STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 38,101–38,200 of 47,868
Words matter: Effects of instructional cues on pressure pain threshold values in healthy people
Evans, D. W., Mear, E., Neal, B. S., Waterworth, S., & Liew, B. X. W. (2024) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2024.103150 · Cited by 5
Design and development of a feedback system for automatic treadmill speed adaptation
Fruet, D., Zignoli, A., Modena, R., Pellegrini, B., Gastaldi, L., & Bortolan, L. (2024) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/17543371241257996 · Cited by 3
Söderström, E., Sandborg, J., Nilsson, E., Henström, M., Lemming, E. W., Lindroos, A. K., Rood, J., Sipinen, J. P., & Löf, M. (2024) · Nutrition Journal · doi:10.1186/s12937-024-00987-5 · Cited by 4
Lin, X., Zhang, J., Kong, X., Li, Y., Xu, X., Du, L., & Zhang, J. L. (2024) · Physiological Reports · doi:10.14814/phy2.16171 · Cited by 3
Rezaee, R., Maleki, A., Aboubakri, O., Safari, M., Masoodian, S. A., Darand, M., Godini, K., Goudarzi, G., Khosravi, A., & Zarei, M. (2024) · Air Quality Atmosphere & Health · doi:10.1007/s11869-024-01625-z · Cited by 3
Tayebi, S., Wise, R., Zarghami, A., Dąbrowski, W., Malbrain, M. L. N. G., & Stiens, J. H. (2024) · Sensors · doi:10.3390/s24165431 · Cited by 3
Henningsen, M. B., Kristensen, J., Kirkeby, C., & Nielsen, S. S. (2024) · Acta veterinaria Scandinavica · doi:10.1186/s13028-024-00763-9 · Cited by 3
Li, L., Li, Y.-J., Liu, M., & Yu, F.-L. (2024) · Journal Français d Ophtalmologie · doi:10.1016/j.jfo.2024.104080 · Cited by 3
Mula-Pérez, F., Manzano-Sánchez, D., Ríos, L. J. C., Ríos, I. J. C., & Perea, Á. R. (2024) · Applied Sciences · doi:10.3390/app14177778 · Cited by 3
Evaluation of the Garmin Vivofit 4 for assessing sleep in youth experiencing sleep disturbances
Hibbing, P. R., Pilla, M., Birmingham, L., Byrd, A., Ndagijimana, T., Sadeghi, S., Seigfreid, N., Farr, D., Al-Shawwa, B. A., Ingram, D. G., et al. (2024) · Digital Health · doi:10.1177/20552076241277150 · Cited by 6
Baral, R. M., Flatland, B., Jaensch, S. M., Hayward, D. A., & Freeman, K. P. (2024) · Veterinary Clinical Pathology · doi:10.1111/vcp.13376 · Cited by 3
Schipholt, I. J. L., Scholten-Peeters, G. G. M., Logghe, S., Koop, M. A., Donders, S., Stenneberg, M. S., & Coppieters, M. W. (2024) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2024.103191 · Cited by 3
Schnake-Mahl, A. S., Anfuso, G., Hernandez, S. M., & Bilal, U. (2024) · Epidemiology · doi:10.1097/ede.0000000000001797 · Cited by 3
Bancone, G., Gilder, M. E., Win, E., Gornsawun, G., Moo, P. K., Archasuksan, L., Wai, N. S., Win, S., Hanboonkunupakarn, B., Nosten, F. H., et al. (2024) · BMJ Paediatrics Open · doi:10.1136/bmjpo-2024-002754 · Cited by 3
Modified creatinine index as a marker of skeletal muscle mass in peritoneal dialysis patients
Ng, J. K., Fung, W. W., Chan, G. C., Cheng, P. M., Pang, W., Chow, K., & Szeto, C. (2024) · Clinical Kidney Journal · doi:10.1093/ckj/sfae297 · Cited by 3
Reichert, S., Switala, H., & Schulz, S. (2024) · International Dental Journal · doi:10.1016/j.identj.2024.09.021 · Cited by 3
Dietary patterns related to attention and physiological function in high-altitude migrants
