STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 32,801–32,900 of 47,868
Gannon, M. R., Park, M. H., Miller, K., Dodwell, D. J., Horgan, K. J., Clements, K., Medina, J., & Cromwell, D. A. (2023) · Cancer Epidemiology · doi:10.1016/j.canep.2023.102337 · Cited by 7
Harring, A. K. V., Røislien, J., Larsen, K., Guterud, M., Bugge, H. F., Sandset, E. C., Kristensen, D. V., & Hov, M. R. (2023) · Advances in Simulation · doi:10.1186/s41077-023-00245-4 · Cited by 11
Budzikowski, J. D., & Murray, W. M. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111501 · Cited by 8
Cone contrast test-HD: sensitivity and specificity in red–green dichromacy and the impact of age
Iizuka, T., Kawamorita, T., Handa, T., & Ishikawa, H. (2023) · Journal of the Optical Society of America A · doi:10.1364/josaa.480467 · Cited by 8
Macoir, J., & Hudon, C. (2023) · Applied Neuropsychology Adult · doi:10.1080/23279095.2023.2201448 · Cited by 7
Seligman, H., Patel, S., Alloula, A., Howard, J. P., Cook, C., Ahmad, Y., de Waard, G. A., Pinto, M. E., van de Hoef, T. P., Rahman, H., et al. (2023) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad030 · Cited by 8
Cruz, J., Khongkaew, P., Bertotto, J. P., Cárdenas, V., Alcalà, M., Nuchtavorn, N., Rojsanga, P., Suwanvecho, C., & Phechkrajang, C. M. (2023) · Phytochemical Analysis · doi:10.1002/pca.3231 · Cited by 7
Östenson, B., Ostenfeld, E., Edlund, J., Heiberg, E., Arheden, H., & Steding‐Ehrenborg, K. (2023) · PLoS ONE · doi:10.1371/journal.pone.0285592 · Cited by 7
Floyd, E., Adler, S. R., Crane, R. S., Brewer, J. A., Moran, P. J., Richler, R., Hartogensis, W., Kuyken, W., & Hecht, F. M. (2023) · Global Advances in Integrative Medicine and Health · doi:10.1177/27536130221149966 · Cited by 7
Sullivan, K. W., Metoyer, C. J., Winchester, L. J., Esco, M. R., & Fedewa, M. V. (2023) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12835 · Cited by 8
Liu, T., & Benjamin‐Neelon, S. E. (2023) · SLEEP · doi:10.1093/sleep/zsad160 · Cited by 10
Level of agreement between midwives and obstetricians performing ultrasound examination during labor
Fidalgo, A., Miguel, R. D., Fernández‐Buhigas, I., Aguado, A., Cuerva, M. J., Corrales, E., Rollé, V., Santacruz, B., Gil, M. M., & Poon, L. C. (2023) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.14956 · Cited by 7
Development and psychometric properties of the Serbian version of the Orofacial Esthetic Scale
Kostić, M. M., Ignjatović, A., Gligorijević, N. R., Jovanović, M., Đorđević, N. S., Đerlek, A., & Igić, M. (2023) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/jerd.13109 · Cited by 7
Lacomme, L., Guerbois, C., Fritz, H., Ganswindt, A., & Rey, B. (2023) · Conservation Physiology · doi:10.1093/conphys/coad053 · Cited by 9
Donners, R., Candito, A., Blackledge, M., Rata, M., Messiou, C., Koh, D., & Tunariu, N. (2023) · British Journal of Radiology · doi:10.1259/bjr.20230378 · Cited by 7
Ktistakis, E., Gleni, A., Tsilimbaris, M. K., & Plainis, S. (2023) · Clinical and Experimental Optometry · doi:10.1080/08164622.2023.2237974 · Cited by 7
Paranjape, V. V., Henao-Guerrero, N., Menciotti, G., & Saksena, S. (2023) · Frontiers in Veterinary Science · doi:10.3389/fvets.2023.1238549 · Cited by 7
