STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 37,601–37,700 of 47,868
Hokken, R. B. (1998) · European Heart Journal · doi:10.1053/euhj.1997.0745 · Cited by 4
Machado, F. A., & Denadai, B. S. (2013) · Motriz Revista de Educação Física · doi:10.1590/s1980-65742013000100012 · Cited by 14
Urine Collection From Disposable Diapers in Premature Infants: Biochemical Analysis
Muratore, C. S., & Dhanireddy, R. (1993) · Clinical Pediatrics · doi:10.1177/000992289303200516 · Cited by 4
Between‐day reliability of the trapezius muscle H‐reflex and M‐wave
Vangsgaard, S., Hansen, E. A., & Madeleine, P. (2015) · Muscle & Nerve · doi:10.1002/mus.24645 · Cited by 4
Alston, R. P., Glassford, N. J., & Torrie, A. (2003) · Perfusion · doi:10.1191/0267659103pf695oa · Cited by 4
Thromboelastometry, a Possible Tool to Identify Women at Risk of Pregnancy Loss
Papa, M. L., Capasso, F., Alonso-Torre, S. R., Froncillo, G., Russo, V., Pudore, L., Cavaliere, E., Papa, R. R., Muzy, M., Cerasuolo, L., et al. (2009) · The Open Atherosclerosis & Thrombosis Journal · Cited by 4
Reliability of the general severity scoring systems, APACHE II and SAPS II
Capuzzo, M., Pavoni, V., Valpondi, V., Paparella, L., Sgarbi, A., Cingolani, E., Alvisi, R., & Gritti, G. (1998) · Clinical Intensive Care · doi:10.1080/714029051 · Cited by 4
A novel method for the performance of isometric exercise in the home
Wiles, J. D., Coleman, D. A., Dunford, M., & Swaine, I. (2005) · Journal of Sports Sciences · doi:10.1080/02640410400021658 · Cited by 4
Treatment of Canine Lymphoma as a Model for Humans
Bocci, A. G. G. (2015) · Clinical and Experimental Pharmacology · doi:10.4172/2161-1459.1000e120 · Cited by 4
Maeda, T., Sakurai, R., Nakagawa, K., Morishima, K., Maekawa, M., Furumoto, K., Kono, T., Egawa, A., Kubota, Y., Kato, S., et al. (2015) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2015.09.013 · Cited by 5
Peeters, M., Goris, M., Keustermans, G., Pelgrim, K., & Claessens, A. (2011) · European Journal of Sport Science · doi:10.1080/17461391.2011.606836 · Cited by 4
Vibration response imaging versus perfusion scan in lung cancer surgery evaluation
Marina, N., Rodríguez-Trigo, G., Jiménez, U., Morales, B., María, E. L. D. S., Pijoán, J. I., & Gáldiz, J. B. (2013) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2013.08.066 · Cited by 4
Amoozgar, H., Soltani, M., Borzoee, M., Ajami, G., & Cheriki, S. (2011) · Iranian cardiovascular research journal · doi:10.5812/icrj.3957 · Cited by 4
Spriggs, F. P., Aggarwal, P., Deng, S., Soderstrom, C. I., & Donovan, C. B. (2011) · Bioanalysis · doi:10.4155/bio.11.26 · Cited by 4
Novak–Jankovič, V., Paver-Eržen, V., Fajdiga, I., Bovill, J. G., Manohin, A., & Žargi, M. (1998) · European Journal of Anaesthesiology · doi:10.1046/j.1365-2346.1998.00208.x · Cited by 4
Wu, C., Lin, C., Lu, H., Lu, T., & Yeh, L. (2014) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237214500768 · Cited by 4
Peritoneal Transport Kinetics of Proteins in Children on Chronic Peritoneal Dialysis
Arbeiter, K., Stemberger, R., Greenbaum, L., Mueller, T., Konstantin, A. A., Herkner, K. R., & Aufricht, C. (2003) · Peritoneal Dialysis International · doi:10.1177/089686080302300212 · Cited by 4
Teresińska, A., Wnuk, J., Konieczna, S., & Dabrowski, A. A. (2005) · PubMed · Cited by 4
Narančić, N. S., Miličić, J., Tomas, Ž., Petranović, M. Z., Škarić‐Jurić, T., & Tomek-Roksandić, S. (2013) · Hrčak Portal of scientific journals of Croatia (University Computing Centre) · Cited by 4
Hofland, J., Tenbrinck, R., & ERDMANN, W. (2003) · Advances in experimental medicine and biology · doi:10.1007/978-1-4757-6125-2_43 · Cited by 4
Rathod, N., Nair, S. C., Mammen, J., & Singh, S. (2015) · International Journal of Medical Science and Public Health · doi:10.5455/ijmsph.2016.13112015254 · Cited by 4