Su, R., Zhang, W., Huang, J., Fan, J., Peng, P., Li, H., Zhang, D., Li, Y., Ma, H., Nie, L., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-75313-4 · Cited by 3
Katsumata, Y., Sada, K., Kameda, T., Dobashi, H., Kaname, S., Tsuboi, N., Matsumoto, Y., Amano, K., Tamura, N., Harigai, M., et al. (2024) · Immunological Medicine · doi:10.1080/25785826.2024.2408054 · Cited by 3
Zarei‐Ghanavati, S., Najjaran, M., Hassanzadeh, S., Khabazkhoob, M., Gokul, A., & Ziaei, M. (2024) · Journal of Current Ophthalmology · doi:10.4103/joco.joco_261_23 · Cited by 3
Herrera, G., Cheng, Y., Attiku, Y., Hiya, F. E., Shen, M., Liu, J., Lu, J., Berni, A., Trivizki, O., Li, J., et al. (2024) · Ophthalmology Science · doi:10.1016/j.xops.2024.100633 · Cited by 7
Single Antenna Bio-Sensing for Noninvasive Respiratory and Cardiac Activity Monitoring
Ahadi, M., Miled, A., Dugas, M.-A., & Messaddeq, Y. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3484459 · Cited by 4
Ahlberg, S., Brännström, K. J., Öberg, M., & Thorén, E. S. (2024) · American Journal of Audiology · doi:10.1044/2024_aja-24-00131 · Cited by 4
Identification of Spin Bowling Deliveries with an Advanced Smart Cricket Ball
Fuss, F. K., Doljin, B., & Ferdinands, R. E. D. (2024) · Sensors · doi:10.3390/s24227106 · Cited by 3
Oono, F., Murakami, K., Shinozaki, N., Kimoto, N., Masayasu, S., & Sasaki, S. (2024) · British Journal Of Nutrition · doi:10.1017/s0007114524002058 · Cited by 4
ClearLLab 10C reagents panel can be applied to analyze paucicellular samples by flow cytometry
Kajstura, M. A., LaBarge, T., & Evans, A. G. (2024) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.22215 · Cited by 3
Sundström, B., Johansson, S., & Wallin, A. (2024) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2024.106210 · Cited by 3
Intra-individual variability in voiding diaries of children with enuresis
Jørgensen, C. S., Pedersen, S. N., Dossche, L., Zhai, R., Maternik, M., Raes, A. M., Hagstrøm, S., Walle, J. V., Wen, J., Rittig, S., et al. (2024) · Journal of Pediatric Urology · doi:10.1016/j.jpurol.2024.11.020 · Cited by 3
Automated ultrasonographic pupillary assessment: a new neuro-ophthalmological assessment tool
Chen, W., Tang, M., Jin, Y., Chen, L., Lin, J., & Yang, X. (2024) · Journal of International Medical Research · doi:10.1177/03000605241299927 · Cited by 3
Direct Estimation vs. Indirect Metrics: Machine Learning Techniques for Cardiac Output Estimation
Roha, V. S., & Yuce, M. R. (2024) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors60989.2024.10784599 · Cited by 3
Chen, J., Stefanovski, D., Haughan, J. E., Jiang, Z., Soma, L. R., & Robinson, M. A. (2024) · Veterinary Immunology and Immunopathology · doi:10.1016/j.vetimm.2024.110868 · Cited by 3
Hansen, M. T., Husted, K. L. S., Modvig, J. L., Lange, K. K., Weinreich, C. M., Tranberg, C., Rømer, T., Ingersen, A., Dela, F., & Helge, J. W. (2025) · International Journal of Obesity · doi:10.1038/s41366-025-01713-9 · Cited by 4
Incorporating Lymph Node Size at CT as an N1 Descriptor in Clinical N Staging for Lung Cancer
