STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 34,801–34,900 of 47,868
Alvarez, J. R., Anesi, S., Czopowicz, M., & Corr, S. A. (2020) · Veterinary and Comparative Orthopaedics and Traumatology · doi:10.1055/s-0040-1716397 · Cited by 6
Differentiable Deconvolution for Improved Stroke Perfusion Analysis
de la Rosa, E., Robben, D., Sima, D. M., Kirschke, J. S., & Menze, B. H. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-59728-3_58 · Cited by 6
Computer-Aided Fracture Size Measurement in Orbital Fractures—An Alternative to Manual Evaluation
Saloniemi, M., Lehtinen, V., & Snäll, J. (2020) · Craniomaxillofacial Trauma & Reconstruction · doi:10.1177/1943387520962691 · Cited by 6
Measurement Instruments for Use in Oral Epidemiology
Bastos, J. L., Reichenheim, M. E., & de Moraes, C. L. (2020) · Textbooks in contemporary dentistry · doi:10.1007/978-3-030-50123-5_31 · Cited by 8
Zheng, X., Xu, G., Yan, W., Liang, R., Zhang, K., Tian, P., & Han, Z. (2020) · IEEE Access · doi:10.1109/access.2020.3032129 · Cited by 7
Zur Reliabilität von Wearable Devices am Beispiel einer Premium Multisport-Smartwatch
Wagner, M., Engel, F. A., Klier, K., Klughardt, S., Wallner, F., & Wieczorek, A. (2020) · German Journal of Exercise and Sport Research · doi:10.1007/s12662-020-00682-7 · Cited by 9
Gardener, S. L., Lyons‐Wall, P., Martins, R. N., & Rainey‐Smith, S. R. (2020) · Nutrients · doi:10.3390/nu12123605 · Cited by 6
Lasorsa, F. R., Caselli, M. C., Simonelli, I., Stefanini, S., Pasqualetti, P., & Rinaldi, P. (2021) · Folia Phoniatrica et Logopaedica · doi:10.1159/000513243 · Cited by 7
Lee, K., Warren, A., Abràmoff, M. D., Wahle, A., Whitmore, S. S., Han, I. C., Fingert, J. H., Scheetz, T. E., Mullins, R. F., Milan Sonka, A., et al. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109267 · Cited by 6
Comparison between two devices in the detection of corneal thickness changes after cataract surgery
Bernardo, M. D., Vitiello, L., Abbinante, G., Pascale, I. D., Capasso, L., Marotta, G., & Rosa, N. (2021) · Scientific Reports · doi:10.1038/s41598-021-86158-6 · Cited by 6
Nordbye‐Nielsen, K., Maribo, T., Wright, F. V., Rahbek, O., & Møller‐Madsen, B. (2021) · Disability and Rehabilitation · doi:10.1080/09638288.2021.1906332 · Cited by 6
31P‐MRS of healthy human brain: Measurement of guanosine diphosphate mannose at 7 T
Ren, J., & Sherry, A. D. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4576 · Cited by 6
Rizzo, J. Â., Filho, E. D. A. R., Gonçalves, A. V., Albuquerque, L. C. B. D. B., de Albuquerque, E. M., de Albuquerque, C. G., de Almeida, A. H. S., Peixoto, D. M., & Correia, M. A. D. V. (2021) · Pediatric Allergy and Immunology · doi:10.1111/pai.13610 · Cited by 6
Manjavong, M., Limpawattana, P., & Sawanyawisuth, K. (2021) · Dementia and Geriatric Cognitive Disorders Extra · doi:10.1159/000517821 · Cited by 10
Cohen, O. S., John, M. M., Kaufman, A. E., Kundel, V., Burschtin, O. E., Khan, S., Fayad, Z. A., Mani, V., & Shah, N. A. (2021) · Sleep And Breathing · doi:10.1007/s11325-021-02480-3 · Cited by 6
Kang, S. H., & Park, M. H. (2021) · Dementia and Neurocognitive Disorders · doi:10.12779/dnd.2021.20.4.41 · Cited by 6
Lin, I.-I., Chen, Y.-L., & Chuang, L.-L. (2021) · JMIR Formative Research · doi:10.2196/28040 · Cited by 6
Kersey, J., Terhorst, L. A., Hammel, J. M., Baum, C. M., Toglia, J. P., O’Dell, M. W., Heinemann, A. W., McCue, M. P., & Skidmore, E. R. (2021) · Clinical Rehabilitation · doi:10.1177/02692155211052188 · Cited by 6
