STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 5,201–5,300 of 47,868
Pr??maud, A., Rousseau, A., Meur, Y. L., Lach??tre, G., & Marquet, P. (2004) · Therapeutic Drug Monitoring · doi:10.1097/00007691-200412000-00005 · Cited by 86
A research tool for measurement of recovery from sedation: The vancouver sedative recovery scale
Macnab, A. J., Levine, M., Glick, N., Susak, L. E., & Baker-Brown, G. (1991) · Journal of Pediatric Surgery · doi:10.1016/0022-3468(91)90594-j · Cited by 87
Which REE prediction equation should we use in normal-weight, overweight and obese women?
Siervo, M., Boschi, V., & Falconi, C. (2003) · Clinical Nutrition · doi:10.1054/clnu.2002.0625 · Cited by 98
Comparison of Nasal and Oral Inhalation during Exhaled Breath Condensate Collection
Vass, G., Huszár, É., Barát, E., Valyon, M., Kiss, D., Pénzes, I., Augusztinovicz, M., & Horváth, I. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200207-716bc · Cited by 86
The effect of processing on inflammatory markers in induced sputum
Louis, R. E., Shute, J. K., Goldring, K., Perks, B., Lau, L., Radermecker, M., & Djukanović, R. (1999) · European Respiratory Journal · doi:10.1183/09031936.99.13366099 · Cited by 86
Klug, B. H., & Bisgaard, H. F. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10071599 · Cited by 88
Whyte, M. K. B., Peters, A. M., Hughes, J. M., Henderson, B. L., Bellingan, G. J., Jackson, J. E., & Chilvers, E. R. (1992) · Thorax · doi:10.1136/thx.47.10.790 · Cited by 86
A review of impedance cardiography
Jensen, L. A., Yakimets, J., & Teo, K. K. (1995) · Heart & Lung · doi:10.1016/s0147-9563(05)80036-6 · Cited by 86
Benesch, J., Askendal, A., & Tengvall, P. (2000) · Colloids and Surfaces B Biointerfaces · doi:10.1016/s0927-7765(99)00136-8 · Cited by 93
Sedgwick, M. L., Rasmussen, H. S., & Cobbe, S. M. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90295-a · Cited by 86
Prediction of Fatness by Standing 8‐Electrode Bioimpedance: A Multiethnic Adolescent Population
Sluyter, J. D., Schaaf, D., Scragg, R. K. R., & Plank, L. D. (2010) · Obesity · doi:10.1038/oby.2009.166 · Cited by 85
Newer portable glucose meters—analytical improvement compared with previous generation devices?
Weitgasser, R., Gappmayer, B., & Pichler, M. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.10.1821 · Cited by 85
Bennett, D. A., Landry, D., Little, J., & Minelli, C. (2017) · BMC Medical Research Methodology · doi:10.1186/s12874-017-0421-6 · Cited by 85
Hanggi, M. P., Teuscher, U. M., Roos, M., & Peltomaki, T. A. (2008) · The European Journal of Orthodontics · doi:10.1093/ejo/cjn055 · Cited by 85
Salomon, L. J., Winer, N., Bernard, J. P., & Ville, Y. (2008) · Prenatal Diagnosis · doi:10.1002/pd.2016 · Cited by 85
Hernandez-Silveira, M., Ahmed, K., Ang, S.-S., Zandari, F., Mehta, T., Weir, R., Burdett, A., Toumazou, C., & Brett, S. J. (2015) · BMJ Open · doi:10.1136/bmjopen-2014-006606 · Cited by 83