Ahn, Y., Lee, S. M., Choe, J., Choi, S., Do, K., & Seo, J. B. (2025) · Radiology · doi:10.1148/radiol.241603 · Cited by 3
Cantor-Cutiva, L. C., Castillo‐Allendes, A., & Hunter, E. J. (2025) · Acoustics · doi:10.3390/acoustics7010006 · Cited by 4
Nugraha, R. V., Yunivita, V., Santoso, P., Hasanah, A. N., Meirina, T. N., Dewi, A. P., Atmaja, H. E., Brake, L. T., Aarnoutse, R. E., & Ruslami, R. (2025) · Journal of Chromatography B · doi:10.1016/j.jchromb.2025.124482 · Cited by 3
Virtual Tissue Microarrays for Validating Digital Biomarker Analysis in Colorectal Carcinoma
Jørgensen, A. L., Hamilton-Dutoit, S. J., Bramsen, J. B., Andersen, C. L., & Holm, I. E. (2025) · Laboratory Investigation · doi:10.1016/j.labinv.2025.104098 · Cited by 5
COMPAIR: a comparison of directly supervised clinic versus virtually supervised home spirometry
Pradhan, A. K., Pollington, J., Saralaya, D., Martin, M. J., Hughes, R., Arya, N., Sanders, N., Sharifian, H., Locke, K., Bonam, M., et al. (2025) · ERJ Open Research · doi:10.1183/23120541.01130-2024 · Cited by 3
Assessment of fluoride bio-accessibility in early childhood diets
Kronic, J., Duckworth, R. M., Angione, C., Levy, S. M., & Zohoori, F. V. (2025) · Frontiers in Oral Health · doi:10.3389/froh.2025.1526262 · Cited by 3
Ouattara, C. A., Compaoré, A., Ouédraogo, L. O., Ouédraogo, M., Ouattara, H., Coulibaly, M., Deng, L., Nikièma, Z., Hanley‐Cook, G., Argaw, A., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14051421 · Cited by 3
Holte, M. B., van Nistelrooij, N., Vinayahalingam, S., Bergé, S., Xi, T., & Pinholt, E. M. (2025) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2025.02.009 · Cited by 3
Yu, J., Høyland, K., Berg, E. A. R., Tannvik, T. D., Grenne, B. L., & Aakhus, S. (2025) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000007437 · Cited by 3
Validity and reliability of a novel impulse-based method to analyse human striking performance
Walters, S., Walters, L., Hoffman, B. W., Coltman, C. E., & Mills, D. E. (2025) · Journal of Sports Sciences · doi:10.1080/02640414.2025.2477855 · Cited by 4
Schwarz, B., Hardt, C., Friedrich, K., Prpic, M., Osterloh, A., Heppner, F. L., Ruprecht, K., Kappert, K., & Jahić, A. (2025) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.14466 · Cited by 3
Meixner, B. J., Matzka, M., & Sperlich, B. (2025) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2024-0450 · Cited by 4
Ünal, N., Paksoy, Y., & Güngör, Ö. F. (2025) · Archives animal breeding/Archiv für Tierzucht · doi:10.5194/aab-68-253-2025 · Cited by 3
Savini, G., Nicolosi, D., Hoffer, K. J., Coutinho, C. P., Curatolo, M. C., & Schiano‐Lomoriello, D. (2025) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000001671 · Cited by 3
Hayes, L. D., Sanal‐Hayes, N. E. M., Ellam, M., Mclaughlin, M., Swainson, M. G., & Sculthorpe, N. F. (2025) · Physiological Reports · doi:10.14814/phy2.70314 · Cited by 3
Ricard, E., Hayot, C., Clerc‐Urmès, I., Claudon, L., Desbrosses, K., & Pontonnier, C. (2025) · Wearable Technologies · doi:10.1017/wtc.2025.8 · Cited by 4
Kapan, A., Ristić, M., Konrad, A., & Waldhoer, T. (2025) · Physical Therapy · doi:10.1093/ptj/pzaf066 · Cited by 3
A computationally efficient algorithm for estimating respiratory rate from seismocardiogram
