STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 28,701–28,800 of 47,868
Reliability and validity of a new measurement of lumbar foraminal volume using a computed tomography
Khiami, F., Aziria, S.-A., Ragot, S., Pascal‐Moussellard, H., Richer, J.-P., Scépi, M., Brèque, C., & Hirsch, C. (2014) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-014-1324-4 · Cited by 11
Schmitz, S. A., Platzek, I., Kunz, D., Mahlberg, R., Wolf, K.-J., & Heidenreich, J. (2006) · Acta Radiologica · doi:10.1080/02841850600827585 · Cited by 11
Influence of Paper Electrocardiogram Digitizing on T Wave and QRS Complex Morphology Parameters
Karsikas, M., Huikuri, H. V., Perkiömäki, J. S., Lehtola, L., & Seppänen, T. (2007) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2007.00176.x · Cited by 11
GAGNON, D. R., McLean, R. R., Hannan, M. T., Cupples, L. A., Hogan, M., & Kiel, D. P. (2010) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2010.01.003 · Cited by 11
Hirano, K., Naito, T., Mino, Y., Takayama, T., Ozono, S., & Kawakami, J. (2012) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.07.018 · Cited by 11
Gorman, P. H., Geigle, P. R., Chen, K., York, H. S., & Scott, W. H. (2014) · Spinal Cord · doi:10.1038/sc.2014.6 · Cited by 11
Heiene, R., Eliassen, K. A., Risøen, U., Neal, L. A., & Cowgill, L. D. (2010) · American Journal of Veterinary Research · doi:10.2460/ajvr.71.9.1100 · Cited by 11
Relevance of a portable spirometer for detection of small airways obstruction
Ezzahir, N., Leske, V., Peiffer, C., & Trang, H. (2004) · Pediatric Pulmonology · doi:10.1002/ppul.20148 · Cited by 11
Brighton, C., Olsen, E., & Pfau, T. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.819857 · Cited by 11
Lang, E., Hilz, M. J., Erxleben, H., Ernst, M., Neundörfer, B., & Liebig, K. (2002) · Spine · doi:10.1097/00007632-200210150-00020 · Cited by 11
Scotopic measurement of normal pupil size with the Colvard pupillometer and the Nidek auto-refractor
Mantry, S., Banerjee, S., Naroo, S. A., & Shah, S. (2005) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2004.12.002 · Cited by 11
Monitoring local trends in Indigenous tobacco consumption
Thomas, D., Johnston, V., Fitz, J., & McDonnell, J. (2009) · Australian and New Zealand Journal of Public Health · doi:10.1111/j.1753-6405.2009.00340.x · Cited by 11
Standardized standing pelvis-to-floor photographs for the assessment of lower-extremity alignment
Sheehy, L., Cooke, T. D. V., McLean, L., & Culham, E. G. (2014) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2014.12.009 · Cited by 11
Williamson, J., McLaughlin, R. A., Phillips, M. J., Curatolo, A., Armstrong, J. J., Maddison, K. J., Sheehan, R. E., Sampson, D. D., Hillman, D. R., & Eastwood, P. R. (2010) · Journal of Bronchology & Interventional Pulmonology · doi:10.1097/lbr.0b013e3181f9eaae · Cited by 11
Marjanovic, I. S., Milic, N. M., & Martinez, A. (2011) · European Journal of Ophthalmology · doi:10.5301/ejo.2011.8311 · Cited by 11
Liao, J. J. Z. (2005) · Journal of Biopharmaceutical Statistics · doi:10.1081/bip-200048810 · Cited by 11
An Accurate Method to Determine Bowman's Layer Thickness In Vivo in the Human Cornea
Germundsson, J., Fagerholm, P., Koulikovska, M., & Lagali, N. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-8565 · Cited by 11
Simultaneous Urography and Determination of Glomerular Filtration Rate
Lundqvist, S., Hietala, S.-O., Berglund, C., & Karp, K. H. (1994) · Acta Radiologica · doi:10.1177/028418519403500415 · Cited by 11
Intraosseous monitoring and guiding by ultrasound: A feasibility study
Rosenberg, N., Craft, A., & Halevy-Politch, J. (2013) · Ultrasonics · doi:10.1016/j.ultras.2013.09.008 · Cited by 11
Is BRIEF a useful instrument in day to day care of patients with phenylketonuria?