dos Anjos, T. M., Veado, J. C. C., Castro, M. C. N., Diniz, S. A., Rocha, G. S. L., Silva, E. F., Araújo, C. A. V., Freitas, C. D., Maia, M. Q., & Tavares, C. A. P. (2014) · Arquivo Brasileiro de Medicina Veterinária e Zootecnia · doi:10.1590/1678-6722 · Cited by 7
Comparison of Two Methods of Processing Induced Sputum: Selected Versus Entire Sputum
Belda, J., Parameswaran, K., & Hargreave, F. E. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.2.15824 · Cited by 6
Tsantes, A. G., Konstantinidi, A., Parastatidou, S., Ioakeimidis, G., Tsante, K. A., Mantzios, P. G., Kriebardis, A. G., Gialeraki, A. E., Houhoula, D. P., Iacovidou, N. M., et al. (2022) · European Journal Of Haematology · doi:10.1111/ejh.13812 · Cited by 6
A machine learning approach for computation of cardiovascular intrinsic frequencies
Alavi, R., Wang, Q., Gorji, H., & Pahlevan, N. M. (2023) · PLoS ONE · doi:10.1371/journal.pone.0285228 · Cited by 7
FULLER, J. T., Archer, J., Buckley, J. D., Tsiros, M. D., & Thewlis, D. (2015) · Skeletal Radiology · doi:10.1007/s00256-015-2227-0 · Cited by 6
Long-term Reproducibility of Screening for Glaucoma With FDT-Perimetry
Horn, F. K., Link, B., Mardin, C. Y., Jünemann, A. G., & Martus, P. (2007) · Journal of Glaucoma · doi:10.1097/ijg.0b013e318057523c · Cited by 6
Kaiser, H. J., Kuehl, H., Koch, K., Nowak, B., Buell, U., & Schaefer, W. M. (2007) · Nuklearmedizin - NuclearMedicine · doi:10.1055/s-0037-1616622 · Cited by 6
Prediction of maximal oxygen uptake by bioelectrical impedance analysis in overweight adolescents.
Roberts, M. D., Drinkard, B., Ranzenhofer, L. M., Salaita, C. G., Sebring, N. G., Brady, S. M., Pinchbeck, C., Hoehl, J., Yanoff, L. B., Savastano, D. M., et al. (2009) · PubMed · Cited by 9
Möller, M., Schläfke, M. E., & Schäfer, T. (2002) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1046/j.1439-054x.2002.02179.x · Cited by 6
Alunni, G., Giorgi, M., Sartori, C., Garrone, P., Conrotto, F., D’Amico, M., Scacciatella, P., Andriani, M., Levis, M., & Marra, S. (2010) · Echocardiography · doi:10.1111/j.1540-8175.2009.01099.x · Cited by 6
Mapa Mínimo de Relações do Idoso: análise de reprodutibilidade
Domingues, M. A. R. D. C., Domingues, R., Ordonez, T. N., da Silva, B. L., de Barros, T. C., & Cachioni, M. (2011) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · doi:10.23925/2176-901x.2011v14i4p153-166 · Cited by 6
Williams, A., Peachey, L., & Christley, R. (2012) · Equine Veterinary Education · doi:10.1111/j.2042-3292.2011.00379.x · Cited by 6
Sánchez, R., Jaramillo, L. E., & Gómez–Restrepo, C. (2008) · Redalyc (Universidad Autónoma del Estado de México) · Cited by 6
Braždžionytė, J., & Macas, A. (2006) · PubMed · Cited by 6
New Percentage Body Fat Prediction Equations for Japanese Males
Kagawa, M., Kerr, D. A., & Binns, C. W. (2006) · Journal of PHYSIOLOGICAL ANTHROPOLOGY · doi:10.2114/jpa2.25.275 · Cited by 6
Wang, J., Bunce, C., & Lee, H.-M. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080601-10 · Cited by 6
Time course of carbon monoxide transfer factor after breath-hold diving.
Prediletto, R., Fornai, E., Catapano, G., Carli, C., Garbella, E., Passera, M., Cialoni, D., Bedini, R., & L’Abbate, A. (2009) · PubMed · Cited by 6
Peripheral venous pressure predicts central venous pressure poorly in pediatric patients
Leipoldt, C. C. P., McKay, W. P. S., Clunie, M., & Miller, G. G. (2006) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03021582 · Cited by 6
A comparison of two impedance cardiographs using head-up tilting and trend analysis.