Serra, M., Alceste, D., Hauser, F., Hulshof, P. J. M., Meijer, H. A. J., Thalheimer, A., Steinert, R. E., Gerber, P. A., Spector, A. C., Gerö, D., et al. (2023) · Frontiers in Nutrition · doi:10.3389/fnut.2023.1255499 · Cited by 10
In Vitro Validation of a Novel Continuous Intra-Abdominal Pressure Measurement System (TraumaGuard)
Tayebi, S., Wise, R., Zarghami, A., Malbrain, L., Khanna, A. K., Dąbrowski, W., Stiens, J. H., & Malbrain, M. L. N. G. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12196260 · Cited by 8
Fitze, D. P., Franchi, M. V., Peterhans, L., Frey, W. O., & Spörri, J. (2023) · Scientific Reports · doi:10.1038/s41598-023-46987-z · Cited by 7
Jeon, S., Kim, S., & Lee, K. C. (2023) · Journal of Craniofacial Surgery · doi:10.1097/scs.0000000000009862 · Cited by 7
Krombholz, S., Thomas, A., Delahaut, P., Bidlingmaier, M., Schilbach, K., Miller, G. D., & Thevis, M. (2023) · Growth Hormone & IGF Research · doi:10.1016/j.ghir.2023.101560 · Cited by 7
Kobia‐Acquah, E., Flitcroft, I., Lingham, G., Kerin, E. P., & Loughman, J. (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13256 · Cited by 8
Bai, M., Chen, J., Xu, Y., Feng, J. H., Ma, R., Jia, H., Xu, H., Liang, G., & Wei, H. (2023) · Scientific Reports · doi:10.1038/s41598-023-48975-9 · Cited by 8
Clina, J. G., Sayer, R. D., Friedman, J. E., Chui, T. K., Mehta, T. S., Rimmer, J. H., & Hill, J. O. (2023) · Journal of Physical Activity and Health · doi:10.1123/jpah.2023-0504 · Cited by 15
Martins, W. F., Severo, D. D. S., Longhi, D. A., & de Aragão, G. M. F. (2023) · Food Microbiology · doi:10.1016/j.fm.2023.104452 · Cited by 7
Boulanger, S. M., Mahna, A., Alenabi, T., Gatti, A. A., Culig, O., Hynes, L. M., & Chopp‐Hurley, J. N. (2023) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-023-04482-1 · Cited by 7
Validating the Fatigue Scale for Motor and Cognitive Function (FSMC) in chronic stroke
Goh, H., Stewart, J. C., & Becker, K. A. (2023) · Neurorehabilitation · doi:10.3233/nre-230189 · Cited by 8
A novel portable flip-phone based visual behaviour assay for zebrafish
Rodwell, V., Birchall, A., Yoon, H.-J., Kuht, H. J., Norton, W., & Thomas, M. G. (2024) · Scientific Reports · doi:10.1038/s41598-023-51001-7 · Cited by 7
Mayorga-Vega, D., Casado-Robles, C., Guijarro-Romero, S., & Viciana, J. (2024) · Journal of Sports Science and Medicine · doi:10.52082/jssm.2024.79 · Cited by 9
Prada, E. J. A., Ibarra, K. D. M., & Jiménez, K. L. D. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e26036 · Cited by 7
Zini, G., Chiusolo, P., Rossi, E. D., Stasio, E. D., Bellesi, S., Zà, T., Viscovo, M., Frioni, F., Ramundo, F., Pelliccioni, N., et al. (2024) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.14238 · Cited by 9
İnce, S., Laforest, R. A., Ashrafinia, S., Smith, A. M., Wahl, R. L., & Fraum, T. J. (2024) · Molecular Imaging and Biology · doi:10.1007/s11307-024-01909-x · Cited by 7
Belli, G., Russo, L., Mauro, M., Toselli, S., & Latessa, P. M. (2024) · Healthcare · doi:10.3390/healthcare12070738 · Cited by 11
Stefana, A., Marjanović, Z. J., & Dimitrijević, A. (2024) · Journal of Personality Assessment · doi:10.1080/00223891.2024.2326884 · Cited by 14
