STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 26,001–26,100 of 47,868
Cassia, E. V. S., Boswood, A., & Tordiffe, A. S. W. (2015) · Journal of Zoo and Wildlife Medicine · doi:10.1638/2014-0205.1 · Cited by 16
Proprioceptive acuity in the frontal and sagittal planes of the knee: a preliminary study
Cammarata, M. L., & Dhaher, Y. Y. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1757-3 · Cited by 14
Lupo, P. J., & Symanski, E. (2009) · Journal of the Air & Waste Management Association · doi:10.3155/1047-3289.59.11.1278 · Cited by 16
Axial Biometry of the Entire Eye Using Ultra-Long Scan Depth Optical Coherence Tomography
Zhong, J., Shao, Y., Tao, A., Jiang, H., Liu, C., Zhang, H., & Wang, J. (2013) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2013.09.033 · Cited by 14
Early onset preeclampsia and second trimester serum markers
Lambert-Messerlian, G. M., Palomaki, G. E., Neveux, L. M., Chien, E. K., Friedman, A., Rosene‐Montella, K., Hayes, M. K., & Canick, J. A. (2009) · Prenatal Diagnosis · doi:10.1002/pd.2387 · Cited by 15
Bayesian and Frequentist Methodologies for Analyzing Method Comparison Studies With Multiple Methods
Choudhary, P. K., & Yin, K. (2010) · Statistics in Biopharmaceutical Research · doi:10.1198/sbr.2010.08096 · Cited by 14
Cardiac Adaptation in Acute Hypertensive Pulmonary Edema
Margulescu, A. D., Rimbaş, R. C., Florescu, M., Dulgheru, R., Cintezǎ, M., & Vinereanu, D. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.01.359 · Cited by 14
Larsen, M., Pelzer, M., Friedrich, P. F., & Bishop, A. T. (2008) · Journal of Orthopaedic Research® · doi:10.1002/jor.20561 · Cited by 14
Mixed venous O2 saturation: Measured by co-oximetry versus calculated from P $$\bar v$$ o 2
Nierman, D. M., & Schechter, C. B. (1994) · The Journal of Clinical Monitoring · doi:10.1007/bf01651465 · Cited by 14
Validation and usefulness of the Sperm Quality Analyzer V equine for equine semen analysis
Hoogewijs, M., Vliegher, S. D., Schauwer, C. D., Govaere, J., Smits, K., Hoflack, G., de Kruif, A., & Soom, A. V. (2010) · Theriogenology · doi:10.1016/j.theriogenology.2010.08.003 · Cited by 14
Liu, Y., Beaucham, C. C., Pearce, T. A., & Zhuang, Z. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105769 · Cited by 14
Reinstein, D. Z., Morral, M., Gobbé, M., & Archer, T. J. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2012.05.045 · Cited by 14
Lazzer, S., Agosti, F., Col, A. D., Mornati, D., & Sartório, A. (2007) · Journal of Endocrinological Investigation · doi:10.1007/bf03346298 · Cited by 14
Free‐breathing myocardial perfusion MRI using SW‐CG‐HYPR and motion correction
Ge, L., Kino, A., Griswold, M. A., Carr, J., & Li, D. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22489 · Cited by 14
Suehiro, K., Tanaka, K., Yamada, T., Matsuura, T., Funao, T., Mori, T., & Nishikawa, K. (2014) · Anaesthesia · doi:10.1111/anae.12857 · Cited by 14
Self‐refraction Accuracy with Adjustable Spectacles among Children in Ghana
Ilechie, A. A., Abokyi, S., Owusu-Ansah, A., Boadi‐Kusi, S. B., Denkyira, A. K., & Abraham, C. H. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000561 · Cited by 14
Analyses of measurements taken from adult femurs of a British population
Porter, A. M. W. (1995) · International Journal of Osteoarchaeology · doi:10.1002/oa.1390050402 · Cited by 14
Comparison of a UL111a real‐time PCR and pp65 antigenemia for the detection of cytomegalovirus
Beckmann, C., Dumoulin, A., Rinaldo, C. H., & Hirsch, H. H. (2011) · Journal of Medical Virology · doi:10.1002/jmv.22232 · Cited by 14
Tasker, F., de Greeff, A., & Shennan, A. H. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2009.113 · Cited by 16