Duncker, T., Tsang, S. H., Lee, W., Zernant, J., Allikmets, R., Delori, F. C., & Sparrow, J. R. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2014.08.017 · Cited by 84
Gupta, P., Jing, T., Marziliano, P., Cheung, C. Y.-L., Baskaran, M., Lamoureux, E. L., Wong, T. Y., Cheung, C. M. G., & Cheng, C. (2014) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2014.10.034 · Cited by 94
Ambulatory estimation of foot placement during walking using inertial sensors
Schepers, H. M., van Asseldonk, E. H. F., Baten, C. T. M., & Veltink, P. H. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.07.039 · Cited by 96
Tagliafico, A. S., Tagliafico, G., Tosto, S., Chiesa, F., Martinoli, C., Derchi, L. E., & Calabrese, M. (2008) · The Breast · doi:10.1016/j.breast.2008.09.005 · Cited by 90
Gaeta, M., Scribano, E., Mileto, A., Mazziotti, S., Rodolico, C., Toscano, A., Settineri, N., Ascenti, G., & Blandino, A. (2011) · Radiology · doi:10.1148/radiol.10101108 · Cited by 85
Vriens, B. E. P. J., de Vries, B., Lobbes, M. B. I., van Gastel, S. M., van den Berkmortel, F. W. P. J., Smilde, T. J., van Warmerdam, L. J. C., de Boer, M., van Spronsen, D. J., Smidt, M. L., et al. (2015) · European Journal of Cancer · doi:10.1016/j.ejca.2015.10.010 · Cited by 90
Huang, J., Savini, G., Hoffer, K. J., Chen, H., Lu, W., Hu, Q., Bao, F., & Wang, Q. (2016) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2016-308352 · Cited by 85
Lauridsen, M. H., Uldbjerg, N., Henriksen, T. B., Petersen, O. B., Stausbøl‐Grøn, B., Matthiesen, N. B., Peters, D. A., Ringgaard, S., & Hjortdal, V. E. (2017) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.117.006459 · Cited by 89
May, S. L., Ballard, A., Khadra, C., Gouin, S., Plint, A. C., Villeneuve, E., Mâsse, B. R., Tsze, D. S., Neto, G. M., Drendel, A. L., et al. (2018) · Pain · doi:10.1097/j.pain.0000000000001236 · Cited by 100
Stone, J. D., Rentz, L. E., Forsey, J., Ramadan, J., Markwald, R. R., Finomore, V. S., Galster, S. M., Rezai, A., & Hagen, J. A. (2020) · Nature and Science of Sleep · doi:10.2147/nss.s270705 · Cited by 82
Hansen, E. M., McCartney, C. N., Sweeney, R. S., Palimenio, M. R., & Grindstaff, T. L. (2015) · Europe PMC (PubMed Central) · Cited by 85
Métodos estadísticos de evaluación de la concordancia y la reproducibilidad de pruebas diagnósticas
Cortés-Reyes, É., Rubio-Romero, J. A., & Gaitán‐Duarte, H. (2010) · Revista Colombiana de Obstetricia y Ginecología · doi:10.18597/rcog.271 · Cited by 205
Haberman, C. E., Kang, C. W., Morgan, J. D., & Brown, S. A. (2006) · PubMed · Cited by 112
Newgard, C. D., Zive, D. M., Jui, J., Weathers, C. C., & Daya, M. R. (2012) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01275.x · Cited by 85
Repeatability of cold pressor test-induced flow increase assessed with H(2)(15)O and PET.
