STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 38,201–38,300 of 47,868
Westhoff, M., Herth, F. J. F., Albert, M., Dienemann, H., & Eberhardt, R. (2012) · American Journal of Clinical Oncology · doi:10.1097/coc.0b013e3182467fdc · Cited by 3
Smith, R., Brook, A. H., & Karmo, M. (2009) · The Open Dentistry Journal · doi:10.2174/1874210600903010167 · Cited by 3
Testing the stereoscopic precision of a large‐format digital camera
Arias-Pérez, B., & Gómez‐Lahoz, J. (2009) · The Photogrammetric Record · doi:10.1111/j.1477-9730.2009.00530.x · Cited by 3
Monitoring of C0 and C2 Blood Concentrations of Cyclosporine on the Roche Hitachi 902 Analyzer
Yargui, L., & Berhoune, A. (2009) · Transplantation Proceedings · doi:10.1016/j.transproceed.2009.06.204 · Cited by 3
Meyer, C., Bonnemains, L., Marçon, F., Marie, P., Felblinger, J., & Vuissoz, P. (2013) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-013-0405-4 · Cited by 6
Giordano, M., Vonken, E.-J. P. A., Bertram, M., Mali, W. P. T. M., Viergever, M. A., & Neukirchen, C. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/22/7239 · Cited by 3
An evaluation method for real-time soft-tissue model used for multi-vertex palpation
Widmer, A., & Hu, Y. (2011) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2011.6083654 · Cited by 3
Different injection techniques in the assessment of central haemodynamics in patients with cirrhosis
Christensen, T. N., Mortensen, C., Henriksen, J. H., & Møller, S. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2012.734395 · Cited by 3
González-Cánovas, C., Muñoz‐Esparza, C., Oliva, M. J., González‐Carrillo, J., López‐Cuenca, Á., Saura, D., García‐Navarro, M., Espinosa, M. D., Martínez, C. C., Caballero, L., et al. (2012) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2012.08.010 · Cited by 6
Renkawitz, T. F., Gneiting, S., Schaumburger, J., Woerner, M. L., Springorum, H.-R., Grifka, J. K., Schuster, T., & Sendtner, E. (2010) · Orthopedics · doi:10.3928/01477447-20100225-10 · Cited by 3
Xiao, H., Zhang, Y., Du, X., & Lu, Z. (2010) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2010.05399.x · Cited by 3
Farrell, S. M. J., Dooley, I. J., O’Connell, E., Bashir, M. S., Foley-Nolan, A., Kearns, F., Logan, P., & Fulcher, T. (2013) · International Ophthalmology · doi:10.1007/s10792-012-9711-5 · Cited by 3
Naßenstein, K., Orzada, S., Haering, L., Czylwik, A., Jensen, C. J., Schlosser, T. W., Bruder, O., Ladd, M. E., & Maderwald, S. (2012) · European Radiology · doi:10.1007/s00330-012-2547-6 · Cited by 5
van Dijk, W. D., Cremers, R., Klerx, W. N. M., Schermer, T. R., & Scheepers, P. T. J. (2012) · Current Analytical Chemistry · doi:10.2174/157341112801264897 · Cited by 3
A new model for the determination of limb segment mass in children
Kuemmerle-Deschner, J. B., Hansmann, S., Rapp, H., & Dannecker, G. E. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2006.06.014 · Cited by 3
Self, S., Allen, J., & Oxborough, D. (2010) · Ultrasound · doi:10.1258/ult.2010.009001 · Cited by 3
Carlisle, J. B. (2013) · Anaesthesia · doi:10.1111/anae.12343 · Cited by 3
Accuracy of Stop-Cursor Method for Determining Systolic and Pulse Pressure Variation
Tyler, L., Greco, S. A., Bridges, E. J., Barnes, S., Brown, L., Green, K. G., & Wolfson, D. (2013) · American Journal of Critical Care · doi:10.4037/ajcc2013295 · Cited by 3
Can self-reported height and weight be used among people living with HIV/AIDS?
Duran, A. C., Florindo, A. A., & Jaime, P. C. (2012) · International Journal of STD & AIDS · doi:10.1258/ijsa.2009.009344 · Cited by 4
Monothermal air caloric test in children
Melagrana, A., D’Agostino, R., Tarantino, V., Taborelli, G., & Calevo, M. G. (2002) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/s0165-5876(01)00571-7 · Cited by 3
[Comparative analysis of parasite detection methods in vegetables for human consumption].