Critchley, L. A. H., Zhang, Y., Critchley, J., & Chung, R. C. K. (2002) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1016347102209 · Cited by 6
Validation of the pectoralis minor length test: A novel approach
Weber, C., Enzler, M., Wieser, K., & Swanenburg, J. (2015) · Manual Therapy · doi:10.1016/j.math.2015.09.015 · Cited by 6
Prediction of one repetition maximum strength (1RM) based on a submaximal strength in adult males
Materko, W., & Santos, E. L. (2009) · Isokinetics and Exercise Science · doi:10.3233/ies-2009-0353 · Cited by 6
Rest versus stress ejection fraction on gated myocardial perfusion SPECT.
Wheat, J. M., & Currie, G. M. (2005) · PubMed · Cited by 6
Thomas, N., Rebekah, G. J., Santhanam, S., Kumar, M., Kuruvilla, K. A., & Jana, A. K. (2012) · Acta Paediatrica · doi:10.1111/apa.12010 · Cited by 6
A radiopaque marker technique for measuring gastrointestinal transit in subjects with an ileostomy
Goldberg, P. A., Kamm, M. A., & Nicholls, R. J. (1996) · Digestive Diseases and Sciences · doi:10.1007/bf02100118 · Cited by 6
COLLINGWOOD, R., Bermudez, E., & Fischell, T. A. (2009) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2009.00448.x · Cited by 6
Limbs Anthropometry of Singleton Chinese Newborns of 28–42 Weeks’ Gestation
Fok, T. F., Hon, K. E., Ng, P. C., Wong, E. Y. L., So, H., Lau, J. T. F., Chow, C. B., & Lee, W. H. (2005) · Neonatology · doi:10.1159/000088195 · Cited by 6
Papadaki, A., & Scott, J. A. (2007) · Journal of Human Nutrition and Dietetics · doi:10.1111/j.1365-277x.2007.00809.x · Cited by 9
Ornetti, P., Maillefert, J.-F., Paternotte, S., Dougados, M., & Gossec, L. (2010) · Joint Bone Spine · doi:10.1016/j.jbspin.2010.10.014 · Cited by 6
Nakagawa, M., Hara, M., Oshima, H., Shibamoto, Y., Mizuno, K., & Asano, M. (2008) · Radiation Medicine · doi:10.1007/s11604-008-0237-8 · Cited by 6
Noble, G. L., Ahlberg, A. W., Kokkirala, A. R., Cullom, S. J., Bateman, T. M., Cyr, G., Katten, D. M., Tadeo, G., Case, J. A., O’Sullivan, D. M., et al. (2009) · Journal of Nuclear Cardiology · doi:10.1007/s12350-008-9022-4 · Cited by 6
Giraldez, M. J., Yebra‐Pimentel, E., Parafita, M. Á., Escandón, S., Cerviño, A., & Pérez, M. V. (2000) · International Contact Lens Clinic · doi:10.1016/s0892-8967(01)00052-9 · Cited by 6
Applicability of a different estimation equation of glomerular filtration rate in Turkey
Altıparmak, M. R., Seyahi, N., Trabulus, S., Yalın, S. F., Bolayırlı, M., Andican, Z. G., Süleymanlar, G., & Serdengeçtı, K. (2013) · Renal Failure · doi:10.3109/0886022x.2013.817278 · Cited by 6
In vivo validation of the time domain velocity measurement technique of blood flow in human fetuses
Alcázar, J. L., & Laparte, C. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00234-2 · Cited by 6
Sairaku, A., Yoshida, Y., Hirayama, H., Nakano, Y., Nanasato, M., Kamiya, H., Kondo, N., & Kihara, Y. (2013) · Sleep Medicine · doi:10.1016/j.sleep.2013.04.003 · Cited by 6
Hormiga, C. M., Camargo, D. M., & Orozco, L. C. (2008) · Biomédica · doi:10.7705/biomedica.v28i3.73 · Cited by 6
Inaccuracies in estimated glomerular filtration rate in one Australian renal centre
Brown, M. A., Pirabhahar, S., Kelly, J. J., Mangos, G., MACKENZIE, C., Mcconachie, P., JANSSEN, J., & Smart, R. (2011) · Nephrology · doi:10.1111/j.1440-1797.2011.01453.x · Cited by 6
A Prospective Study to Validate an Impairment Questionnaire for Major Trauma Survivors
Marshall, S., Gray, D., Wilson, K. G., Yelle, J.-D., Hébert, P. C., O’Rourke, K., & Jamshidi, M. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000253256.11686.23 · Cited by 6
de Jonge, G. J., van Ooijen, P. M. A., van der Vleuten, P. A., Lubbers, D. D., Kasemier, J. H., de Bock, G. H., & Oudkerk, M. (2009) · European Radiology · doi:10.1007/s00330-009-1506-3 · Cited by 6
Craig, A. J., Britten, A. J., Heenan, S. D., & Irwin, A. G. (2011) · European Radiology · doi:10.1007/s00330-011-2157-8 · Cited by 6