de Carvalho, N. L., Gonçalves, J. L., Botaro, B. G., Silva, L. F. P. E., & dos Santos, M. V. (2015) · Current Microbiology · doi:10.1007/s00284-015-0855-1 · Cited by 4
van der Slegt, J., Verbogt, N., Mulder, P. G. H., Steunenberg, S. L., Steunenberg, B. E., & van der Laan, L. (2016) · Vascular · doi:10.1177/1708538115625379 · Cited by 4
Hansen, M. L., Fallentin, E., Axelsen, T., Lauridsen, C. A., Norling, R., Svendsen, L. B., & Nielsen, M. B. (2016) · Diagnostics · doi:10.3390/diagnostics6010008 · Cited by 4
Malatino, L., & Brown, W. C. (1988) · Clinical and Experimental Hypertension · doi:10.3109/10641968809033911 · Cited by 4
Lee, I., Sheu, W. H., & Lin, S. (2016) · Medicine · doi:10.1097/md.0000000000002804 · Cited by 5
Radiographic measurement of the posterior femoral offset is not precise
Jenny, J., Honecker, S., & Chammai, Y. (2015) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-015-3855-6 · Cited by 4
First Principles of Instrument Calibration
Workman, J. (2016) · NIR news · doi:10.1255/nirn.1601 · Cited by 4
Cavanaugh, J. T., Dunfey, J. C., & Wyand, M. K. (2014) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3182abe7c0 · Cited by 4
Assessing agreement between CD34 enumeration by flow cytometry and volumetric analysis
Gisselø, C., Roer, O., Hoffmann, M., Hansen, M., Taaning, E., & Johnsen, H. E. (2002) · Bone Marrow Transplantation · doi:10.1038/sj.bmt.1703514 · Cited by 4
Mesure de la fonction rénale par les méthodes radio-isotopiques
Durand, E., Chaumet‐Riffaud, P., Archambaud, F., Moati, F., & Prigent, A. (2006) · Encyclopédie médico-chirurgicale. Néphrologie · doi:10.1016/s1762-0945(06)75699-6 · Cited by 7
Keevil, B. G., Maylor, P. W., & Rowlands, D. (1996) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329603300313 · Cited by 4
[Using descriptors during the implementation of Mini-CEX at pediatric residency].
Abadie, Y., Battolla, J., Zubieta, A., Dartiguelongue, J. B., Pascual, C., Elías Costa, C., Vassallo, J. C., & Rodríguez, S. (2015) · PubMed · Cited by 4
Öner, A. O., Aydin, F. A., Demirelli, S., Budak, E. S., Davran, F., Akbas, H. S., Koçak, H., Süleymanlar, G., & Güngör, F. (2014) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000116 · Cited by 4
Novel dietary intake assessment in populations with poor literacy.
Subasinghe, A. K., Thrift, A. G., Evans, R. G., Arabshahi, S., Suresh, O., Kartik, K., Kalyanram, K., & Walker, K. Z. (2016) · PubMed · doi:10.6133/apjcn.2016.25.1.19 · Cited by 6
Curvature Radius Measurements From the Humeral Trochlea in Large Dogs
Alves‐Pimenta, S., Ginja, M., Fernandes, A. M., Melo‐Pinto, P., & Colaço, B. (2016) · The Anatomical Record · doi:10.1002/ar.23366 · Cited by 4
Analysis of central venous pressure (CVP) signals using mathematical methods
Atefvahid, P., Hassani, K., Jafarian, K., Doyle, D. J., & Ahmadi, H. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9882-0 · Cited by 4
SAITO, T. K., Izawa, K. P., & Watanabe, S. (2016) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0577-7 · Cited by 4
Intraindividual Variability and Long-Term Changes of Thermal Quantitative Sensory Testing
Krøigård, T., Sothynathan, I., & Sindrup, S. H. (2015) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000193 · Cited by 4
Applying a kinetic method to an indirect ELISA measuring Ostertagia ostertagi antibodies in milk.
Vanderstichel, R. V., Dohoo, I. R., & Markham, F. (2015) · Europe PMC (PubMed Central) · Cited by 4
Kitthaweesin, K., & Mungsing, W. (2009) · PubMed · Cited by 4
Wilson, D. C., Day, J. M. E., Hamilton, A., McClure, G., & Davies, P. S. W. (1993) · Springer eBooks · doi:10.1007/978-1-4899-1268-8_30 · Cited by 4
A Shack-Hartmann-Based Autorefractor
Beverage, J., & Schwiegerling, J. T. (2006) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20061101-19 · Cited by 4
Do sample preparation techniques affect the relative abundance of Florisphaera profunda?