Barnabé, A. S., Ferraz, R. R. N., Pincinato, E. D. C., Gomes, R. C. F., Galleguillos, T. G. B., Cerqueira, M. Z., Soares, E. G. L., Lage, P. S., Araújo, C. X., Szamszoryk, M., et al. (2010) · PubMed · Cited by 3
Can we rely on predicted basal metabolic rate in chronic pancreatitis outpatients?
Olesen, S. S., Holst, M., Køhler, M., Drewes, A. M., & Rasmussen, H. H. (2015) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2014.12.003 · Cited by 3
Evaluation of the anterior chamber angle in keratoconus and normal subjects
Nilsson, M., Miller, W., Cerviño, A., Bergmanson, J. P. G., & Brautaset, R. (2015) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2015.03.004 · Cited by 3
Giraud, R., Siegenthaler, N., Morel, D. R., & Bendjelid, K. (2011) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3181f96823 · Cited by 3
Rani, V., Trijsburg, L. E., Brouwer, I. D., & Khetarpaul, N. (2010) · Ecology of Food and Nutrition · doi:10.1080/03670244.2010.491050 · Cited by 3
Influence of temperature on Mean Scattering Spacing estimation of in vitro bovine muscle
Cortela, G. A., von Krüger, M. A., Machado, C. B., Negreira, C., & Pereira, W. C. A. (2011) · Pan American Health Care Exchanges · doi:10.1109/pahce.2011.5871942 · Cited by 3
Goedhals, D., Scott, L. E., Moretti, S., Cooper, M., Opperman, W. J. L., & Rossouw, I. (2012) · Journal of Virological Methods · doi:10.1016/j.jviromet.2012.11.019 · Cited by 3
Ruiz, P. G., & Pérez, M. D. O. (2009) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 3
Pierelli, L., Fioravanti, D., Patti, D., Iudicone, P., Scocchera, R., PANDOLFI, A., & Nuti, M. (2011) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2011.01373.x · Cited by 3
MOTION SENSOR OUTPUTS OF CHILDREN AND ADOLESCENTS WALKING AND RUNNING TO THREE TREADMILL SPEEDS
Chia, M., Wong, P., Balasekaran, G., Tan, S. K., Kunalan, C., & Chiang, J. (2009) · NIE Digital Repository (National Institute of Education, Nanyang Technological University) · Cited by 3
Bonnemains, L., Odille, F., Meyer, C., Hossu, G., Felblinger, J., & Vuissoz, P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0143744 · Cited by 3
Comparative study of DAS 28 ESR and DAS 28 CRP among rheumatoid arthritis patients in India
Das, A., Bhattacharyya, K., & Sarkar, R. N. (2016) · Indian Journal of Rheumatology · doi:10.1016/j.injr.2015.10.006 · Cited by 3
Accuracy of a Blood Glucose Monitoring System
Vanterpool, G. E. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816630330 · Cited by 3
Al‐Bachir, M., & Othman, I. (2016) · The Social Science Journal · doi:10.1016/j.soscij.2016.02.014 · Cited by 3
Comparison of Unit-Level Patient Turnover Measures in Acute Care Hospital Settings
Park, S. H., Dunton, N. E., & Blegen, M. A. (2016) · Research in Nursing & Health · doi:10.1002/nur.21715 · Cited by 3
Phase-Sensitive Dual-Inversion Recovery for Accelerated Carotid Vessel Wall Imaging
Bonanno, G., Brotman, D., & Stuber, M. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000110 · Cited by 3
Ibrahim, W. G., Khouli, R. H. E., Abd‐Elmoniem, K. Z., Matta, J. R., McAreavey, D., & Gharib, A. M. (2014) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000000131 · Cited by 3
Cano, A., Carvajal‐Urueña, I., Vázquez, C. A. D., Gandarillas, I. M., de Rodas, P. M. C., Merino, A. G., & Aurrecoechea, B. D. (2011) · Boletín de Pediatría · Cited by 3
Dreborg, S. K. G., & Basomba, A. (2016) · Immunotherapy Open Access · doi:10.4172/2471-9552.1000109 · Cited by 3
Metzker, M., Shipkova, M., von Ahsen, N., Andag, R., Abe, M., Canzler, O., Klett, C., Leicht, S., Olbricht, C. J., & Wieland, E. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.05.019 · Cited by 3
Tanudjojo, N., Soedigdo, P., & Soedigdo, S. (2002) · Food and Nutrition Bulletin · doi:10.1177/15648265020233s112 · Cited by 3