Liemburg, G. B., Jahja, R., van Spronsen, F. J., de Sonneville, L. M. J., van der Meere, J. J., Bosch, A. M., Hollak, C. E. M., Rubio‐Gozalbo, M. E., Brouwers, M. C. G. J., Hofstede, F. C., et al. (2014) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2014.12.302 · Cited by 13
González-Cánovas, C., Muñoz‐Esparza, C., Oliva, M. J., González‐Carrillo, J., López‐Cuenca, Á., Saura, D., García‐Navarro, M., Espinosa, M. D., Caro, C., Caballero, L., et al. (2012) · Revista Española de Cardiología · doi:10.1016/j.recesp.2012.08.010 · Cited by 13
Pepler, A., Munro, K. J., Lewis, K., & Kluk, K. (2014) · International Journal of Audiology · doi:10.3109/14992027.2014.917207 · Cited by 11
Lee, X., Kumazawa, T., Hasegawa, C., Arinobu, T., Seno, H., Suzuki, O., & Sato, K. (2012) · Forensic Toxicology · doi:10.1007/s11419-012-0155-4 · Cited by 11
Halvorsen, T., Skadberg, B. T., Eide, G. E., Røksund, O. D., Bakke, P. S., & Thorsen, E. (2005) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2004.00591.x · Cited by 11
Yapo, V., Toni, T. D., Desmonde, S., Amani‐Bosse, C., Oga, M., Lenaud, S., Menan, H. I. E., Timité‐Konan, M., Leroy, V., & Rouzioux, C. (2013) · Journal of Virological Methods · doi:10.1016/j.jviromet.2013.07.011 · Cited by 11
Scisney‐Matlock, M., Grand, A., Steigerwalt, S. P., & Normolle, D. P. (2009) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283263064 · Cited by 12
Assessment of airway closure from deflation lung volume–pressure curve: sigmoidal equation revisited
Bayle, F., Guérin, C., Debord, S., Badet, M., Lemasson, S., Poupelin, J.-C., & Richard, J. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0160-3 · Cited by 12
Stjepanović, D., Lorenzetti, V., Yücel, M., Hawi, Z., & Bellgrove, M. A. (2013) · Translational Psychiatry · doi:10.1038/tp.2013.41 · Cited by 15
Teixeira, R. P., Monteiro, R., Baptista, R., Barbosa, A., Leite, L., Ribeiro, M. A., Martins, R., Cardim, N. M., & Gonçalves, L. M. M. (2015) · International journal of cardiac imaging · doi:10.1007/s10554-015-0597-y · Cited by 14
Reproducibility of diabetes quality of care indicators as reported by patients and physicians
Collet, T., Taffé, P., Bordet, J., Burnand, B., & Peytremann‐Bridevaux, I. (2014) · European Journal of Public Health · doi:10.1093/eurpub/cku011 · Cited by 12
Memory processes in the development of reduced-salt foods
Herbert, V., Bertenshaw, E. J., Zandstra, E. H., & Brunstrom, J. M. (2014) · Appetite · doi:10.1016/j.appet.2014.08.019 · Cited by 12
Hannon, J. C., Ratliffe, T., & Williams, D. P. (2006) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2006.10599387 · Cited by 11
Villalba, R., Jiménez, A., Fornés, G., Eisman, M., & Villagrán, J. L. G. (2014) · Cell and Tissue Banking · doi:10.1007/s10561-014-9434-0 · Cited by 11
Malter, S., Hirsch, C., Reissmann, D. R., Schierz, O., & Bekes, K. (2015) · Clinical Oral Investigations · doi:10.1007/s00784-015-1434-3 · Cited by 11
The Development and Validation of an Outcome Measure for Spiritual Healing: A Mixed Methods Study
Bishop, F. L., Barlow, F., Walker, J., McDermott, C., & Lewith, G. T. (2010) · Psychotherapy and Psychosomatics · doi:10.1159/000320120 · Cited by 11
