STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 33,101–33,200 of 47,868
Xu, B., Vu, C. Q., Borzage, M., González-Zacarías, C., Shen, J. Y., & Wood, J. C. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120448 · Cited by 7
Kapan, A., Ristić, M., Yang, L., Kranz, G., & Waldhör, T. (2023) · Healthcare · doi:10.3390/healthcare11233020 · Cited by 8
Fendrik, K., Biró, K., Endrei, D., Koltai, K., Sándor, B., Tóth, K., & Késmárky, G. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1275856 · Cited by 7
Rethy, B., Nordenvall, C. A. M., Pieniowski, E. H. A., Palmer, G., Johar, A. M., Lagergren, P., & Abraham‐Nordling, M. (2024) · BMJ Open Gastroenterology · doi:10.1136/bmjgast-2023-001274 · Cited by 8
Alsit, A., Hamdan, H., Tahhan, A. B. A., Mughieda, O., Mourad, A. I., Shehadeh, M. A., & AlKhedher, M. A. (2024) · Results in Engineering · doi:10.1016/j.rineng.2024.101833 · Cited by 7
Plourde, G., Carrier, F. M., Bijlenga, P., & Quintard, H. (2024) · Neurocritical Care · doi:10.1007/s12028-024-01949-9 · Cited by 7
Ishigaki, T., Kubo, H., Yoshida, K., Shimizu, N., & Ogawa, T. (2024) · Frontiers in Rehabilitation Sciences · doi:10.3389/fresc.2024.1384369 · Cited by 9
Jung, J. W., Chung, B., Han, S. H., Kim, E. K., Seo, K. Y., & Kim, T. (2015) · Journal of Refractive Surgery · doi:10.3928/1081597x-20150521-06 · Cited by 7
Evaluation of a Circumference-based Prediction Equation to Assess Body Composition Changes in Men
Schuna, J. M., Hilgers, S., Manikowske, T. L., Tucker, J. M., & Liguori, G. A. (2013) · International journal of exercise science · doi:10.70252/fyyg7160 · Cited by 8
Szulik, M., ŒLiwiñska, A., Lenarczyk, R., Szyma£A, M., Kalinowski, M. E., Markowicz-Pawlus, E., Kalarus, Z. F., & Kukulski, T. (2015) · Acta cardiologica. Supplementum · doi:10.1080/ac.70.1.3064590 · Cited by 7
Dulku, S., Smith, H. B., & Antcliff, R. J. (2012) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2012.02816.x · Cited by 7
Offert, B., Pazera, P., Janiszewska‐Olszowska, J., Hozyasz, K. K., Katsaros, C., & Fudalej, P. S. (2012) · Orthodontics and Craniofacial Research · doi:10.1111/j.1601-6343.2012.01544.x · Cited by 7
Elmlinger, M. W. (2011) · KARGER eBooks · doi:10.1159/000327398 · Cited by 7
Ciarmiello, A., Giovacchini, G., Guidotti, C., Meniconi, M., Lazzeri, P., Carabelli, E., Mansi, L., Mariani, G., Volterrani, D., & del Sette, M. (2013) · Journal of Cellular Physiology · doi:10.1002/jcp.24378 · Cited by 7
Relationship of PON1 192 and 55 gene polymorphisms to calcific valvular aortic stenosis.
