STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 26,401–26,500 of 47,868
Fanti, Z., De‐Miguel, F. F., & Martínez-Pérez, M. E. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649377 · Cited by 17
Lembcke, A. E., Wiese, T. H., Enzweiler, C., Kivelitz, D. E., Dushe, S., Dohmen, P. M., Borges, A. C., Rogalla, P., & Hamm, B. (2003) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200305000-00015 · Cited by 14
Measurement of Concentration and Viability in Stallion Sperm
Love, C. C. (2012) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2012.06.015 · Cited by 14
Wenzel, U., Wauer, R. R., Wagner, M. H., & Schmalisch, G. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/83.3.503 · Cited by 14
Lange, A., Palka, P., Nowicki, A., Olszewski, R., Anderson, T. T., Adamus, J., Sutherland, G. R., & Fox, K. A. A. (1998) · American Heart Journal · doi:10.1016/s0002-8703(98)70061-4 · Cited by 14
Smith, M. R., Fuchs, V., Anderson, E. J., Fallon, M. A., & Manola, J. B. (2002) · Nutrition · doi:10.1016/s0899-9007(02)00821-3 · Cited by 16
Non-invasive ultrasonic cardiac output monitoring in exercise testing
Knobloch, K., Höltke, V., Jakob, E., Vogt, P. M., & Phillips, R. A. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.053 · Cited by 14
Lin, S. C., Whipple, D. M., & Ho, C. S. (1998) · Communication in Statistics- Theory and Methods · doi:10.1080/03610929808832167 · Cited by 14
Portable electrochemical blood uric acid meter
Kuo, C., Hwu, C., Lin, Y., Huang, Y., Kao, W., Weih, M. J., Hsiao, L., Kwok, C., & Ho, L.-T. (2002) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.10030 · Cited by 14
Interchangeability of Activated Clotting Time Values Across Different Point-of-Care Systems
Thenappan, T., Swamy, R. S., Shah, A. P., Nathan, S., Nichols, J., Bond, L., & Jolly, N. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.12.033 · Cited by 14
Imran, M. K., Ismail, A. A., Naing, L., & Mohamad, W. B. W. (2007) · PubMed · Cited by 14
Regression models to predict hip joint centers in pathological hip population
Mantovani, G., Ng, K. C. G., & Lamontagne, M. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.11.001 · Cited by 15
White, J., Withers, K. L., Lencioni, M., Carolan‐Rees, G., Wilkes, A. R., Wood, K., Patrick, H. E., Cunningham, D., & GRIFFITH, M. J. (2015) · Quality of Life Research · doi:10.1007/s11136-015-1194-1 · Cited by 15
Dynamic Attention as a Predictor of Driving Performance in Clinical Populations: Preliminary Results
Bowers, A. R., Anastasio, J., Howe, P. D. L., O’Connor, M. G., Hollis, A., Kapust, L. R., Bronstad, M., & Horowitz, T. S. (2011) · International Driving Symposium on Human Factors in Driver Assessment, Training and Vehicle Design (Driving Assessment Conference) · doi:10.17077/drivingassessment.1413 · Cited by 14
18F-fluoroethylcholine uptake in arterial vessel walls and cardio vascular risk factors
Rominger, A., Saam, T., Wolpers, S., Nikolaou, K., Cumming, P. D., Reiser, M. F., Bartenstein, P., Hacker, M., & Förster, S. (2010) · Nuklearmedizin - NuclearMedicine · doi:10.3413/nukmed-0299 · Cited by 14
D’ambrosio, A., Tiessen, A., & Simpson, J. R. (2012) · Canadian Journal of Dietetic Practice and Research · doi:10.3148/73.1.2012.40 · Cited by 18
99mTc-albumin can replace125I-albumin to determine plasma volume repeatedly
Bonfils, P. K., Damgaard, M., Stokholm, K. H., & Nielsen, S. L. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2012.688856 · Cited by 14
Ding, X., Huang, Q., Zheng, Y., Jiang, Y., Huang, W., & He, M. (2012) · Cornea · doi:10.1097/ico.0b013e31820e42b5 · Cited by 14
Blohm, M. E. G., Hartwich, J., Obrecht, D., Kersten, J. F., & Singer, D. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9878-9 · Cited by 16