Lupi, C., Bordiga, M., Sacchi, R., Galinetto, P., Beaufort, L., & Cobianchi, M. (2016) · Marine Micropaleontology · doi:10.1016/j.marmicro.2016.07.007 · Cited by 4
Newell, N., Grant, C. A., Keenan, B. E., Izatt, M. T., Pearcy, M. J., & Adam, C. J. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1520-y · Cited by 4
(2008) · The Internet Journal of Surgery · doi:10.5580/2216 · Cited by 4
Biomedical engineering aspects of neonatal monitoring
Chock, V. Y., Wong, R. J., Hintz, S. R., & Stevenson, D. K. (2011) · Elsevier eBooks · doi:10.1016/b978-0-323-06545-0.00040-6 · Cited by 4
de Luna, M. E. M., Terven, J. R., Raducanu, B., & Salas, J. (2016) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2016.2606594 · Cited by 5
Chen, M., Liao, C., Chen, S., Ding, Q., Zhu, D., Liu, H., Yan, X., & Zhong, J. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1579-5 · Cited by 4
D’Ortenzio, R., Hojjat, S., Vitorino, R., Cantrell, C. G., Lee, L., Feinstein, A., O'Connor, P. W., Carroll, T., & Aviv, R. I. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4939 · Cited by 4
Ansel, T., Nour, A., & Benavente-Pérez, A. (2016) · Europe PMC (PubMed Central) · Cited by 4
Gravity Does Not Affect Accommodative Amplitude
Augousti, A. T., & Pierscionek, B. K. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-19827 · Cited by 4
Fisher, A. L., Greene, H. M., Talmadge, R. J., & Nout‐Lomas, Y. S. (2016) · Comparative Exercise Physiology · doi:10.3920/cep160019 · Cited by 4
Mossoro‐Kpinde, C. D., Bouassa, R. M., Jenabian, M.-A., Wolyec, S. T., Robin, L., Matta, M., Longo, J. D. D., Grésenguet, G., Andréoletti, L., & Bélec, L. (2016) · AIDS Research and Treatment · doi:10.1155/2016/7954810 · Cited by 4
Kyari, F., & Gilbert, C. E. (2016) · Ophthalmic Epidemiology · doi:10.1080/09286586.2016.1254806 · Cited by 4
Automated detection of the choroid boundary within OCT image data using quadratic measure filters
Wagner, M., Scheibe, P., Francke, M., Zimmerling, B., Frey, K., Vogel, M., Luckhaus, S., Wiedemann, P., Kieß, W., & Rauscher, F. G. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.2.025004 · Cited by 4
Signal-to-noise ratio estimation technique for SEM image using linear regression
Yeap, Z. X., Sim, K. S., & Tso, C. P. (2016) · International Conference on Robotics, Automation and Sciences (ICORAS) · doi:10.1109/icoras.2016.7872602 · Cited by 4
DaRonco, S., Dall'Armi, M., Crotti, S., Calandra, E., Traldi, P., Marco, V. D., Buonadonna, A., Corona, G., Giodini, L., Marangon, E., et al. (2017) · Journal of Mass Spectrometry · doi:10.1002/jms.3927 · Cited by 4
Modi, S. S., Yee, R. K., Scholl, D., Stirrat, J., Wong, J. A., Lydell, C. P., Kotha, V. K., Gula, L. J., Skanes, A. C., Leong‐Sit, P., et al. (2017) · International journal of cardiac imaging · doi:10.1007/s10554-017-1120-4 · Cited by 4
Comparing two methods–agreeing to disagree?