The FloTrac™ System—Measurement of Stroke Volume and the Assessment of Dynamic Fluid Loading
Hashim, B., & Lerner, A. B. (2009) · International Anesthesiology Clinics · doi:10.1097/aia.0b013e3181b48a1b · Cited by 11
Clinical evaluation of a high-fidelity wireless intravaginal pressure sensor
Arora, A. S., Kruger, J., Budgett, D., Hayward, L. M., Smalldridge, J., Nielsen, P. F., & Kirton, R. S. (2014) · International Urogynecology Journal · doi:10.1007/s00192-014-2500-0 · Cited by 11
Fong, K. W., Dengler, J., Toi, A., Menezes, R. J., Karimzad, Y., & Okun, N. B. (2014) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.33.8.1373 · Cited by 12
INTRA-ABDOMINAL PRESSURE MEASUREMENTS IN LATERAL DECUBITUS VERSUS SUPINE POSITION
Keulenaer, B. L. D., Cheatham, M. L., Waele, J. J. D., Kimball, E. J., Powell, B., Davis, W. A., & Jenkins, I. R. (2009) · Acta Clinica Belgica · doi:10.1179/acb.2009.037 · Cited by 11
Vogt, K., Rasmussen, J. G., Skovgaard, L. T., Just, S. R. L., & Schroeder, T. V. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00068-4 · Cited by 11
Nambi, P. V., Sengupta, R., Krajcer, Z., Muthupillai, R., Strickman, N., & Cheong, B. (2011) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2010.11.027 · Cited by 11
Improving Quantitative CT Perfusion Parameter Measurements Using Principal Component Analysis
Yeung, T. P. C., Dekaban, M., Haan, N. D., Morrison, L. B., Hoffman, L., Bureau, Y., Chen, X., Yartsev, S., Bauman, G. S., & Lee, T.-Y. (2014) · Academic Radiology · doi:10.1016/j.acra.2014.01.015 · Cited by 12
Evaluation of Noninvasive Follow-up Methods for the Detection of Intracranial In-Stent Restenosis
Psychogios, M., Schramm, P., Amelung, N., Pilgram-Pastor, S. M., Gröschel, K., Wasser, K., Frölich, A. M., Mohr, A., & Knauth, M. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e318276db43 · Cited by 11
Lee, C. M., Gorelick, M., & Mendoza, A. (2011) · Journal of Sports Sciences · doi:10.1080/02640414.2011.609899 · Cited by 11
Colquhoun, D. A., Forkin, K. T., Dunn, L. K., Bogdonoff, D. L., Durieux, M. E., & Thiele, R. H. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.774443 · Cited by 11
García‐Donaire, J. A., Baqué, A. D., Anso, C. S., Castillo, D. U., Debén, F. M., López, N. O., Núñez, J. L. P., Martín-Oterino, J.-Á., Herreros, J. G.-N., García, J. D. M., et al. (2012) · Medicina Clínica · doi:10.1016/j.medcli.2011.10.030 · Cited by 13
Hüter, L., Schwarzkopf, K. R. G., Preussler, N.-P., Schubert, H., & Schreiber, T. (2007) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2007.01.005 · Cited by 11
Benders, M. J. N. L., Hendrikse, J., de Vries, L. S., Groenendaal, F., & van Bel, F. (2012) · Neonatology · doi:10.1159/000342336 · Cited by 11
Giorgetti, A., Kusch, A., Casagranda, M., D’Aragona, I., & Marzullo, P. (2009) · Journal of Nuclear Cardiology · doi:10.1007/s12350-009-9172-z · Cited by 11
Pręgowski, J., Kępka, C., Kalińczuk, Ł., Kruk, M. B. P., Mintz, G. S., Ciszewski, A., Chmielak, Z., Ciszewski, M., Wolny, R., Szubielski, M., et al. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.01.018 · Cited by 11
Is Measurement Error Altered by Participation in a Physical Activity Intervention?
