Voltage stability analysis of radial distribution networks
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal capacitor placement on radial distribution systems
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.19265 · Cited by 2,062
Simple and efficient method for load flow solution of radial distribution networks
Das, D., Kothari, D. P., & Kalam, A. (1995) · International Journal of Electrical Power & Energy Systems · doi:10.1016/0142-0615(95)00050-0 · Cited by 702
Self-citation
Cited by
Moradi, M. H., & Abedini, M. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2011.08.023 · Cited by 1,073
Radial Distribution Load Flow Using Conic Programming
Jabr, R. A. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879234 · Cited by 713
Kefayat, M., Lashkar Ara, A., & Nabavi Niaki, S. A. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.12.037 · Cited by 401
Optimal Reconfiguration of Radial Distribution Systems to Maximize Loadability
Venkatesh, B., Ranjan, R., & Gooi, H. B. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.818739 · Cited by 348
Sultana, S., & Roy, P. K. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.06.031 · Cited by 331
Injeti, S. K., & Prema Kumar, N. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.08.043 · Cited by 313
Ameli, A., Bahrami, S., Khazaeli, F., & Haghifam, M.-R. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2300845 · Cited by 269
Gampa, S. R., Jasthi, K., Goli, P., Das, D., & Bansal, R. C. (2020) · Journal of Energy Storage · doi:10.1016/j.est.2019.101117 · Cited by 245
Self-citationAzizivahed, A., Arefi, A., Ghavidel, S., Shafie-khah, M., Li, L., Zhang, J., & Catalao, J. P. S. (2020) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2019.2901429 · Cited by 212
“According to the load flow technique, (14) and (15) can be obtained; and from these equations, (16) can be obtained [22].”
BackgroundMethodState of the art of cyber-physical systems security: An automatic control perspective
Zacchia Lun, Y., D’Innocenzo, A., Smarra, F., Malavolta, I., & Di Benedetto, M. D. (2019) · Journal of Systems and Software · doi:10.1016/j.jss.2018.12.006 · Cited by 211
“Studies on power distribution use 33-bus [110] and 69-bus [94] radial distribution test systems in one primary study [S056], and IEEE 24-bus reliability test system (MatPower case24 ieee rts) in”
MethodZeinalzadeh, A., Mohammadi, Y., & Moradi, M. H. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.12.010 · Cited by 211
“This index, which can be evaluated at all buses, was presented in [20].”
BackgroundOptimal allocation and sizing of DG units considering voltage stability, losses and load variations
Poornazaryan, B., Karimyan, P., Gharehpetian, G. B., & Abedi, M. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.12.034 · Cited by 188
Podder, A. K., Sadamoto, T., & Chakrabortty, A. (2024) · 2024 American Control Conference (ACC) · doi:10.23919/acc60939.2024.10644779 · Cited by 4
“Here, the voltage stability index (VSI) of the EVCS buses is also computed following [11].”
Method
Metadata
- Authors
- Chakravorty, M., & Das, D.
- Venue
- International Journal of Electrical Power & Energy Systems
- Publisher
- Elsevier BV
- Published
- 2001-02
- Volume
- 23
- Issue
- 2
- Pages
- 129-135
- ISSN
- 0142-0615 (ISSN-L)
- OpenAlex
- W2068890265
- Cited by
- 596
- References
- 2
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.