STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 28,901–29,000 of 47,868
Cysouw, M. C. F., Kramer, G. M., Heijtel, D., Schuit, R. C., Morris, M. J., van den Eertwegh, A. J. M., Voortman, J., Hoekstra, O. S., Oprea‐Lager, D. E., & Boellaard, R. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0531-8 · Cited by 11
Chepchirchir, B. S., Zhou, X., Paschke, A., & Schüürmann, G. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.134056 · Cited by 12
Borik, A., Staňová, A. V., Kodešová, R., Brooks, B. W., Grabicová, K., Nováková, P., & Grabic, R. (2019) · Talanta · doi:10.1016/j.talanta.2019.120382 · Cited by 11
Cekic, N. D., Savic, S. M., & Savic, S. D. (2019) · Drug Development and Industrial Pharmacy · doi:10.1080/03639045.2019.1672718 · Cited by 11
Hijkoop, A., Lap, C. C. M. M., Aliasi, M., Mulder, E. J. H., Kramer, W. L. M., BROUWERS, H. A. A., van Baren, R., Pajkrt, E., van Kaam, A. H., Bilardo, C. M., et al. (2019) · Prenatal Diagnosis · doi:10.1002/pd.5568 · Cited by 11
Gor-García-Fogeda, M. D., Tomé‐Redondo, S., Simón‐Hidalgo, C., Daly, J. J., Rueda, F. M., & Cano‐de‐la‐Cuerda, R. (2019) · PM&R · doi:10.1002/pmrj.12264 · Cited by 14
Measurement accuracy of two professional-use systems for point-of-care testing of blood glucose
Baumstark, A., Jendrike, N. R. M., Kamecke, U., Liebing, C., Pleus, S., & Freckmann, G. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0549 · Cited by 14
Sigmundsson, T. S., Öhman, T., Hallbäck, M., Redondo, E., Suárez-Sipmann, F., Wallin, M. K. E. B., Oldner, A., Hällsjö-Sander, C., & Björne, H. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00421-w · Cited by 11
Alshaikheid, M., Chaabane, A., Fredj, N. B., Brahim, H. B., Fadhel, N. B., Chadli, Z., Slama, A., Boughattas, N. A., Chakroun, M., & Aouam, K. (2019) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1111/jcpt.13098 · Cited by 11
Community volunteer assessment of recreational water quality in the Hutt River, Wellington
Valois, A. E., Milne, J. R., Heath, M. W., Davies‐Colley, R. J., Martin, E., & Stott, R. (2019) · New Zealand Journal of Marine and Freshwater Research · doi:10.1080/00288330.2019.1700136 · Cited by 12
Grèze, C., Guttmann, A., Pons‐Rejraji, H., Vasson, M., Lornage, J., Ouchchane, L., & Brugnon, F. (2019) · Basic and Clinical Andrology · doi:10.1186/s12610-019-0098-2 · Cited by 11
Płonka, M., Bociaga, M., Radoń-Pokracka, M., Nowak, M., & Huras, H. K. (2020) · Ginekologia Polska · doi:10.5603/gp.2020.0005 · Cited by 14
Shima, H., Tanabe, N., Satô, S., Oguma, T., Kubo, T., Kozawa, S., Koizumi, K., Watanabe, A., Sato, A., Togashi, K., et al. (2020) · Respiratory Investigation · doi:10.1016/j.resinv.2020.01.001 · Cited by 11
Jhang, W. K., & Park, S. J. (2020) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000002335 · Cited by 11
Wajs, E., Rughoobur, G., Burling, K., George, A., Flewitt, A. J., & Gnanapragasam, V. J. (2020) · Nanoscale · doi:10.1039/d0nr00416b · Cited by 11
Hoque, A., Gallagher, K., McEntegart, A., Porter, D. R., Steultjens, M. P. M., Woodburn, J., & Hendry, G. (2021) · Arthritis Care & Research · doi:10.1002/acr.24259 · Cited by 13
Navarro‐Flores, E., Losa‐Iglesias, M. E., Vallejo, R., Reina‐Bueno, M., López‐López, D., Morales, C. R., Palomo‐López, P., & Calvo‐Lobo, C. (2020) · International Wound Journal · doi:10.1111/iwj.13400 · Cited by 11
Hjordt, L. V., Ozenne, B., Armand, S., Dam, V. H., Jensen, C. G., Köhler‐Forsberg, K., Knudsen, G. M., & Stenbæk, D. S. (2020) · Frontiers in Psychology · doi:10.3389/fpsyg.2020.00961 · Cited by 14
Vaganée, D., de Borne, S. V., der Zalm, P. V., Voorham, J. C., Fransén, E., & Wachter, S. D. (2020) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.13177 · Cited by 11
Arad, A. D., Bishop, K., Adimoolam, D., Albu, J., & DiMenna, F. J. (2020) · PLoS ONE · doi:10.1371/journal.pone.0235567 · Cited by 12
Local staging of ipsilateral breast tumor recurrence: mammography, ultrasound, or MRI?
