STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 34,401–34,500 of 47,868
Mokhles, P., van den Bosch, A. E., McGhie, J. S., van Domburg, R. T., Ruys, T. P. E., Kauer, F., Geleijnse, M. L., & Roos‐Hesselink, J. W. (2013) · Echocardiography · doi:10.1111/echo.12172 · Cited by 6
Quantifying an Agreement Study
Liao, J. J. Z. (2015) · The International Journal of Biostatistics · doi:10.1515/ijb-2014-0030 · Cited by 6
Improved rapid assay of plasma uric acid by short-end injection capillary zone electrophoresis
Sotgia, S., Carru, C., Scanu, B., Pisanu, E., Sanna, M., Pinna, G. A., Gaspa, L., Deiana, L., & Zinellu, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3171-4 · Cited by 6
Sindhumol, S., Kumar, A., & Balakrishnan, K. (2013) · ISRN Biomedical Imaging · doi:10.1155/2013/473437 · Cited by 6
Massart, C., & Poirier, J. Y. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.10.025 · Cited by 6
Urine protein concentration estimation for biomarker discovery
Mistry, H. D., Bramham, K., Weston, A. J., Ward, M. A., Thompson, A., & Chappell, L. C. (2013) · Pregnancy Hypertension · doi:10.1016/j.preghy.2013.07.001 · Cited by 6
Logtenberg, S. J. J., Kleefstra, N., Groenier, K. H., Gans, R. O. B., & Bilo, H. J. G. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0088 · Cited by 8
Jaberzadeh, S., Scutter, S., & Zoghi, M. (2005) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/bf03178714 · Cited by 6
König, N., Reschke, A., Wolter, M., Müller, S., Mayer, F., & Baur, H. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.09.021 · Cited by 6
Eperjesi, F., & Holden, C. (2010) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-010-1500-0 · Cited by 6
Ståhlberg, M., Damgaard, M., Ersgård, D., Norsk, P., Karamanoglu, M., Linde, C. M., & Braunschweig, F. (2010) · Scandinavian Cardiovascular Journal · doi:10.3109/14017431003631987 · Cited by 6
Chung, J. W. N. C. H. F., Spigt, M., Knottnerus, J. A., & van MASTRIGT, R. (2008) · Urologia Internationalis · doi:10.1159/000144051 · Cited by 6
Learning effect of dark adaptation among normal subjects
Christoforidis, J. B., & Zhang, X. (2011) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-011-1706-9 · Cited by 6
Arterial function can be obtained by noninvasive finger pressure waveform
Bernardi, L., Gordin, D., Rosengård‐Bärlund, M., Mäkinen, V., Mereu, R., Toro, A. D., & Groop, P. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.03.179 · Cited by 6
Reproducibility of renal length measurements with 99mTc-DMSA SPECT.
Lin, E. Y., Connolly, L. P., Zurakowski, D., DiCanzio, J., Drubach, L. A., Mitchell, K., Tetrault, T., Laffin, S., & Treves, S. T. (2000) · PubMed · Cited by 6
Gislason, G., Gadsbøll, N., Quiñones, M. A., Køber, L., Seibæk, M., Burchardt, H., & Torp-Pedersen, C. T. (2005) · Echocardiography · doi:10.1111/j.1540-8175.2005.00157.x · Cited by 6
Vinyoles, E., Rodríguez-Blanco, T., de la Figuera, M., Colomé, J. M., Tafalla, M., Peláez, N. C., Martin, M., García-Alonso, J., Murillo, C., & Agudo-Ugena, J. (2012) · Blood Pressure · doi:10.3109/08037051.2012.686180 · Cited by 6
Lundqvist, E., Segelsjö, M., Andersson, A., Magnusson, A., & Biglarnia, A. (2012) · Acta Radiologica · doi:10.1258/ar.2012.120317 · Cited by 6
Sobrino, A., Tzikas, A., Freixa, X., Pulido, A., Chan, J. L. K., Garceau, P., Ibrahim, R., & Basmadjian, A. (2014) · Archivos de cardiología de México · doi:10.1016/j.acmx.2013.05.006 · Cited by 6
Kolias, T. J., Hagan, P. G., Chetcuti, S. J., Eberhart, D. L., Kline, N. M., Lucas, S. D., & Hamilton, J. D. (2014) · Echocardiography · doi:10.1111/echo.12512 · Cited by 6
Walsh, E., Adams, S., Chernipeski, J., Cloud, J., Gillies, E., Fox, R., Luckeroth, P., Rice, M., Salamanca, C., Sherman, B., et al. (2009) · American Journal of Critical Care · doi:10.4037/ajcc2009255 · Cited by 6