Imaging markers derived from MRI-based automated kidney segmentation
Kellner, E., Sekula, P., Lipovsek, J., Russe, M. F., Horbach, H., Schlett, C. L., Nauck, M., Völzke, H., Kröncke, T. J., Bette, S. J., et al. (2024) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.m2024.0040 · Cited by 12
Maqsood, R., Schofield, S. J., Bennett, A. N., Khattab, A., Bull, A. M. J., Fear, N. T., Boos, C. J., & Study, F. T. A. (2024) · PM&R · doi:10.1002/pmrj.13164 · Cited by 8
Yang, Y., Shen, X., & Cao, L. (2024) · Remote Sensing · doi:10.3390/rs16101662 · Cited by 7
Relationship between sense of coherence and depression, a network analysis
Kieraité, M., Novoselac, A., Bättig, J. J., Rühlmann, C., Bentz, D., Noboa, V., Seifritz, E., Egger, S., & Weidt, S. (2024) · Current Psychology · doi:10.1007/s12144-024-06034-0 · Cited by 8
Hu, P. C., Zhao, P., Qu, Y., Maslov, K., Chubiz, J. E. C., Tuuli, M. G., Stout, M. J., & Wang, L. V. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3403799 · Cited by 7
Claessens, J. L. J., Wanten, J. C., Bauer, N. J. C., Nuijts, R. M. M. A., Vrijman, V., Selek, E., Wouters, R. J., Reus, N. J., van Dorst, F. J. G. M., Findl, O., et al. (2024) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000001492 · Cited by 8
Son, B. B. B., Thi, D. N., Hoang, L. H., Tinh, T. D. H., & Nguyễn, T. T. B. (2024) · PLoS ONE · doi:10.1371/journal.pone.0304278 · Cited by 7
Eckstein, F., Wisser, A., Maschek, S., Wirth, W., Ladel, C. H., Bihlet, A. R., Knight, C., Somberg, K. A., & Zhao, L. (2024) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2024.05.012 · Cited by 7
Remote versus face-to-face fall risk assessment in home dwelling older adults: a reliability study
Toledano-Shubi, A., Hel-Or, H. Z., & Bahat, H. S. (2024) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2024.2367516 · Cited by 7
Side specific differences of Hounsfield-Units in the osteoporotic lumbar spine
Metzner, F., Reise, R., Heyde, C., von der Höh, N. H., & Schleifenbaum, S. (2024) · Journal of Spine Surgery · doi:10.21037/jss-23-121 · Cited by 7
Akbari, S., Tabassian, M., Pedrosa, J., Queirós, S., Papangelopoulou, K., & D’hooge, J. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3418030 · Cited by 9
Performance of the First-Trimester Cervical Consistency Index to Predict Preterm Birth
Mojica, C. H. B., Parra-Saavedra, M. A., Martínez-Vega, R. A., Díaz‐Martínez, L. A., Martinez-Portilla, R. J., Torres‐Torres, J., & Rincón‐Orozco, B. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13133906 · Cited by 7
Khan, A., Olajide, E., Friedrich, M., Holt, A., & Goehring, L. S. (2024) · Viruses · doi:10.3390/v16071091 · Cited by 7
Fan, J., Wang, H., Zhang, Y., Ma, C., & Zhou, B. (2024) · Journal of Clinical Hypertension · doi:10.1111/jch.14855 · Cited by 7
Julián‐Serrano, S., Koenig, M. R., Wang, T. R., Wesselink, A. K., Hatch, E. E., Wise, L. A., & Tucker, K. L. (2024) · American Journal of Epidemiology · doi:10.1093/aje/kwae203 · Cited by 8
Venkateshvaran, A., Bohlin, J., Kjellström, B., Bergström, E., Nelsson, A., Evaldsson, A. W., Rådegran, G., Arheden, H., & Ostenfeld, E. (2024) · Scientific Reports · doi:10.1038/s41598-024-68254-5 · Cited by 7