Potger, K. C., McMillan, D., Southwell, J., Dando, H., & O’Shaughnessy, K. (2003) · Journal of ExtraCorporeal Technology · doi:10.1051/ject/2003353218 · Cited by 14
Tracking body core temperature in military thermal environments: An extended Kalman filter approach
Seng, K., Chen, Y., Chai, K. M. A., Wang, T., Fun, D. C. Y., Teo, Y. S., Tan, P. M. S., Ang, W. H., & LEE, J. K. W. (2016) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2016.7516277 · Cited by 14
Acute effect of coffee consumption on arterial stiffness, evaluated using an oscillometric method
Echeverri, D., Pizano, A., Montes, F. R., & Forcada, P. J. (2017) · Artery Research · doi:10.1016/j.artres.2017.01.001 · Cited by 15
Determinants of Indices of Cerebral Volume in Former Very Premature Infants at Term Equivalent Age
Naud, A., Schmitt, E., Wirth, M., & Hascoët, J. (2017) · PLoS ONE · doi:10.1371/journal.pone.0170797 · Cited by 15
Wåhlberg, H., Valle, P. C., Malm, S., Hovde, Ø., & Broderstad, A. R. (2017) · BMC Health Services Research · doi:10.1186/s12913-017-2127-1 · Cited by 15
Mueller, J. H., Raisi, H., Rausch, V., Peccerella, T., Simons, D., Ziener, C. H., Schlemmer, H.-P., Seitz, H. K., Waldburger, N., Longerich, T., et al. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2017.04.019 · Cited by 14
Smith, A. K., By, S., Lyttle, B. D., Dortch, R. D., Box, B. A., McKeithan, L. J., Thukral, S., Bagnato, F. R., Pawate, S., & Smith, S. A. (2017) · NeuroImage Clinical · doi:10.1016/j.nicl.2017.07.010 · Cited by 14
Khushaba, R. N., Armitstead, J. P., & Schindhelm, K. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037128 · Cited by 15
Evaluation of three measures of cardiorespiratory fitness in independently ambulant stroke survivors
Dunn, A., Marsden, D. L., Barker, D., van Vliet, P., Spratt, N. J., & Callister, R. (2018) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2018.1457746 · Cited by 14
Amakpe, F., Smet, L. D., Brunain, M., Jacobs, F. J., SINSIN, B. A., & de Graaf, D. C. (2018) · Journal of Apicultural Science · doi:10.2478/jas-2018-0006 · Cited by 14
Salaffi, F., Carlo, M. D., Carotti, M., & Farah, S. (2018) · Pain Research and Management · doi:10.1155/2018/3496846 · Cited by 17
Brincks, J., Callesen, J., Dalgas, U., & Johnsen, E. (2019) · Clinical Rehabilitation · doi:10.1177/0269215518803144 · Cited by 14
Yoo, S., Ahn, J., Cserey, G., Lee, H., & Seo, J.-M. (2019) · Sensors · doi:10.3390/s19071744 · Cited by 14
Longitudinal Monitoring of Athletes: Statistical Issues and Best Practices
Bailey, C. (2019) · Journal of Science in Sport and Exercise · doi:10.1007/s42978-019-00042-4 · Cited by 18
Abbott, I. J., van Gorp, E., Wijma, R. A., Dekker, J., Croughs, P. D., Meletiadis, J., Mouton, J. W., & Peleg, A. Y. (2020) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkaa127 · Cited by 14
Ortín-Bustillo, A., Tvarijonaviciute, A., Cerón, J. M. C., Contreras-Aguilar, M. D., Martínez-Miró, S., Martı́nez-Subiela, S., Tecles, F., & Muñoz-Prieto, A. (2021) · Research in Veterinary Science · doi:10.1016/j.rvsc.2021.10.013 · Cited by 14
Abdominal Compartment Syndrome
Malbrain, M. L. N. G., Regenmortel, N. V., & Cheatham, M. L. (2007) · Springer eBooks · doi:10.1007/978-0-387-49518-7_55 · Cited by 15
Karabatsas, C. H., Papaefthymiou, I., Aslanides, I. M., & Chatzoulis, D. (2005) · European Journal of Ophthalmology · doi:10.1177/112067210501500102 · Cited by 14
Chow, T. W., Takeshita, S., Honjo, K., Pataky, C. E., Jacques, P. L. S., Kusano, M., Caldwell, C. B., Ramirez, J., Black, S. E., & Verhoeff, N. P. L. G. (2007) · BMC Nuclear Medicine · doi:10.1186/1471-2385-7-2 · Cited by 16
S -Nitrosoalbumin and Other S -Nitrosothiols in the Blood: Is Their Quantity of No Relevance?