Ku, T.-H., & Lin, Y. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108030 · Cited by 3
Zheng, P., & Motl, R. W. (2025) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2025.05.005 · Cited by 4
Olsson, I., Kephart, G. C., Packer, T. L., Björk, S., Isaksson, U., Chen, Y.-T., Nordström, A., & Audulv, Å. (2025) · Journal of Patient-Reported Outcomes · doi:10.1186/s41687-025-00892-3 · Cited by 3
Riis, J., Wølke, S., Danielsen, M. B., Pedersen, M. M., Andersen, S., & Jørgensen, M. G. (2025) · European Geriatric Medicine · doi:10.1007/s41999-025-01240-w · Cited by 3
Wigh, I. M. N., Thomsen, A. K. A., Jensen, J. D., Jørgensen, H. S., & Andersen, S. L. (2025) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2025.2512998 · Cited by 3
Ooi, M. W. X., Wilson, M., Nicholls, J., Pass, B., Gupta, H., Hensor, E. M. A., & Robinson, P. J. (2025) · Skeletal Radiology · doi:10.1007/s00256-025-04960-z · Cited by 3
Choi, J., Ahn, Y., Kim, Y., Noh, H. N., Do, K., Seo, J. B., & Lee, S. M. (2025) · European Radiology · doi:10.1007/s00330-025-11715-w · Cited by 3
Biere, J., Groen, B. E., Pricken, M., & Keijsers, N. (2025) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2025.112817 · Cited by 4
Tsuchiya, M., Abe, K., Kubo, S., & Azuma, R. (2025) · Biosensors · doi:10.3390/bios15060381 · Cited by 3
Fílter, A., Olivares-Jabalera, J., Beltrán-Garrido, J. V., Santalla, A., Balsalobre‐Fernández, C., González, J. G., & De-la-Cruz-Torres, B. (2025) · Sports Biomechanics · doi:10.1080/14763141.2025.2524344 · Cited by 3
Kayali, M. K. D. E., Pichler, L., Gwinner, C., & Berndt, R. (2025) · Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine · doi:10.1016/j.jisako.2025.100920 · Cited by 3
A Head-to-Head Comparison of 18F-FP-CIT and 18F-FDOPA PET/CT in Early Parkinson Disease
Yoo, S., Ha, S., Ryu, D.-W., Oh, Y., & Kim, J. (2025) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000006024 · Cited by 3
Schelenz, A., Perugia, E., Wu, L., Skrodzka, E. B., & Kluk, K. (2025) · Scientific Reports · doi:10.1038/s41598-025-02093-w · Cited by 3
Ćuković, S., Luković, V., Zou, Y., Kaiser, M., Bertsch, M., Heidt, C., Studer, D., Farshad, M., & Laux, C. J. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110735 · Cited by 3
Mayr, S., Zicha, S., Giese, D., Kopp, M., Schmidt, S., Arndt, S., Sommerfeld, L., Kleiß, J.-M., Uder, M., & May, M. S. (2025) · Investigative Radiology · doi:10.1097/rli.0000000000001225 · Cited by 3
Wang, Y. F. J., Ferruzzi, J., Yeoh, S., Merchant, S. S., Maas, S. A., Weiss, J. A., Hsu, E. W., & Timmins, L. H. (2025) · Journal of Biomechanical Engineering · doi:10.1115/1.4069209 · Cited by 3
Ovchinnikov, A. N. (2025) · Scientific Reports · doi:10.1038/s41598-025-12380-1 · Cited by 6
Foot Measurements From Three‐Dimensional Scans: Elinvision 3DST Reliability
Jones, P. J., Rowlands, A. V., Davies, M. J., Webb, D. R., Gillies, C., & Shah, A. (2025) · Journal of Foot and Ankle Research · doi:10.1002/jfa2.70070 · Cited by 3
Dobler, F., Schwizer, R., & Alexander, N. (2025) · Gait & Posture · doi:10.1016/j.gaitpost.2025.07.331 · Cited by 3
