STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 37,501–37,600 of 47,868
Davidson, A. W., Scott, R. F., & Mitchell, K. W. (2004) · Documenta Ophthalmologica · doi:10.1007/s10633-004-3831-9 · Cited by 4
Soares, P. P. D. S., Ushizima, M. R., Krieger, E. M., & Irigoyen, M. C. (2005) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2005000600018 · Cited by 4
Concordancia de la evaluación objetiva y subjetiva en la predicción y hallazgo de vía aérea difícil
Meléndez, H. J., Leal, D., & Ramírez, D. A. M. (2010) · Colombian Journal of Anesthesiology · doi:10.1016/s0120-3347(10)81003-2 · Cited by 4
Mukaide, D., Tabata, T., Kinoshita, K., 横井, 博., Fujiwara, W., Inami, O., Sugishita, Y., Ukai, G., Yoshinaga, M., Kamada, T., et al. (2013) · Journal of Cardiology · doi:10.1016/j.jjcc.2013.01.007 · Cited by 4
Makhoul, I. R., Smolkin, T., Zinder, O., Diamond, E., Tamir, A., & Sujov, P. O. (2005) · Acta Paediatrica · doi:10.1080/08035250510027741 · Cited by 4
Shin, E., García‐García, H. M., Sarno, G., Thuesen, L., Dudek, D., Ormiston, J. A., & Serruys, P. W. J. C. (2011) · International journal of cardiac imaging · doi:10.1007/s10554-010-9779-9 · Cited by 4
The intraindividual agreement of the bone density of the human proximal tibia
Boos, C., Fink, K., Stomberg, P., Köller, W., Igl, B., & Russlies, M. (2007) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/j.aanat.2006.11.010 · Cited by 4
Rabald, S., Hagendorff, A., Pfeiffer, D., Zimmer, H., & Deten, A. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.04.016 · Cited by 4
Urethral sleeve sensor: a non-withdrawal method to measure maximum urethral pressure
Tan-Kim, J., Weinstein, M. M., & Nager, C. W. (2010) · International Urogynecology Journal · doi:10.1007/s00192-009-1084-6 · Cited by 4
Automatic evaluation of the Valsalva sinuses from cine-MRI
Blanchard, C., Lalande, A., Sliwa, T. M., Bouchot, O., & Voisin, Y. (2011) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-011-0283-6 · Cited by 4
Mas, I. D., Biscardi, A. G., & Ripamonti, U. (2002) · Journal of Clinical Densitometry · doi:10.1385/jcd:5:3:313 · Cited by 4
Accurate Measurements of Oxygen Saturation in Neonates: Paired Arterial and Venous Blood Analyses
Shiao, S.-Y. P. K. (2005) · Newborn and Infant Nursing Reviews · doi:10.1053/j.nainr.2005.09.001 · Cited by 4
Asao, K., Takaki, A., Tominaga, M., & Sasaki, M. (2011) · Annals of Nuclear Medicine · doi:10.1007/s12149-011-0548-1 · Cited by 4
Mofidi, R., Crotty, T. B., McCarthy, P., Mehigan, D., Sheehan, S., & Keaveny, T. V. (2004) · International Journal of Angiology · doi:10.1007/s00547-004-1034-6 · Cited by 4
Comparaison de l’IPSS et de l’ICS male SF dans le bilan initial des troubles urinaires
Perrin, P., Nemoz, C., Paparel, P., & Ruffion, A. (2008) · The French Journal of Urology · doi:10.1016/j.purol.2008.03.034 · Cited by 4
Statistical analysis of medical data. Part II
SHUFELT, C. L., & Hachamovitch, R. (2000) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(00)70015-8 · Cited by 4
Hayward, L., Oeppen, R. S., Grima, A., Royle, G. T., Rubin, C. Z., & Cutress, R. (2011) · Annals of The Royal College of Surgeons of England · doi:10.1308/003588411x579829 · Cited by 4
Smale, K. B., McIntosh, E. I., & Vallis, L. A. (2013) · Journal of Applied Gerontology · doi:10.1177/0733464813515088 · Cited by 5
Population Pharmacokinetics of Nevirapine in Thai HIV-Infected Patients
Wattanakul, T., Avihingsanon, A., Manosuthi, W., & Punyawudho, B. (2013) · Antiviral Therapy · doi:10.3851/imp2741 · Cited by 4
Feasibility of Using the Marginal Blood Vessels as Reference Landmarks for CT Colonography
Wei, Z., Yao, J., Wang, S., Liu, J., Dwyer, A. J., Pickhardt, P. J., Nowinski, W. L., & Summers, R. M. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.10463 · Cited by 4