Siegrist, P. T., Gaemperli, O., Koepfli, P., Schepis, T., Namdar, M., Valenta, I., Aiello, F., Fleischmann, S., Alkadhi, H., & Kaufmann, P. A. (2006) · PubMed · Cited by 90
Use of echocardiography for hemodynamic monitoring
Brown, J. (2002) · Critical Care Medicine · doi:10.1097/00003246-200206000-00039 · Cited by 85
Takai, Y., Ohta, M., Akagi, R., Kato, E., Wakahara, T., Kawakami, Y., Fukunaga, T., & Kanehisa, H. (2014) · The Journal of nutrition, health and aging · doi:10.1007/s12603-013-0419-7 · Cited by 86
Sverzellati, N., Cademartiri, F., Bravi, F., Martini, C., Gira, F. A., Maffei, E., Marchianò, A., La Vecchia, C., De Filippo, M., Kuhnigk, J.-M., et al. (2012) · Radiology · doi:10.1148/radiol.11110364 · Cited by 85
Firstenberg, M. S., Vandervoort, P. M., Greenberg, N. L., Smedira, N. G., McCarthy, P. M., Garcia, M. J., & Thomas, J. D. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00963-3 · Cited by 85
Piccoli, A., Pastori, G., Guizzo, M., Rebeschini, M., Naso, A., & Cascone, C. (2004) · Kidney International · doi:10.1111/j.1523-1755.2005.00083.x · Cited by 94
Jerrard-Dunne, P., Mahmud, A., & Feely, J. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f35265 · Cited by 94
A Rapid, Quantitative Immunofunctional Assay for Measuring Human Leptin
Kratzsch, J., Berthold, A., Lammert, A., Reuter, W., Keller, E., & Kiess, W. (2002) · Hormone Research in Paediatrics · doi:10.1159/000057963 · Cited by 85
Cervical joint position sense: an intra- and inter-examiner reliability study
Στριμπάκος, Ν., Sakellari, V., Gioftsos, G., Kapreli, E., & Oldham, J. A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.11.019 · Cited by 85
Reliability of Binocular Vision Measurements Used in the Classification of Convergence Insufficiency
ROUSE, M. W., Borsting, E. J., DeLand, P. N., & The Convergence Insufficiency and Reading Study (CIRS) Group (2002) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2002.tb01457.x · Cited by 85
Bu, L., Munns, S., Zhang, H., Disterhoft, M., Dixon, M., Stolpen, A. H., Milan Sonka, A., SCHOLZ, T. D., Mahoney, L. T., & Ge, S. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.11.002 · Cited by 85
Arabic version of the geriatric oral health assessment Index
Atieh, M. A. (2008) · Gerodontology · doi:10.1111/j.1741-2358.2007.00195.x · Cited by 101
Magnetic resonance imaging of shoulders with idiopathic adhesive capsulitis: reliability of measures
Lefèvre‐Colau, M., Drapé, J., Fayad, F., Rannou, F., Diche, T., Minvielle, F., Demaille-Wlodyka, S., Mayoux-Benhamou, M. A., Fermanian, J., Poiraudeau, S., et al. (2005) · European Radiology · doi:10.1007/s00330-005-2830-x · Cited by 85
Hamacher, D., Hamacher, D., Taylor, W. R., Singh, N. B., & Schega, L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.01.020 · Cited by 85
The Development of Validated Bulbar Redness Grading Scales
Schulze, M., JONES, D. A., & SIMPSON, T. L. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e318157ac9e · Cited by 94
Busque, L., Paquette, Y., Provost, S., Roy, D.-C., Levine, R. L., Mollica, L., & Gary Gilliland, D. (2009) · Blood · doi:10.1182/blood-2008-12-195677 · Cited by 86
Bein, B., Meybohm, P., Cavus, E., Renner, J., Tonner, P. H., Steinfath, M., Scholz, J., & Doerges, V. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000268140.02147.ed · Cited by 85