WINKLER, E. A. H., Waters, L., Eakin, E., Fjeldsoe, B. S., Owen, N. G., & Reeves, M. M. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827ccf7d · Cited by 11
Affret, A., Griz, L., Cesse, E. Â. P., Specht, Y. D. S., de Carvalho, E. M. F., & Fontbonne, A. (2015) · Sao Paulo Medical Journal · doi:10.1590/1516-3180.2013.9110911 · Cited by 14
The Development of a Self-Reported Version of the Chronic Heart Questionnaire
Evans, R. A., Singh, S., Williams, J. E., & Morgan, M. D. L. (2011) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0b013e318228a31a · Cited by 13
Malik, R., Swanson, W. H., & Garway‐Heath, D. F. (2006) · Vision Research · doi:10.1016/j.visres.2006.03.004 · Cited by 11
Finkelhor, R. S., Scrocco, J. D., Madmani, M. E., Rovner, A., & Pillai, D. P. (2013) · Echocardiography · doi:10.1111/echo.12361 · Cited by 11
How accurate is CT morphometry of airway? Phantom and clinical validation study
Takahashi, M., Okada, H., Oguni, N., Maeda, K., Segawa, K., Nitta, N., & Murata, K. (2011) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.12.035 · Cited by 13
Day-to-day repeatability of the Pulse Time Index of Norm
Posokhov, I. N., Конради, А. О., Shlyakhto, E. V., Mamontov, O. V., Orlov, A. V., & Рогоза, А. Н. (2014) · Medical Devices Evidence and Research · doi:10.2147/mder.s58507 · Cited by 12
Measuring intermittent exercise performance using shuttle running
Ali, A., Foskett, A., & Gant, N. (2013) · Journal of Sports Sciences · doi:10.1080/02640414.2013.847276 · Cited by 16
Continuous Cardiac Output Monitoring: What Do Validation Studies Tell Us?
Critchley, L. A. H., Huang, L., & Zhang, J. (2014) · Current anesthesiology reports · doi:10.1007/s40140-014-0062-9 · Cited by 11
Profile and course of early rheumatoid arthritis in Morocco: a two-year follow-up study
Benbouazza, K., Benchekroun, B., Rkain, H., Amine, B., Bzami, F., Benbrahim, L., Atouf, O., Essakalli, M., Abouqal, R., Dougados, M., et al. (2011) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-12-266 · Cited by 11
Original characteristics of a new cycle ergometer
Bertucci, W., Grappe, F., & Créquy, S. (2011) · Sports Engineering · doi:10.1007/s12283-011-0063-6 · Cited by 11
Parental reported compared with measured waist circumference in 8-year-old children
Bekkers, M. B. M., Brunekreef, B., Scholtens, S., Kerkhof, M., Smit, H. A., & Wijga, A. H. (2010) · International Journal of Pediatric Obesity · doi:10.3109/17477166.2010.490266 · Cited by 12
Larici, A. R., Calandriello, L., Amato, M., Silvestri, R., del Ciello, A., Molinari, F., de Waure, C., Vita, M. L., Carnassale, G., & Bonomo, L. (2013) · La radiologia medica · doi:10.1007/s11547-013-0300-0 · Cited by 11
Almeida, M. D. L. C., Suárez-Serrano, C., Jiménez‐Rejano, J., Díaz, J. R., Benítez-Lugo, M.-L., & Roldán, J. R. (2014) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.12534 · Cited by 13
Rahman, M. Y. A. E., Rentzsch, A., Scherber, P. R., Mebus, S., Miera, O., Balling, G., Boettler, P., Dubowy, K., Farahwaschy, B., Hager, A., et al. (2014) · Clinical Research in Cardiology · doi:10.1007/s00392-014-0703-5 · Cited by 11
Apparatus for measuring rat body volume: a methodological proposition
Hohl, R., de Oliveira, R. B., de Macedo, D. V., & Brenzikofer, R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00744.2006 · Cited by 11
Carbonate as sputter target material for rapid 14C AMS
