The relative influence of the topography and chemistry of TiAl6V4 surfaces on osteoblastic cell behaviour
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Proliferation and adhesion of mouse (MC3T3-E1) osteoblastic cells and primary human osteoblastic cells were carried out on Ti6Al4V titanium alloy samples with varied surface roughnesses. Mechanically or manually polished surfaces were prepared to produce respectively non-oriented or oriented residual polishing grooves. Sand-blasted surfaces were prepared using 500 microm or 3 mm alumina particles. Surface roughness parameters showed a negative correlation in comparison to proliferation and adhesion parameters. X-ray microprobe chemical surface microanalysis showed complete disturbance of the surface element composition of the Ti6Al4V alloy following sand-blasting treatment. An AlOx-enriched layer was observed on sample surfaces. This may lead to the suspicion that the concomittant effect of surface roughness amplitude and AlOx surface concentration has an effect on osteoblastic cell proliferation and adhesion. These findings show the significance of chemical surface analysis after any surface treatment of titanium-based implants before any biological use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
Martin, J. Y., Schwartz, Z., Hummert, T. W., Schraub, D. M., Simpson, J., Lankford, J., Dean, D. D., Cochran, D. L., & Boyan, B. D. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290314 · Cited by 1,111
Davies, J. E. (1991) · University of Toronto Press eBooks · doi:10.3138/9781442671508 · Cited by 644
Kieswetter, K., Schwartz, Z., Hummert, T. W., Cochran, D. L., Simpson, J., Dean, D. D., & Boyan, B. D. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199609)32:1<55::aid-jbm7>3.0.co;2-o · Cited by 565
Anselme, K., Bigerelle, M., Noel, B., Dufresne, E., Judas, D., Iost, A., & Hardouin, P. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200002)49:2<155::aid-jbm2>3.0.co;2-j · Cited by 507
Self-citationTitanium surface roughness alters responsiveness of MG63 osteoblast-like cells to 1?,25-(OH)2D3
Boyan, B. D., Batzer, R., Kieswetter, K., Liu, Y., Cochran, D. L., Szmuckler-Moncler, S., Dean, D. D., & Schwartz, Z. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199801)39:1<77::aid-jbm10>3.0.co;2-l · Cited by 370
An evaluation of variables influencing implant fixation by direct bone apposition
Thomas, K. A., & Cook, S. D. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190802 · Cited by 313
Kasemo, B., & Lausmaa, J. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820221307 · Cited by 237
Preparation and surface spectroscopic characterization of oxide films on Ti6Al4V
Ask, M., Lausmaa, J., & Kasemo, B. (1989) · Applied Surface Science · doi:10.1016/0169-4332(89)90013-5 · Cited by 212
Bordji, K., Jouzeau, J. Y., Mainard, D., Payan, E., Netter, P., Rie, K. T., Stucky, T., & Hage-Ali, M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)83289-3 · Cited by 195
Vrouwenvelder, W. C. A., Groot, C. G., & de Groot, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270407 · Cited by 192
Material-Tissue Interfaces: The Role of Surface Properties and Processes
Kasemo, B., & Lausmaa, J. (1994) · Environmental Health Perspectives · doi:10.1289/ehp.94102s541 · Cited by 162
Bone Cell Expression on Titanium Surfaces is Altered by Sterilization Treatments
Stanford, C. M., Keller, J. C., & Solursh, M. (1994) · Journal of Dental Research · doi:10.1177/00220345940730050801 · Cited by 137
Vezeau, P. J., Gf, K., Draughn, R. A., & Keller, J. C. (1996) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(96)90694-1 · Cited by 109
Prosthetic Metals Interfere With the Functions of Human Osteoblast Cells In Vitro
Wang, J., Wicklund, B., Gustilo, R. B., & Tsukayama, D. T. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199706000-00030 · Cited by 91
Evans, E. J. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90170-8 · Cited by 81
Naji, A., & Harmand, M. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240706 · Cited by 76
Itakura, Y., Kosugi, A., Sudo, H., Yamamoto, S., & Kumegawa, M. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820220703 · Cited by 57
Effect of microstructure of titanium surface on the behaviour of osteogenic cell line MC3T3-E1
NISHIMURA, N., & Kawai, T. (1998) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008851115846 · Cited by 21
Cited by
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Harnessing nanotopography and integrin–matrix interactions to influence stem cell fate
Dalby, M. J., Gadegaard, N., & Oreffo, R. O. C. (2014) · Nature Materials · doi:10.1038/nmat3980 · Cited by 1,082
“with increasing substrate stiffness has been demonstrated [32].”
BackgroundPaital, S. R., & Dahotre, N. B. (2009) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2009.05.001 · Cited by 673
Effects of topography and composition of titanium surface oxides on osteoblast responses
Zhu, X., Chen, J., Scheideler, L., Reichl, R., & Geis-Gerstorfer, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.011 · Cited by 534
Kunzler, T. P., Drobek, T., Schuler, M., & Spencer, N. D. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.019 · Cited by 518
Metadata
- Authors
- Anselme, K., Linez, P., Bigerelle, M., Le Maguer, D., Le Maguer, A., Hardouin, P., Hildebrand, H. F., Iost, A., & Leroy, J. M.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2000-08
- Volume
- 21
- Issue
- 15
- Pages
- 1567-1577
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2008124574
- Cited by
- 413
- References
- 19
- FWCI
- 10.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.