Soundararajan, N., & Russell, I. F. (2007) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2006.11.008 · Cited by 6
Validez y aplicabilidad de un nuevo método de registro para la hipertensión arterial
Mas-Heredia, M., Molés-Moliner, E., Paz, L. G., Kostov, B., Ortiz-Molina, J., Mauri-Vázquez, V., Menacho-Pascual, I., Cararach‐Salami, D., Sierra, C., & Sisó‐Almirall, A. (2014) · Revista Española de Cardiología · doi:10.1016/j.recesp.2013.12.019 · Cited by 6
Choosing Instruments for Research: an Evaluation of Two Activity Monitors in Healthy Women
Kip, C. V. K. E. (2013) · Journal of Novel Physiotherapies · doi:10.4172/2165-7025.1000171 · Cited by 9
Bergmann, J., Graham, S., Howard, N., & McGregor, A. H. (2013) · Measurement · doi:10.1016/j.measurement.2013.03.004 · Cited by 8
Kiris, A., Kırış, G., Turan, O. E., Öztürk, M., Şahin, M., İlter, A., Bektaş, O., Kutlu, M., Kaplan, Ş., & Gedikli, Ö. (2014) · The Anatolian Journal of Cardiology · doi:10.5152/akd.2014.5877 · Cited by 6
Quantitative Comparison of Myocardial Perfusion Defects using Different Reconstruction Algorithms
Naum, A. S., & Kleven‐Madsen, N. (2012) · Journal of Clinical & Experimental Cardiology · doi:10.4172/2155-9880.s5-002 · Cited by 6
Statistical Approach of Assessing the Reliability of Glucose Sensors: The GLYCENSIT Procedure
Herpe, T. V., Pelckmans, K., Brabanter, J. D., Janssens, F., Moor, B. D., & den Berghe, G. V. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200604 · Cited by 7
Chakravarthy, M., Narayan, S., Govindarajan, R., Jawali, V., & Subramanyam, R. (2009) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2009.06.015 · Cited by 6
Morris, M. G. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.10.010 · Cited by 6
Association between glomerular filtration rate and 1,25-dihydroxyvitamin D in cardiac surgery
Zittermann, A., Schulz, U., Lazouski, K., Fuchs, U., Gummert, J. F., & Börgermann, J. (2012) · Scandinavian Cardiovascular Journal · doi:10.3109/14017431.2012.725478 · Cited by 6
Evaluation of a strapless heart rate monitor during simulated flight tasks
Wang, Z., & Fu, S. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1101121 · Cited by 6
Assaying for circulating osteopontin in practice: a technical note: Fig. 1—
Constantinescu, D., Vornicu, M., Grigoriu, C., Cozmei, C., & Grigoriu, B. D. (2010) · European Respiratory Journal · doi:10.1183/09031936.00160609 · Cited by 6
Assessment of a new Goldmann applanation tonometer
Egli, M., Goldblum, D., Kipfer-Kauer, A., Rohrer, K., Tappeiner, C., Abegg, M. H., Berger, L., Schoetzau, A., & Iliev, M. E. (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.182469 · Cited by 6
New evidences about the strict relationship between the epicardial fat and the aerobic exercise
Monti, M., Renzi, P. D., Pirro, M. R., Borgognoni, F., & Vincentelli, G. M. (2015) · IJC Metabolic & Endocrine · doi:10.1016/j.ijcme.2015.01.004 · Cited by 6
The Quadriceps Angle: Reliability and Accuracy in a Fox ( V ulpes vulpes) Pelvic Limb Model
Miles, J. E., Frederiksen, J. V., Jensen, B. R., Kirpensteijn, J., Svalastoga, E., & Eriksen, T. (2012) · Veterinary Surgery · doi:10.1111/j.1532-950x.2011.00936.x · Cited by 6
Gama, A. M. C., Meyer, E., Gaudêncio, A. M. A. S., Grunauer, M., Amato, M. B. P., de Carvalho, C. R. R., & Barbas, C. S. V. (2001) · Artificial Organs · doi:10.1046/j.1525-1594.2001.06898.x · Cited by 6
Evaluation of the CT scanogram for assessment of craniofacial morphology
Lee, F. C. C., Noar, J. H., & Evans, R. D. (2010) · The Angle Orthodontist · doi:10.2319/110809-630.1 · Cited by 6
Meten van lichamelijke activiteit van kinderen: vragenlijsten vergeleken met versnellingsmeter