Tsikas, D. (2004) · Circulation Research · doi:10.1161/res.94.12.e106 · Cited by 14
Lee, L.-C., Hsieh, K.-C., Wu, C.-S., Chen, Y.-J., Chiang, J., & Chen, Y.-Y. (2014) · International journal of gerontology · doi:10.1016/j.ijge.2013.08.010 · Cited by 15
Safran, A. B., Mermillod, B., Mermoud, C., de Weisse, C., & Desangles, D. (1993) · Neuro-Ophthalmology · doi:10.3109/01658109309044579 · Cited by 14
van den Berg, M. H. (1999) · The Netherlands Journal of Medicine · doi:10.1016/s0300-2977(99)00031-5 · Cited by 14
Clavier, N., Schurando, P., Raggueneau, J. L., & Payen, D. M. (1997) · Journal of Critical Care · doi:10.1016/s0883-9441(97)90040-x · Cited by 14
Comparison of two methods of measurement of whole blood glucose in the neonatal period
Sharief, N., & Hussein, K. (1997) · Acta Paediatrica · doi:10.1111/j.1651-2227.1997.tb14855.x · Cited by 14
Schütt, S., Horn, P., Roth, H. R., Quintel, M., Schilling, L., Schmiedek, P., & Schürer, L. (2001) · Journal of Neurotrauma · doi:10.1089/089771501750291837 · Cited by 14
Comparing two clinical measurements: a linear mixed model approach
Lai, D., & Shiao, S.-Y. P. K. (2005) · Journal of Applied Statistics · doi:10.1080/02664760500080157 · Cited by 14
Szeto, C., Leung, C. B., Wong, T. Y. ‐., Chow, K., Wang, A. Y.-M., Lui, S., & Li, P. K.-T. (2003) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.2003.01121.x · Cited by 14
Bone Mineral Density in the Lumbar Spine as Determined by Dual-Energy X-Ray Absorptiometry
Nysom, K., Mølgaard, C., & Michaelsen, K. F. (1998) · Acta Radiologica · doi:10.3109/02841859809175488 · Cited by 14
Keegan, J., Horkaew, P., Buchanan, T. J., Smart, T. S., Yang, G., & Firmin, D. N. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20094 · Cited by 14
Between-laboratory comparison of densitometry and bio-electrical impedance measurements
Deurenberg, P., Westerterp, K. R., & Wierik, E. J. M. V.-T. (1994) · British Journal Of Nutrition · doi:10.1079/bjn19940140 · Cited by 17
Kopman, A. F., Chin, W. A., & Moe, J. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00641.x · Cited by 14
Goldmann-Applanationstonometrie und dynamische Konturtonometrie
mann, E. M. H., Pfeiffer, N., Barleon, L., & Grus, F. H. (2006) · Der Ophthalmologe · doi:10.1007/s00347-006-1318-7 · Cited by 14
Evaluation of three brands of tympanic thermometer.
Hoffman, C., Boyd, M., Briere, B., Loos, F., & Norton, P. J. (1999) · Bond University Research Portal (Bond University) · Cited by 18
Measurement of natural killer cell cytotoxicity by area under a cytotoxic curve
Sheeran, T. P., Jackson, F. R., Dawes, P. T., Collins, M., & Shadforth, M. F. (1988) · Journal of Immunological Methods · doi:10.1016/0022-1759(88)90314-6 · Cited by 14
Validation of reflectance pulse oximetry: an evaluation of a new sensor in piglets.
Nijland, R., Nierlich, S., Jongsma, H. W., Nijhuis, J. G., Oeseburg, B., Springer, K., & Mannheimer, P. D. (1997) · The Journal of Clinical Monitoring · doi:10.1023/a:1007332105965 · Cited by 16
Hoyos, M. H., Orkisz, M., Douek, P., & Magnin, I. E. (2005) · HAL · Cited by 14
Functional capacity evaluation in patients with chronic low back pain: reliability and validity
Reneman, M. F. (2004) · University of Groningen research database (University of Groningen / Centre for Information Technology) · Cited by 14
Rossi, P., Oldner, A., Wanecek, M., Leksell, L. G., Rudehill, A., Konrad, D., & Weitzberg, E. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1604-z · Cited by 14
Hübler, M., Souders, J. E., Shade, E. D., Hlastala, M. P., Polissar, N. L., & Glenny, R. W. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.6.2381 · Cited by 14
Wessig, K., Hollinger, S., Schmalzhaf, I., & Lenz, T. (2000) · Blood Pressure Monitoring · doi:10.1097/00126097-200008000-00008 · Cited by 14
Inhalation challenge in ASA-induced asthma
Dahlén, B., & Melillo, G. (1998) · Respiratory Medicine · doi:10.1016/s0954-6111(98)90279-7 · Cited by 14
Takalo, R., Piirilä, P. L., & Sovijärvi, A. R. A. (2008) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510802621158 · Cited by 16
Evaluation of a computerised polysomnography system.
