Starch-based biodegradable hydrogels with potential biomedical applications as drug delivery systems
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The design and preparation of novel biodegradable hydrogels developed by the free radical polymerization of acrylamide and acrylic acid, and some formulations with bis-acrylamide, in the presence of a corn starch/ethylene-co-vinyl alcohol copolymer blend (SEVA-C), is reported. The redox system benzoyl peroxide (BPO) and 4-dimethylaminobenzyl alcohol (DMOH) initiated the polymerization at room temperature. Xerogels were characterized by 1H NMR and FTIR spectroscopies. Swelling studies were performed as a function of pH in different buffer solutions determining the water-transport mechanism that governs the swelling behaviour. Degradation studies of the hydrogels were performed in simulated physiological solutions for time up to 90 days, determining the respective weight loss, and analyzing the solution residue by 1H NMR. The mechanical properties of the xerogels were characterized by tensile and compressive tests, as well as by dynamo-mechanical analysis (DMA). Dynamo-mechanical parameters are also reported for hydrated samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for Medical and Related Applications
(1976) · ACS Symposium Series · doi:10.1021/bk-1976-0031 · Cited by 582
Peppas, N. A., & Franson, N. M. (1983) · Journal of Polymer Science: Polymer Physics Edition · doi:10.1002/pol.1983.180210614 · Cited by 401
Aoki, T., Kawashima, M., Katono, H., Sanui, K., Ogata, N., Okano, T., & Sakurai, Y. (1994) · Macromolecules · doi:10.1021/ma00082a010 · Cited by 314
Zhu, K. J., Xiangzhou, L., & Shilin, Y. (1990) · Journal of Applied Polymer Science · doi:10.1002/app.1990.070390101 · Cited by 313
Demirgöz, D., Elvira, C., Mano, J. F., Cunha, A. M., Piskin, E., & Reis, R. L. (2000) · Polymer Degradation and Stability · doi:10.1016/s0141-3910(00)00102-6 · Cited by 184
Self-citationYouxin, L., & Kissel, T. (1993) · Journal of Controlled Release · doi:10.1016/0168-3659(93)90155-x · Cited by 166
New starch-based thermoplastic hydrogels for use as bone cements or drug-delivery carriers
Pereira, C. S., Cunha, A. M., Reis, R. L., Vázquez‐Lasa, B., & Román, J. S. (1998) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008944127971 · Cited by 150
Self-citationNovel pH-sensitive hydrogels with adjustable swelling kinetics
Akala, E. O., Kopečková, P., & Kopec̆ek, J. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00023-4 · Cited by 149
Bearinger, J. P., Castner, D. G., & Healy, K. E. (1998) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856298x00064 · Cited by 91
Grulke, E. A. (1999) · Cited by 77
5-Fluorouracil release from copolymeric hydrogels of itaconic acid monoester
Blanco, M. D., García, O., Trigo, R. M., Teijón, J., & Katime, I. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85906-0 · Cited by 72
Hydrogels as an interface between bone and an implant
Netti, P. A., Shelton, J. C., Revell, P. A., PIRIE, G., Smith, S., Ambrosio, L., Nicolais, L., & Bonfield, W. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90211-j · Cited by 65
Vernon, B., Kim, S. W., & Bae, Y. H. (1999) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856299x00126 · Cited by 65
Fabrication and characteristics of polyHEMA artificial skin with improved tensile properties
Young, C.-D., Wu, J., & Tsou, T. (1998) · Journal of Membrane Science · doi:10.1016/s0376-7388(98)00097-0 · Cited by 62
Mano, J. F., Vaz, C. M., Mendes, S. C., Reis, R. L., & Cunha, A. M. (1999) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008916901009 · Cited by 62
Self-citationBastioli, C. (1995) · Springer eBooks · doi:10.1007/978-94-011-0571-2_6 · Cited by 60
Oliveira, A. L., Elvira, C., Reis, R. L., Vázquez‐Lasa, B., & Roma´n, J. S. (1999) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008900428325 · Cited by 59
Self-citationHeller, J., Pangburn, S., & Roskos, K. V. (1990) · Biomaterials · doi:10.1016/0142-9612(90)90112-4 · Cited by 56
Taguchi, T., Kishida, A., Sakamoto, N., & Akashi, M. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980905)41:3<386::aid-jbm7>3.0.co;2-8 · Cited by 39
Poly(vinyl alcohol)-heparin hydrogels as sensor catheter membranes
Brinkman, E., van der Does, L., & Bantjes, A. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90134-v · Cited by 39
Development of self-anchoring bone implants. I. Processing and material characterization
Abusafieh, A. A., Siegler, S., & Kalidindi, S. R. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199724)38:4<314::aid-jbm3>3.0.co;2-r · Cited by 23
Cited by
Biomedical applications of hydrogels: A review of patents and commercial products
Caló, E., & Khutoryanskiy, V. V. (2015) · European Polymer Journal · doi:10.1016/j.eurpolymj.2014.11.024 · Cited by 2,634
Bone Tissue Engineering: State of the Art and Future Trends
Salgado, A. J., Coutinho, O. P., & Reis, R. L. (2004) · Macromolecular Bioscience · doi:10.1002/mabi.200400026 · Cited by 1,681
Self-citationResponsive polymers in controlled drug delivery
Bajpai, A. K., Shukla, S. K., Bhanu, S., & Kankane, S. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.005 · Cited by 1,391
Fundamental Concepts of Hydrogels: Synthesis, Properties, and Their Applications
Bashir, S., Hina, M., Iqbal, J., Rajpar, A. H., Mujtaba, M. A., Alghamdi, N. A., Wageh, S., Ramesh, K., & Ramesh, S. (2020) · Polymers · doi:10.3390/polym12112702 · Cited by 1,160
Design and applications of interpenetrating polymer network hydrogels. A review
Dragan, E. S. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.01.065 · Cited by 992
Metadata
- Authors
- Elvira, C., Mano, J. F., San Román, J., & Reis, R. L.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2002-05
- Volume
- 23
- Issue
- 9
- Pages
- 1955-1966
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1990044730
- Cited by
- 357
- References
- 21
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.