023) · American Journal of Neuroradiology · doi:10.3174/ajnr.a7981 · Cited by 14
Jenneson, V. L., Greenwood, D. C., Clarke, G., Rains, T., Tempest, B., Shute, B., & Morris, M. A. (2023) · Public Health Nutrition · doi:10.1017/s1368980023001842 · Cited by 18
Γιαννακού, Ε., Fotiadou, S., Gourgoulis, V., Mavrommatis, G., & Aggelousis, N. (2023) · Neurology International · doi:10.3390/neurolint15030070 · Cited by 14
Wearables for running gait analysis: A study protocol
Mason, R., Godfrey, A., Barry, G., & Stuart, S. (2023) · PLoS ONE · doi:10.1371/journal.pone.0291289 · Cited by 16
Santi, N. S., Biswal, S. B., Naik, B. N., Sahoo, J. P., & Rath, B. (2023) · Cureus · doi:10.7759/cureus.45098 · Cited by 14
King‐Dowling, S., Fortnum, K., Chirico, D., Le, T. D., KWAN, M. Y. W., Timmons, B. W., & Cairney, J. (2023) · American Journal of Human Biology · doi:10.1002/ajhb.23987 · Cited by 15
Ruangsuphaphichat, A., Brockmann, L., Sirasaporn, P., Manimmanakorn, N., Hunt, K. J., & Saengsuwan, J. (2023) · Spinal Cord · doi:10.1038/s41393-023-00935-w · Cited by 14
Collister, B. L., Hair, J. W., Hostetler, C. A., Cook, A., Ibrahim, A. I., Boss, E., Scarino, A. J., Shingler, T., Slade, W. H., Twardowski, M. S., et al. (2023) · Remote Sensing of Environment · doi:10.1016/j.rse.2023.113898 · Cited by 16
Burke, J., Engelmann, J., Hamid, C., Reid‐Schachter, M., Pearson, T., Pugh, D., Dhaun, N., Storkey, A., KING, S. E., MacGillivray, T., et al. (2023) · Translational Vision Science & Technology · doi:10.1167/tvst.12.11.27 · Cited by 14
Li, J., Kong, X., Wang, J., Zhu, H., Zhong, J., Cao, Y., & Wu, B. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-068794 · Cited by 14
Development and validation of a food frequency questionnaire in adult Saudi subjects in Jeddah city
Ajabnoor, S. M., Jambi, H., & Bahijri, S. (2024) · BMC Public Health · doi:10.1186/s12889-023-17511-9 · Cited by 15
Rodríguez‐Barbero, S., González‐Mohíno, F., González‐Ravé, J. M., Rodrigo‐Carranza, V., & Santos‐García, D. J. (2024) · Sports Biomechanics · doi:10.1080/14763141.2023.2298960 · Cited by 17
Marynissen, S. J. J., Junius, G., den Steen, E. V., Patteet, L., Duchateau, L., Croubels, S., Daminet, S., & Paepe, D. (2024) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.16981 · Cited by 17
Factors affecting the analysis and interpretation of sperm quality in frozen/thawed stallion semen
Hernández‐Avilés, C., Ramírez‐Agámez, L., Varner, D. D., & Love, C. C. (2024) · Theriogenology · doi:10.1016/j.theriogenology.2024.01.039 · Cited by 14
Wang, J., Wang, R., Zhao, P., Han, T., Cui, X., He, Y., & Li, M. (2024) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2024.104125 · Cited by 15
A mathematical model for the within-host (re)infection dynamics of SARS-CoV-2
Schuh, L., Markov, P. V., Veliov, V. M., & Stilianakis, N. I. (2024) · Mathematical Biosciences · doi:10.1016/j.mbs.2024.109178 · Cited by 20
Moghadam, S. M., Ortega-Auriol, P., Yeung, T., & Choisne, J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1372669 · Cited by 22
Oberhofer, K., Knopfli, C., Achermann, B. B., & Lorenzetti, S. (2024) · Sports · doi:10.3390/sports12040092 · Cited by 14
Is the Bland-Altman plot method useful without inferences for accuracy, precision, and agreement?