Bartel, T., Konorza, T. F. M., Barbieri, V., Erbel, R. M., Pachinger, O. M., & Müller, S. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.10.020 · Cited by 14
Szabados, L., Nagy, E. V., Ujhelyi, B., Urbancsek, H., Varga, J., Nagy, E., & Galuska, L. (2012) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32835c19f0 · Cited by 14
Reproducibility of left and right ventricular mass measurements with cardiac CT
Schwarz, F., Takx, R. A. P., Schoepf, U. J., Lee, Y. S., Ruzsics, B., Gassner, E.-M., Chiaramida, S. A., & Henzler, T. (2011) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2011.08.004 · Cited by 14
de Moura, W. C., de Araújo, H. P., Cabello, P. H., Romijn, P. C., & Leite, J. P. G. (2009) · Journal of Virological Methods · doi:10.1016/j.jviromet.2009.01.017 · Cited by 14
Perkins, G. A., Viel, L., Wagner, B., Hoffman, A. M., Erb, H. N., & Ainsworth, D. M. (2008) · Veterinary Immunology and Immunopathology · doi:10.1016/j.vetimm.2008.07.006 · Cited by 14
Agreement and Repeatability of an Infrared Thermometer
Kelechi, T. J., Good, A., & Mueller, M. (2011) · Journal of Nursing Measurement · doi:10.1891/1061-3749.19.1.55 · Cited by 15
Culp, W. C., Ball, T. R., & Burnett, C. J. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000287282.21055.db · Cited by 14
Li, Q., Ni, D., Yi, W., Chen, S.-P., Wang, T.-F., & Chen, X. (2013) · Ultrasound in Medicine and Biology · doi:10.1016/j.ultrasmedbio.2013.06.009 · Cited by 12
Clinical evaluation of a fully automated CMV PCR assay
Kerschner, H., Bauer, C. C., Schlag, P., Lee, S., Goedel, S., & Popow‐Kraupp, T. (2011) · Journal of Clinical Virology · doi:10.1016/j.jcv.2010.12.010 · Cited by 14
Tai, C.-C., Lu, F. L., Chen, P., Jeng, S., Chou, H., Chen, C., Tsao, P., & Hsieh, W. (2010) · Pediatrics & Neonatology · doi:10.1016/s1875-9572(10)60064-2 · Cited by 14
Flinck, M., Gradén, Å., Milde, H., Flinck, A., Hellström, M., Björk, J., & Nyman, U. (2010) · Acta Radiologica · doi:10.3109/02841851.2010.503663 · Cited by 14
Miyata, S., Noda, A., Nakata, S., Yagi, H., Yanagi, E., Honda, K., Sugiura, T., Nakai, S., Nakashima, T., & Koike, Y. (2007) · Sleep And Breathing · doi:10.1007/s11325-006-0091-9 · Cited by 15
Application of Vaginal Temperature Measurement in Bitches
Maeder, B., Arlt, S., Burfeind, O., & Heuwieser, W. (2012) · Reproduction in Domestic Animals · doi:10.1111/rda.12100 · Cited by 17
Evaluation of serum iohexol clearance for use in predicting carboplatin clearance in cats
Bailey, D. B., Rassnick, K. M., Prey, J. D., & Dykes, N. L. (2009) · American Journal of Veterinary Research · doi:10.2460/ajvr.70.9.1135 · Cited by 14
Moritz, R., Eaker, D. R., Langheinrich, A. C., Jorgensen, S. M., Bohle, R. M., & Ritman, E. L. (2010) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e3181bb0d32 · Cited by 14
Zaghloul, M. S., Mousa, A., Eldebawy, E., Attalla, E. M., Shafik, H., & Ezzat, S. (2010) · Clinical Oncology · doi:10.1016/j.clon.2010.08.006 · Cited by 14
Rais‐Bahrami, K., Rivera, O., Mikesell, G. T., & Short, B. L. (2002) · Journal of Perinatology · doi:10.1038/sj.jp.7210776 · Cited by 14
Daily polyphenol intake from fresh fruits in Portugal: contribution from berry fruits
Pinto, P., Cardoso, S. M., Pimpão, R. C., Tavares, L., Ferreira, R. B., & dos Santos, C. N. (2013) · International Journal of Food Sciences and Nutrition · doi:10.3109/09637486.2013.816938 · Cited by 18
Rose, J. B., Ellis, L. E., John, B., Martin, S., Gonska, T. Y., Solomon, M. P., Tullis, E. D., Corey, M. L., Adeli, K., & Durie, P. R. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.05.001 · Cited by 14
Development of the Asthma Treatment Satisfaction Measure