Schokker, D. F., Hekkert, K., Kocken, P., Cl, V. D. B., & de Vries, S. I. (2012) · TSG - Tijdschrift voor gezondheidswetenschappen · doi:10.1007/s12508-012-0148-z · Cited by 6
Zakeri, S. A., Panayotova, R., Borg, A. N., Miller, C., & Schmitt, M. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24342 · Cited by 6
Analysis of partial AZFc deletions in Malaysian infertile male subjects
Almeamar, H., Ramachandran, V., Ismail, P., Nadkarni, P., & Fawzi, N. (2012) · Systems Biology in Reproductive Medicine · doi:10.3109/19396368.2012.748851 · Cited by 6
Left-Ventricle Segmentation of SPECT Images of Rats
Jodoin, P., Pinheiro, F., Oudot, A., & Lalande, A. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2422263 · Cited by 6
Comprehensive brain analysis with automated high‐resolution magnetization transfer measurements
Wu, Y. G., Du, H., Storey, P., Glielmi, C. B., Malone, F., Sidharthan, S., Ragin, A. B., Tofts, P. S., & Edelman, R. R. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22835 · Cited by 6
Apfel, H. D., Shen, Z., Boxt, L. M., Barst, R. J., Gopal, A. S., Allan, L. D., Gersony, W. M., & King, D. L. (1997) · Cardiology in the Young · doi:10.1017/s1047951100004212 · Cited by 6
Effects of Delayed Laboratory Processing on Platelet Serotonin Levels
Sanner, J. E., Frazier, L. Q., & Udtha, M. (2011) · Biological Research For Nursing · doi:10.1177/1099800411416636 · Cited by 6
Kehl, S., Zirulnik, A., Debus, A., Sütterlin, M., Siemer, J., & Neff, W. (2011) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2011.30.8.1085 · Cited by 6
Biometric calculation of intraocular lens power for cataract surgery following pupil dilatation
Bansal, S., Quah, S. A., Turpin, T., & Batterbury, M. (2008) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2008.01700.x · Cited by 6
Chandrashekara, S., Renuka, P., & Suresh, K. P. (2012) · Indian Journal of Rheumatology · doi:10.1016/j.injr.2012.04.002 · Cited by 6
Perperidis, A., Cusack, D., McDicken, N., MacGillivray, T., & Anderson, T. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333690 · Cited by 6
Vogel, M. N., Schmücker, S., Maksimovic, O., Hartmann, J. T., Claussen, C. D., & Horger, M. (2012) · British Journal of Radiology · doi:10.1259/bjr/87835487 · Cited by 6
Rectal, Axillary or Skin Temperature in Newborns?
Placidi, G. (2014) · Journal of Pregnancy and Child Health · doi:10.4172/2376-127x.1000123 · Cited by 6
Daghighi, M. H., Poureisa, M., Arablou, F., & Fouladi, D. F. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.01.023 · Cited by 6
Rimbaș, M., Nicolau, A., Caraiola, S., Badea, C. G., Voiosu, M. R., & Băicuş, C. (2013) · PubMed · Cited by 6
Accuracy of an Automatic Infusion Controller (AutoClamp) for Intravenous Fluid Administration
Choi, G. J., Yoon, I. J., Lee, O. H., & Kang, H. (2015) · The Open Anesthesiology Journal · doi:10.2174/1874321801509010023 · Cited by 5
Evaluation of a Transcutaneous Bilirubinometer with Two Optical Paths in Chinese Preterm Infants
Siu, S. L., Siu, L., Chang, Y., & Lee, G. (2010) · Cited by 6
Inoue, Y., Kato, K., Kamata, S., Ishikawa, K., & Nakamura, M. (2015) · Documenta Ophthalmologica · doi:10.1007/s10633-015-9506-x · Cited by 6
Reliability of knee muscle strength and fatigue measurements
Surakka, J., Virtanen, A., Aunola, S., Mäentaka, K., & Pekkarinen, H. (2005) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 6
Validity and Reliability of the Achillometer®: An Ankle Dorsiflexion Measurement Device
Kleeblad, L. J., van Bemmel, A. F., Sierevelt, I. N., Zuiderbaan, H. A., & Vergroesen, D. A. (2016) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2015.11.006 · Cited by 6
Blood pressure measurement by pulse oxymetric method and comparison with conventional technique.