Longworth, B. E., Robinson, L. F., Roberts, M. L., Beaupré, S. R., Burke, A., & Jenkins, W. J. (2012) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2012.05.014 · Cited by 14
Algorithm for particle detection and parameterization in high-frame-rate thermal video
Bombrun, M., Barra, V., & Harris, A. J. L. (2014) · Journal of Applied Remote Sensing · doi:10.1117/1.jrs.8.083549 · Cited by 11
Albu, G., Peták, F., Zand, T., Hallbäck, M., Wallin, M. K. E. B., & Habre, W. (2014) · BMC Anesthesiology · doi:10.1186/1471-2253-14-64 · Cited by 11
Ng, W.-Y., Tiong, C. C., & Jacob, E. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0095 · Cited by 12
Hansen, J. M., Fahrenkrug, J., Petersen, J., Wienecke, T., Olsen, K. S., & Ashina, M. (2013) · Scandinavian Journal of Pain · doi:10.1016/j.sjpain.2013.04.002 · Cited by 11
Pulse oximeter-enhanced accuracy of capnometry in children with cyanotic heart disease
de Vries, J. W., Plötz, F. B., & van Vught, J. A. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1409-0 · Cited by 11
Use of Morphometry to Quantify Osteolysis after Total Hip Arthroplasty
Smith, L. K., Cramp, F. L., Palmer, S., Coghill, N. F., & Spencer, R. F. (2010) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-010-1377-6 · Cited by 11
Development of a Walking Aerobic Capacity Test for Structural Firefighters
Moore, K. J., Penry, J. T., & Gunter, K. B. (2014) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000433 · Cited by 12
Fernandes, A. D. A., da Silva, C. D., Vieira, B. C., & Marins, J. C. B. (2012) · Fisioterapia e Pesquisa · doi:10.1590/s1809-29502012000400010 · Cited by 11
Kaur, P., Khong, W. X., Wee, S. Y., Tan, E. L., Pipper, J., Koay, E. S. C., Ng, K. Y., Yap, J. K., Chew, K. K., Tan, M. T., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0089826 · Cited by 11
MacIntyre, N. J., Stavness, C., & Adachi, J. D. (2009) · Clinical Rheumatology · doi:10.1007/s10067-009-1297-6 · Cited by 14
Matthews, F., Largiadèr, T., Rhomberg, P., van der Loo, B., Schmid, E. R., & Jenni, R. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep233 · Cited by 11
Automated Versus Manual Platelet Count in Aden
Bakhubaira, S. (2013) · Journal of Clinical & Experimental Pathology · doi:10.4172/2161-0681.1000149 · Cited by 11
van Ittersum, M. W., Bieleman, A., Reneman, M. F., Oosterveld, F. G. J., Groothoff, J. W., & van der Schans, C. P. (2009) · Journal of Occupational Rehabilitation · doi:10.1007/s10926-009-9179-y · Cited by 11
Green, M. D., Mayxay, M., Beach, R. F., Pongvongsa, T., Phompida, S., Hongvanthong, B., Vanisaveth, V., Newton, P. N., Vizcaino, L., & Swamidoss, I. (2013) · Malaria Journal · doi:10.1186/1475-2875-12-57 · Cited by 11
Salm, L. P., Langerak, S. E., Vliegen, H. W., Jukema, J. W., Bax, J. J., Zwinderman, A. H., van der Wall, E. E., Roos, A., & Lamb, H. J. (2004) · Radiology · doi:10.1148/radiol.2323030289 · Cited by 11
Díaz, J. R., Ferrando, A. D. G., Payá, J. J. M., & Aledo, M. E. D. B. (2010) · Reumatología Clínica (English Edition) · doi:10.1016/s2173-5743(10)70066-6 · Cited by 11
Ardiet, D.-L., Graz, B., Szeless, T., Mauris, A., Falquet, J., Doumbo, O. K., Dolo, A., Guindo, O., Sissoko, M. S., Konaré, M., et al. (2014) · Malaria Journal · doi:10.1186/1475-2875-13-199 · Cited by 14
Fully automated computer-aided volume estimation system for thyroid planar scintigraphy
Huang, J.-Y., Lin, K., & Chen, Y. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.07.006 · Cited by 11