Martin, M. L., Patrick, D. L., Bushnell, D. M., Meltzer, E. O., Gutiérrez, B., & Parasuraman, B. M. (2009) · Current Medical Research and Opinion · doi:10.1185/03007990903158430 · Cited by 14
Ito, Y., Adachi, Y., Itazawa, T., Okabe, Y., Adachi, Y. S., Katsumuma, T., & Miyawaki, T. (2010) · Pediatric Pulmonology · doi:10.1002/ppul.21286 · Cited by 14
Evaluation of Various Rapid Chloride Tests for Assessing Urinary NaCl Excretion
Brüngel, M., Kluthe, R., & Fürst, P. (2001) · Annals of Nutrition and Metabolism · doi:10.1159/000046725 · Cited by 14
MacFarlane, J. A., Grove‐White, D., Royal, M. D., & Smith, R. F. (2014) · Veterinary Record · doi:10.1136/vr.102228 · Cited by 14
Comparing 6 and 10 sec exhalation time in exhaled nitric oxide measurements in children
Koopman, M., Arets, H. G. M., Uiterwaal, C. S. P. M., & van der Ent, C. K. (2009) · Pediatric Pulmonology · doi:10.1002/ppul.21006 · Cited by 15
Ford, J. J., Story, I. H., & McMeeken, J. M. (2008) · Manual Therapy · doi:10.1016/j.math.2008.02.010 · Cited by 14
A statistical approach to selecting and confirming validation targets in -omics experiments
Leek, J. T., Taub, M. A., & Rasgon, J. L. (2012) · BMC Bioinformatics · doi:10.1186/1471-2105-13-150 · Cited by 16
Frignani, R. R., Passos, M. A. Z., Ferrari, G., Niskier, S. R., Fisberg, M., & Cintra, I. D. P. (2014) · Jornal de Pediatria · doi:10.1016/j.jped.2014.07.009 · Cited by 17
Comparison of partial coherence interferometry and ultrasound for anterior segment biometry
Lara, F. J., Fernández‐Sánchez, V., López‐Gil, N., Cerviño, A., & Montés‐Micó, R. (2009) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2008.10.038 · Cited by 14
MDCT for Computerized Volumetry of Pneumothoraces in Pediatric Patients
Cai, W., Lee, E. Y., Vij, A., Mahmood, S. A., & Yoshida, H. (2011) · Academic Radiology · doi:10.1016/j.acra.2010.11.008 · Cited by 14
Wang, K., Yuan, M., Jiang, Y., Bao, Y., & Li, X. (2009) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2009.00636.x · Cited by 14
Edwards, A. M., Claxton, D. B., & Fysh, M. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0725-y · Cited by 14
Comparing analytic performance criteria: Evaluation of HbA1c certification criteria as an example
Rohlfing, C. L., Parvin, C. A., Sacks, D. B., & Little, R. R. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.03.034 · Cited by 14
Cardiovascular effects of carbon dioxide in ventilated preterm infants
Fenton, A. C., Woods, K., Leanage, R., Abu-Harb, M., Levene, M., Evans, D., & Field, D. (1992) · Acta Paediatrica · doi:10.1111/j.1651-2227.1992.tb12282.x · Cited by 14
Eppenga, W. L., Kramers, C., Derijks, H. J., Wensing, M., Wetzels, J. F. M., & Smet, P. A. G. M. D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0116403 · Cited by 20
Siński, M., Styczyński, G., & Szmigielski, C. A. (2012) · Hypertension Research · doi:10.1038/hr.2012.120 · Cited by 14
Sachse, D., Bolstad, N., Jonsson, M., Sæves, I., Johansson, C. B., Delezuch, W., Hagve, M., Hardang, I. M., Isaksson, H. S., Ivarsson, A., et al. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2012.677544 · Cited by 15
Whitmer, W. M., & Akeroyd, M. A. (2010) · Ear and Hearing · doi:10.1097/aud.0b013e318202b620 · Cited by 14
Lee, J. S., Nam, S. B., Chang, C. H., Han, D. W., Lee, Y. W., & Shin, C. S. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00698.x · Cited by 14
Rothe, A. V. E., Bielitzer, M., Meinertz, T., Limbourg, T., Ladwig, K., & Goette, A. (2013) · American Heart Journal · doi:10.1016/j.ahj.2013.05.020 · Cited by 14
Lower eyelid tensometry in younger and older normal subjects
Francis, I. C., Stapleton, F. J., Ehrmann, K., & Coroneo, M. T. (2005) · Eye · doi:10.1038/sj.eye.6701830 · Cited by 14