Khalili, G., Saghaei, M., & Abedini, M. (2002) · PubMed · Cited by 6
Stephan, P., Schmid, C., Freckmann, G., Pleus, S., Haug, C., & Müller, P. E. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815612490 · Cited by 6
Peschanski, N., Garcia, L., Delasalle, E., Mzabi, L., Rouff, E., Dautheville, S., Renai, F., Kieffer, Y., Lefèvre, G., Freund, Y., et al. (2015) · Emergency Medicine Journal · doi:10.1136/emermed-2015-205203 · Cited by 6
Alcohol Fixation of Induced Sputum Samples for Applications in Rural Communities
Dorman, S. C., Bussoli, M. A., & Ritz, S. A. (2010) · Canadian Respiratory Journal · doi:10.1155/2010/217678 · Cited by 6
Harshman, J. T., & Yezierski, E. J. (2015) · Journal of Chemical Education · doi:10.1021/acs.jchemed.5b00620 · Cited by 7
Olatunya, O. S., Olu‐Taiwo, A., Ogundare, E. O., Oluwayemi, I. O., Olaleye, A. O., Fadare, J. O., Adekoya-Benson, T., Fatunla, O. A., Agaja, O. T., Omoniyi, E., et al. (2016) · Journal of Tropical Pediatrics · doi:10.1093/tropej/fmw015 · Cited by 6
Netchacovitch, L., Thiry, J., Bleye, C. D., Dumont, E., Dispas, A., Hubert, C., Krier, F., Sacré, P., Évrard, B., Hubert, P., et al. (2016) · Talanta · doi:10.1016/j.talanta.2016.03.080 · Cited by 6
Lights and Shadows of the Actual European Guidelines on Bioanalytical Method Validation
Baldelli, S., Cattaneo, D., Fucile, S., & Clementi, E. (2014) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000083 · Cited by 6
Digital Pathology for the Validation of Tissue Microarrays in Peripheral T-cell Lymphomas
Pedersen, M. B., Riber‐Hansen, R., Nielsen, P. S., Bendix, K., Hamilton-Dutoit, S. J., d’Amore, F., & Steiniche, T. (2014) · Applied immunohistochemistry & molecular morphology · doi:10.1097/pai.0b013e3182a7d16d · Cited by 6
Huang, J., Liao, N., Savini, G., Li, Y., Bao, F., Ye, Y., Yu, A., & Wang, Q. (2014) · Cornea · doi:10.1097/ico.0000000000000329 · Cited by 6
di Giuseppe, R., Hirche, F., Montonen, J., Buijsse, B., Dierkes, J., Stangl, G. I., Boeing, H., & Weikert, C. (2012) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2012.011273 · Cited by 6
Shitara, K., Takai, Y., Ohta, M., Wakahara, T., Kanehisa, H., Fukunaga, T., & Kawakami, Y. (2009) · 体力科學 · doi:10.7600/jspfsm.58.463 · Cited by 6
Bench Study of a New Device to Display and Maintain Stable Artificial Airway Cuff Pressure
Howard, W. R. (2011) · Respiratory Care · doi:10.4187/respcare.00961 · Cited by 6
In-vitro evaluation of the PediaSat continuous central venous oxygenation monitoring system
Baulig, W., Spielmann, N., Zaiter, H., Lijovic, T., Béttex, D., Bürki, C., & Weiß, M. (2010) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e3283352201 · Cited by 6
Pereira, L. C., & Barros, M. (2016) · Journal of Medical Primatology · doi:10.1111/jmp.12214 · Cited by 7
Rosa, T. D. S., Simões, H. G., Rogero, M. M., Moraes, M. R., Denadai, B. S., Arida, R. M., Andrade, M. S., & Silva, B. M. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00122 · Cited by 6
Long-Term Follow-Up in Patients With Airway Chemical Intolerance
Ternestén‐Hasseus, E. (2016) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0000000000000695 · Cited by 6
Clinical evaluation of a new quantitative method for specific IgE antibodies.