Henneman, M. M., Schuijf, J. D., Jukema, J. W., Holman, E. R., Lamb, H. J., Roos, A., van der Wall, E. E., & Bax, J. J. (2006) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2006.03.005 · Cited by 85
Validation of BIA in Obese Children and Adolescents and Re‐evaluation in a Longitudinal Study
Haroun, D., Croker, H., Viner, R. M., Williams, J. E., Darch, T. S., Fewtrell, M. S., Eaton, S., & Wells, J. C. K. (2009) · Obesity · doi:10.1038/oby.2009.98 · Cited by 85
Raum, K., Leguerney, I., Chandelier, F., Talmant, M., Saı̈ed, A., Peyrin, F., & Laugier, P. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/3/017 · Cited by 85
Mc Naughton, L. R., Thompson, D., Philips, G., Backx, K., & Crickmore, L. (2002) · International Journal of Sports Medicine · doi:10.1055/s-2002-20133 · Cited by 86
Stage-Related Effect of Statin Treatment on the Progression of Aortic Valve Sclerosis and Stenosis
Antonini‐Canterin, F., Hîrşu, M., Popescu, B. A., Leiballi, E., Piazza, R., Pavan, D., Ginghină, C., & Nicolosi, G. L. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.04.056 · Cited by 85
Klein, M., & Birch, D. G. (2009) · Documenta Ophthalmologica · doi:10.1007/s10633-009-9204-7 · Cited by 85
Pereira, P. M. G., Insausti, R., Artacho‐Pérula, E., Salmenpera, T. M., Kälviäinen, R. K., & Pitkänen, A. (2005) · PubMed Central · Cited by 103
Widjaja, E., Oxtoby, J., Hale, T. L., Jones, P., Harden, P. N., & McCall, I. W. (2004) · British Journal of Radiology · doi:10.1259/bjr/24988054 · Cited by 97
Muthurangu, V., Atkinson, D., Maxime Sermesant, B., Miquel, M. E., Hegde, S. R., Johnson, R. I., Andriantsimiavona, R., Taylor, A. M., Baker, E. J., Tulloh, R. M. R., et al. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00957.2004 · Cited by 85
Neubauer, A. S., Kernt, M., Haritoglou, C., Priglinger, S. G., Kampik, A., & ULBIG, M. W. (2007) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-007-0631-4 · Cited by 96
Diagnostic accuracy of cardiac metaiodobenzylguanidine scintigraphy in Parkinson disease
Sawada, H., Oeda, T., Yamamoto, K., Kitagawa, N., Mizuta, E., Hosokawa, R., Ohba, M., Nishio, R., Yamakawa, K., Takeuchi, H., et al. (2008) · European Journal of Neurology · doi:10.1111/j.1468-1331.2008.02372.x · Cited by 85
Dutman, A. E., Stafleu, A., Kruizinga, A., Brants, H. A., Westerterp, K. R., Kistemaker, C., Meuling, W. J., & Goldbohm, R. A. (2011) · Public Health Nutrition · doi:10.1017/s1368980010002119 · Cited by 84
Poutanen, T., Ikonen, A., Vainio, P., Jokinen, E., & Tikanoja, T. (2000) · Heart · doi:10.1136/heart.83.5.537 · Cited by 85
Hesse, B., Schuele, S., THAMILASARAN, M., Thomas, J. D., & Rodriguez, L. L. (2003) · European Journal of Echocardiography · doi:10.1016/s1525-2167(03)00046-5 · Cited by 85
Hallal, P. C., Simoes, E., Reichert, F. F., Azevedo, M. R., Ramos, L. R., Pratt, M., & Brownson, R. C. (2010) · Journal of Physical Activity and Health · doi:10.1123/jpah.7.3.402 · Cited by 87
Repeatability and reproducibility of upper eyelid measurements
Boboridis, K. G., Assi, A., Indar, A., Bunce, C., & Tyers, A. G. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.1.99 · Cited by 88
Field based reliability and validity of the bioharness™ multivariable monitoring device.