Neumeister, V., Jaroß, W., Henker, J., & Kaltenborn, G. (1998) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.206 · Cited by 6
Aristizábal, J. C., Restrepo, M. T., & López, A. (2008) · Biomédica · doi:10.7705/biomedica.v28i3.78 · Cited by 6
Trujillano, J., Badía, M., March‐Llanes, J., Pozo, Á. R., Serviá, L., & Tello, A. S. (2005) · Medicina Intensiva · doi:10.1016/s0210-5691(05)74198-x · Cited by 19
QT Dispersion: Comparison of Orthogonal, Quasi‐orthogonal, and 12‐Lead Configurations
Beuve, C. S., Badilini, F., Maison‐Blanche, P., Kedra, A., & Coumel, P. (1999) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1999.tb00056.x · Cited by 6
Hansson, E., Manjer, J., & Ringberg, A. (2014) · Indian Journal of Plastic Surgery · doi:10.4103/0970-0358.129625 · Cited by 6
Reliability of a noninvasive device to measure systemic hemodynamics in hemodialysis patients
Motiwala, S., Brewster, U. C., Perazella, M. A., & Peixoto, A. J. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000189789.05736.16 · Cited by 6
Nikischin, W., Herber-Jonat, S., von Bismarck, P., Lange, M., & Grabitz, R. G. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000260244.32756.bb · Cited by 6
Continuous cardiac output monitoring
Kuper, M. (2004) · Current Anaesthesia and Critical Care · doi:10.1016/j.cacc.2004.11.004 · Cited by 6
Fregonezi, G., Resqueti, V., Vigil, L., Calaf, N., & Casán, P. (2012) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0b013e318259b6a5 · Cited by 6
Nievas, I. F. F., Spentzas, T., & Bogue, C. W. (2013) · Journal of Intensive Care Medicine · doi:10.1177/0885066613475422 · Cited by 6
Hove, J. D., Kofoed, K. F., Wu, H. M., Holm, S., Friberg, L., Meyer, C. G., Aldershvile, J., Hesse, B., & Kelbæk, H. (2003) · Journal of Nuclear Cardiology · doi:10.1067/mnc.2003.30 · Cited by 6
A comparison between radiometric and fluorimetric methods for measuring SSAO activity
Gella, A., Solé, M., Bolea, I., Ventriglia, M., Siotto, M., Durany, N., Squitti, R., & Unzeta, M. (2013) · Journal of Neural Transmission · doi:10.1007/s00702-013-0987-z · Cited by 6
Airway Luminal Diameter and Shape Measurement by Means of an Intraluminal Fiberoptic Probe
Jowett, N., Weersink, R., Zhang, K., Campisi, P., & Forte, V. (2008) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.134.6.637 · Cited by 6
Lower-limb and whole-body tissue composition assessment in healthy active older women
Rance, M., Morio, B., Courteix, D., Bedu, M., Praagh, E. V., & Duché, P. (2006) · Annals of Human Biology · doi:10.1080/03014460500446319 · Cited by 10
Paiva, I., do Amaral, T. F., & Barros, H. (2004) · Journal of Human Nutrition and Dietetics · doi:10.1111/j.1365-277x.2004.00563.x · Cited by 6
Fat-free weight prediction in morbidly obese females
Bucaloiu, I. D., & Perkins (2011) · International Journal of Nephrology and Renovascular Disease · doi:10.2147/ijnrd.s24173 · Cited by 7
Effect of sampling interval on the use of “doubly labeled” water for measuring CO2 production
Yu, L., Sinha, A. K., & Previs, S. F. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.09.042 · Cited by 6
Dynamic Contour Tonometry: Handheld versus Slit-lamp–Mounted
Knecht, P. B., Bosch, M. M., Menke, M. N., Bachmann, L. M., Funk, J., & Kaufmann, C. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.02.006 · Cited by 7
SNAP II versus BIS VISTA monitor comparison during general anesthesia
Hrelec, C. M., Puente, E., Bergese, S. D., & Dzwonczyk, R. R. (2010) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-010-9246-0 · Cited by 7
Radioangioscintigraphy and Doppler Echocardiography in the Quantification of Left-to-Right Shunt
Malčić, I., Senecić, I., Težak, S., Ivancević, D., & Kniewald, H. (2000) · Pediatric Cardiology · doi:10.1007/s002460010049 · Cited by 6
Shih, P.-C., Hung, Y.-C., Chen, Y.-L., Tsai, H.-J., Chen, C.-Y., & Huang, C. (2012) · Journal of Surgical Research · doi:10.1016/j.jss.2012.07.012 · Cited by 6
