Acrylic acid grafting and collagen immobilization on poly(ethylene terephthalate) surfaces for adherence and growth of human bladder smooth muscle cells
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
In tissue engineering, degradable or non-degradable polymer matrices can act as cell-carrier-scaffolds. Cell adhesion and growth on these scaffolds can be promoted by immobilizing extracellular matrix proteins. Therefore, in this study, polymer poly(ethylene terephthalate) (PET) films were surface modified by graft polymerization of acrylic acid, to subsequently allow collagen (types I and III) immobilization and human smooth muscle cell expansion. The surfaces of PET were activated by plasma, followed by acrylic acid graft polymerization, resulting in covalently bound brushes, containing an average of either 0.22+/-0.1 or 5.93+/-0.87 microg/cm2 of poly(acrylic acid) (PAA). Subsequent electrostatic adsorption of collagen gave a surface concentration of 4.96 and 17.2 microg/cm2, respectively, as determined using radiolabelled 125I collagen. Both PET films grafted with 0.22 microg/cm2 of PAA with or without adsorbed collagen were apt for smooth muscle cell adhesion and proliferation. However, films grafted with 5.93 microg/cm2 were not. PAA-grafted PET films, onto which serum proteins of the culture medium adsorbed spontaneously, proved to be better matrices than films on which collagen has been immobilized. It, therefore, can be speculated that other serum proteins are more important than collagen for the human smooth muscle cell adhesion and growth on surface-modified polymer matrices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Friess, W. (1998) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(98)00017-4 · Cited by 1,130 · cited 1×
“In accordance with other authors [23,24], we have opted for collagen being an important attachment protein, biodegradable and non-immunogenic, especially when the terminal telopeptides are removed.”
BackgroundDe novo reconstitution of a functional mammalian urinary bladder by tissue engineering
Oberpenning, F., Meng, J., Yoo, J. J., & Atala, A. (1999) · Nature Biotechnology · doi:10.1038/6146 · Cited by 800
Injectable biodegradable materials for orthopedic tissue engineering
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00108-3 · Cited by 554
Horbett, T. A. (1993) · Cardiovascular Pathology · doi:10.1016/1054-8807(93)90054-6 · Cited by 385 · cited 4×
“proteins in solution and the length of reaction [25].”
BackgroundInfluentialGupta, B., Plummer, C. J. G., Bisson, I., Frey, P., & Hilborn, J. G. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00195-8 · Cited by 349
Self-citationSynthetic Biodegradable Polymer Scaffolds
(1997) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-4154-6 · Cited by 264
Introduction of functional groups onto the surface of polyethylene for protein immobilization
Sano, S., Kato, K., & Ikada, Y. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90003-k · Cited by 221
Engineered Smooth Muscle Tissues: Regulating Cell Phenotype with the Scaffold
Kim, B.-S., Nikolovski, J., Bonadio, J., Smiley, E., & Mooney, D. J. (1999) · Experimental Cell Research · doi:10.1006/excr.1999.4595 · Cited by 198
Reconstitution of Human Urothelium From Monolayer Cultures
Scriven, S. D., Booth, C., Thomas, D. F. M., Trejdosiewicz, L. K., & Southgate, J. (1997) · Journal of Urology · doi:10.1016/s0022-5347(01)64407-0 · Cited by 133
Urothelial Tissue Culture for Bladder Reconstruction: An Experimental Study
Hutton, K. A. R., Trejdosiewicz, L. K., Thomas, D. F. M., & Southgate, J. (1993) · The Journal of Urology · doi:10.1016/s0022-5347(17)35597-0 · Cited by 99 · cited 1×
“These cells were harvested from surgical human material, then expanded in vitro in serum-free medium containing cholera toxin, epidermal growth factor and bovine pituitary extract [11–13].”
MethodBLADDER WALL SUBSTITUTION WITH SYNTHETIC AND NON-INTESTINAL ORGANIC MATERIALS
Elbahnasy, A. M., Shalhav, A. L., Hoenig, D. M., Figenshau, R. S., & Clayman, R. V. (1998) · The Journal of Urology · doi:10.1016/s0022-5347(01)63690-5 · Cited by 84 · cited 1×
“These materials have failed due to mechanical, structural or biocompatibility reasons [3].”
BackgroundTissue Engineering in the Genitourinary System
Atala, A. (1997) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-4154-6_8 · Cited by 77 · cited 1×
“Compared to natural matrix materials, synthetic ones can be processed and manufactured in a more reproducible way, and in addition their degradation rate can be defined [6–10].”
BackgroundBladder Smooth Muscle Cells in Culture: I. Identification and Characterization
Baskin, L. S., Howard, P. S., Duckett, J. W., Snyder, H. M., & Macarak, E. J. (1993) · The Journal of Urology · doi:10.1016/s0022-5347(17)36037-8 · Cited by 74 · cited 2×
“If a medium with fetal bovine serum is used, cell monolayers develop first, followed by gradual formation of multilayered arrays without contact inhibition of growth [15].”
BackgroundTISSUE ENGINEERING IN UROLOGIC SURGERY
Atala, A. (1998) · Urologic Clinics of North America · doi:10.1016/s0094-0143(05)70431-6 · Cited by 48
Ito, Y., Zheng, J., & Imanishi, Y. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00119-6 · Cited by 45 · cited 1×
“On these surfaces mouse fibroblast growth was more stimulated than on the same modified surfaces onto which insulin was not pre-immobilized but only added to the cell culture medium [19].”
BackgroundTissue engineering of the bladder
Falke, G. F., Caffaratti, J., & Atala, A. (2000) · World Journal of Urology · doi:10.1007/s003450050007 · Cited by 41 · cited 1×
“Compared to natural matrix materials, synthetic ones can be processed and manufactured in a more reproducible way, and in addition their degradation rate can be defined [6–10].”
BackgroundMast Cell Infiltration in Intestine Used for Bladder Augmentation in Interstitial Cystitis
Kisman, O., Nijeholt, A. A. B. L. À., & van Krieken, J. H. (1991) · The Journal of Urology · doi:10.1016/s0022-5347(17)38017-5 · Cited by 36 · cited 1×
“However, a variety of complications, such as metabolic disorders, infection, mucous and calculi formation or even malignancy have been associated with these nonurological tissues [1,2].”
Background
Cited by
Krishnamoorthy, M., Hakobyan, S., Ramstedt, M., & Gautrot, J. E. (2014) · Chemical Reviews · doi:10.1021/cr500252u · Cited by 604
Surface modification and property analysis of biomedical polymers used for tissue engineering
Ma, Z., Mao, Z., & Gao, C. (2007) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2007.06.019 · Cited by 590
Biocompatibility and safety of PLA and its copolymers
Ramot, Y., Haim-Zada, M., Domb, A. J., & Nyska, A. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.03.012 · Cited by 576
New polymeric architectures with (meth)acrylic acid segments
Mori, H., & Müller, A. H. E. (2003) · Progress in Polymer Science · doi:10.1016/s0079-6700(03)00076-5 · Cited by 277
Biomedical Applications of Nondegradable Polymers
Subramaniam, A., & Sethuraman, S. (2014) · Natural and Synthetic Biomedical Polymers · doi:10.1016/b978-0-12-396983-5.00019-3 · Cited by 75
Metadata
- Authors
- Bisson, I., Kosinski, M., Ruault, S., Gupta, B., Hilborn, J., Wurm, F., & Frey, P.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2002-08
- Volume
- 23
- Issue
- 15
- Pages
- 3149-3158
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2144347515
- Cited by
- 164
- References
- 18
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.