Blair, G. W., MacCormick, I. J. C., McGrory, S., MacGillivray, T., Hamilton, I. F., Shi, Y., Chappell, F. M., Thrippleton, M. J., Stringer, M. S., Doubal, F., et al. (2025) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x251366079 · Cited by 5
Pupo, M. R., Diepersloot, E. C., de Paula, E. M., Dórea, J. R. R., Ghizzi, L. G., & Ferraretto, L. F. (2025) · Animals · doi:10.3390/ani15162349 · Cited by 3
Toubasi, A. A., Graham, M., Cutter, G., Gheen, C., Vinarsky, T., Wang, J., Zhang, J., Taylor, S., Eaton, J. E., Dortch, R. D., et al. (2025) · Multiple Sclerosis Journal · doi:10.1177/13524585251364766 · Cited by 4
Bouassa, R. M., Lukumbisa, S., & Bélec, L. (2025) · Diagnostics · doi:10.3390/diagnostics15172249 · Cited by 4
Comparison of alternative νLamax determination approaches in cycling and rowing
Micke, F., Mühlenhoff, S., Swoboda, A., & Held, S. (2025) · Journal of Sports Sciences · doi:10.1080/02640414.2025.2567795 · Cited by 3
Performance of the Egoo test for phenylalanine measurement in females with phenylketonuria
Schoen, M. S., Nath, S. V., & Singh, R. H. (2025) · Orphanet Journal of Rare Diseases · doi:10.1186/s13023-025-03989-6 · Cited by 3
Exploratory approach to speculate on body composition models for elite teenage basketball players
Mauro, M., Moro, F., & Toselli, S. (2025) · Scientific Reports · doi:10.1038/s41598-025-20293-2 · Cited by 3
Validation of the iButton and Flex sensors for measuring skin temperature
Bandiera, D., de Bardonnèche, J., Janry, P., Calas-Etienne, S., Aubin, J.-C., Tessitore, A., Pitsiladis, Y. P., & Racinais, S. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-025-06020-9 · Cited by 4
Eckmann, H. R., Razieh, C., CHASTIN, S. F. M., Sherar, L. B., Hansen, B. H., & Rowlands, A. V. (2025) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2025-0015 · Cited by 3
Tormási, J., Benes, E., Lengyel-Kónya, É., Berki, M., Horváth‐Szanics, E., & Abrankó, L. (2025) · Food Research International · doi:10.1016/j.foodres.2025.117297 · Cited by 3
Evaluation of a rheumatology patient prioritization triage system
Layton, K., Tovar, E. G., Wiggins, A. T., Rayens, M. K., & Salt, E. G. (2016) · Journal of the American Association of Nurse Practitioners · doi:10.1002/2327-6924.12367 · Cited by 3
Moulaeifard, M., Coquelin, L., Rinkevičius, M., Sološenko, A., Pfeffer, O., Bench, C. A., Hegemann, N., Vardanega, S., Nandi, M., Alastruey, J., et al. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109831 · Cited by 15
Tareke, T. W., Payan, N., Cochet, A., Arnould, L., Presles, B., Vrigneaud, J., Mériaudeau, F., & Lalande, A. (2026) · Scientific Reports · doi:10.1038/s41598-026-50945-w · Cited by 3
Fraction of exhaled nitric oxide in healthy elderly Tunisian subjects
Sfaxi, I., Saad, H. B., & Rouatbi, S. (2015) · Nitric Oxide · doi:10.1016/j.niox.2015.08.008 · Cited by 3
Kahlon, T. S., Xu, R., & Chow, F. I. (2001) · Food Chemistry · doi:10.1016/s0308-8146(01)00216-3 · Cited by 3
On the Estimation of Transmural Myocardial Shear by Means of MRI Tagging
Rossi, A. C., Arts, T. G. J., & Delhaas, T. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-21028-0_13 · Cited by 3
[Echocardiographic study of left ventricular geometry in spontaneously hypertensive rats].