Johnstone, J., Ford, P. A., Hughes, G., Watson, T., Mitchell, A., & Garrett, A. T. (2012) · Repository@Hull (Worktribe) (University of Hull) · Cited by 110
Ghadri, J. R., Goetti, R. P., Fiechter, M., Pazhenkottil, A. P., Kuest, S. M., Nkoulou, R. N., Windler, C., Buechel, R. R., Herzog, B. A., Gaemperli, O., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr157 · Cited by 90
Gallicchio, R., Mansueto, G., Simeon, V., Nardelli, A., Guariglia, R., Capacchione, D., Soscia, E., Pedicini, P., Gattozzi, D. A., Musto, P., et al. (2014) · European Journal Of Haematology · doi:10.1111/ejh.12268 · Cited by 91
Observer variability in the interpretation of contrast enhanced MRI of the breast
MUSSURAKIS, S., Buckley, D. L., Coady, A., Turnbull, L. W., & Horsman, A. (1996) · British Journal of Radiology · doi:10.1259/0007-1285-69-827-1009 · Cited by 85
Power, M., Hamdy, S., Goulermas, J. Y., Tyrrell, P. J., Turnbull, I. W., & Thompson, D. G. (2009) · Dysphagia · doi:10.1007/s00455-008-9198-4 · Cited by 86
Chapman, M. J., Besanko, L. K., Burgstad, C. M., Fraser, R. J., Bellon, M., O'Connor, S., Russo, A., Jones, K. L., Lange, K., Nguyen, N. Q., et al. (2011) · Gut · doi:10.1136/gut.2010.227934 · Cited by 85
Schäfers, K. P., Spinks, T. J., Camici, P. G., Bloomfield, P. M., Rhodes, C. G., Law, M. P., Baker, C., & Rimoldi, O. E. (2002) · PubMed · Cited by 85
Baverel, L. P., Brilhault, J. M., Odri, G. A., Boissard, M., & Lintz, F. (2016) · Foot and Ankle Surgery · doi:10.1016/j.fas.2016.02.003 · Cited by 85
Garver, K., Hawley, L. M., McClure, C., Schroeder, T., Aldous, S., Doig, F., Snow, M., Edes, S., Baynes, C., & Richard, J. (2011) · Diseases of Aquatic Organisms · doi:10.3354/dao02344 · Cited by 92
Evaluation of a smartphone food diary application using objectively measured energy expenditure
Pendergast, F. J., Ridgers, N. D., Worsley, A., & McNaughton, S. A. (2017) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0488-9 · Cited by 98
Holm, I., Friis, A., Storheim, K., & Brox, J. I. (2003) · Spine · doi:10.1097/01.brs.0000058931.31599.e2 · Cited by 85
Glynn, C. C., Greene, G. W., Winkler, M. F., & Albina, J. E. (1999) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607199023003147 · Cited by 87
Van Paesschen, W., Duncan, J. S., Stevens, J. M., & Connelly, A. (1998) · Epilepsia · doi:10.1111/j.1528-1157.1998.tb01432.x · Cited by 87
Heuschmid, M., Rothfuss, J. K., Schroeder, S., Fenchel, M. C., Stauder, N. I., Burgstahler, C., Franow, A., Kuzo, R. S., Kuettner, A., Miller, S., et al. (2005) · European Radiology · doi:10.1007/s00330-005-0015-2 · Cited by 85
Lack of agreement between thermodilution and carbon dioxide‐rebreathing cardiac output
Nilsson, L. B., Eldrup, N., & Berthelsen, P. G. (2001) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2001.045006680.x · Cited by 96
Comparison of a digital and a handheld infrared pupillometer for determining scotopic pupil diameter
Kohnen, T., Terzi, E., Bühren, J., & Kohnen, E.-M. (2003) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(02)01898-9 · Cited by 90
Birch, D. G., Hood, D. C., Locke, K. G., Hoffman, D. R., & Tzekov, R. T. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.8.1045 · Cited by 87
Cabanes, L., Coste, J., Dérumeaux, G., Jeanrenaud, X., Lamy, C., Zuber, M., & Mas, J. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.116718 · Cited by 85
Veillon, P., Payan, C., Picchio, G., Maniez-Montreuil, M., Guntz, P., & Lunel, F. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.7.3212-3220.2003 · Cited by 85