Motamed, C., Chedevergne, K., Deschamps, F., Tselikas, L., & Jayr, C. (2016) · Anesthesiology and Pain Medicine · doi:10.5812/aapm.37577 · Cited by 3
Zhao, F., Wang, P., Pei, S., Mi, W., & Fu, Q. (2015) · PubMed Central · Cited by 3
Giambene, B., Virgili, G., & Menchini, U. (2016) · European Journal of Ophthalmology · doi:10.5301/ejo.5000822 · Cited by 3
Pedone, C., Berardino, A. D. M., Pistelli, R., Forastiere, F., Bellia, V., & Incalzi, R. A. (2016) · Respiration · doi:10.1159/000447246 · Cited by 3
Right Ventricular Pressure Overload and Pathophysiology of Growing Porcine Biomodel
Kobr, J., Slavík, Z., Uemura, H., Saeed, I., Furck, A., Pizingerová, K., Fremuth, J., & Tonar, Z. (2016) · Pediatric Cardiology · doi:10.1007/s00246-016-1463-y · Cited by 3
Kim, B., Kim, K. W., Kim, S. Y., Park, S. H., Lee, J., Song, G., Jung, D., Ha, T., & Lee, S. (2016) · European Radiology · doi:10.1007/s00330-016-4572-3 · Cited by 3
Radke, O. C., Schneider, T., Braune, A., Pirracchio, R., Fischer, F., & Koch, T. (2016) · Bio-Medical Materials and Engineering · doi:10.3233/bme-161588 · Cited by 3
Nishi, T., Kitahara, H., Fujimoto, Y., Nakayama, T., Sugimoto, K., Nagashima, K., Hanaoka, H., & Kobayashi, Y. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012737 · Cited by 3
Lumen coronary artery border detection using texture and Chi-square classification
Sofian, H., Muhammad, S., Ming, J. T. C., & Noor, N. M. (2015) · International Conference on Image and Vision Computing New Zealand (IVCNZ) · doi:10.1109/ivcnz.2015.7761535 · Cited by 3
Using a worst pain intensity measure in children and adolescents
Avian, A., Messerer, B., Meißner, W., Sandner‐Kiesling, A., Kammel, J., Labugger, M., Weinberg, A., & Berghold, A. (2017) · Journal of Advanced Nursing · doi:10.1111/jan.13271 · Cited by 3
A novel fontanelle probe for sensing oxygen saturation in the neonate
May, J. M., Kyriacou, P. A., & Petros, A. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aa5946 · Cited by 3
Validation of a quantitative method to measure neural respiratory drive in children during sleep
Chuang, S., Teng, A. Y., Butler, J. E., Gandevia, S. C., Selvadurai, H. C., & Jaffé, A. (2017) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2017.02.004 · Cited by 3
Computer-Based Algorithmic Determination of Muscle Movement Onset Using M-Mode Ultrasonography
Tweedell, A. J., Haynes, C. A., & Tenan, M. S. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.12.019 · Cited by 3
Strabismus Measurements in Adults Before and After Pupil Dilation
Rivera, S. S., Lee, M. S., Lunos, S. A., Anderson, J. S., & Bothun, E. D. (2017) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2017.03.004 · Cited by 3
Umezaki, S., Kida, N., & Nomura, T. (2017) · International Journal of Sport and Health Science · doi:10.5432/ijshs.201610 · Cited by 3
Local up-sampling and morphological analysis of low-resolution magnetic resonance images
Natali, M., Tagliafico, G., & Patanè, G. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.096 · Cited by 3
Jeon, C.-H., Kwack, K., Park, S., Lee, H.-D., & Chung, N.-S. (2017) · The Spine Journal · doi:10.1016/j.spinee.2017.07.001 · Cited by 3
Sarmento, R. M. B., & Silvino, Z. R. (2017) · Journal of Clinical Research & Bioethics · doi:10.4172/2155-9627.1000308 · Cited by 3
Liu, J., Jia, X., Jia, S., Qin, X., Zhang, T., Liu, L., Li, H., Rong, D., Zhou, Z., Song, Y., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-12587-x · Cited by 3
Kuetting, D. L. R., Feißt, A., Dabir, D., Luetkens, J. A., Homsi, R., Thomas, D., Schild, H. H., & Sprinkart, A. M. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.02.035 · Cited by 3
Horváth, M., & Csoknyai, T. (2018) · Thermal Science · doi:10.2298/tsci170525120h · Cited by 3