Escudero, E. M., Pinilla, O. A., & Carranza, V. B. (2009) · PubMed · Cited by 3
Reproducibility of biomarkers in induced sputum and in serum from chronic smokers
Zuiker, R. G. J. A., Kamerling, I. M. C., Morelli, N., Calderon, C., Boot, J. D., de Kam, M., Diamant, Z., Burggraaf, J., & Cohen, A. F. (2015) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/j.pupt.2015.05.001 · Cited by 3
Statistische Bewertung neuer Methoden in der forensischen Anthropologie
Ramsthaler, F., & Verhoff, M. A. (2014) · Rechtsmedizin · doi:10.1007/s00194-014-0948-3 · Cited by 3
Guaita, S., Simó, J. M., Ferré, N., Joven, J., & Camps, J. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1557 · Cited by 3
Webb, A. R. (2002) · Springer eBooks · doi:10.1007/978-1-4615-6939-8_17 · Cited by 3
Yomota, M., Amano, I., Horita, N., Takezawa, T., Arai, T., To, M., & To, Y. (2012) · Internal Medicine · doi:10.2169/internalmedicine.51.7775 · Cited by 3
Effects of ramipril on renal function during progressive overpacing-induced heart failure in dogs
Mathieu, M., Motte, S., Ray, L., Pensis, A., Jespers, P., Brimioulle, S., Laroute, V., Naeije, R., & Entee, K. M. (2006) · American Journal of Veterinary Research · doi:10.2460/ajvr.67.7.1236 · Cited by 3
Comparing Test Scores Using Information From Criterion-Related Validity Studies
Beaujean, A. A., & McGlaughlin, S. M. (2015) · Applied Neuropsychology Child · doi:10.1080/21622965.2014.976863 · Cited by 3
Measurement of renal blood flow in human subjects using the ultrasound velocity profiling technique
Takano, R., Taniguchi, N., Itoh, K., & Kusano, E. (2006) · Journal of Medical Ultrasonics · doi:10.1007/s10396-005-0088-1 · Cited by 3
Popović, D., Ostojić, M., Popovic, B. M., Petrovic, M., Vujisic-Tesic, B. D., Kocijančić, A., Banovic, M. D., Arandjelovic, A., Stojiljković, S., Marković, V., et al. (2013) · Peptides · doi:10.1016/j.peptides.2013.01.017 · Cited by 3
Martin, W. J. J. M., Heymans, M. W., Skorpil, N. E., & Forouzanfar, T. (2012) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2012.02.016 · Cited by 3
Radiographic Measurement of the First Metatarsal
Taylor, N. G., Campbell, J. A., & Metcalfe, S. A. (2012) · Journal of the American Podiatric Medical Association · doi:10.7547/1020105 · Cited by 3
Huang, C.-C., Chen, N., Li, L., Yang, C., Hsiao, H.-F., Chen, Y.-H., Lin, H., & Kao, K. (2012) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31825dead7 · Cited by 3
Gürtler, V., Mayall, B. C., Wang, J., & Ghaly-Derias, S. (2013) · Journal of Virological Methods · doi:10.1016/j.jviromet.2013.10.043 · Cited by 3
Monitorage cardiovasculaire de l’opéré en chirurgie non cardiaque
Desebbe, O., Keller, G., Carre, A.-C., & Lehot, J.-J. (2013) · EMC-Anesthésie réanimation/Encyclopédie médico-chirurgicale. Anesthésie, réanimation · doi:10.1016/s0246-0289(12)57410-4 · Cited by 3
New enzymatic assay for serum urea nitrogen using urea amidolyase
Kimura, S., Iyama, S., Yamaguchi, Y., & Kanakura, Y. (2003) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.10067 · Cited by 3
Berglund, L., Berne, C., Svärdsudd, K., Garmo, H., & Zethelius, B. (2009) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2009.09.016 · Cited by 3
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.