Zou, F., Jin, C., Ross, R. R., & Soller, B. R. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000748 · Cited by 16
Cronin, P., Kelly, A. M., Gross, B. H., Desjardins, B., Patel, S. V., Kazerooni, E. A., & Carlos, R. C. (2007) · Academic Radiology · doi:10.1016/j.acra.2007.01.023 · Cited by 14
Mazonakis, M., Grinias, E., Pagonidis, K., Tziritas, G., & Damilakis, J. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/4/015 · Cited by 14
Zochling, J., Nguyen, T. V., MARCH, L. M., & Sambrook, P. N. (2004) · Osteoporosis International · doi:10.1007/s00198-004-1594-5 · Cited by 14
Sampietro, D. A., Jimenez, C. M., Belizán, M., Vattuone, M. A., & Catalán, C. A. N. (2013) · Food Chemistry · doi:10.1016/j.foodchem.2013.06.069 · Cited by 14
Parametric Mean Survival Time Analysis in Gastric Cancer Patients
Maetani, S., Nakajima, T., & Nishikawa, T. (2004) · Medical Decision Making · doi:10.1177/0272989x04263253 · Cited by 14
Ichikawa, Y., Kitagawa, K., Kato, S., Dohi, K., Hirano, T., Ito, M., & Sakuma, H. (2014) · International journal of cardiac imaging · doi:10.1007/s10554-014-0387-y · Cited by 14
Mackie, R. T., Saunders, K. J., Day, R. E., Dutton, G. N., & McCulloch, D. L. (1996) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.1996.tb00604.x · Cited by 14
Hansen, C. T., Münster, A. B., Nielsen, L. C., Pedersen, P. T., & Abildgaard, N. (2012) · European Journal Of Haematology · doi:10.1111/ejh.12013 · Cited by 14
Yokoyama, N., & Ishimura, T. (2015) · Transplantation Proceedings · doi:10.1016/j.transproceed.2014.11.044 · Cited by 14
Development of a modified Winchester disability scale--the elderly at risk rating scale.
Donald, I. P. (1997) · Journal of Epidemiology & Community Health · doi:10.1136/jech.51.5.558 · Cited by 14
Dual wavefront sensing channel monocular adaptive optics system for accommodation studies
Hampson, K. M., Chin, S. S., & Mallen, E. A. H. (2009) · Optics Express · doi:10.1364/oe.17.018229 · Cited by 14
Šatalić, Z., Barić, I. C., Cecić, I., & Keser, I. (2007) · Nutrition Research · doi:10.1016/j.nutres.2007.07.001 · Cited by 15
Donadio, C., Calia, D., Ghimenti, S., Onor, M., Colombini, E., Fuoco, R., & Francesco, F. D. (2013) · Journal of Nephrology · doi:10.1007/s40620-013-0003-6 · Cited by 14
Okwuosa, T. M., Hampole, C. V., Ali, J., & Williams, K. A., Sr. (2009) · Journal of Nuclear Cardiology · doi:10.1007/s12350-009-9131-8 · Cited by 14
Motoneuron regeneration accuracy and recovery of gait after femoral nerve injuries in rats
Kruspe, M., Thieme, H., Guntinas‐Lichius, O., & Irintchev, A. (2014) · Neuroscience · doi:10.1016/j.neuroscience.2014.08.051 · Cited by 17
Doesch, C., Sperb, A., Sudarski, S., Loßnitzer, D., Rudic, B., Tülümen, E., Heggemann, F., Schimpf, R., Schoenberg, S. O., Borggrefe, M. M., et al. (2015) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2015.01.010 · Cited by 14
Tjørnild, M., Søballé, K., Bender, T., & Stilling, M. (2011) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2011.01.002 · Cited by 14
Kawamura, M., & Kawasaki, T. (2014) · Clinical and Experimental Hypertension · doi:10.3109/10641963.2014.913601 · Cited by 14
Karl, J. W., Taylor, J. J., & Bobo, M. (2014) · International Journal of Remote Sensing · doi:10.1080/01431161.2014.880820 · Cited by 14
Germundsson, J., & Lagali, N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-12533 · Cited by 14
Accuracy of Different Temperature Devices in the Postpartum Population
Hutton, S., Probst, E., Kenyon, C., Morse, D., Friedman, B., Arnold, K., & Helsley, L. (2009) · Journal of Obstetric, Gynecologic & Neonatal Nursing · doi:10.1111/j.1552-6909.2008.00302.x · Cited by 14
Pointer, J. S. (2008) · Journal of Optometry · doi:10.3921/joptom.2008.65 · Cited by 14