Use of pretransformation to cope with extreme values in important candidate features
Boulesteix, A., Guillemot, V., & Sauerbrei, W. (2011) · Biometrical Journal · doi:10.1002/bimj.201000189 · Cited by 6
Rafamantanantsoa, H. H., Ebine, N., Yoshioka, M., YOSHITAKE, Y., Tanaka, H., & Saitoh, S. (2003) · Journal of Clinical Biochemistry and Nutrition · doi:10.3164/jcbn.33.33 · Cited by 4
Moralidis, E., Spyridonidis, T., Arsos, G. A., Apostolopoulos, D. J., Karatzas, N. D., Vassilakos, P. J., & Karakatsanis, K. (2004) · Nuclear Medicine Communications · doi:10.1097/01.mnm.0000130245.52562.bf · Cited by 4
OncoTREAT—a software assistant for oncological therapy monitoring
Bornemann, L., Kuhnigk, J., Dicken, V., Zidowitz, S., Wormanns, D., Shin, H., Krass, S., & Peitgen, H. (2005) · International Congress Series · doi:10.1016/j.ics.2005.03.050 · Cited by 4
Magnetic resonance imaging of rectal volume in patients with irritable bowel syndrome
Palma, L. D., Coletta, M., Tomba, C., Forzenigo, L. V., Biondetti, P. R., & Basilisco, G. (2011) · Digestive and Liver Disease · doi:10.1016/j.dld.2011.01.004 · Cited by 4
Automatic quantification of posterior capsule opacification
Barman, S. A., Uyyanonvara, B., Boyce, J. F., Sanguinetti, G., Hollick, E. J., Meacock, W. R., Spalton, D. J., & Papliński, A. P. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.387597 · Cited by 4
Évaluation du Micral Test® en vue du dépistage de la microalbuminurie en biologie délocalisée
Szymanowicz, A., Blanc-Bernard, E., Roche, C., Neyron, M.-J., Perrin, M., & Nourdine, K. (2008) · Immuno-analyse & Biologie Spécialisée · doi:10.1016/j.immbio.2008.02.008 · Cited by 4
Uno, K., Seo, Y., Ishizu, T., Inaba, T., Sakamaki, F., Iida, N., Nakajima, H., Oyake, Y., Ohtsuka, S., Tanaka, Y., et al. (2010) · Journal of Echocardiography · doi:10.1007/s12574-010-0035-z · Cited by 5
Contact lens opacity grading system (CLOGS)
Hurst, M., Mitchell, S. E., & Douthwaite, W. A. (1994) · Journal of The British Contact Lens Association · doi:10.1016/s0141-7037(94)80013-8 · Cited by 4
Which equation should be used to measure energy expenditure in HIV-infected patients?
Vassimon, H. S., Monteiro, J. P., Machado, A. A., de Paula, F. J. A., Kutschenko, A., & Jordão, A. A. (2013) · Revista de Nutrição · doi:10.1590/s1415-52732013000200010 · Cited by 4
Aoki, M., Harada, K., & Takada, G. (2003) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.199.211 · Cited by 4
MEASUREMENTS OF RESPIRATORY CAPACITY IN PATIENTS WITH NEUROMUSCULAR DISEASES
Balantič, Z., & Zupan, A. (2003) · Experimental Lung Research · doi:10.1080/01902140390240177 · Cited by 4
Evaluation of the iChem® Velocity™ Urine Chemistry Analyzer in a hospital routine laboratory
Hoffmann, P., Hoffmann, C., Ziebig, R., & Zimmermann, M. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.065 · Cited by 4
A new strategy for CD4 T-cell monitoring of HIV-positive patients at remote facilities in Cambodia
Pean, P., Vong, S., Kato, M., Leng, V. S., Mean, C. V., Sarthou, J. L., & Badrichani, A. Z. (2005) · AIDS · doi:10.1097/01.aids.0000196123.68762.ee · Cited by 4
Høyer, C., Aagaard, S. R., Pedersen, T. F., Andersen, N. T., Hasenkam, J. M., & Sloth, E. (2007) · Echocardiography · doi:10.1111/j.1540-8175.2007.00498.x · Cited by 4
Li, Z. Y., Yan, C. L., Yan, R., & Feng, Z. (2010) · Transplantation Proceedings · doi:10.1016/j.transproceed.2010.09.155 · Cited by 4
Contusion pulmonaire : intérêt de l’évaluation du volume pulmonaire lésé en tomodensitométrie
Christin, F., Meyer, N., Launoy, A., Roedlich, M. N., Diebolt, J. R., Veillon, F., & Pottecher, T. (2003) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/s0750-7658(03)00130-8 · Cited by 4