Plebani, M., Borghesan, F., Bernardi, D., & Faggian, D. (1996) · PubMed · Cited by 6
Inoue, H., Kagoshima, M., & Kaibara, K. (2000) · The International Journal of Artificial Organs · doi:10.1177/039139880002300406 · Cited by 6
Gomes, L. E., Boeira, L., & Loss, J. F. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2016.1206207 · Cited by 6
DesJardins, A. M., Schiller, M., Eraqi, E., Samuels, A. N., & Galen, S. S. (2016) · Technology and Health Care · doi:10.3233/thc-161232 · Cited by 6
Clinical measurement of compensatory torsional eye movement during head tilt
Lim, H. W., Kim, J. H., Park, S. H., & Oh, S. Y. (2016) · Acta Ophthalmologica · doi:10.1111/aos.13150 · Cited by 6
Aina, A. S., Oluleye, T. S., & Olusanya, B. A. (2016) · Eye · doi:10.1038/eye.2016.181 · Cited by 6
Sedrez, J. A., Candotti, C. T., da Rosa, M. I. Z., Medeiros, F. D. S., Marques, M. T., & Loss, J. F. (2016) · Fisioterapia e Pesquisa · doi:10.1590/1809-2950/14854123022016 · Cited by 6
A Novel Method for Evaluating Postoperative Adhesions in Rats
Bove, G. M., Chapelle, S. L., Boyle, E., Mokler, D. J., & Hartvigsen, J. (2016) · Journal of Investigative Surgery · doi:10.1080/08941939.2016.1229367 · Cited by 6
Jang, D.-G., Ko, B.-H., Sunoo, S., Nam, S.-S., Park, H., & Bae, S.-K. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591929 · Cited by 6
Prediction of fractional flow reserve with angiographic DILEMMA score
Beton, O. (2016) · The Anatolian Journal of Cardiology · doi:10.14744/anatoljcardiol.2016.7379 · Cited by 6
Validation and comparison of shank and lumbar-worn IMUs for step time estimation
Johnston, W., Patterson, M., O’Mahony, N., & Caulfield, B. (2016) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2016-0120 · Cited by 6
'Argatroban' Monitoring in Human Plasma: aPTT and PiCT Studies on QCM-D vs 'Gold Standard'
Hussain, M. (2015) · Pharmaceutical and Biosciences Journal · doi:10.20510/ukjpb/3/i6/87834 · Cited by 6
Aortic arch mechanics measured with two-dimensional speckle tracking echocardiography
Teixeira, R. P., Monteiro, R., Baptista, R., Pereira, T. S., Ribeiro, M. A., Gonçalves, A., Cardim, N. M., & Gonçalves, L. M. M. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001336 · Cited by 6
LC/MS Based Monitoring of Endogenous Decay Markers for Quality Assessment of Serum Specimens
Mindt, N. A. S. (2015) · Journal of Proteomics & Bioinformatics · doi:10.4172/jpb.1000356 · Cited by 6
Statistics for Method Verification of Qualitative Assays in Clinical Microbiology
Wolk, D. M. (2017) · Clinical Microbiology Newsletter · doi:10.1016/j.clinmicnews.2017.03.008 · Cited by 6
Miyagawa, S., Fukuyama, H., Hirota, M., Yamaguchi, T., Kitamura, K., Endo, T., Kanda, H., Morimoto, T., & Fujikado, T. (2017) · Clinical ophthalmology · doi:10.2147/opth.s133070 · Cited by 7
Rosenberg, N., & Politch, J. (2017) · PLoS ONE · doi:10.1371/journal.pone.0174545 · Cited by 6
Gill, A. B., Hilliard, N., Hilliard, S., Graves, M. J., Lomas, D. J., & Shaw, A. S. (2017) · British Journal of Radiology · doi:10.1259/bjr.20160875 · Cited by 6
Wu, Y., Hsu, P.-Y., Lin, Y., Cheng, M., Ko, C., Huang, Y.-H., Yen, R., Chen, J., Lin, J., & Hsu, H. (2017) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000001720 · Cited by 8
Ishihara, M., Onoguchi, M., Taniguchi, Y., & Shibutani, T. (2017) · International journal of cardiac imaging · doi:10.1007/s10554-017-1205-0 · Cited by 6
On the Diffusion Process for Heart Rate Estimation from Face Videos Under Realistic Conditions
Pilz, C. S., Krajewski, J., & Blažek, V. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-66709-6_29 · Cited by 7
Computational assessment of model-based wave separation using a database of virtual subjects
Hametner, B., Schneider, M. C., Parragh, S., & Wassertheurer, S. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.08.027 · Cited by 6
Effect of FiO2 in the measurement of VO2 and VCO2 using the E-COXV metabolic monitor
Ferreruela, M., Raurich, J. M., Llompart‐Pou, J. A., Colomar, A., & Ayestarán, I. (2017) · Medicina Intensiva (English Edition) · doi:10.1016/j.medine.2017.08.007 · Cited by 6
Performance evaluation of the micro INR ® point‐of‐care INR ‐testing system
Joubert, J., van Zyl, M. C., & Raubenheimer, J. (2017) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12749 · Cited by 6
He, X., Sun, X.-M., Chen, G., Yang, Y.-L., Shi, Z., Xu, M., & Jian-xin, Z. (2017) · Respiratory Care · doi:10.4187/respcare.05750 · Cited by 6
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.