Biernacka, H., & Douglas, N. J. (1993) · Thorax · doi:10.1136/thx.48.3.280 · Cited by 14
Höcker, M. R., Schmidt, W. E., Creutzfeldt, W., Choudhury, A. R., Nustede, R., Schafmayer, A., & Fölsch, U. R. (1992) · Regulatory Peptides · doi:10.1016/0167-0115(92)90619-6 · Cited by 14
Ortí, M. R., Rioboó, E. M., Moreno, A. D., Baena, B. A., Simón, M. M., Medina, A. T., & del Pozo, F. J. F. (2001) · Atención Primaria · doi:10.1016/s0212-6567(01)78802-6 · Cited by 14
Simultaneous measurement of catecholamines and kallikrein in urine using boric acid preservative
Lee, Z. S. K., & Critchley, J. (1998) · Clinica Chimica Acta · doi:10.1016/s0009-8981(98)00105-3 · Cited by 14
Nowinski, K., & Bergfeldt, L. (1995) · Cardiovascular Drugs and Therapy · doi:10.1007/bf00878089 · Cited by 14
Functional residual capacity to thoracic gas volume (FRC:TGV) ratio in healthy neonates
Yuksel, B., & Greenough, A. (1995) · Respiratory Medicine · doi:10.1016/0954-6111(95)90212-0 · Cited by 14
Oxygen Saturation in Children in the Postoperative Period
Tyler, D. C., Woodham, M., Stocks, J., Leary, A., & Lloyd-Thomas, A. R. (1995) · Anesthesia & Analgesia · doi:10.1097/00000539-199501000-00004 · Cited by 14
Winter, O., SUTTER, J. D., & Dierckx, R. A. J. O. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0828-z · Cited by 14
X-ray densitometry for the measurement of regional myocardial perfusion
Haude, M., Caspari, G., Baumgart, D., Ehring, T., Schulz, R., Roth, T., Koch, L., Erbel, R. M., Spiller, P., & Heusch, G. (2000) · Basic Research in Cardiology · doi:10.1007/s003950050189 · Cited by 14
Kos, J., & Bättig, K. (1996) · Journal of the American Dietetic Association · doi:10.1016/s0002-8223(96)00083-1 · Cited by 14
Comparison of two reflectance photometers in the assessment of neonatal hypoglycaemia.
Kirkham, P., & Watkins, A. N. (1995) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.73.3.f170 · Cited by 14
A METHOD FOR MEASURING TIDAL VOLUME DURING HIGH FREQUENCY JET VENTILATION
Young, D., & Sykes, M. K. (1988) · British Journal of Anaesthesia · doi:10.1093/bja/61.5.601 · Cited by 14
Witjes, W. P. J., de la Rosette, J. J. M. C. H., Zerbib, M., Vignoli, G., Geffriaud, C., Debruyne, F. M. J., & Wijkstra, H. (1998) · European Urology · doi:10.1159/000019533 · Cited by 14
Lindegaard, M. W., Aass, N., Bue, E., Theodorsen, L., & Fosså, S. D. (1991) · British Journal of Cancer · doi:10.1038/bjc.1991.317 · Cited by 14
Schimmel, C., Frazer, D., Huckins, S. R., & Glenny, R. W. (2000) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00057-2 · Cited by 14
Ford, P., & McCormack, B. G. (1999) · Journal of Clinical Nursing · doi:10.1046/j.1365-2702.1999.00332.x · Cited by 19
Wenker, C. J., Hunziker, D., Lopez, J., Oppliger, H., Forrer, R. S., & Lutz, H. (2007) · Zentralblatt für Veterinärmedizin Reihe A · doi:10.1111/j.1439-0442.2007.00903.x · Cited by 14
Dötsch, J., Demirakça, S., Hahn, D., Katz, N. R., Kühl, P. G., & Rascher, W. (1999) · Critical Care Medicine · doi:10.1097/00003246-199906000-00051 · Cited by 15
Nakamura, K., Funabashi, N., Uehara, M., Suzuki, K., Terao, M., Okubo, K., Mita, Y., Maeda, F., & Komuro, I. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.06.060 · Cited by 14
Transesophageal versus intracoronary Doppler measurements for calculation of coronary flow reserve
Zehetgruber, M. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00166-1 · Cited by 14