Svendsen, A. J., Holmskov, U., Petersen, P. H., & Jensenius, J. C. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(94)00258-x · Cited by 4
Evaluation of corneal nerves morphology for diabetic peripheral neuropathy assessment
Silva, S. F., Loureiro, C., Almeida, H., Otel, I., Domingues, J. P., Silva, J. S., Quadrado, M. J., & Morgado, M. (2012) · IEEE Portuguese Meeting on Bioengineering · doi:10.1109/enbeng.2012.6331376 · Cited by 4
Dencker, M., Thorsson, O., & Wollmer, P. (2005) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2005.00612.x · Cited by 4
Yang, X., Zhen, L., Pan, M., Han, J., Li, D., & Liao, C. (2014) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2014.885944 · Cited by 4
Widmer, A., & Hu, Y. (2010) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2010.5575211 · Cited by 4
Baulig, W., Schuett, P., Gödje, O. L., & Schmid, E. R. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9068-x · Cited by 4
Fukuda, S., Hozumi, T., Watanabe, H., Muro, T., Abo, K., Yoshiyama, M., Takeuchi, K., & Yoshikawa, J. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00471-5 · Cited by 4
Psychosocial and environmental distress resulting from a volcanic eruption: Study protocol
Warsini, S., Usher, K. J., Buettner, P. G., Mills, J. E., West, C., & Methods, R. (2014) · Collegian Journal of the Royal College of Nursing Australia · doi:10.1016/j.colegn.2014.03.004 · Cited by 5
Comparative Study of Values of Calculated Bicarbonate and Measured Total Carbon Dioxide Content
Lolekha, P. H., Boonlert, W., Kost, G. J., Vanavanan, S., & Lolekha, S. (2003) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/00134384-200306000-00011 · Cited by 4
Kaczmarek, E., Banasiewicz, T., Seraszek‐Jaros, A., Krokowicz, P., Grochowalski, M., Majewski, P., Żurawski, J., Paszkowski, J., & Drews, M. (2013) · Pathology - Research and Practice · doi:10.1016/j.prp.2013.11.007 · Cited by 4
RECall for Automated Genotypic Tropism Testing
Pou, C., Bellido, R., Casadellà, M., Puig, T., Clotet, B., Harrigan, R., & Paredes, R. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.00935-13 · Cited by 4
Urinary calcium excretion in enterally fed disabled children
Shetty, A. K., Carlin, J. B., & Zulf Mughal, M. (2001) · Archives of Disease in Childhood · doi:10.1136/adc.85.1.58 · Cited by 4
Bossé, D., Walti, H., Robert, R., Lebon, J. A. J. M., Lesur, O., Praud, J.-P., & Micheau, P. (2010) · ASAIO Journal · doi:10.1097/mat.0b013e3181f1cd72 · Cited by 4
Hung, Y.-C., Bauer, J. D., Horsely, P., Ward, L. C., Bashford, J., & Isenring, E. A. (2014) · Nutrition · doi:10.1016/j.nut.2014.01.017 · Cited by 4
Tio, R. A., Monnink, S. H. J., Jessurun, G. A. J., Peels, J. O. J., van Boven, A. J., van Gilst, W. H., & Crijns, H. J. G. M. (1999) · International Journal of Cardiology · doi:10.1016/s0167-5273(99)00094-7 · Cited by 4
Wang, C., Chen, W., Ho, W., Hsu, L., Cheng, N., Hsu, T., Luqman, N., & Kuo, C.-T. (2006) · Cited by 4
Extrinsic multiecho phase-contrast SSFP: evaluation on cardiac output measurements
Rolf, M. P., Hofman, M. B. M., Kuijer, J. P. A., Pai, V. M., Greiser, A., van Rossum, A. C., & Heethaar, R. M. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.07.006 · Cited by 4
Hydration abnormalities in Nigerian patients on chronic hemodialysis
Tzamaloukas, A. H., Onime, A., Agaba, E. I., VanderJagt, D. J., Irene, M. A., Lopez, A., Tzamaloukas, R. A., & Glew, R. H. (2007) · Hemodialysis International · doi:10.1111/j.1542-4758.2007.00225.x · Cited by 4
Qin, J., Wang, J., Lü, W., Li, Y., Yao, W., & Qian, Y. (2010) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2010.29.12.1801 · Cited by 4
Supra-maximal verification of peak oxygen uptake in adolescents with cystic fibrosis