Moura, L. M., Faria, S., Brito, M., Pinto, F. J., Kristensen, S. D., Barros, I. M., Rajamannan, N. M., & Rocha‐Gonçalves, F. (2012) · PubMed · Cited by 7
Zufferey, G., Perneger, T., Robert‐Yap, J., Skała, K., & Roche, B. (2011) · Colorectal Disease · doi:10.1111/j.1463-1318.2011.02645.x · Cited by 7
A general variance model in methods comparison
Hawkins, D. M. (2013) · Journal of Chemometrics · doi:10.1002/cem.2550 · Cited by 7
The Statistical Interpretation of the Coefficient of Repeatability
Loughman, J. (2010) · Arrow - TU Dublin (Technological University Dublin) · Cited by 7
Steeden, J. A., & Muthurangu, V. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24638 · Cited by 7
Validity of first post‐operative day automated refraction following dense cataract extraction
Briesen, S., Ng, E., & Roberts, H. (2011) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2010.00567.x · Cited by 7
Handcrafted cuff manometers do not accurately measure endotracheal tube cuff pressure
Annoni, R., & de Almeida, A. E. (2015) · Revista Brasileira de Terapia Intensiva · doi:10.5935/0103-507x.20150037 · Cited by 7
Djerf, P., Brundin, M., Bajk, M., & Smedh, U. (2015) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365521.2015.1041151 · Cited by 7
Clinimetric properties of breath‐stacking technique for assessment of inspiratory capacity
Feitosa, L. A. D. S., Barbosa, P. A., Pessoa, M. F., Rodrigues‐Machado, M. D. G., & de Andrade, A. D. (2011) · Physiotherapy Research International · doi:10.1002/pri.512 · Cited by 7
Howatson, G., & van Someren, K. A. (2005) · Isokinetics and Exercise Science · doi:10.3233/ies-2005-0186 · Cited by 7
High Order Polynomial Surface Fitting for Measuring Roughness of Psoriasis Lesion
Hani, A. F. M., Prakasa, E., Fitriyah, H., Nugroho, H., Affandi, A. M., & Hussein, S. H. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-25191-7_33 · Cited by 7
Subject-specific compressive tolerance estimates
Davis, K. G., & Parnianpour, M. (2003) · Technology and Health Care · doi:10.3233/thc-2003-11303 · Cited by 7
Pearson, R. M., & Evans, B. J. W. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2012.00932.x · Cited by 7
Papoti, M., Vitório, R., de Araújo, G. G., Martins, L. E. B., Cunha, S. A., & Gobatto, C. A. (2009) · Brazilian Journal of Kinanthropometry and Human Performance · doi:10.5007/1980-0037.2010v12n1p14 · Cited by 7
Hötker, A. M., Schmidtmann, I. M., Oberholzer, K., & Düber, C. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24385 · Cited by 7
Ahluwalia, N., Bulux, J., Solomons, N. W., Romero‐Abal, M., Hernández, M. M., & Boy, E. (2005) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.6.1366 · Cited by 7
Malaysia, U. K., Shahar, S., Lin, C. H., & Haron, H. (2014) · Jurnal Sains Kesihatan Malaysia · doi:10.17576/jskm-2014-1202-05 · Cited by 8
Cha, R., Lee, C. S., Lim, Y.-H., Kim, H., Lee, S. H., Yu, K. S., & Kim, Y. S. (2010) · Nephrology · doi:10.1111/j.1440-1797.2010.01344.x · Cited by 7
Development and validation of a new C hinese reading chart for children
Cheung, J. P. Y., Liu, D. S. K., Lam, C. C.-C., & Cheong, A. M. Y. (2015) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12228 · Cited by 7
Intensivmedizinische Patienten
Rokuss, K., Kalenka, A., Bender, H., & Hinkelbein, J. (2009) · Der Anaesthesist · doi:10.1007/s00101-009-1552-x · Cited by 7
Using simple anthropometric measures to predict body fat in South Asians
Kohli, S., Gao, M., & Lear, S. A. (2009) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h08-128 · Cited by 9
4D Segmentation of Cardiac Data Using Active Surfaces with Spatiotemporal Shape Priors
Abufadel, A., Yezzi, T., & Schafer, R. W. (2008) · Studies in computational intelligence · doi:10.1007/978-3-540-76831-9_4 · Cited by 7
¿Es útil la antropometría para estimar la composición corporal en niños preescolares?