Silveira, P. S. P., Vieira, J. E., & Siqueira, J. D. O. (2024) · Revista de Saúde Pública · doi:10.11606/s1518-8787.2024058005430 · Cited by 21
de Haan, M., van der Zwaard, S., Schreven, S., Beek, P. J., & Jaspers, R. T. (2024) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2024.03.015 · Cited by 15
Studying effect of temperature on the efficiency of solar cells through the interpolation method
Khalis, M., Ouissaaden, F. I., Khaldi, S. E., Kamel, H., Elmourabit, F., & Dlimi, S. (2024) · Hybrid Advances · doi:10.1016/j.hybadv.2024.100231 · Cited by 14
van Bokhorst, Q. N. E., Houwen, B. B. S. L., Hazewinkel, Y., Vlugt, M. V., Beaumont, H., Grootjans, J., van Tilburg, A., Fockens, P., Bossuyt, P. M., Dekker, E., et al. (2024) · Endoscopy · doi:10.1055/a-2371-3693 · Cited by 15
Accuracy of 3D real-time MRI temperature mapping in gel phantoms during microwave heating
Dietrich, O., Lentini, S., Öcal, O., Bour, P., Faller, T. L., Ozenne, V., Ricke, J., & Seidensticker, M. (2024) · European Radiology Experimental · doi:10.1186/s41747-024-00479-5 · Cited by 14
Baty, F., Cvetkovic, D., Boesch, M., Bauer, F., Martins, N. R. A., Rossi, R. M., Schoch, O. D., Annaheim, S., & Brutsche, M. H. (2024) · Sensors · doi:10.3390/s24196229 · Cited by 16
Deep learning approaches for assessing pediatric sleep apnea severity through SpO2 signals
Mortazavi, E., Tarvirdizadeh, B., Alipour, K., & Ghamari, M. (2024) · Scientific Reports · doi:10.1038/s41598-024-67729-9 · Cited by 16
Tinsley, G. M., Rodriguez, C., Florez, C. M., Siedler, M. R., Tinoco, E., McCarthy, C., & Heymsfield, S. B. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1485450 · Cited by 16
Böttinger, M. J., Mellone, S., Klenk, J., Jansen, C.-P., Stefanakis, M., Litz, E., Bredenbrock, A., Fischer, J.-P., Bauer, J. M., Becker, C., et al. (2025) · JMIR Aging · doi:10.2196/67322 · Cited by 15
Al‐Haidri, W., Akhatov, A., Usmanova, I., Salimov, F., Al-Habeeb, M., Il'yasov, K. A., & Brui, E. A. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.107770 · Cited by 14
Warneke, K., Siegel, S. D., Drabow, J., Lohmann, L. H., Jochum, D., Freitas, S. R., Afonso, J. R., & Konrad, A. (2025) · The Ultrasound Journal · doi:10.1186/s13089-025-00424-6 · Cited by 15
Nersesyan, A. K., Proietti, S., Knasmüller, S., Bonassi, S., & Fenech, M. F. (2025) · Mutagenesis · doi:10.1093/mutage/geaf006 · Cited by 15
Lammers, K., Kluivers, K. B., Vierhout, M. E., Prokop, M., & Fütterer, J. J. (2013) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.12462 · Cited by 18
Variability of respiration and sleep during polysomnography in individuals with TBI
Lu, W. Y.-R., Cantor, J. B., Aurora, R. N., Nguyen, M., Ashman, T. A., Spielman, L. A., Ambrose, A. F., Krellman, J. W., & Gordon, W. A. (2014) · Neurorehabilitation · doi:10.3233/nre-141117 · Cited by 16
Curcic, J., Sauter, M. M., Schwizer, W., Fried, M., Boesiger, P., & Steingoetter, A. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24530 · Cited by 14
Arnold, R., Schwendinger, D., Jung, S., Pöhl, M., Jung, B. A., Geiger, J., & Gimpel, C. (2015) · Pediatric Nephrology · doi:10.1007/s00467-015-3198-z · Cited by 14
Zhong, S., Zhang, Y., Chen, L., Wang, S., & Li, W. (2015) · Echocardiography · doi:10.1111/echo.12990 · Cited by 14
Does knee joint alignment with the axis of the isokinetic dynamometer affect peak torque?