Choi, S. W., & Lam, D. M. H. (2017) · Anaesthesia · doi:10.1111/anae.13874 · Cited by 4
Temporal Artery Temperature Measurement in the Neonate
Syrkin-Nikolau, M., Johnson, K., Colaizy, T. T., Schrock, R., & Bell, E. F. (2017) · American Journal of Perinatology · doi:10.1055/s-0037-1601440 · Cited by 4
Kapadia, S. R., Mentias, A. G., Barakat, A. F., Raza, M. Q., Poddar, K. L., Baeza, C. R., Maluenda, G., Navia, J. L., Schoenhagen, P., & Tuzcu, E. M. (2016) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26575 · Cited by 4
Reliability of resting intramuscular fiber conduction velocity evaluation
Methenitis, S. K., Karandreas, N., & Terzis, G. D. (2017) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12908 · Cited by 5
Analysis of Craniofacial Images using Computational Atlases and Deformation Fields
Ólafsdóttir, H., Ersbøll, B. K., & Larsen, R. (2008) · Cited by 4
Quek, J. M. T., Brauer, S., Treleaven, J. M., & Clark, R. A. (2017) · International Journal of Rehabilitation Research · doi:10.1097/mrr.0000000000000237 · Cited by 4
Díaz–González, C. D. L. M. (2014) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2014/8874.4763 · Cited by 4
Koziej, M., Trybus, M., Mydłowska, A., Piątek, K., Banach, M. D., & Holda, M. K. (2017) · Journal of Hand Therapy · doi:10.1016/j.jht.2017.08.004 · Cited by 4
Kharroubi, S. A. (2017) · Health and Quality of Life Outcomes · doi:10.1186/s12955-017-0770-1 · Cited by 4
Langlois, B. K., Suri, D. J., Wilner, L. B., Walton, S. M., Chui, K. H. K., Caiafa, K. R., & Rogers, B. L. (2017) · Journal of Hunger & Environmental Nutrition · doi:10.1080/19320248.2017.1374902 · Cited by 4
Nkoulou, R. N., Wolfrum, M., Pazhenkottil, A. P., Fiechter, M., Buechel, R. R., Gaemperli, O., & Kaufmann, P. A. (2018) · Journal of Nuclear Cardiology · doi:10.1007/s12350-018-1187-x · Cited by 4
Reproducibility of estimated optimal peak output using a force-velocity test on a cycle ergometer
Coelho-e-Silva, M. J., Rebelo‐Gonçalves, R., Martinho, D. V., Ahmed, A., Luz, L. G. D. O., Duarte, J. P., Severino, V., Baptista, R., Valente‐dos‐Santos, J., Vaz, V., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193234 · Cited by 7
Reliability of Sagittal Spinopelvic Alignment Measurements After Total Hip Arthroplasty
Pernaa, K. I., Seppänen, M., Mäkelä, K. T., & Saltychev, M. (2017) · Clinical Spine Surgery A Spine Publication · doi:10.1097/bsd.0000000000000491 · Cited by 4
Importance of software version for measurement of arterial stiffness: Arteriograph as an example
Ring, M., Eriksson, M. J., Nyberg, G. F., & Caidahl, K. (2018) · PLoS ONE · doi:10.1371/journal.pone.0197019 · Cited by 5
Hurry, J. K., Rehan, S., Spurway, A. J., Laende, E. K., Wilson, J. L. A., Logan, K. J., Dunbar, M., & El‐Hawary, R. (2018) · Journal of Pediatric Orthopaedics B · doi:10.1097/bpb.0000000000000516 · Cited by 4
Almeida, G. J., Terhorst, L. A., James, J. A., Irrgan, G., Fitzgerald, G. K., Jakicic, J. M., & Piva, S. R. (2017) · Journal of Exercise Sports & Orthopedics · doi:10.15226/2374-6904/4/3/00164 · Cited by 5
Xu, L., Jiao, Z., Liu, F., Qiu, X., Ji, L., & Zhang, M. (2018) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000533 · Cited by 4
Fu, Y., Yu, X., Savini, G., Huang, J., Lian, H., Song, B., Wang, Q., & Zhao, Y. (2018) · Current Eye Research · doi:10.1080/02713683.2018.1488264 · Cited by 4
Reliability of the skin blotting method when used on the elderly
Koyano, Y., Nakagami, G., Minematsu, T., & Sanada, H. (2018) · International Wound Journal · doi:10.1111/iwj.12931 · Cited by 4
Snarr, R. L., Tolusso, D. V., Hallmark, A. V., & Esco, M. R. (2018) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002721 · Cited by 8
van Dijk, L. J. D., van der Wel, T., van Noord, D., Moelker, A. D., Verhagen, H. J. M., Nieboer, D., Kuipers, E. J., & Bruno, M. J. (2018) · Expert Review of Medical Devices · doi:10.1080/17434440.2018.1496818 · Cited by 5