Walstra, C. J. E. F., Schipper, R., Winter-Warnars, G. A. O., Loo, C. E., Voogd, A. C., Peeters, M.-J. T. F. D. V., Nieuwenhuijzen, G. A. P., & Beets‐Tan, R. G. H. (2020) · Breast Cancer Research and Treatment · doi:10.1007/s10549-020-05850-9 · Cited by 11
Barrett, S., Simpkin, A. J., Walls, G., Leech, M., & Marignol, L. H. (2020) · Clinical Oncology · doi:10.1016/j.clon.2020.07.019 · Cited by 14
Aykanat, V. M., Broadbent, E., & Peyton, P. J. (2020) · Anaesthesia · doi:10.1111/anae.15248 · Cited by 13
A novel approach to measuring wobble board performance in individuals with chronic ankle instability
Fusco, A., Fuchs, P. X., Maio, M. D., Wagner, H., & Cortis, C. (2020) · Heliyon · doi:10.1016/j.heliyon.2020.e04937 · Cited by 13
Erichsen, J. L., Jensen, C., Larsen, M. S., Damborg, F., & Viberg, B. L. (2020) · Foot and Ankle Surgery · doi:10.1016/j.fas.2020.06.014 · Cited by 12
Obel, L. M., Lindholt, J. S., Leetmaa, T. H., Dahl, J. S., Møller, J. E., Steffensen, F. H., Frost, L., Lambrechtsen, J., Busk, M., Urbonavičienė, G., et al. (2020) · International journal of cardiac imaging · doi:10.1007/s10554-020-02081-3 · Cited by 12
Cipolletta, E., Filippucci, E., Matteo, A. D., Tesei, G., Cosatti, M. A., Carlo, M. D., & Grassi, W. (2020) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-1285-4602 · Cited by 11
Hoyer, D., Schmidt, A., Pytlik, A., Viehöfer, L., Gonçalves, H. M. D. S. L. M., Amorim‐Costa, C., Bernardes, J., Ayres‐de‐Campos, D., Lobmaier, S. M., & Schneider, U. (2020) · Physiological Measurement · doi:10.1088/1361-6579/abc791 · Cited by 12
Mapping the rest of the human connectome: Atlasing the spinal cord and peripheral nervous system
Irimia, A., & Horn, J. D. V. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117478 · Cited by 15
Clouthier, S. C., Schroeder, T., Bueren, E. K., Anderson, E., & Emmenegger, E. J. (2020) · Diseases of Aquatic Organisms · doi:10.3354/dao03564 · Cited by 11
Yamashita, L. M., Corona, L. P., Silva, E. D., de Mendonça, A. P. M., de Assumpção, D., Filho, A. D. A. B., Barrett, J. S., Geloneze, B., & Vasques, A. C. J. (2020) · Clinical Nutrition · doi:10.1016/j.clnu.2020.11.021 · Cited by 13
Schoos, A., Spiegelaere, W. D., Cools, A., Pardon, B., Audenhove, E. V., Bernaerdt, E., Janssens, G., & Maes, D. G. D. (2020) · animal · doi:10.1016/j.animal.2020.100041 · Cited by 11
Camarda, A. J., Durand, R., Benkarim, M., Rompre, P. H., Guertin, G., & Ciaburro, H. (2021) · Clinical Oral Implants Research · doi:10.1111/clr.13699 · Cited by 12
Kato, N., Yuki, I., Otani, K., Ishibashi, T., Kakizaki, S., Nagayama, G., Maruyama, F., Ikemura, A., Kan, I., Kodama, T., et al. (2021) · World Neurosurgery · doi:10.1016/j.wneu.2020.12.068 · Cited by 11
Reliability of Human Achilles Tendon Stiffness Measures Using Freehand 3-D Ultrasound
Merza, E. Y., Pearson, S. J., Lichtwark, G. A., Garofolini, A., & Malliaras, P. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.01.002 · Cited by 13
Population-based input function for TSPO quantification and kinetic modeling with [11C]-DPA-713