Ultrasound Imaging of the Thoracic Epidural Space
Grau, T., Leipold, R. W., Delorme, S., Martin, E., & Motsch, J. (2002) · Regional Anesthesia & Pain Medicine · doi:10.1053/rapm.2002.29239 · Cited by 85
Accuracy of home blood glucose meters during hypoglycemia
Trajanoski, Z., Brunner, G., Gfrerer, R., Wach, P., & Pieber, T. (1996) · Diabetes Care · doi:10.2337/diacare.19.12.1412 · Cited by 85
Fowler, P., Fuller, M., Glasbey, C., Cameron, G., & Foster, M. (1992) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/56.1.7 · Cited by 85
Virkola, K., Pesonen, E. J., Åkerblom, H., & Siimes, M. (1997) · Acta Paediatrica · doi:10.1111/j.1651-2227.1997.tb14847.x · Cited by 85
Evaluation of an oscillometric blood pressure monitor for use in anesthetized cats
Pedersen, K. M., Butler, M. A., Ersbøll, A. K., & Pedersen, H. D. (2002) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.2002.221.646 · Cited by 92
Young, G. R., Humphrey, P. R. D., Shaw, M. D. M., Nixon, T. E., & Smith, E. (1994) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.57.12.1466 · Cited by 89
Sedation with propofol during surgery under local blockade
Skipsey, I. G., Colvin, J., Mackenzie, N., & Kenny, G. N. C. (1993) · Anaesthesia · doi:10.1111/j.1365-2044.1993.tb06903.x · Cited by 85
Sadhu, A. R., Serrano, I. A., Xu, J., Nisar, T., Lucier, J., Pandya, A. R., & Patham, B. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820964264 · Cited by 84
N95 and P100 Respirator Filter Efficiency Under High Constant and Cyclic Flow
Eshbaugh, J. P., Gardner, P. D., Richardson, A. W., & Hofacre, K. C. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802558196 · Cited by 84
Shibata, M., Hashi, S., Nakanishi, H., Masuda, S., Katsura, T., & Yano, I. (2012) · Biomedical Chromatography · doi:10.1002/bmc.2726 · Cited by 94
Silent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty
Wynn-Jones, H., Macnair, R., Wimhurst, J. A., Chirodian, N., Derbyshire, B., Toms, A. P., & Cahir, J. G. (2011) · Acta Orthopaedica · doi:10.3109/17453674.2011.579518 · Cited by 84
Tao, Q., Milles, J., Zeppenfeld, K., Lamb, H. J., Bax, J. J., Reiber, J. H. C., & van der Geest, R. J. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22422 · Cited by 84
Gaens, M. E., Backes, W. H., Rozel, S., Lipperts, M., Sanders, S. N., Jaspers, K., Cleutjens, J. P. M., Sluimer, J. C., Heeneman, S., Daemen, M. J. A. P., et al. (2012) · Radiology · doi:10.1148/radiol.12120499 · Cited by 89
Jaremko, J. L., Mabee, M., Swami, V. G., Jamieson, L., Chow, K., & Thompson, R. B. (2014) · Radiology · doi:10.1148/radiol.14140451 · Cited by 84
Egi, M., Finfer, S. R., & Bellomo, R. (2011) · CHEST Journal · doi:10.1378/chest.10-1478 · Cited by 95
Comparing Body Composition Assessment Tests in Long-term Hemodialysis Patients
Bross, R., Chandramohan, G., Kovesdy, C. P., Oreopoulos, A., Noori, N., Golden, S., Benner, D. A., Kopple, J. D., & Kalantar‐Zadeh, K. (2010) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2009.12.031 · Cited by 91
Validation of a Quantitative Magnetic Resonance Method for Measuring Human Body Composition
Napolitano, A., Miller, S. R., Murgatroyd, P. R., Coward, W. A., Wright, A., Finer, N., De Bruin, T. W., Bullmore, E. T., & Nunez, D. J. (2008) · Obesity · doi:10.1038/oby.2007.29 · Cited by 84
Pulli, B., Schaefer, P. W., Hakimelahi, R., Chaudhry, Z. A., Lev, M. H., Hirsch, J. A., González, R. G., & Yoo, A. J. (2011) · Radiology · doi:10.1148/radiol.11110896 · Cited by 84
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.