Erntell, M., Myhre, E. B., & Kronvall, G. (1986) · Acta Pathologica Microbiologica Scandinavica Section B Microbiology · doi:10.1111/j.1699-0463.1986.tb03071.x · Cited by 14
Neuhäuser, C., Müller, M. C., Bräu, M. E., Scholz, S., Böning, O., Roth, P., & Hempelmann, G. (2002) · Der Anaesthesist · doi:10.1007/s00101-002-0354-1 · Cited by 14
Lubega, J., & Davies, T. J. (1990) · Clinica Chimica Acta · doi:10.1016/0009-8981(90)90146-j · Cited by 14
Viscous fluid expulsion in the evaluation of the constipated patient
Alstrup, N. I., Råholt, C., Fu, C., Rasmussen, O., Sørensen, M., & Christiansen, J. (1997) · Diseases of the Colon & Rectum · doi:10.1007/bf02055383 · Cited by 14
The need to develop guidelines for the evaluation of medical image processing procedures
Buvat, I., Chameroy, V., Aubry, F., Pélégrini‐Issac, M., Fakhri, G. E., Huguenin, C., Benali, H., Todd-Pokropek, A. E., & Paola, R. D. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.348547 · Cited by 14
Huber, D., Osthaus, W. A., Optenhöfel, J., Breymann, T., Marx, G., Piepenbrock, S., & Sümpelmann, R. (2006) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2006.01980.x · Cited by 14
Evaluation of ultrafast phase-contrast imaging in the thoracic aorta
Debatin, J. F., Davis, C. P., Felblinger, J., & McKinnon, G. C. (1995) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf01709848 · Cited by 14
Wolstenhulme, S., Evans, J., & Weston, M. J. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.838.9404209 · Cited by 14
Langenhove, G. V., Hamburger, J., Smits, P., Albertal, M., Onderwater, E., Kay, I. P., & Serruys, P. W. J. C. (2000) · American Heart Journal · doi:10.1067/mhj.2000.108827 · Cited by 14
Corwin, M. J., Lister, G., Silvestri, J. M., Peucker, M., Brooks, L. J., Ward, S. L. D., Hunt, C. E., Neuman, M. R., Crowell, D. H., & Colton, T. (1998) · Pediatric Research · doi:10.1203/00006450-199811000-00010 · Cited by 14
A device for phototesting patients before PUVA therapy
Diffey, B. L., BERKER, D. A. R., SAUNDERS, P. J., & Farr, P. M. (1993) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1993.tb03335.x · Cited by 14
Mitra, S., Plank, L. D., Knight, G. S., & Hill, G. L. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/1/012 · Cited by 14
The determination of INR in stored whole blood.
Leeming, D. R., Craig, S., Stevenson, K. J., & Taberner, D. A. (1998) · Journal of Clinical Pathology · doi:10.1136/jcp.51.5.360 · Cited by 14
Prentice, D., & Moreland, J. (1999) · Geriatric Nursing · doi:10.1053/gn.1999.v20.103926001 · Cited by 14
An ultrafiltration catheter for monitoring of venous lactate and glucose around myocardial ischemia
Tiessen, R. G., Tio, R. A., Hoekstra, A., Venema, K., & Korf, J. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00146-9 · Cited by 14
Thuret, G., Deb-Joardar, N., Manissolle, C., Zhao, M., Péoc’h, M., Gain, P., & Gavet, Y. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2006.099614 · Cited by 14
Aerobic and functional capacity in a group of healthy women: reference values and repeatability
Wisén, A. G. M., & Wohlfart, B. (2004) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2004.00576.x · Cited by 15
Herrejón, A., Inchaurraga, I., Palop, J., Ponce, S., Peris, R. A., Terrádez, M., & Blanquer, R. (2006) · Archivos de Bronconeumología · doi:10.1016/s1579-2129(06)60450-3 · Cited by 14
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.