Venkat, B., Sharma, S., Sharma, D. D., Sood, S., Aggarwal, N., Sarkar, M. S., Seam, R. K., Mittal, N., & Rana, L. (2018) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1016/j.ejrnm.2017.12.007 · Cited by 3
Estimation of the Heart Rate Variability Features via Recurrent Neural Networks
Porumb, M., Castaldo, R., & Pecchia, L. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-9035-6_61 · Cited by 3
Rezazadeh, H., Arabalibeik, H., Alipour, F., Pasyar, P., & Sadeghi, V. (2018) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2018.07.002 · Cited by 3
Barboza, M. N. C., Barboza, G. N. C., Colombo-Barboza, L. R., Matuoka, M., Neto, A. L., & de Freitas, D. (2018) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2018.05.008 · Cited by 3
Litschel, R., & Tasman, A. (2018) · Facial Plastic Surgery · doi:10.1055/s-0038-1667025 · Cited by 3
Mannix, C., Rangan, A., Wong, A. T. Y., Zhang, J., Allman-Farinelli, M. A., & Rangan, G. K. (2018) · Nutrients · doi:10.3390/nu10081051 · Cited by 3
Goebel, J., Nensa, F., Schemuth, H. P., Maderwald, S., Schlosser, T. W., Orzada, S., Rietsch, S. H. G., Quick, H. H., & Naßenstein, K. (2018) · European Journal of Radiology Open · doi:10.1016/j.ejro.2018.08.008 · Cited by 3
Novel Algorithms to Monitor Continuous Cardiac Activity with a Video Camera
Lewis, G. F., Davila, M. I., & Porges, S. W. (2018) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2018.00175 · Cited by 3
QuickCount ® : a Novel Automated Software for Rapid Cell Detection and Quantification
Tiong, K. H., Chang, J. K., Pathmanathan, D., Fadlullah, M. Z. H., Yee, P. S., Liew, C. S., Rahman, Z. A. A., Beh, K. L., & Cheong, S. C. (2018) · BioTechniques · doi:10.2144/btn-2018-0072 · Cited by 3
Almeida, I. D. S., Barreto, L. P., Andrade, L. D. S., Sousa, C. V., & Mota, Y. L. (2019) · Brazilian Journal of Kinanthropometry and Human Performance · doi:10.5007/1980-0037.2018v20n6p515 · Cited by 3
Koirala, N., Chauhan, N. R., Thompson, D., Karimloo, Z., Wunderle, K. A., & McLennan, G. (2019) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2018.10.023 · Cited by 3
Hao, G., Liu, Y., Ma, G., Hou, J., Zhu, D., Liu, L., Zhang, Y., Liu, H., Zhuang, Y., Luo, Z., et al. (2019) · Cardiovascular Ultrasound · doi:10.1186/s12947-019-0155-1 · Cited by 3
Extraction of Respiration from PPG Signals Using Hilbert Vibration Decomposition
Sharma, H. K. (2019) · International Conference on Bioscience, Biochemistry and Bioinformatics (ICBBB) · doi:10.1145/3314367.3314369 · Cited by 4
Tepedino, M., Noce, M. V. D., Ciavarella, D., Gallenzi, P., Cordaro, M., & Chimenti, C. (2019) · Minerva Dental and Oral Science · doi:10.23736/s0026-4970.19.04197-9 · Cited by 3
New On-Water Test for the Assessment of Blood Lactate Response to Exercise in Elite Kayakers
Pilotto, A., Rasica, L., SCALISE, G., ANNONI, S., Torre, A. L., Marzorati, M., & Porcelli, S. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002077 · Cited by 6
In-season variation in shoulder strength, movement and pain in elite cricketers: A cohort study
Peckitt, J., & McCaig, S. (2019) · Physiotherapy Practice and Research · doi:10.3233/ppr-190131 · Cited by 5
A Frequency-domain Approach to Noninvasive Intracranial Pressure Estimation
Jaishankar, R., Fanelli, A., Filippidis, A., Vu, T., Holsapple, J. W., & Heldt, T. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857042 · Cited by 3
Földi, S., Horváth, T., Zieger, F., Sótonyi, P., & Cserey, G. (2019) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000407 · Cited by 3
Cytological examination of cerebrospinal fluid: Sysmex UF-1000i versus optical microscopy
Maleb, A., Bouayadi, O., Malki, J. E., Rifai, S., Lamrabat, S., Benaissa, E., Lahlou, Y. B., Frikh, M., & Elouennass, M. (2019) · Analytical Biochemistry · doi:10.1016/j.ab.2019.113501 · Cited by 3
Frothy saliva—A novel indicator to assess stereotypies in sows?