Paiva, R., Guadagnin, E. C., de Carvalho, J. E., Metsavaht, L. F., & Leporace, G. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112259 · Cited by 9
Lohmann, L. H., Hillebrecht, M., Schiemann, S., & Warneke, K. (2024) · Sports Medicine - Open · doi:10.1186/s40798-024-00755-z · Cited by 7
Barakat, R. M., Almohareb, R. A., Alharbi, A. O., Alhazmi, A., & Alomar, R. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13175199 · Cited by 7
Nalty, T., Patel, S. S., Bird, J. E., Lewis, V. O., & Lin, P. P. (2024) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000003257 · Cited by 7
Vieira, M. F., Bravo‐Valenzuela, N. J., Carvalho, F. H. C., Rocha, L. A., & Júnior, E. A. (2024) · Journal of Ultrasound in Medicine · doi:10.1002/jum.16609 · Cited by 9
Feasibility of Using Wearable Sensors to Measure Listening-Related Stress
Sarangi, L., & Johnson, J. A. (2024) · Perspectives of the ASHA Special Interest Groups · doi:10.1044/2024_persp-24-00073 · Cited by 8
Nowak, M. A., Henningsson, M., Davis, T., Chowdhury, N., Dennis, A., Fernandes, C. C., Thomaides-Brears, H. B., & Robson, M. D. (2024) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.29602 · Cited by 9
Chuang, C.-L., Lai, C.-L., Huang, A.-C., Su, P.-H., Chu, L.-P., Hsieh, K.-C., & Lu, H.-K. (2024) · Scientific Reports · doi:10.1038/s41598-024-80721-7 · Cited by 7
Garcia‐Molina, G., Matthews, C. K. B., Myers, A. M., Peterson, B., Strainis, E., Riedner, B. A., Vascan, A. M., Tononi, G., & Jones, S. (2024) · Journal of Sleep Research · doi:10.1111/jsr.14404 · Cited by 8
Villa, G., Bonfiglio, A., Galli, M., & Cimolin, V. (2024) · Sensors · doi:10.3390/s24247877 · Cited by 8
Unburned habitat essential for amphibian breeding persistence following wildfire
Bailey, L. L., Henderson, R., Estes‐Zumpf, W. A., Rhoades, C. C., Miller, E., Lujan, D. R., & Muths, E. (2024) · Global Ecology and Conservation · doi:10.1016/j.gecco.2024.e03389 · Cited by 8
Zhou, W., Huang, J., & Wang, M. (2024) · Fractal and Fractional · doi:10.3390/fractalfract9010014 · Cited by 7
Rueda, L. Y. M., Wang, H., Akagi, K., Dang, M., Vora, A. U., Qin, L., Lee, H. C., Patel, K. K., Lin, P., Mery, D. E., et al. (2025) · Cell Reports Medicine · doi:10.1016/j.xcrm.2024.101925 · Cited by 10
Coppadoro, A., Fracchia, R., Nova, A., Restivo, A., Lucchini, A., Bellani, G., Rezoagli, E., & Foti, G. (2024) · Pulmonology · doi:10.1080/25310429.2024.2411804 · Cited by 7
Huang, A.-C., Lu, H.-K., Liang, C.-W., Hsieh, K.-C., Tsai, Y.-S., & Lai, C.-L. (2025) · Frontiers in Nutrition · doi:10.3389/fnut.2025.1546499 · Cited by 10
Estimating Gait Speed in the Real World With a Head-Worn Inertial Sensor
Tasca, P., Salis, F., Rosati, S., Balestra, G., Mazzà, C., & Cereatti, A. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3542568 · Cited by 9
Littiere, T. D. O., da Costa, G. B., de Sales, N. A. A., de Carvalho, J. R. G., Rodriguez, I. D. M., Ramos, G. V., & Ferraz, G. D. C. (2025) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2025.105385 · Cited by 10
Hanigan, I., Yu, W., Yuen, C., Gopi, K., Knibbs, L. D., Cowie, C. T., Jalaludin, B. B., Cope, M., Riley, M. L., Heyworth, J. S., et al. (2025) · Environmental Modelling & Software · doi:10.1016/j.envsoft.2025.106378 · Cited by 8