Gabriela Salazar, R., María Auxiliadora Rocha, A., & Mardones, F. (2003) · Revista chilena de pediatría · doi:10.4067/s0370-41062003000100005 · Cited by 7
Madan, N., Yau, J. L., Srivastava, S., & Nielsen, J. C. (2012) · Pediatric Cardiology · doi:10.1007/s00246-012-0480-8 · Cited by 7
HbA1c method evaluation for postmortem samples
Keltanen, T., Sajantila, A., Valonen, T., Partanen, T., & Lindroos, K. (2014) · Forensic Science Medicine and Pathology · doi:10.1007/s12024-014-9638-4 · Cited by 8
Shan, J., Pow, E., Tsang, P. C. S., Perera, R. A. P. M., & Kwong, D. L. W. (2013) · Journal of Investigative and Clinical Dentistry · doi:10.1111/jicd.12078 · Cited by 7
An analysis of blood pressure measurement in a primary care hospital in Swaziland
Mlawanda, G., Pather, M. K., & Govender, S. (2014) · African Journal of Primary Health Care & Family Medicine · doi:10.4102/phcfm.v6i1.590 · Cited by 7
Soares, S. M. T. P., Jannuzzi, H. P. C., Kassab, M. F. O., Nucci, L. B., & Paschoal, M. A. (2014) · Physiotherapy · doi:10.1016/j.physio.2014.11.004 · Cited by 10
Jones, L. (1991) · Clinical Rehabilitation · doi:10.1177/026921559100500301 · Cited by 7
A Nasal Catheter for the Measurement of End-Tidal Carbon Dioxide in Spontaneously Breathing Patients
Raheem, M. S. A., & Wahba, O. M. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181d365fd · Cited by 7
An evaluation of the N-CAT, a new arterial tonometer
Searle, N. R., Gauthier, J. B., & Sahab, P. (1995) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03011693 · Cited by 7
Moreno, V. M., Gandoy, J. B. G., González, M. J. A., & de la Cámara, A. G. (2003) · Revista Española de Salud Pública · doi:10.1590/s1135-57272003000300005 · Cited by 7
EDTA Samples for the Measurement of Erythrocyte Sedimentation Rate Using Sedimatic 100 Analyser
Horsti, J. E. (2001) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2001.163 · Cited by 7
Rose, M., Rubal, B. J., Hulten, E. A., Slim, J. N., Steel, K. E., Furgerson, J. L., Villines, T. C., & Slim, A. M. (2014) · SAGE Open Medicine · doi:10.1177/2050312114522789 · Cited by 7
Left ventricular long-axis function in treated haemochromatosis
Davidsen, E. S., Hervig, T. A., Omvik, P., & Gerdts, E. (2008) · International journal of cardiac imaging · doi:10.1007/s10554-008-9383-4 · Cited by 7
Toulon, P. A., Fischer, F., Appert‐Flory, A., & Jambou, D. (2014) · Thrombosis Research · doi:10.1016/j.thromres.2014.02.021 · Cited by 7
Hjelstuen, M. H. B., Mjaaland, I., Vikström, J., Madebo, T., & Dybvik, K. I. (2014) · Acta Oncologica · doi:10.3109/0284186x.2014.990107 · Cited by 7
Hagman, B. T., Cohn, A. M., & Noel, N. E. (2010) · Addictive Disorders & Their Treatment · doi:10.1097/adt.0b013e3181e5c21e · Cited by 7
A Clinical Evaluation of Proview Pressure Phosphene Tonometry in Children
Chung, I., Bartolone, A. G., Swanson, W. H., & Thau, A. P. (2006) · Optometry and Vision Science · doi:10.1097/01.opx.0000239101.75107.3c · Cited by 7
Michel, O., Doyen, V., Leroy, B., Bopp, B., Dinh, D. H. P., Corazza, F., & Wattiez, R. (2013) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-13-65 · Cited by 8
Hauge, S. J., Nesbakken, T., Skjerve, E., Dommarsnes, K., & Østensvik, Ø. (2010) · International Journal of Food Microbiology · doi:10.1016/j.ijfoodmicro.2010.07.005 · Cited by 7
Cannesson, M. P., Desebbe, O., Piriou, V., & Lehot, J.-J. (2010) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/j.annfar.2010.03.010 · Cited by 7
Armstrong, R. A., & Bradwell, T. (2015) · Quaternary Geochronology · doi:10.1016/j.quageo.2015.04.003 · Cited by 7
Dimensions of the Ascending Aorta in Conotruncal Heart Defects
Trippel, A., Pallivathukal, S., Pfammatter, J., Hutter, D., Kadner, A., & Pavlović, M. (2014) · Pediatric Cardiology · doi:10.1007/s00246-014-0862-1 · Cited by 7