Chozas, J. M. V., Sáez-Benito, A., García, N. Z., Pinteño, S. G., Joumady, I., García, C. C., & Gil, F. V. (2012) · Transplantation Proceedings · doi:10.1016/j.transproceed.2012.09.063 · Cited by 11
Liu, J., Yuan, L., Zhang, Z., Duan, Y.-Y., Xue, J., Yang, Y., Guo, Q., & Cao, T. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00863.2010 · Cited by 11
Reichert, F. F., Menezes, A. M. B., Araújo, C. L., & Hallal, P. C. (2010) · Cadernos de Saúde Pública · doi:10.1590/s0102-311x2010001000008 · Cited by 14
Mesh-based method for measuring intracranial volume in patients with craniosynostosis
Ritvanen, A. G., de Oliveira, M. E., Koivikko, M. P., Hallila, H., Haaja, J., Koljonen, V., Leikola, J. P., Hukki, J., & Paulasto‐Kröckel, M. (2013) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-013-0822-x · Cited by 12
Endothelial Dysfunction in the Smokers Can Be Improved with Oral Cilostazol Treatment
Kim, K. S., Park, H. S., Jung, I. S., Park, J., Ahn, K. T., Jin, S., Park, Y. K., Kim, J. H., Lee, J., Choi, S. W., et al. (2011) · Journal of Cardiovascular Ultrasound · doi:10.4250/jcu.2011.19.1.21 · Cited by 12
MRI analysis of the size and shape of the oropharynx in chronic whiplash
Elliott, J. M., Cannata, E., Christensen, E., DeMaris, J., Kummrow, J., Manning, E., Nielsen, E., Romero, T., Barnes, C., & Jull, G. A. (2008) · Otolaryngology · doi:10.1016/j.otohns.2008.02.015 · Cited by 11
Noninvasive cardiac output measurement using bioreactance in postoperative pediatric patients
Vergnaud, E., Vidal, C., Montmayeur, J., Taright, H., Meyer, P. G., Carli, P. A., & ORLIAGUET, G. A. (2014) · Pediatric Anesthesia · doi:10.1111/pan.12412 · Cited by 11
Construction and pilot assessment of the Upper Limb Assessment in Daily Living Scale
Rousseaux, M., Bonnin-Koang, H.-Y., Darné, B. M., Marque, P., Parratte, B., Schnitzler, A., Dehail, P., Bradai, N., Viton, J. M., Daveluy, W., et al. (2012) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp-2011-300929 · Cited by 13
Prediction of Arterial Oxygen Tension: Validation of a Novel Formula
Hardman, J. G., & Al-Otaibi, H. M. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.182.3.435 · Cited by 11
Cunha, K. S., Rozza‐de‐Menezes, R. E., Andrade, R. M., Theos, A. J., Luiz, R. R., Korf, B. R., & Geller, M. (2014) · Orphanet Journal of Rare Diseases · doi:10.1186/s13023-014-0202-9 · Cited by 11
A Unified Approach for Nonparametric Evaluation of Agreement in Method Comparison Studies
Choudhary, P. K. (2010) · The International Journal of Biostatistics · doi:10.2202/1557-4679.1235 · Cited by 11
Agreement between fingertip-capillary and antecubital-venous appetite-related peptides
Green, B. P., Gonzalez, J. T., Thomas, K., Stevenson, E., & Rumbold, P. L. S. (2014) · Endocrine Connections · doi:10.1530/ec-14-0110 · Cited by 12
Lack of agreement between gas exchange variables measured by two metabolic systems.
Jakovljević, D. G., Nunan, D., Donovan, G., Hodges, L. D., Sandercock, G. R. H., & Brodie, D. A. (2008) · Europe PMC (PubMed Central) · doi:10.25405/ncl.34095630 · Cited by 11
Gimmon, Y., Grinshpon, J., Lenoble-Hoskovec, C., Büla, C., & Melzer, I. (2013) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2013.02.001 · Cited by 15
Automated counting for Plasmodium falciparum cytoadherence experiments
Paton, D. G., Faragher, B. E., Mustaffa, K. M. F., Szestak, T., Barrett, S. D., & Craig, A. G. (2011) · Malaria Journal · doi:10.1186/1475-2875-10-91 · Cited by 11
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.