Tokutake, K., Iwatsuki, K., Tatebe, M., Okui, N., Mizuno, M., & Hirata, H. (2018) · Journal of Orthopaedic Science · doi:10.1016/j.jos.2018.08.021 · Cited by 4
Watanabe, N., Murakami, S., Uchida, S., Tateishi, S., Ohara, H., Yamamoto, Y., & Kojima, T. (2018) · Journal of Orthopaedic Science · doi:10.1016/j.jos.2018.10.013 · Cited by 4
Urner, L. M., Kohler, M., & Bloch, K. E. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2018.01814 · Cited by 5
Wolfs, J. A. G. N., Bijkerk, E., Schols, R. M., Keuter, X. H. A., van der Hulst, R. R. W. J., & Qiu, S. S. (2019) · Lymphatic Research and Biology · doi:10.1089/lrb.2018.0037 · Cited by 4
Liu, W., Zhang, P., Zhao, X., Sang, M., Liu, X., Liu, L., Liu, S., Lin, H., & Sang, Z. (2019) · Journal of the American College of Nutrition · doi:10.1080/07315724.2019.1568324 · Cited by 4
Reproducibility of river water quality measurements: inter‐agency comparisons for quality assurance
Davies‐Colley, R. J., Milne, J. R., & Heath, M. W. (2019) · New Zealand Journal of Marine and Freshwater Research · doi:10.1080/00288330.2019.1585886 · Cited by 4
Casado‐Hernández, I., Vallejo, R., Losa‐Iglesias, M. E., López‐López, D., Rodríguez‐Sanz, D., Martínez‐Jiménez, E. M., & Calvo‐Lobo, C. (2019) · Sensors · doi:10.3390/s19102249 · Cited by 4
Korhonen, L., Pokka, T. M.-L., Holappa, A., Serlo, W. S., & Sinikumpu, J. (2019) · Scandinavian Journal of Surgery · doi:10.1177/1457496919857261 · Cited by 4
Nagatani, Y., Guipieri, S., Nguyen, V., Chappard, C., Geiger, D., Naı̈li, S., & Haïat, G. (2017) · Ultrasonic Imaging · doi:10.1177/0161734617698648 · Cited by 4
Jesus, F., Nunes, C. L., Matias, C. N., Francisco, R., Carapeto, B., Macias, H., Müller, D., Cardoso, M. G., Valamatos, M. J., Rosa, G. B., et al. (2020) · European Journal of Sport Science · doi:10.1080/17461391.2019.1708974 · Cited by 6
Yamin, G., Cheecharoen, P., Goel, G., Sung, A., Li, C. Q., Chang, Y. A., McDonald, C. R., & Farid, N. (2019) · British Journal of Radiology · doi:10.1259/bjr.20190398 · Cited by 4
Cantürk, M., Kocaoğlu, N., & Hakkı, M. (2020) · Türk anesteziyoloji ve reanimasyon derneği dergisi · doi:10.5152/tjar.2019.92342 · Cited by 4
Reliability of the five factor wellness inventory among male adolescents
Rachele, J. N., Cuddihy, T. F., Washington, T. L., & McPhail, S. (2013) · QUT ePrints (Queensland University of Technology) · Cited by 4
Does size matter? Perineometer and digital examination of a model levator hiatus
Tailor, V. K., Bhide, A., Fernando, R., Digesu, G. A., & Khullar, V. (2020) · Neurourology and Urodynamics · doi:10.1002/nau.24384 · Cited by 4
Effect of Aloe resin on cell migration between Scratch and Boyden chamber assays
Korsuwannawong, S., Srichan, R., & Vajrabhaya, L.-O. (2020) · Journal of Medicinal Plants Research · doi:10.5897/jmpr2020.6981 · Cited by 4
Gianesin, B., Pinto, V. M., Casale, M., Corti, P. C., Fidone, C., Quintino, S., Voi, V., & Forni, G. L. (2020) · Annals of Hematology · doi:10.1007/s00277-020-04188-y · Cited by 5
Comparison of paediatric weight estimation methods at a tertiary hospital in Ghana
Yakubu, R. C., Nguah, S. B., & Ayi-bisah, N. (2021) · African Journal of Emergency Medicine · doi:10.1016/j.afjem.2021.03.005 · Cited by 4
AL-Ghamdi, N. S., & Shaheen, A. A. M. (2021) · Journal of Back and Musculoskeletal Rehabilitation · doi:10.3233/bmr-200240 · Cited by 5
Lewis, D. G., Roncaroli, F., Kearney, T., Coope, D. J., & Gnanalingham, K. K. (2021) · Neuroendocrinology · doi:10.1159/000516823 · Cited by 5
An Efficient Method for Aneurysm Volume Quantification Applicable in Any Shape and Modalities
Chung, J., & Ko, J. H. (2021) · Journal of Korean Neurosurgical Society · doi:10.3340/jkns.2020.0255 · Cited by 4
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.