Werkman, M. S., Hulzebos, E. H. J., Leeuwen, P. V. D. W.-V., Arets, B. G. M., Helders, P. J. M., & Takken, T. (2010) · Journal of Cystic Fibrosis · doi:10.1016/s1569-1993(10)60261-5 · Cited by 4
Estimation of Septal Wall Thickness by Processing Sequential Echocardiographic Images
Mouladous, H., Mokhtari‐Dizaji, M., & Haghighi, S. Z. O. (2009) · Cited by 4
Boneth-Collante, M. D. C., García, C. L. A., Fonseca, A. A., Patiño, J. P., Monsalve, A., & Gómez, E. (2012) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 7
de Groot, S., Bevers, G., Dallmeijer, A. J., Post, M. W. M., van Kuppevelt, H., & van der Woude, L. H. V. (2009) · Clinical Rehabilitation · doi:10.1177/0269215509343248 · Cited by 4
Grothues, F., Bönigk, H., Ghanem, A., Schwerdtfeger, A., Bartels, D., Alpers, S., Tempelmann, C., & Klein, H. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600897328 · Cited by 4
Ineffectiveness of using the pressure relief valve technique during cuff inflation
Annoni, R., & Pires-Neto, R. C. (2014) · Revista Brasileira de Terapia Intensiva · doi:10.5935/0103-507x.20140056 · Cited by 4
Yu, B. S. Y., & Lam, A. K. C. (2007) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2006.00463.x · Cited by 4
Rosa, F. W., Camelier, A. A., Mayer, A. F., & Jardim, J. R. (2006) · Archivos de Bronconeumología · doi:10.1016/s1579-2129(06)60543-0 · Cited by 4
Mauger, A. R., Huntley, T. D., & Fletcher, I. M. (2014) · Perceptual and Motor Skills · doi:10.2466/27.06.pms.118k19w7 · Cited by 4
Technique of color Doppler quantification of vascularity in transplanted kidneys
Gruenewald, S. M., Skerrett, D., Dolimier, D., & Nankivell, B. J. (2002) · Journal of Clinical Ultrasound · doi:10.1002/jcu.10044 · Cited by 4
Observer variation in the assessment of resin composite
Tobi, H., Groen, H. J., Kreulen, C. M., & van Amerongen, W. E. (1998) · Dental Materials · doi:10.1016/s0109-5641(98)00002-5 · Cited by 4
Brokelman, R. B. G., van Loon, C. J. M., & Boog, G. J. T. M. (2006) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-006-0272-9 · Cited by 4
Evaluation of a bar-code system for nutrient analysis in dietary surveys
Anderson, A. S., Maher, L., Ha, T., Cooney, J., Eley, S., Martin, M. M., Vespasiani, G., Bruni, M., & Lean, M. E. J. (1999) · Public Health Nutrition · doi:10.1017/s1368980099000774 · Cited by 4
MRI for diagnosing aortic valve stenosis: a comparison study of MRI and ultrasound.
van Pul, C., de Jong, N. M. C. M., Beek, V. L., Pasmans, H., Wijn, P. P., & Visser, R. (2005) · PubMed Central · Cited by 4
Pace, L., Betocchi, S., Franculli, F., Piscione, F., Ciarmiello, A., Sullo, P., Chiariello, M., & Salvatore, M. (1994) · PubMed · Cited by 4
A semiautomatic method to identify vertebral end plate lesions (Schmorl's nodes)
Newell, N., Grant, C. A., Izatt, M. T., Little, J. P., Pearcy, M. J., & Adam, C. J. (2015) · The Spine Journal · doi:10.1016/j.spinee.2015.04.027 · Cited by 4
Escala de depresión preescolar para maestros (ESDM 3-6) :
Llaberia, E. D., Araneda, N., Xifró, A., & Riba, M. D. (2003) · Psicothema · Cited by 11
Blasi, R. A. D., & Arcioni, R. (2014) · Microcirculation · doi:10.1111/micc.12139 · Cited by 4
Rising, R. (2011) · Nutrition Journal · doi:10.1186/1475-2891-10-14 · Cited by 4
A Sequence Based Validation of Gene Expression Microarray Data
Thallinger, G. (2012) · Current Research in Bioinformatics · doi:10.3844/ajbsp.2012.1.9 · Cited by 4
In Vivo Capillary Loop Hemoglobin Spectroscopy in Labial, Sublingual, and Periodontal Tissues
Townsend, D., D’Aiuto, F., & Deanfield, J. E. (2015) · Microcirculation · doi:10.1111/micc.12218 · Cited by 4
Accuracy of bedside glucometry in critically ill children with peripheral hypoperfusion
Khositseth, A., Pharadornuwat, O., Lertbunrian, R., Anantasit, N., & Vaewpanich, J. (2014) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9579-1 · Cited by 4