Ingle, L., Shelton, R. J., Rigby, A. S., Nabb, S., Clark, A., & Cleland, J. G. F. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.11.041 · Cited by 14
Huang, T., James, C. A., Tichnell, C., Murray, B. A., Xue, J. Q., Calkins, H. G., & Tereshchenko, L. G. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.03.009 · Cited by 14
Silver, H. J., Wall, R., Hollingsworth, E. K., Pruitt, A., Shotwell, M. S., & Simmons, S. F. (2012) · The journal of nutrition health & aging · doi:10.1007/s12603-012-0387-3 · Cited by 17
Validation of a two-compartment model of ventilation/perfusion distribution
Loeppky, J. A., Caprihan, A., Altobelli, S. A., Icenogle, M. V., Scotto, P., & Melo, M. F. V. (2005) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2005.06.002 · Cited by 14
Christoforidis, A., Perifanis, V., Papadopoulou, E., Dimitriadou, M., Kazantzidou, E., Vlachaki, E., & Tsatra, I. (2008) · European Journal Of Haematology · doi:10.1111/j.1600-0609.2008.01159.x · Cited by 14
Sen, B., Kesteven, P. J., & Avery, P. J. (2013) · Journal of Clinical Pathology · doi:10.1136/jclinpath-2013-201975 · Cited by 14
Armstrong, S., Miller, J. M., Benson, K., Jain, S., Panagopoulos, K., DeLancey, J. O. L., & Sampselle, C. M. (2006) · Neurourology and Urodynamics · doi:10.1002/nau.20299 · Cited by 17
Discrepancies between pediatric laboratories in pulmonary function results from healthy children
Paton, J. Y., Beardsmore, C., Laverty, A., King, C., Oliver, C., Young, D., & Stocks, J. (2011) · Pediatric Pulmonology · doi:10.1002/ppul.21592 · Cited by 14
Impact of Low and High Tidal Volumes on the Rat Alveolar Epithelial Type II Cell Proteome
Hirsch, J., Hansen, K. C., Sapru, A., Frank, J. A., Chalkley, R. J., Fang, X., Trinidad, J. C., Baker, P. R., Burlingame, A. L., & Matthay, M. A. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200605-621oc · Cited by 14
Sprackman, L., Dakin, S. G., May, S. A., & Weller, R. (2015) · The Veterinary Journal · doi:10.1016/j.tvjl.2015.01.006 · Cited by 14
Comparisons of four dietary assessment methods during pregnancy in Taiwanese women
Lyu, L.-C., Hsu, Y.-N., Chen, H.-F., Lo, C.-C., & Lin, C.-L. (2014) · Taiwanese Journal of Obstetrics and Gynecology · doi:10.1016/j.tjog.2014.04.007 · Cited by 16
Rouatbi, S., Saad, H. B., Latiri, I., Tabka, Z., & Guénard, H. J.-P. (2010) · Respiration · doi:10.1159/000316339 · Cited by 14
Thrippleton, M. J., Munro, K. I., McKillop, G., Newby, D. E., Marshall, I., Roberts, N., & Critchley, H. (2014) · Reproductive Sciences · doi:10.1177/1933719114553451 · Cited by 14
Pinilla, I., García‐Martín, E., Idoipe, M., Sancho, E., & Fuertes, I. (2012) · Journal of Ophthalmology · doi:10.1155/2012/107053 · Cited by 14
Acuity measurements in adult subjects using a preferential looking test
Woodhouse, J. M., Morjaria, S. A., & Adler, P. M. (2007) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2006.00454.x · Cited by 14
Robust, Standardized Quantification of Pulmonary Emphysema in Low Dose CT Exams
Ceresa, M., Bastarrika, G., de-Torres, J. P., Montuenga, L. M., Zulueta, J. J., Ortíz-de-Solórzano, C., & Muñoz‐Barrutia, A. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.06.015 · Cited by 14
Programa Saúde da Família: acerca da adequação do uso do seu indicador de cobertura
Aquino, R., & Barreto, M. L. (2008) · Cadernos de Saúde Pública · doi:10.1590/s0102-311x2008000400022 · Cited by 14
Muscle sympathetic baroreflex sensitivity is different at rest and during evoked hypotension
Kienbaum, P., & Peters, J. (2004) · Basic Research in Cardiology · doi:10.1007/s00395-003-0452-5 · Cited by 14
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.