Stefana, A., Fusar‐Poli, P., Vieta, E., & Youngstrom, E. A. (2025) · PLoS ONE · doi:10.1371/journal.pone.0311411 · Cited by 8
Evaluative Methodology for HRD Testing: Development of Standard Tools for Consistency Assessment
Jia, Z., Liu, Y., Qu, S., Li, W., Gao, L., Dong, L., Xing, Y., Cheng, Y., Fang, H., Yi, Y., et al. (2025) · Genomics Proteomics & Bioinformatics · doi:10.1093/gpbjnl/qzaf017 · Cited by 8
Vegas, L. P., van Lunteren, M., Lœuille, D., Morizot, C., Newsum, E., Ramiro, S., van Gaalen, F. A., Saraux, A., Claudepierre, P., Feydy, A., et al. (2025) · European Radiology · doi:10.1007/s00330-025-11432-4 · Cited by 7
Development and Validation of a Self-Administered Online Hearing Test
Vercammen, C., & Strelcyk, O. (2025) · Trends in Hearing · doi:10.1177/23312165251317923 · Cited by 9
Dalbro, S. E. J., Elsais, A., Rydning, S. L., Toft, M., Kerty, E., & Larsen, S. (2025) · Frontiers in Neurology · doi:10.3389/fneur.2025.1556314 · Cited by 7
Comparability evaluation of serum and plasma cytokine levels by multiplex bead-based flow cytometry
Feng, X., Zou, W., Li, P., Guo, K., Ma, Y., Hu, G., Kang, J., Yu, X., & Peng, M. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120351 · Cited by 8
Invasive validation of novel 1D models for computation of coronary fractional flow reserve
Taylor, D., Saxton, H., Xu, X., Yones, E., Aubinière-Robb, L., Adikari, T., Newman, T., Veer, M. V. ’., Keulards, D. C. J., Tonino, P. A. L., et al. (2025) · Cardiovascular Research · doi:10.1093/cvr/cvaf168 · Cited by 7
van Dijk, L. V., Ventura, J., Wahid, K. A., Zhu, L. L., McDonald, B. A., Ahmed, S. A., Sanders, K. L., Stieb, S., McCoy, L. A., Sharafi, C. S., et al. (2025) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2025.12.013 · Cited by 7
Schrover, I. M., Leiner, T., Klomp, D. W. J., Wijnen, J. P., Uiterwaal, C. S. P. M., Spiering, W., & Visseren, F. L. J. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24368 · Cited by 7
Measurement accuracy of different active tracking sequences for interventional MRI
Wech, T., Shea, S. M., Barbot, J., Vij, K., Pan, L., Lorenz, C. H., & Patil, S. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24374 · Cited by 7
Motion-compensated non-contact detection of heart rate
Yang, L., Liu, M., Dong, L., Zhao, Y., & Liu, X. (2015) · Optics Communications · doi:10.1016/j.optcom.2015.08.017 · Cited by 7
Allaway, H. C. M., Williams, N. I., Mallinson, R. J., Koehler, K., & Souza, M. J. D. (2014) · American Journal of Human Biology · doi:10.1002/ajhb.22649 · Cited by 8
Rajmil, L., Robles, N., Rodríguez-Arjona, D., Azuara, M., Codina, F. N., Raat, H., & Ravens‐Sieberer, U. (2014) · PLoS ONE · doi:10.1371/journal.pone.0114527 · Cited by 11
Steer, J. A., Hill, G. B., Srinivasan, S., Southern, J., & Wilson, A. P. R. (1997) · Journal of Hospital Infection · doi:10.1016/s0195-6701(97)90147-x · Cited by 7
Konstantinidis, S., Heldin, E., Chhatre, S., Velayudhan, A., & Titchener-Hooker, N. J. (2012) · Biotechnology Progress · doi:10.1002/btpr.1591 · Cited by 7
Introduction of Tissue Doppler Imaging Echocardiography—Based on Pulsed-wave Mode