Akerele, M. I., Zein, S. A., Pandya, S., Nikolopoulou, A., Gauthier, S. A., Raj, A., Henchcliffe, C., Mozley, P. D., Karakatsanis, N. A., Gupta, A. K., et al. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00381-8 · Cited by 11
Niem, T., Gonschorek, S., & Wöstmann, B. (2021) · Dental Materials · doi:10.1016/j.dental.2020.12.012 · Cited by 11
Barwick, T. D., Orton, M. R., Koh, D., Kaiser, M., Rockall, A., Tunariu, N., Blackledge, M., & Messiou, C. (2021) · British Journal of Radiology · doi:10.1259/bjr.20200682 · Cited by 12
Machino, M., Ando, K., Kobayashi, K., Nakashima, H., Tanaka, S. A., Kanbara, S., Ito, S., Inoue, T., Koshimizu, H., Seki, T., et al. (2021) · BioMed Research International · doi:10.1155/2021/6622398 · Cited by 11
Prill, R., Becker, R., Schulz, R., Michel, S. C. A., & Hommel, H. (2021) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-021-06570-3 · Cited by 11
Bashir, N. S., Walters, T. D., Griffiths, A. M., & Ungar, W. J. (2021) · Children · doi:10.3390/children8050343 · Cited by 12
Katewongsa, P., Potharin, D., Rasri, N., Palakai, R., & Widyastari, D. A. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18094467 · Cited by 16
Measuring Tailbeat Frequencies of Three Fish Species from Adaptive Resolution Imaging Sonar Data
Helminen, J., O’Sullivan, A. M., & Linnansaari, T. (2021) · Transactions of the American Fisheries Society · doi:10.1002/tafs.10318 · Cited by 11
Sigmundsson, T. S., Öhman, T., Hallbäck, M., Suárez-Sipmann, F., Wallin, M., Oldner, A., Hällsjö-Sander, C., & Björne, H. (2021) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001566 · Cited by 11
Baumann, C., Almarzooqi, A., Blobner, K., Zapp, D., Kirchmair, K., Schwer, L. S., Lohmann, C. P., & Kaye, S. B. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10132899 · Cited by 11
A Novel Application of Flexible Inertial Sensors for Ambulatory Measurement of Gait Kinematics
Yin, W., Reddy, C. P., Zhou, Y. M., & Zhang, X. (2021) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2021.3086017 · Cited by 13
Slaidina, A., Nikitina, E., Ābeltiņš, A., Soboļeva, U., & Lejnieks, A. (2021) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2021.06.014 · Cited by 12
Piantino, J. A., Luther, M. N., Reynolds, C., & Lim, M. M. (2021) · Nature and Science of Sleep · doi:10.2147/nss.s306317 · Cited by 14
Guillou, R. L., Schmoll, M., Sijobert, B., Borges, D. L., Fachin‐Martins, E., Martins, H. R., Pissard-Gibollet, R., Fattal, C., & Coste, C. (2021) · Sensors · doi:10.3390/s21134571 · Cited by 11
Xu, S., Zhang, J., Zhang, Y., Zhang, P., & Cheng, G. (2021) · Translational Pediatrics · doi:10.21037/tp-21-20 · Cited by 12
Cardiac Output Assessments in Anesthetized Children: Dynamic Capnography Versus Esophageal Doppler
Karlsson, J., Svedmyr, A., Wiegele, M., Lönnqvist, P.-A., Wallin, M., & Hallbäck, M. (2021) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000005679 · Cited by 11
Jones, L., Li, C., Weitzenkamp, D. A., Steeves, J. D., Charlifue, S., & Whiteneck, G. G. (2021) · Neurorehabilitation and neural repair · doi:10.1177/15459683211033854 · Cited by 11