Facial motor function monitored by hand held calipers versus computer-assisted photography
Clapham, L., Bottoms, S., Mehta, R., & Davis, A. (2006) · Acta Neurochirurgica · doi:10.1007/s00701-006-0904-4 · Cited by 7
Lichtner, G., Golebiewski, A. K., Schneider, M., & von Dincklage, F. (2015) · Brain Research · doi:10.1016/j.brainres.2015.02.049 · Cited by 10
de Barros, F. S. B., Bussamra, L. C. S., Júnior, E. A., de Freitas, L. D. S. V., Nardozza, L. M. M., Moron, A. F., & Aldrighi, J. M. (2012) · ISRN Obstetrics and Gynecology · doi:10.5402/2012/286141 · Cited by 7
Hellgren, L., Landelius, J., Stridsberg, M., Kvidal, P., Ståhle, E., & Bjerner, T. (2008) · Scandinavian Cardiovascular Journal · doi:10.1080/14017430701678691 · Cited by 7
Bruce, H. L. (2003) · Meat Science · doi:10.1016/s0309-1740(03)00152-9 · Cited by 7
Reproducibility and accuracy of ABC/2 and 3D techniques in ICH volume measurement
Tsair, T. J., & Aziz, A. (2010) · Radiography · doi:10.1016/j.radi.2010.04.004 · Cited by 7
Swaminathan, M., Phillips‐Bute, B. G., & Mathew, J. P. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000074125.74597.20 · Cited by 7
Oh, S. B., Cho, W. B., Moon, J. W., & Kim, H. C. (2009) · Journal of the Korean Ophthalmological Society · doi:10.3341/jkos.2009.50.5.710 · Cited by 7
Davey, P. G., Lievens, C., Newman, J. M., Gerstner, M. D., Chang, F. W. I., & Haine, C. L. (2007) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2007.00161.x · Cited by 7
Frings, V., de Langen, A. J., Yaqub, M. M., Schuit, R. C., van der Veldt, A. A. M., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2013) · Molecular Imaging and Biology · doi:10.1007/s11307-013-0658-3 · Cited by 7
Comparison of Fick and thermodilution cardiac output determinations in standing horses
Lépiz, M., Keegan, R. D., Bayly, W. M., Greene, S. A., & McEwen, M.-M. (2008) · Research in Veterinary Science · doi:10.1016/j.rvsc.2007.10.013 · Cited by 7
An introduction to medical statistics for health care professionals: basic statistical tests
Thomas, E. (2005) · Musculoskeletal Care · doi:10.1002/msc.11 · Cited by 7
Bacon, S., Keller, A. J., Lavoie, K., & Campbell, T. S. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01010.x · Cited by 7
Short questionnaire for Parkinson's disease as a screening instrument
Setthawatcharawanich, S., Sathirapanya, P., Phabphal, K., & Limapichat, K. (2011) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2011.07.001 · Cited by 7
Enmi, J., Kudomi, N., Hayashi, T., Yamamoto, A., Iguchi, S., Moriguchi, T., Hori, Y., Koshino, K., Zeniya, T., Shah, N. J., et al. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7873 · Cited by 7
Hertig, E., & Jacobeit, J. (2010) · Climate Dynamics · doi:10.1007/s00382-010-0819-x · Cited by 7
Schmidlin, O. A., Zehnder, M., & Schmidlin, P. R. (2003) · Oral Microbiology and Immunology · doi:10.1034/j.1399-302x.2003.00041.x · Cited by 7
Detection of the motor points of the abdominal muscles
McCaughey, E. J., McLean, A. N., Allan, D., & Gollee, H. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-014-2966-y · Cited by 9
Kist, W. J., Slaghekke, F., Papanna, R. M., Johnson, A., Vandenbussche, F. P. H. A., Wolterbeek, R., & Oepkes, D. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2011.06.090 · Cited by 7
End-tidal versus transcutaneous measurement of PCO2 during voluntary hypo- and hyperventilation
Wollburg, E., Roth, W. T., & Kim, S. (2008) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2008.07.011 · Cited by 9
Machida, H., Komori, Y., Ueno, E., Shen, Y., Hirata, M., Kojima, S., Sato, M., Okazaki, T., Masukawa, A., Morita, S., et al. (2010) · Japanese Journal of Radiology · doi:10.1007/s11604-010-0472-7 · Cited by 7
Voicu, V. A., Gheorghe, M. C., Sora, D. I., Sârbu, C., & Medvedovici, A. V. (2011) · Bioanalysis · doi:10.4155/bio.11.83 · Cited by 7