Lin, F.-C., Hsieh, C., Lee, C., & Wen, M.-S. (2008) · Journal of Medical Ultrasound · doi:10.1016/s0929-6441(08)60049-1 · Cited by 7
Domingo, C., Canturri, E., Moreno, A., Espuelas, H., Vigil, L., & Luján, M. (2010) · Sensors · doi:10.3390/s100100491 · Cited by 7
Budak, Y., Huysal, K., Bulut, M., & Polat, M. (2013) · BMC Clinical Pathology · doi:10.1186/1472-6890-13-20 · Cited by 10
Evaluation of an algorithm for highly automated measurements of QT interval
Brockway, M. V., & Hamlin, R. L. (2011) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2011.05.004 · Cited by 7
Biochemical assessment of canine body cavity effusions using three bench‐top analysers
Hetzel, N., Papasouliotis, K., Dodkin, S. J., & Murphy, K. F. (2012) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2012.01240.x · Cited by 7
Karkabounas, A., Kitsiouli, E., Nakos, G., & Lekka, M. E. (2011) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.03.047 · Cited by 7
Papaioannou, T. G., Vardoulis, O., Protogerou, A. D., Konstantonis, G. D., Sfikakis, P. P., Stefanadis, C., & Stergiopulos, N. (2014) · Physiological Measurement · doi:10.1088/0967-3334/36/1/149 · Cited by 9
Three‐Dimensional Echocardiography for Quantitative Analysis of Left‐Ventricular Aneurysm
Jahnke, C., Foell, D., Heinrichs, G., Jung, B. A., Bley, T. A., Handke, M., Bode, C., & Geibel, A. (2009) · Echocardiography · doi:10.1111/j.1540-8175.2009.00972.x · Cited by 7
Which method to measure dentomaxillary discrepancy?
Regragui, S., Dakka, A., Regragui, F., Bouklouz, A., & Zaoui, F. (2010) · International Orthodontics · doi:10.1016/j.ortho.2009.12.005 · Cited by 7
Accu Chek Compact Plus blood glucometer evaluation
Kozar, J., Šimundić, A.-M., Nikolac, N., Žirović, M., & Topić, E. (2008) · Biochemia Medica · doi:10.11613/bm.2008.032 · Cited by 8
Determination of thigh volume in youth with anthropometry and DXA: Agreement between estimates
Coelho-e-Silva, M. J., Malina, R. M., Simões, F., Valente‐dos‐Santos, J., Martins, R. A., Ronque, Ê. R. V., Petróski, E. L., Minderico, C. S., Silva, A. M., Baptista, F., et al. (2013) · European Journal of Sport Science · doi:10.1080/17461391.2013.767945 · Cited by 7
Cherk, M. H., Ky, J., Yap, K. S. K., Campbell, P., McGrath, C. M., Bailey, M., & Kalff, V. (2012) · Journal of Nuclear Cardiology · doi:10.1007/s12350-012-9561-6 · Cited by 7
Bronze, M., Aitken, S. C., Wallis, C. L., Steegen, K., Stuyver, L. J., de Wit, T. F. R., & Stevens, W. S. (2013) · Journal of Virological Methods · doi:10.1016/j.jviromet.2013.08.015 · Cited by 7
Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL
Calderón, J. L. M., Pérez, J. V., Bustos, F., & Gómez, J. C. S. (2015) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2015.03.006 · Cited by 7
Low resource processing algorithms for laser Doppler blood flow imaging
Nguyen, H., Hayes‐Gill, B., Zhu, Y., Crowe, J. A., He, D., & Morgan, S. P. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.01.009 · Cited by 7
Internal calibration of gel dosimeters: A feasibility study
Trapp, J., Kairn, T., Crowe, S., & Fielding, A. L. (2009) · Journal of Physics Conference Series · doi:10.1088/1742-6596/164/1/012014 · Cited by 7
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.