Ma, Y., de Groot, S., Weijs, P. J. M., Achterberg, W. P., Adriaansen, J. J. E., & Janssen, T. W. J. (2021) · Spinal Cord · doi:10.1038/s41393-021-00682-w · Cited by 11
Flegal, K. M., Graubard, B. I., & Ioannidis, J. P. A. (2021) · Obesity · doi:10.1002/oby.23239 · Cited by 11
Honnef, G., Auinger, D., Eichinger, M., Eichlseder, M., Metnitz, P., Rief, M., Zajic, P., Zoidl, P., & Bornemann-Cimenti, H. (2022) · Scientific Reports · doi:10.1038/s41598-022-13285-z · Cited by 11
Step Monitor Accuracy during Poststroke Physical Therapy and Simulated Activities
Henderson, C. E., Toth, L. P., Kaplan, A. S., & Hornby, T. G. (2021) · Translational Journal of the American College of Sports Medicine · doi:10.1249/tjx.0000000000000186 · Cited by 11
T2 quantification in brain using 3D fast spin‐echo imaging with long echo trains
Snyder, J., McPhee, K. C., & Wilman, A. H. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29113 · Cited by 11
Ning, R., Gao, R., Pinero, D. P., Zhang, J., Gao, Q., Jin, Y., Wang, Y., Wang, C., & Huang, J. (2022) · Eye and Vision · doi:10.1186/s40662-021-00274-y · Cited by 11
Maté‐Muñoz, J. L., Garnacho‐Castaño, M. V., Hernández-Lougedo, J., Maicas-Pérez, L., Notario-Alonso, R., Silva‐Grigoletto, M. E. D., García-Fernández, P., & Elvar, J. R. H. (2022) · Biology · doi:10.3390/biology11020336 · Cited by 11
de Faria, L. C., Marques, D. B., Gomes, L. H. D. S. C., dos Anjos, S., & Pereira, N. D. (2022) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2022.2043966 · Cited by 12
Rosiak, O., Gawrońska, A., Janc, M., Marciniak, P., Kotas, R., Zamysłowska-Szmytke, E., & Józefowicz-Korczyńska, M. (2022) · Sensors · doi:10.3390/s22062208 · Cited by 12
Genetic Susceptibility to Enteric Fever in Experimentally Challenged Human Volunteers
Barton, A., Hill, J. W., Bibi, S., Chen, L., Jones, C., Jones, E. A., Camara, S., Shrestha, S., Jin, C., Gibani, M. M., et al. (2022) · Infection and Immunity · doi:10.1128/iai.00389-21 · Cited by 12
Chalkiadaki, E., Gartaganis, P. S., Ntravalias, T., Giannakis, I., Manousakis, E., & Karmiris, E. (2022) · Therapeutic Advances in Ophthalmology · doi:10.1177/25158414211063283 · Cited by 11
Huber, S. K., Knols, R. H., Held, J. P. O., Christen, T., & de Bruin, E. D. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.857963 · Cited by 12
Håberg, Ø., Bremnes, T., Foss, O. A., Angenete, O., Lian, Ø. B., & Holen, K. J. (2022) · Journal of Children s Orthopaedics · doi:10.1177/18632521221106376 · Cited by 11
Thrussell, I., Winfield, J. M., Orton, M. R., Miah, A. B., Zaidi, S., Arthur, A., Thway, K., Strauß, D., Collins, D. J., Koh, D., et al. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.899180 · Cited by 12
Yoo, S., Kim, G., Kim, S., Ha, J., Cho, B. S., Joo, D. J., & Lee, J. I. (2022) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000001033 · Cited by 11
Widmer, J., Descloux, L., Brügger, C., Jäger, M.-L., Berger, T. F. H., & Egger, L. (2022) · Journal of Dairy Science · doi:10.3168/jds.2022-22038 · Cited by 11
Popiołek-Kalisz, J., & Fornal, E. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph191912546 · Cited by 11