Houweling, T. A. W., & Hamzeh, M. A. (2010) · Isokinetics and Exercise Science · doi:10.3233/ies-2010-0387 · Cited by 20
Andersson, M., Jägervall, K., Eriksson, P., Persson, A., Granérus, G., Wang, C., & Smedby, Ö. (2015) · BMC Medical Imaging · doi:10.1186/s12880-015-0086-8 · Cited by 14
Relationship between Serum Testosterone and Fracture Risk in Men: A Comparison of RIA and LC-MS/MS
Tran, T. S., Seibel, M. J., Eisman, J. A., Kushnir, M. M., Rockwood, A. L., & Nguyen, T. V. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.242339 · Cited by 15
A comparison between GATE4 results and MCNP4B published data for internal radiation dosimetry
Parach, A. A., & Rajabi, H. (2011) · Nuklearmedizin - NuclearMedicine · doi:10.3413/nukmed-0363-10-10 · Cited by 16
Electroanatomic Relationships in Patients With Primum Atrioventricular Septal Defect
Hakacova, N., Wagner, G. S., & Idriss, S. F. (2009) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2009.08.009 · Cited by 14
López‐Miguel, A., Nieto, J. C., Díez-Cuenca, M., Pinero, D. P., & Maldonado, M. J. (2009) · Eye · doi:10.1038/eye.2009.233 · Cited by 14
Qian, L., Zhuang, Z. G., Cheng, Y., Xia, Q., Zhang, J. J., & Xu, J. (2009) · Abdominal Imaging · doi:10.1007/s00261-009-9563-2 · Cited by 14
Comparison between Live and Photographed Slit Lamp Grading of Corneal Staining
Sorbara, L., Peterson, R. C., Schneider, S., & Woods, C. A. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000496 · Cited by 14
Crook, T. A., Armbya, N., Cleves, M. A., Badger, T. M., & Andres, A. (2012) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2012.08.020 · Cited by 16
Balleza, M., Alday, E. A. P., Vargas-Luna, M., & Riu, J. P. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.12.004 · Cited by 14
Halstead, J., Bergin, D., Keenan, A., Madden, J. M., & McGonagle, D. (2010) · Arthritis & Rheumatism · doi:10.1002/art.27547 · Cited by 14
A New Method to Record Subglottal Pressure Waves: Potential Applications
Neumann, K., Gall, V., Schutte, H. K., & Miller, D. G. (2003) · Journal of Voice · doi:10.1016/s0892-1997(03)00037-7 · Cited by 14
Test-retest reliability and circadian performance variability of a 15-s Wingate Anaerobic Test
Hachana, Y., Attia, A., Chaabène, H., Gallas, S., Sassi, R. H., & Dotan, R. (2011) · Biological Rhythm Research · doi:10.1080/09291016.2011.599634 · Cited by 18
Xu, S., Song, A., Nie, J., Li, X., Meng, S., Zhang, C., & Wang, Y. (2011) · Journal of Clinical Virology · doi:10.1016/j.jcv.2011.10.001 · Cited by 14
Computerized image analysis of the Ki‐67 proliferation index in mantle cell lymphoma
Blaker, Y. N., Brodtkorb, M., Maddison, J., Hveem, T. S., Nesheim, J. A., Mohn, H. M., Kolstad, A., Geisler, C. H., Liestøl, K., Smeland, E. B., et al. (2014) · Histopathology · doi:10.1111/his.12624 · Cited by 14
Automatic recognition of major fissures in human lungs
Wei, Q., Hu, Y., MacGregor, J. H., & Gelfand, G. (2011) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-011-0632-y · Cited by 14
Dobbyn, L., Gillgrass, T., McIntyre, G. T., Macfarlane, T. V., & Mossey, P. A. (2013) · The Cleft Palate-Craniofacial Journal · doi:10.1597/12-170 · Cited by 14
Henriksson, H., Forsum, E., & Löf, M. (2014) · British Journal Of Nutrition · doi:10.1017/s0007114513004406 · Cited by 18
Reliability of pulse oximetry in hypoxic newborn pigs
Solevåg, A. L., Dannevig, I., Benth, J. Š., Saugstad, O. D., & Nakstad, B. (2013) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2013.842550 · Cited by 15
Cauwenberghe, J. V., Delvaux, I., Michels, N., Hond, E. D., Schoeters, G. E. R., Nelen, V., Croes, K., Larebeke, N. V., & Sioen, I. (2014) · European Journal of Pediatrics · doi:10.1007/s00431-014-2274-x · Cited by 15
Høyer, C., Paludan, J. P. D., Pavar, S., Manresa, J. A. B., & Petersen, L. J. (2014) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2013.11.016 · Cited by 14
Reproducibility of rapid short echo time CSI at 3 tesla for clinical applications
Cauter, S. V., Sima, D. M., Luts, J., ter Beek, L., Ribbens, A., Peeters, R. R., Garcia, M. I. O., Li, Y., Sunaert, S. G., Gool, S. W. V., et al. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23820 · Cited by 14
The Conversion of Bulbar Redness Grades Using Psychophysical Scaling
Schulze, M., Hutchings, N., & SIMPSON, T. L. (2010) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181ce07f1 · Cited by 14
Comparison of Refractive Error Measures by the IRX3 Aberrometer and Autorefraction
McCullough, S. J., Little, J., Breslin, K. M. M., & Saunders, K. J. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000379 · Cited by 14
Naßenstein, K., Eberle, H. C., Maderwald, S., Jensen, C. J., Heilmaier, C., Schlosser, T. W., & Bruder, O. (2010) · European Radiology · doi:10.1007/s00330-010-1827-2 · Cited by 14
Automatic Quantification of Myocardial Infarction from Delayed Enhancement MRI
Valindria, V. V., Angue, M., Vignon, N., WALKER, P. M., Cochet, A., & Lalande, A. (2011) · International Conference on Signal-Image Technology & Internet-Based Systems (SITIS) · doi:10.1109/sitis.2011.83 · Cited by 14
Hammersley, J. A., Haughton, V. M., Wang, Y., & del Río, A. M. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3046 · Cited by 14
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.