Weber, F. P., Lindemann, M., Erbel, R. M., & Philipp, T. (1999) · Kidney & Blood Pressure Research · doi:10.1159/000025924 · Cited by 7
Williamson, J. P., & Emmert, G. L. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.07.011 · Cited by 7
Rengier, F., Delles, M., Unterhinninghofen, R., Ley, S., Müller–Eschner, M., Partovi, S., Geisbüsch, P., Dillmann, R., Kauczor, H., & von Tengg‐Kobligk, H. (2012) · International journal of cardiac imaging · doi:10.1007/s10554-012-0027-3 · Cited by 7
Xu, J., Wu, Y., Su, H., Hu, W., Li, J., Wang, W., Liu, X., & Cheng, X. (2014) · PLoS ONE · doi:10.1371/journal.pone.0100287 · Cited by 7
van den Heuvel, I. A., Vlasselaers, D., Wouters, P. J., Milants, I., Ellger, B., Vanhorebeek, I., & den Berghe, G. V. (2009) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e31819374b0 · Cited by 7
Harmon, K., Miao, H., Gomella, A. A., Bennett, E. E., Foster, B. A., Bhandarkar, P., & Wen, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/3031 · Cited by 7
Morin-Roy, F., Kauffmann, C., Tang, A., Hadjadj, S., Thomas, O., Piché, N., Elkouri, S., Yang, D. Y., Thérasse, É., & Soulez, G. (2014) · European Radiology · doi:10.1007/s00330-014-3175-0 · Cited by 7
Assessment of validity of INR system for patients with liver disease associated with viral hepatitis
Wei, Y., Li, J. H., Zhang, L., Zheng, D., Shi, B., & Cong, Y. (2009) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-009-0423-2 · Cited by 7
Inter-observer validation study of quantitative CT-osteodensitometry in total knee arthroplasty
Reilly, K., Munro, J. T., Pandit, S., Kreß, A., Walker, C. G., & PITTO, R. P. (2007) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-007-0351-6 · Cited by 7
Nižić, D. (2012) · Skeletal Radiology · doi:10.1007/s00256-011-1346-5 · Cited by 7
Mukherjee, S., & Chia, M. (2013) · International Journal of Sports Science & Coaching · doi:10.1260/1747-9541.8.1.77 · Cited by 9
Máxima velocidade aeróbia calculada pelo custo da frequência cardíaca: relação com a performance
da Silva, D. F., Sotero, R. C., Simões, H. G., & Machado, F. A. (2015) · Revista Andaluza de Medicina del Deporte · doi:10.1016/j.ramd.2014.06.001 · Cited by 9
Quantification of Refractive Error: Comparison of Autorefractor and Focometer
du Toit, R., SOONG, K., Brian, G. R., & Ramke, J. (2006) · Optometry and Vision Science · doi:10.1097/01.opx.0000230270.39804.54 · Cited by 7
Duin, L. K., Willekes, C., Vossen, M., Offermans, J. P. M., & Nijhuis, J. G. (2013) · Journal of Clinical Ultrasound · doi:10.1002/jcu.22039 · Cited by 7
Comparison of Two Non-mydriatic Fundus Cameras to Obtain Retinal Arterio-venous Ratio
Jürgens, C., Ittermann, T., Völzke, H., & Tost, F. (2014) · Ophthalmic Epidemiology · doi:10.3109/09286586.2014.949352 · Cited by 7
James, G. D., Gastrich, H. J., Valdimarsdottir, H. B., & Bovbjerg, D. H. (2008) · American Journal of Human Biology · doi:10.1002/ajhb.20737 · Cited by 7
Renal Manifestations of Fabry Disease
Warnock, D. G., Valbuena, C., West, M. L., & Oliveira, J. P. (2010) · Springer eBooks · doi:10.1007/978-90-481-9033-1_12 · Cited by 7
A simple thermal pain model for the evaluation of analgesic activity in healthy subjects
Khambam, S. R., Naidu, M. U. R., Rani, P., & Rao, T. K. (2012) · Journal of Anaesthesiology Clinical Pharmacology · doi:10.4103/0970-9185.94887 · Cited by 7
Validation of vital signs recorded via a new telecare system
Kornowski, R., Zlochiver, S., Botzer, L., Tirosh, R., Abboud, S., & Misan, S. (2003) · Journal of Telemedicine and Telecare · doi:10.1258/135763303771005225 · Cited by 7
Sehgal, K., Badrinath, Y., Tembhare, P. R., Subramanian, P. G., Talole, S. D., Kumar, A., Gadage, V., Mahadik, S., Ghogale, S., & Gujral, S. (2010) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.20515 · Cited by 7
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.