Noninvasive continuous blood pressure measurement: A clinical evaluation of the Cortronic APM 770
Jong, J. R., Tepaske, R., Scheffer, G., Ros, H. H., Sipkema, P., & de Lange, J. J. (1993) · The Journal of Clinical Monitoring · doi:10.1007/bf01627632 · Cited by 6
Osgood, S. L., Jahr, J. S., Desai, P., Tsukamoto, J. S., & Driessen, B. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000143337.05366.cd · Cited by 6
Smeets, R. (2008) · European Journal of Pain · doi:10.1016/j.ejpain.2008.08.005 · Cited by 6
Dutt‐Ballerstadt, R., Evans, C., Gowda, A., & McNichols, R. J. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0033 · Cited by 6
Comparison of glomerular filtration rate and serum creatinine in renal transplant patients
Butterworth, P. C., Harris, K. P. G., & Nicholson, M. L. (1997) · Transplantation Proceedings · doi:10.1016/s0041-1345(97)00674-x · Cited by 6
Elgeti, T., Proquitt�, H., Rogalla, N. E., Mews, J., Hamm, B., Schmalisch, G., & Rogalla, P. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000255817.54192.eb · Cited by 6
A Wearable Technology Revisited for Cardio-Respiratory Functional Exploration
Fontecave-Jallon, J., Guméry, P.-Y., Calabrèse, P., Briot, R., & Baconnier, P. (2013) · International Journal of E-Health and Medical Communications · doi:10.4018/jehmc.2013010102 · Cited by 6
González-Ortı́z, M., Martínez‐Abundis, E., & Pascoe-González, S. (1999) · Archives of Medical Research · doi:10.1016/s0188-0128(99)00044-5 · Cited by 6
van der Meer, N. J. M., Noordegraaf, A. V., Kamp, O., VRIES, P. M. J. M. D., & van der Meer, N. J. M. (1999) · Angiology · doi:10.1177/000331979905000202 · Cited by 6
A beta-scintillator for surface measurements of radiotracer kinetics in the intact rodent cortex
Wyss, M. T., Obrist, N. M., Haiss, F., Eckert, R., Stanley, R. P., Burger, C., Buck, A., & Weber, B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.077 · Cited by 6
Edwards, M. H., & Cho, P. (1996) · Journal of The British Contact Lens Association · doi:10.1016/s0141-7037(96)80032-2 · Cited by 6
Arfeen, Z., Maran, N., Simón, E., & McClure, J. H. (1996) · International Journal of Obstetric Anesthesia · doi:10.1016/s0959-289x(96)80026-4 · Cited by 6
Kommers, S. C., Moghimi, M., van de Ven, L., & Forouzanfar, T. (2014) · British Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.bjoms.2014.04.008 · Cited by 6
7Li MR measures of blood lithium—correlation with chemical analysis data
Pierson, E., Luterbach, K., Rzepka, E., & Ramaprasad, S. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.08.030 · Cited by 6
CARTER, H. B., Landis, P., Wright, E. J., Parsons, J. K., & Metter, E. J. (2005) · The Journal of Urology · doi:10.1097/01.ju.0000158372.45211.47 · Cited by 6
Solnica, B. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.156 · Cited by 6
Validity of the Adaptive Filter for Accurate Measurement of Cardiac Output in Impedance Cardiography
Ono, T., Yasuda, Y., Ito, T., Barros, A. K., Ishida, K., Miyamura, M., Yoshizawa, M., & Yambe, T. (2004) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.202.181 · Cited by 6
Holweger, K., Lipp, H., Beijnen, J. H., Bokemeyer, C., & Hartmann, J. T. (2010) · Cancer Chemotherapy and Pharmacology · doi:10.1007/s00280-010-1537-0 · Cited by 6
Comparison of different methodologies for CD4 estimation in a clinical setting
Jeganathan, S., Bansal, M., Smith, D., & Gold, J. (2008) · HIV Medicine · doi:10.1111/j.1468-1293.2008.00544.x · Cited by 6
Iyriboz, Y., & Hearon, C. M. (1994) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf02908856 · Cited by 6
Wuest, W., Lell, M., May, M. S., Scharf, M., Schlundt, C., Achenbach, S. S., Uder, M., & Schmid, A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0119788 · Cited by 6
Reliability of Transportable Instruments for Assessment of Infant Length
Byrne, M. W., & Lenz, E. R. (2002) · Journal of Nursing Measurement · doi:10.1891/jnum.10.2.111.52554 · Cited by 6
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.