Friedrich, L., Krieter, J., Kemper, N., & Czycholl, I. (2019) · Applied Animal Behaviour Science · doi:10.1016/j.applanim.2019.104897 · Cited by 5
Lee, S.-J., Lim, J. Y., Lee, C.-H., & Park, D.-S. (2019) · Physical therapy rehabilitation science · doi:10.14474/ptrs.2019.8.4.218 · Cited by 3
Feature-tracking-based strain analysis – a comparison of tracking algorithms
Thomas, D., Luetkens, J. A., Faron, A., Dabir, D., Sprinkart, A. M., & Kuetting, D. L. R. (2020) · Polish Journal of Radiology · doi:10.5114/pjr.2020.93610 · Cited by 3
Evaluation of Vibration Analysis to Assess Bone Mineral Density in Children
Razaghi, H., Saatchi, R., Bishop, N. J., Burke, D. P., & Offiah, A. C. (2020) · WSEAS TRANSACTIONS ON BIOLOGY AND BIOMEDICINE · doi:10.37394/23208.2020.17.6 · Cited by 3
Validation of Medicare Rehabilitation Functional Assessments in Routine Care
Kerber, K. A., Skolarus, L. E., Feng, C., & Burke, J. F. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.4702 · Cited by 3
Accuracy of the Hand-held Wavefront Aberrometer in Measurement of Refractive Error
Han, J. Y., Yoon, S., Brown, N. S., Han, J., & Han, J. (2020) · Korean Journal of Ophthalmology · doi:10.3341/kjo.2019.0132 · Cited by 3
Sousa, A. J. D. S., Padilha, J. F., da Silva, J. B., Hirakawa, H. S., Seidel, E. J., & Driusso, P. (2020) · International Urogynecology Journal · doi:10.1007/s00192-020-04381-7 · Cited by 4
The geodetic detection of the variable load impact on the earth-filled structure
Kuraś, P., Ortyl, Ł., Owerko, T., & Borecka, A. (2020) · Applied Geomatics · doi:10.1007/s12518-020-00324-5 · Cited by 3
Takahashi, D., Goto, K., & Goto, K. (2020) · Journal of Perinatology · doi:10.1038/s41372-020-0758-2 · Cited by 3
Gür, D. Ö., Baykız, D., Gür, Ö., Alpsoy, Ş., Akyüz, A., & Gürkan, S. (2020) · International journal of cardiac imaging · doi:10.1007/s10554-020-01978-3 · Cited by 3
Kronborg, M. B., Stephansen, C., Kristensen, J., Gerdes, C., & Nielsen, J. C. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14729 · Cited by 3
Bellenger, C. R., Thomson, R. L., Robertson, E. Y., Davison, K., Nelson, M. J., Karavirta, L., & Buckley, J. D. (2020) · Scientific Reports · doi:10.1038/s41598-020-71597-4 · Cited by 3
Eterović, M., Marinić, L. M., Medved, V., & Bilić, V. (2020) · Current Psychology · doi:10.1007/s12144-020-01084-6 · Cited by 5
Chen, B., Liu, Y., Zuo, W., Li, Q., Kong, D., Pan, C., Dong, L., Shu, X., & Ge, J. (2020) · Cardiovascular Ultrasound · doi:10.1186/s12947-020-00225-y · Cited by 3
Wang, B., Huang, L.-T., Hsieh, M.-L., Wang, C., Wang, J., Kan, C., Wu, J.-M., & Tsai, Y. (2020) · Clinical Imaging · doi:10.1016/j.clinimag.2020.10.027 · Cited by 3
Watts, J. (2020) · Reproduction in Domestic Animals · doi:10.1111/rda.13852 · Cited by 3
A New Alignment and Breakthrough Accuracy Optimization Strategy in Long Immersed Tunnel Surveys
Li, G., Huang, S., Wang, X., Li, C., & Zhang, W. (2020) · IEEE Access · doi:10.1109/access.2020.3046635 · Cited by 3
Is data mining approach a best fit formula for estimation of low-density lipoprotein cholesterol?
Sarangi, R., Bahinipati, J., Pathak, M., & Mahapatra, S. (2021) · Journal of Family Medicine and Primary Care · doi:10.4103/jfmpc.jfmpc_1734_20 · Cited by 3
Comparison of resting metabolic rate prediction equations in college-aged adults
Ducharme, J. B., Fennel, Z. J., Pike, B., Coleman, A., Mermier, C. M., Lauver, J. D., Guilkey, J. P., & Johnson, K. E. (2021) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2020-0887 · Cited by 3
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.