Quantification of right and left ventricular function with real-time three-dimensional ultrasound
Angelini, E. D., Laine, A. F., Donis, J., Gersony, D. R., & Homma, S. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1017310 · Cited by 4
Earle, V. L., Ross, F., Fisher, A., Strike, P. W., Berrington, S., Chiecchio, L., Cabanas, E. D., Washbourne, R., Watts, K., & Grand, F. (2007) · Genes Chromosomes and Cancer · doi:10.1002/gcc.20450 · Cited by 4
Zwink, T. R., Burwash, I. G., Miyake-Hull, C. Y., & Otto, C. M. (1994) · Journal of diagnostic medical sonography · doi:10.1177/875647939401000504 · Cited by 4
Watson, M., Bibbo, D., Duffy, C. R., Riches, P. E., Conforto, S., & Macaluso, A. (2014) · Journal of Applied Biomechanics · doi:10.1123/jab.2013-0317 · Cited by 4
Hip muscle strength and function in very elderly women
Smith, R., Scott, O. M., Skelton, D. A., & Young, A. (1996) · Clinical Rehabilitation · doi:10.1177/026921559601000410 · Cited by 4
Reliability and Validity of the Body Caliper to Evaluate Body Composition
Stalker, G. L. (2020) · Digital Scholarship - UNLV (University of Nevada Reno) · doi:10.34917/4332614 · Cited by 4
Fuller, H. D. (2006) · Congestive Heart Failure · doi:10.1111/j.1527-5299.2006.05755.x · Cited by 4
Sun, Y., Jiang, T., Zeng, Z., & Chen, P. (2009) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfp685 · Cited by 4
de Vries, J. H. M., & de Boer, E. J. (2015) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-1075-3_2 · Cited by 4
The discrepancy hypothesis in children with language disorders: Does it work?
Keegstra, A. L., Post, W. J., & Goorhuis-Brouwer, S. M. (2009) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2009.11.005 · Cited by 4
Gillespie, D. C., Bowen, A., & Foster, J. K. (2012) · Applied Neuropsychology Adult · doi:10.1080/09084282.2011.643937 · Cited by 5
Kisch-Wedel, H., Bernreuter, P., Kemming, G., Albert, M., & Zwißler, B. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2019629 · Cited by 4
"Three-Year Reproducibility of Natural Head Position; A Longitudinal Study "
Nouri, M., Mir, M., Akbarzadeh, A., & Marami, A. (2006) · Cited by 4
Boosting BOLD fMRI by K-Space Density Weighted Echo Planar Imaging
Zeller, M., Müller, A., Gutberlet, M., Nichols, T. E., Hahn, D., Köstler, H., & Bartsch, A. J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0074501 · Cited by 6
Can the Northwick Park Dependency Scale be translated to a Barthel Index?
Turner‐Stokes, L. F., Williams, H., Howley, D., & Jackson, D. M. (2010) · Clinical Rehabilitation · doi:10.1177/0269215510371432 · Cited by 4
Does display sensitivity influence motor latency determination?
Takahashi, N., & Robinson, L. R. (2009) · Muscle & Nerve · doi:10.1002/mus.21498 · Cited by 4
A comparison between two exercise tests on cycle; a computerized test versus the Åstrand test
Wisén, A. G. M., & Wohlfart, B. (1995) · Clinical Physiology · doi:10.1111/j.1475-097x.1995.tb00433.x · Cited by 4
Repeatability and Reliability of a New Phoria Test Using Flashed and Auto-flashed Presentation
Moon, B.-Y., Park, S.-Y., & Cho, H. G. (2012) · Journal of the Optical Society of Korea · doi:10.3807/josk.2012.16.4.418 · Cited by 4
Flow cytometric analysis of leukocytes and reticulocytes stained with proflavine.
Sagawa, H., & Tatsumi, N. (1997) · PubMed · Cited by 4
Gentles, T. L., Neutze, J. M., Caulder, A. L., & Greene, E. R. (2001) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2001.20.4.365 · Cited by 4
Gupta, A. K., & Cooper, E. (2012) · Journal of Dermatological Treatment · doi:10.3109/09546634.2012.697990 · Cited by 4
Ambrisko, T. D., & Klide, A. M. (2011) · American Journal of Veterinary Research · doi:10.2460/ajvr.72.10.1299 · Cited by 4
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.