Perchiazzi, G., Rylander, C. C., Pellegrini, M., Larsson, A., & Hedenstierna, G. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1631-0 · Cited by 11
TEWL, Closed-Chamber Methods: AquaFlux and VapoMeter
Imhof, B., Xiao, P., & Angelova‐Fischer, I. (2013) · Springer eBooks · doi:10.1007/978-3-642-32109-2_31 · Cited by 13
Étude de validation de l’échelle BDI/TDI dans la bronchopneumopathie chronique obstructive
Laurendeau, C., Pribil, C., Perez, T., Roche, N., Siméoni, M.-C., & Detournay, B. (2009) · Revue des Maladies Respiratoires · doi:10.1016/s0761-8425(09)72424-6 · Cited by 16
Ruminant feces used as inoculum for the in vitro gas production technique
Posada, S. L., Noguera, R. R., & Segura, J. A. (2012) · Revista Colombiana de Ciencias Pecuarias · doi:10.17533/udea.rccp.324801 · Cited by 18
Cerebrospinal fluid volume measurements in hydrocephalic rats: Laboratory investigation
Basati, S., Desai, B. D., Alaraj, A. M., Charbel, F. T., & Linninger, A. A. (2012) · Journal of Neurosurgery Pediatrics · doi:10.3171/2012.6.peds11457 · Cited by 12
Quantification of Intramyocardial Metabolites by Proton Magnetic Resonance Spectroscopy
Gillinder, L., Goo, S. Y., Cowin, G., Strudwick, M. W., van der Geest, R. J., Wang, W. Y. S., & Ng, A. C. T. (2015) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2015.00024 · Cited by 11
Reliability of a Measure of Prediagnosis Physical Activity for Cancer Survivors
Lynch, B. M., Owen, N. G., Newman, B. M., Pakenham, K. I., Leggett, B., Dunn, J. C., & Aitken, J. F. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000210196.94952.8b · Cited by 11
Haggerty, C. M., Kramer, S. P., Škrinjar, O. M., Friday, C. M., Powell, D. K., Mattingly, A. C., Epstein, F. H., & Fornwalt, B. K. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24350 · Cited by 12
Perioperative optimization of oxygen delivery
Conte, B., L'Hermite, J., Ripart, J., & Lefrant, J. (2010) · Transfusion Alternatives in Transfusion Medicine · doi:10.1111/j.1778-428x.2010.01134.x · Cited by 11
Fuku, N., Mori, S., Murakami, H., Gando, Y., Zhou, H., Ito, H., Tanaka, M., & Miyachi, M. (2011) · Geriatrics and gerontology international/Geriatrics & gerontology international · doi:10.1111/j.1447-0594.2011.00768.x · Cited by 13
Reproducibility of liver iron concentration measured on a biopsy sample: A validation study in vivo
Urru, S. A. M., Tandurella, I., Capasso, M., Usala, E., BARONCIANI, D., Giardini, C., Visani, G., & Angelucci, E. (2014) · American Journal of Hematology · doi:10.1002/ajh.23878 · Cited by 11
Boden, L. (2011) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.2011.00414.x · Cited by 13
Jáuregui‐Renaud, K., Villanueva, P. L., & del Castillo, M. S. (2005) · Journal of Vestibular Research · doi:10.3233/ves-2005-15105 · Cited by 11
Hughes, M. J., Harrison, E. M., & Wigmore, S. J. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115601969 · Cited by 11
Teillac, P., Rozet, F., Terrier, N., Mongiat-Artus, P., & Rambeaud, J. (2004) · PubMed · Cited by 11
Bidhult, S. L., Xanthis, C. G., Liljekvist, L. L., Greil, G. F., Nagel, E. C., Aletras, A. H., Heiberg, E., & Hedström, E. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25767 · Cited by 11
Riber‐Hansen, R., Nyengaard, J. R., Hamilton-Dutoit, S. J., Sjoegren, P., & Steiniche, T. (2011) · Histopathology · doi:10.1111/j.1365-2559.2011.03960.x · Cited by 11
Kuhlen, R., Mohnhaupt, R., Slama, K.-J., Hausmann, S., Pappert, D., Rossaint, R., & Falke, K. J. (1996) · Technology and Health Care · doi:10.3233/thc-1996-4406 · Cited by 11
Accuracy of tidal breathing measurement of floright compared to an ultrasonic flowmeter in infants
Petrus, N. C. M., Thamrin, C., Fuchs, O., & Frey, U. (2014) · Pediatric Pulmonology · doi:10.1002/ppul.23006 · Cited by 11
Proud, D. M., Riker, D. K., & Togias, A. G. (2010) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.2010.03466.x · Cited by 11
CD4 and CD8 enumeration for HIV monitoring in resource‐constrained settings
Li, X., Breukers, C., Ymeti, A., Lunter, B., Terstappen, L. W. M. M., & Greve, J. (2008) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.20445 · Cited by 11
McKinon, W., Hartford, C. G., Zio, L. D., van Schalkwyk, J., Veliotes, D. G. A., Hofmeyr, A., & Rogers, G. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/6/001 · Cited by 11
Evaluating estimation techniques in medical imaging without a gold standard: experimental validation
Hoppin, J. W., Kupinski, M. A., Wilson, D. W., Peterson, T. E., Gershman, B., Kastis, G. A., Clarkson, E. W., Furenlid, L. R., & Barrett, H. H. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.480330 · Cited by 11
Accuracy of orchidometry in boys with varicocele
Kurtz, M. P., Migliozzi, M. T., Rosoklija, I., Zurakowski, D., & Diamond, D. A. (2015) · Journal of Pediatric Urology · doi:10.1016/j.jpurol.2015.02.011 · Cited by 11
Meyer, A., Charles, A., Zoll, J., Guillot, M., Lejay, A., Singh, F., Schlagowski, A.-I., Isner-Horobeti, M.-È., Pistea, C., Charloux, A., et al. (2014) · Biochimie · doi:10.1016/j.biochi.2014.01.014 · Cited by 14
Test-retest reliability of the Saladin card
Corbett, A., & Maples, W. C. (2004) · Optometry · doi:10.1016/s1529-1839(04)70210-9 · Cited by 15
Burggraaf, J., Kemme, M. J. B., Muller, L. M., Schoemaker, R. C., & Cohen, A. F. (2000) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2000.00307.x · Cited by 11
Hrynchak, P. K., Hutchings, N., JONES, D. A., & SIMPSON, T. L. (2003) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2003.00088.x · Cited by 11
The Cranial Rhythmic Impulse and Excessive Crying of Infancy
Kotzampaltiris, P. V., Chou, K., Wall, S. P., & Crain, E. F. (2009) · The Journal of Alternative and Complementary Medicine · doi:10.1089/acm.2008.0579 · Cited by 11
Schamberger, M. S., Farrell, A. G., Darragh, R. K., Cordes, T. M., & Ensing, G. J. (2001) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2001.116351 · Cited by 11
Katome, T., Mitamura, Y., Nagasawa, T., Eguchi, H., & Naito, T. (2012) · Retina · doi:10.1097/iae.0b013e3182497141 · Cited by 11
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.